Empowering Scientific Discovery

SICCO V1830-07 Temperature-Tunable Drying Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand SICCO
Origin Germany
Model V1830-07
Instrument Type Vacuum Drying Oven
Temperature Range −20 °C to 70 °C
Temperature Uniformity ±1.75 °C at 40 °C
External Dimensions (W×H×D) 310×630×420 mm
Internal Chamber Dimensions (W×H×D) 260×480×330 mm
Chamber Material PMMA (Polymethyl Methacrylate)
Heating Method Forced-Air Circulation
Rated Power 850 W
Supply Voltage 230 V / 50 Hz
Temperature Setting Resolution 1 °C
Chamber Capacity 55 L
Net Weight 16 kg
Max. Load per Shelf 10 kg
Total Max. Load 40 kg (4 shelves × 10 kg)

Overview

The SICCO V1830-07 Temperature-Tunable Drying Oven is a precision-engineered laboratory drying system designed for controlled, low-temperature dehydration, solvent removal, and thermal stabilization of moisture-sensitive or thermolabile samples. Unlike conventional convection ovens, this unit integrates forced-air circulation with high-transparency PMMA chamber construction and dual-glass thermal insulation—comprising an inner borosilicate glass layer and outer PMMA panel—to minimize thermal bridging while enabling real-time visual monitoring without opening the chamber. Its operational temperature range spans from −20 °C to +70 °C, supporting both ambient-assisted drying and sub-ambient conditioning—a capability critical for applications involving volatile organic compounds (VOCs), hygroscopic polymers, pharmaceutical intermediates, or biological matrices where oxidative degradation or phase separation must be avoided. The system is configured for vacuum compatibility (vacuum port optional; not included by default), allowing integration with external vacuum pumps to reduce boiling points and accelerate drying kinetics under reduced pressure.

Key Features

  • Forced-air heating system (850 W) with axial fan and optimized airflow ducting ensures uniform temperature distribution across the 55 L chamber, validated to ±1.75 °C at 40 °C per DIN 12880.
  • Four adjustable, load-rated PMMA shelves (10 kg capacity each), chemically inert and optically transparent, permitting unobstructed observation and minimizing sample shading effects during thermal exposure.
  • Dual-layer chamber wall: inner borosilicate glass provides thermal stability and chemical resistance; outer PMMA panel delivers impact resistance, UV transparency, and low thermal conductivity (0.19 W/m·K).
  • Digital PID temperature controller with 1 °C resolution, programmable ramp/soak profiles, and independent over-temperature safety cutoff (independent mechanical thermostat, Class 3.0 per IEC 61000-4-2).
  • Aluminum alloy frame with powder-coated finish ensures structural rigidity, ESD-safe grounding, and long-term dimensional stability under repeated thermal cycling.
  • Compliant with EN 61010-1:2019 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) and CE-marked for use in EU-based GLP/GMP environments.

Sample Compatibility & Compliance

The V1830-07 accommodates a broad spectrum of sample formats—including Petri dishes, weighing boats, glass vials, polymer films, and ceramic substrates—without risk of leaching or catalytic surface interaction, owing to its all-PMMA/borosilicate internal architecture. It supports drying protocols aligned with ASTM D1654 (corrosion testing), ISO 11120 (moisture content in powders), and USP (packaging integrity for pharmaceuticals). When operated under vacuum (with compatible external pump), it meets requirements for residual solvent analysis per ICH Q3C guidelines. All electrical components conform to RoHS 2011/65/EU and REACH SVHC regulations. No silicone gaskets or rubber seals are used in the chamber seal assembly—eliminating outgassing risks in ultra-clean or analytical-grade workflows.

Software & Data Management

While the base V1830-07 operates via standalone front-panel control, optional RS-485 interface (Modbus RTU protocol) enables integration into centralized lab automation systems (e.g., LabWare LIMS, Thermo Fisher SampleManager). Temperature logging is supported via external data loggers compliant with FDA 21 CFR Part 11 (electronic records/signatures), provided audit trail configuration, user access levels, and data integrity validation are implemented at the host system level. Real-time temperature traceability is achievable using calibrated Pt100 sensors traceable to NIST standards (calibration certificate available upon request).

Applications

  • Residual solvent removal from API crystallization batches prior to lyophilization or tablet compression.
  • Controlled dehydration of hydrogels, electrospun nanofibers, and MOF precursors without pore collapse.
  • Conditioning of reference standards and certified reference materials (CRMs) under defined RH–T profiles.
  • Accelerated aging studies for packaging materials per ISO 11607-1, using sub-60 °C thermal stress without oxidation.
  • Pre-drying of FTIR ATR crystals, SEM stubs, and TEM grids to eliminate adsorbed water layers affecting spectral or imaging fidelity.
  • Low-temperature annealing of printed electronics substrates (e.g., PEDOT:PSS, perovskite precursors) where thermal budget is constrained.

FAQ

Is the V1830-07 certified for use in GMP-regulated laboratories?

Yes—the unit complies with EN 61010-1:2019 and carries CE marking; full IQ/OQ documentation packages and 3Q validation support are available through authorized SICCO distributors.
Can the PMMA chamber withstand exposure to acetone or chloroform?

PMMA exhibits limited resistance to chlorinated solvents and ketones; prolonged contact with acetone or chloroform may cause stress cracking. For aggressive solvents, optional borosilicate-only chamber variants (e.g., V1823-07) are recommended.
Does the oven include vacuum connection hardware?

No—vacuum operation requires external pump and separate vacuum-rated hose/fittings (KF16 or ISO-KF25 flange adapters available as accessories).
What is the maximum allowable ambient operating temperature for continuous use?

The unit is rated for ambient temperatures up to 35 °C (IEC 60068-2-1); operation above this threshold may compromise temperature stability and shorten fan service life.
Are calibration certificates included with shipment?

A factory-as-tested temperature uniformity report is supplied; NIST-traceable calibration certificates (including multi-point verification at 25 °C, 40 °C, and 60 °C) are available as a chargeable option.