Empowering Scientific Discovery

Titan UC-2 Advanced Ultrasonic Cleaner (2L, 35 kHz)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Titan
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model UC-2
Instrument Type General-Purpose
Capacity 2 L
Ultrasonic Frequency 35 kHz
Ultrasonic Power Output 50 W
Timer Range 1–99 minutes
Sound-Dampening Lid Included

Overview

The Titan UC-2 is a compact, general-purpose ultrasonic cleaner engineered for routine laboratory cleaning tasks requiring consistent cavitation energy and operational reliability. It operates on the principle of piezoelectric transduction, generating high-frequency mechanical vibrations at 35 kHz that propagate through aqueous or compatible solvent media to produce controlled micro-cavitation. This physical phenomenon induces localized high-pressure collapse of transient vapor bubbles, delivering non-abrasive yet effective removal of particulate contaminants, organic residues, and loosely adhered biofilms from delicate instrumentation—including pipette tips, glassware, optical components, and precision metal parts. Designed for benchtop deployment in QC labs, academic research facilities, and small-scale manufacturing environments, the UC-2 balances thermal stability, acoustic uniformity, and user safety without integrated heating—making it suitable for temperature-sensitive samples where ambient-temperature cleaning is preferred.

Key Features

  • Stainless steel tank (304 grade) with seamless construction ensures corrosion resistance and long-term durability under repeated solvent exposure.
  • Precision-tuned 35 kHz transducer array delivers uniform energy distribution across the entire 2 L chamber volume, minimizing dead zones and enhancing cleaning reproducibility.
  • Digital timer with 1–99 minute adjustable interval enables precise process control and repeatability—critical for SOP-driven workflows and GLP-compliant documentation.
  • Integrated sound-dampening lid reduces ambient noise to ≤55 dB(A) during operation, improving laboratory ergonomics and meeting occupational health guidelines for prolonged use.
  • Over-current and over-temperature protection circuits safeguard internal electronics and prevent dry-run damage when operated without sufficient liquid level.
  • Front-panel LED display provides real-time feedback on active cycle time and system status—no external software required for basic operation.

Sample Compatibility & Compliance

The UC-2 accommodates standard laboratory vessels up to 150 mm in height and 120 mm in diameter, supporting common formats such as beakers, test tubes, crucibles, and small disassembly trays. It is compatible with water-based detergents, isopropyl alcohol (≤70%), ethanol, and mild alkaline solutions—though chlorinated solvents and strong acids are not recommended due to material compatibility constraints. While the unit itself is not certified to UL/CE standards, its electrical design complies with IEC 61010-1:2010 safety requirements for laboratory equipment. Users performing regulated cleaning validation (e.g., in pharmaceutical pre-cleaning steps per USP or ISO 15883-1) should conduct in-house performance qualification using standardized soiled substrates and verify residue limits via TOC or HPLC analysis.

Software & Data Management

The UC-2 operates as a standalone analog-digital hybrid instrument with no embedded firmware upgrade path or network interface. All operational parameters are set locally via tactile push-button controls; no data logging, remote monitoring, or audit trail functionality is provided. For laboratories requiring electronic recordkeeping under FDA 21 CFR Part 11 or ISO/IEC 17025, manual entry of batch numbers, operator IDs, and cycle parameters into validated LIMS or ELN systems is recommended. The absence of digital connectivity simplifies maintenance and eliminates cybersecurity vulnerabilities associated with IoT-enabled lab devices.

Applications

  • Routine decontamination of volumetric glassware prior to calibration or trace analysis.
  • Preparation of HPLC sample vials and autosampler components to eliminate carryover artifacts.
  • Cleaning of electron microscopy grids, TEM holders, and AFM probes without surface scratching.
  • Removal of flux residues from PCB prototypes and soldering fixtures in electronics R&D labs.
  • Supporting ASTM D2621 and ISO 10545-14 protocols for ceramic tile and coating adhesion testing sample preparation.
  • Low-risk instrument maintenance in dental, veterinary, and histology labs where autoclaving is impractical.

FAQ

What cleaning solutions are compatible with the UC-2?

Deionized water, low-foaming enzymatic cleaners, and aqueous alkaline solutions (pH 9–11) are optimal. Avoid halogenated hydrocarbons, concentrated nitric acid, and undiluted acetone.
Is the tank depth sufficient for submerging standard 100 mm culture dishes?

Yes—the internal tank depth is 95 mm, allowing full immersion of standard Petri dishes when placed horizontally.
Does the UC-2 include degassing functionality?

No. Degassing must be performed manually by operating the unit for 1–2 minutes without load before introducing samples.
Can the UC-2 be used continuously for extended cycles?

Continuous operation beyond 30 minutes is not recommended; allow ≥10 minutes cooling interval between successive cycles to maintain transducer longevity.
Is calibration or annual verification required?

While no formal calibration certificate is issued, users should periodically verify cavitation intensity using aluminum foil erosion tests per ASTM E1754–01 guidelines.