Empowering Scientific Discovery

YINHEKEJI QCD-1000/1500/3000 Portable Single-Channel Air Sampler

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand YINHEKEJI
Origin Jiangsu, China
Model QCD-1000/1500/3000
Sampling Channel Single
Flow Range 0.1–1.0 L/min (QCD-1000)
Maximum Vacuum Pressure >35 kPa
Flow Stability ≤5%
Flowmeter Accuracy ±2.5% FS
Flow Error at Load ≤±5%
Load Capacity ≥1.0 L/min at 4.5 kPa backpressure
Battery 7.4 V / 2200 mAh Li-ion
Operating Temperature −10 °C to +40 °C
Continuous Operation Time ≥12 h
Weight ≤0.5 kg
Timing Range 1 min to 99 h 59 min
Timing Accuracy ≤±0.1%
Service Life at Max Load >5000 h
Runtime at Max Flow & Max Backpressure 8–10 h

Overview

The YINHEKEJI QCD-1000/1500/3000 Portable Single-Channel Air Sampler is a precision-engineered, battery-powered instrument designed for quantitative collection of airborne gaseous and vapor-phase contaminants in occupational health, environmental monitoring, and industrial hygiene applications. It operates on the principle of controlled volumetric sampling via a diaphragm pump driven by regulated DC power, with flow maintained through integrated needle-valve adjustment and calibrated rotameter or digital flow sensing (depending on configuration). The device complies with fundamental requirements outlined in ISO 16000-1, OSHA Method 0016, NIOSH Manual of Analytical Methods (NMAM) Chapter 2, and EU Directive 2004/108/EC for electromagnetic compatibility. Its compact form factor (≤0.5 kg), robust mechanical architecture, and dual-power capability—rechargeable lithium-ion battery (7.4 V / 2200 mAh) or optional AC adapter—enable field-deployable operation across diverse ambient conditions (−10 °C to +40 °C). Designed for long-term reliability, the unit delivers >5000 hours of operational service life under maximum load conditions.

Key Features

  • Three model variants optimized for distinct flow regimes: QCD-1000 (0.1–1.0 L/min), QCD-1500 (0.1–1.5 L/min), and QCD-3000 (0.1–3.0 L/min), enabling method-specific compliance with EPA TO-15, ISO 16017-1, and EN 13644-1 protocols.
  • High-vacuum diaphragm pump generating >35 kPa suction pressure, ensuring stable flow delivery even when sampling through high-resistance media such as activated carbon tubes, silica gel cartridges, or impingers loaded with absorbent solutions.
  • Digital LCD display with backlight and real-time clock functionality; supports programmable sampling duration from 1 minute to 99 hours 59 minutes with timing accuracy ≤±0.1%.
  • Integrated flow regulation system featuring adjustable needle valve and calibrated flowmeter (±2.5% full-scale accuracy), delivering ≤±5% total flow error under specified backpressure (up to 4.5 kPa).
  • Low-power electronics architecture enabling ≥12 hours of continuous operation on a single battery charge; battery voltage monitoring with visual low-voltage alert (blinking battery icon).
  • Compact, ergonomic housing with IP54-rated ingress protection; includes dedicated safety bottle, absorption tube holder, tripod mount, and chemically resistant silicone tubing to prevent liquid carryover and pump membrane damage.

Sample Compatibility & Compliance

The QCD series is validated for use with standard sorbent tubes (e.g., Tenax TA, Carbopack B/C, silica gel), impinger solutions (e.g., NaOH for SO₂, H₂O₂ for NOₓ), and filter cassettes (e.g., PVC, PTFE, mixed-cellulose ester) per NIOSH and ISO sampling methodologies. All models meet functional equivalence criteria for gravimetric and thermal desorption-based analysis workflows. Device firmware and hardware design support audit-ready documentation practices aligned with GLP and ISO/IEC 17025 laboratory quality systems. While not inherently 21 CFR Part 11 compliant due to lack of electronic signature capability, raw timing and flow data are traceable via manual logbook entries and external calibration certificates.

Software & Data Management

The QCD-1000/1500/3000 operates as a standalone hardware platform without embedded software or cloud connectivity. All operational parameters—including start time, duration, and user-set flow rate—are recorded manually in field logs or synchronized with external data acquisition systems via analog output (optional) or timed relay triggers. Calibration records must be maintained externally per ISO/IEC 17025 Clause 6.4.2. For regulatory submissions, users are required to retain original calibration certificates, battery charge logs, and sampling event worksheets demonstrating traceability to national standards (e.g., NIST-traceable flow calibrators).

Applications

  • Occupational exposure assessment for VOCs, aldehydes, organic acids, and inorganic gases (e.g., CO, H₂S, Cl₂) in metallurgical, chemical manufacturing, and power generation facilities.
  • Ambient air quality monitoring for regulatory reporting under national frameworks including China’s HJ 194-2017 and EU Air Quality Directive 2008/50/EC.
  • Indoor air quality (IAQ) surveys in commercial buildings, schools, and healthcare settings per ASHRAE Standard 62.1.
  • Method validation and proficiency testing in accredited environmental laboratories conducting ISO 16000-6, ISO 16017-2, and ASTM D5197 analyses.
  • Emergency response deployment during chemical spills or fugitive emission investigations where rapid, portable, and repeatable sampling is critical.

FAQ

What power sources does the QCD series support?
The instrument operates exclusively on its internal 7.4 V / 2200 mAh rechargeable lithium-ion battery. An optional AC adapter is available for benchtop or extended-duration stationary use.
Is the flow rate adjustable during active sampling?
Yes—flow is manually adjusted via the integrated needle valve before initiating sampling; real-time dynamic adjustment during operation is not supported.
Does the device include data logging capability?
No. The QCD series provides only visual time and status feedback via LCD. External data loggers or manual recording are required for compliance documentation.
What maintenance is required to ensure long-term performance?
Users must inspect and replace the inlet safety bottle and tubing after each sampling campaign involving condensable vapors or aerosols; annual recalibration of the flowmeter against a NIST-traceable primary standard is recommended.
Can the QCD sampler be used for personal sampling?
Yes—its lightweight design (≤0.5 kg), belt-clip compatibility (via optional accessory), and quiet diaphragm pump make it suitable for worker-worn configurations per ISO 7708 and ACGIH TLV® guidelines.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0