Empowering Scientific Discovery

Microphotons λ-Rapid 1580 High-Speed ASE-Free Tunable Diode Laser

Add to compare
Sold by
Brand Microphotons
Origin Japan
Manufacturer Type OEM Manufacturer
Origin Category Imported
Model λ-Rapid 1580
Pricing Upon Request

Ask about pricing, availability and specifications.

Overview

The Microphotons λ-Rapid 1580 is a high-performance, continuously tunable diode laser engineered for precision spectroscopic applications requiring rapid wavelength scanning, narrow linewidth, and exceptional suppression of amplified spontaneous emission (ASE). Operating in the 1520–1630 nm C+L band, it leverages external cavity diode laser (ECDL) architecture with a high-finesse grating-based wavelength selection mechanism. Unlike broadband ASE-prone semiconductor lasers, the λ-Rapid 1580 integrates an intracavity optical filter and optimized gain chip design to achieve ASE suppression exceeding 60 dB relative to the main lasing line—critical for high signal-to-noise ratio (SNR) measurements in absorption spectroscopy, cavity ring-down spectroscopy (CRDS), and swept-wavelength interferometry. Its scan speed reaches up to 200 nm/s with sub-pm wavelength resolution and <100 kHz instantaneous linewidth, enabling real-time monitoring of dynamic spectral features without mode hops or thermal drift artifacts.

Key Features

  • Ultra-low ASE background (< −60 dBc), eliminating spectral contamination in sensitive detection schemes
  • Continuous, mode-hop-free tuning across 1520–1630 nm with <0.1 pm step resolution and ±1 pm absolute wavelength accuracy (traceable to NIST-calibrated wavemeters)
  • High-speed scanning capability: 0.1–200 nm/s programmable sweep rates with linearized wavelength output
  • Integrated thermoelectric cooler (TEC) and high-stability current driver ensuring <±0.01 nm/h wavelength drift over 8-hour operation
  • RS-232, USB 2.0, and analog modulation inputs (0–5 V) for seamless integration into automated optical test benches
  • FC/APC fiber-coupled output with PMF (Panda-type polarization-maintaining fiber) option for coherent applications

Sample Compatibility & Compliance

The λ-Rapid 1580 is designed for laboratory and industrial R&D environments where regulatory traceability and operational reliability are mandatory. It complies with IEC 61000-6-3 (EMC emission standards) and IEC 60825-1:2014 (laser safety Class 1 when enclosed, Class 3B at fiber output port). All wavelength calibration data are generated using traceable reference gas cells (e.g., acetylene, hydrogen cyanide) and validated against ISO/IEC 17025-accredited metrology labs. The instrument supports GLP/GMP-aligned operation through optional firmware-enabled audit trail logging (user actions, calibration events, parameter changes), meeting foundational requirements for FDA 21 CFR Part 11 compliance when deployed in regulated analytical workflows.

Software & Data Management

Microphotons provides the λ-Control Suite—a cross-platform (Windows/macOS/Linux) application supporting full remote control, scriptable sweep sequencing, and real-time spectral data acquisition synchronization via TTL triggers. The software exports calibrated wavelength-intensity datasets in HDF5 and CSV formats, compatible with MATLAB, Python (NumPy/Pandas), and LabVIEW. For enterprise integration, a documented TCP/IP API enables direct control from custom LIMS or MES platforms. Firmware updates preserve backward compatibility and include cryptographic signature verification to ensure integrity during field deployment.

Applications

  • High-resolution gas-phase absorption spectroscopy (e.g., CH₄, CO₂, NH₃ detection in environmental monitoring)
  • Optical coherence tomography (OCT) system development requiring long coherence length and rapid A-scan acquisition
  • Characterization of ultra-narrowband filters, FBGs, and photonic integrated circuits (PICs)
  • Calibration source for wavelength meters and optical spectrum analyzers (OSAs)
  • Time-resolved pump-probe experiments where ASE-free excitation minimizes background interference
  • Development of quantum communication systems requiring precisely defined telecom-band photons

FAQ

What is the typical tuning hysteresis over a full 1520–1630 nm sweep?

Hysteresis is ≤ ±0.5 pm under standard operating conditions; repeatable sweeps demonstrate <0.2 pm RMS deviation across 100 cycles.

Can the laser be operated in continuous-wave (CW) mode at a fixed wavelength?

Yes—CW operation is supported with <0.005 nm/h drift and RMS intensity noise <0.15% (10 Hz–10 MHz bandwidth).

Is fiber coupling polarization-maintaining by default?

Standard configuration uses SMF-28; PMF (Panda-type) is available as a factory-configurable option with extinction ratio >25 dB.

Does the system include wavelength calibration certification?

Each unit ships with a manufacturer-issued calibration report referencing NIST-traceable standards; ISO/IEC 17025 certification is available upon request.

What is the expected lifetime of the laser diode under specified operating conditions?

MTTF exceeds 50,000 hours at 25°C case temperature and rated drive current, per Telcordia GR-468-CORE reliability testing protocols.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0