BrandSevenStar
OriginBeijing, China
ModelD07-11C
TypeVolumetric (Thermal Mass Flow Principle)
Flow Range5–30 sccm, 50–500 sccm, 1–30 slm
Accuracy±1% F.S. (±2% F.S. for 20 & 30 slm)
Repeatability±0.2% F.S.
Linearity±0.5% F.S. (±2% F.S. for 20 & 30 slm)
Response TimeElectrical ≤10 s
Operating Temperature5–45 °C
Max Working Pressure10 MPa
Sealing MaterialsViton®, Neoprene, PTFE
Input/Output Signal0–5 V DC (Zin >100 kΩ, Iout ≤3 mA)
Power Supply±15 V DC
Electrical InterfaceD-Sub 15-pin Male
Pressure Drop Range0.2–0.6 MPa (for F.S. >10 slm)
Helium Leak Rate≤1×10⁻¹⁰ atm·cm³/s (≤1×10⁻¹¹ Pa·m³/s)
Standard FittingsDual Ferrule 1/8", Φ3 mm, Φ6 mm, Φ8 mm, Φ10 mm, 3/8", 1/4", VCR 1/4"
EMI ImmunityCE Certified
Weight1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD08-1F
Power Supply±15 V DC / 400 mA, +5.00 V DC / 5 mA
Input Voltage Range85–260 V AC
Max. Power Consumption15 W
Analog Input Signals0–+5 V (voltage), 4–20 mA (current, optional 0–10 mA)
Analog Output Signals0–+5 V (flow detection), ±15 V (valve control)
Display Channels1-channel MFC/MFM interface
Weight1 kg
ComplianceCE-certified
TypeVolumetric flow display instrument for gas mass flow controllers and meters
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD07-7CM
Flow PrincipleThermal Mass Flow Measurement (Constant Temperature Anemometry)
Gas MediumN₂-calibrated (standardized at 0 °C, 101.325 kPa)
Full-Scale Range5 SCCM – 10 SLM (N₂)
Control Range2–100 % F.S.
Accuracy±1.5 % F.S.
Linearity±1 % F.S.
Repeatability±0.2 % F.S.
Response Time≤10 s
Operating Temperature5–45 °C
Maximum Pressure Drop<0.01 MPa
Burst Pressure3 MPa
Helium Leak Rate≤1×10⁻⁸ atm·cm³/s
Sealing MaterialFluoroelastomer (FKM) or Neoprene
Power Supply+15 V/50 mA, −15 V/50 mA
Analog Output0–5.00 V DC
Electrical ConnectorDB15 female
Process ConnectionsVCR 1/4″, Swagelok 1/4″, or φ3/φ4/φ6 stainless steel tubing
EMC ComplianceCE certified
Weight0.92 kg
ConstructionTubular bypass design with integrated thermal sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD07-19CM
Flow TypeThermal Mass Flow Measurement
Gas Calibration MediumNitrogen (N₂)
Standard Conditions0 °C (273.15 K), 101325 Pa
Full-Scale Range (N₂)5 SCCM to 20 SLM
Control Range2–100% F.S.
Accuracy±1% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Linearity±0.5% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Repeatability±0.2% F.S.
Response Time≤1.5 s
Zero Temp. Coefficient≤±0.05% F.S./°C
Span Temp. Coefficient≤±0.1% F.S./°C
Operating Temperature5–45 °C
Maximum Working Pressure Drop<0.02 MPa
Burst Pressure Rating10 MPa
Helium Leak Rate≤1×10⁻⁹ SCCS
Sealing MaterialsFluoroelastomer (FKM), Polytetrafluoroethylene (PTFE), Chloroprene Rubber (CR)
Process ConnectionsVCR 1/4″, φ4 mm / φ6 mm hose, Swagelok 1/8″ / 1/4″, or φ3 mm / φ6 mm tubing
Electrical InterfaceDB15 male connector
EMC ComplianceCE certified
Weight1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD07-19C
Flow TypeThermal Mass Flow
Full-Scale Range (N₂)5 SCCM to 20 SLM
Control Range2–100% F.S.
Valve TypeSolenoid-Controlled Proportional Valve (Normally Closed)
Accuracy±1% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Linearity±0.5–1% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Repeatability±0.2% F.S.
Zero Temp. Coefficient≤±0.05% F.S./°C
Span Temp. Coefficient≤±0.1% F.S./°C
Response Time≤1.5 s
Operating Temperature5–45°C
Operating Differential Pressure0.1–0.5 MPa (≤10 SLM), 0.1–0.3 MPa (>10 SLM)
Burst Pressure3 MPa
Leak Rate≤1×10⁻⁹ SCCS He
Sealing MaterialsFluoroelastomer (FKM), Polytetrafluoroethylene (PTFE), Chloroprene Rubber (CR)
Mechanical Interface OptionsVCR 1/4", φ4 mm / φ6 mm hose, Swagelok 1/8" / 1/4", φ3 mm / φ6 mm tubing
Electrical InterfaceDB15 Male Connector
EMC ComplianceCE
Weight1.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelCS300
Product TypeVolumetric Mass Flow Controller
Accuracy±1% S.P. (≥35% F.S.), ±0.35% F.S. (<35% F.S.)
Linearity±0.5% F.S.
Repeatability±0.2% F.S.
Response Time≤0.8 sec (≤0.5 sec optional)
Operating Pressure Drop Range0.05–0.35 MPa (≤10 SLM), 0.1–0.35 MPa (>10 SLM), <0.02 MPa (for low-pressure variants)
Temperature CoefficientZero ≤±0.02% F.S./°C
Burst Pressure3.5 MPa
Helium Leak Rate≤1×10⁻¹¹ Pa·m³/sec
Surface RoughnessRa ≤5 µin
Input/OutputRS485 / DeviceNet / (0–5) VDC
Power Supply±11–±16 VDC (bipolar) or +11–+28 VDC (unipolar)
Operating Ambient Temperature0–50 °C
Standard Fitting TypesVCR 1/4", 1.125" C/W, 1.5" B/C/W
Enclosure Weight0.8–1.2 kg
Sealing MaterialMetal
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD07-19BM
Flow TypeThermal Mass Flow Measurement
Gas Calibration MediumNitrogen (N₂)
Standard Conditions0 °C (273.15 K), 101325 Pa
Full-Scale Range (N₂)5 SCCM to 30 SLM
Control Range2–100% F.S.
Accuracy±1% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Linearity±0.5–1% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Repeatability±0.2% F.S.
Response Time≤2 s
Operating Temperature5–45 °C
Maximum Working Pressure Drop<0.02 MPa
Burst Pressure Rating10 MPa
Helium Leak Rate≤1×10⁻⁹ SCCS He
Sealing MaterialsFluoroelastomer (FKM), Polytetrafluoroethylene (PTFE), Chloroprene Rubber (CR)
Mechanical Interface OptionsVCR 1/4″, φ4 mm / φ6 mm hose barb, Swagelok 1/8″ / 1/4″, or φ3 mm / φ6 mm tubing ports
Electrical ConnectorDB15 male
EMC ComplianceCE certified
Weight0.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD08-8C
TypeVolumetric Flow Totalizer
Power Supply85–265 VAC, 50/60 Hz, 12 W
Output Voltages+15 V @ 200 mA, −15 V @ 400 mA
Max. Accumulated Flow999999 L or m³
Accumulation Accuracy< ±0.3% FS
Input/Output Signals0–+5 V analog (flow detection, setpoint, valve control)
DisplayDual digital LCD (instantaneous & cumulative flow)
Control Channels1-channel MFM/MFC interface
Weight0.5 kg
Enclosure GroundingDedicated chassis ground terminal
ComplianceCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD07-7B
TypeThermal Mass Flow Controller
Flow Ranges5–10,000 sccm (selectable per unit)
Accuracy±1.5% FS
Repeatability±0.2% FS
Linearity±1.0% FS
Response Time (Electrical)≤10 s
Response Time (Gas)≤4 s
Operating Temperature5–45 °C
Maximum Working Pressure3 MPa
Pressure Drop Range0.1–0.5 MPa
Seal MaterialsViton (FKM), Neoprene
Input/Output Signal0–5 V DC (Input Impedance >100 kΩ
Power Supply+15 V / 50 mA, −15 V / 200 mA
Electrical InterfaceD-Sub 15-pin Female
Leak Rate≤1×10⁻⁸ atm·cm³/s He (≤1×10⁻⁹ Pa·m³/s He)
Standard FittingsDual Ferrule (Φ3/Φ6/Φ8 mm, 1/8″/1/4″), VCR 1/4″, φ4×1 & φ6×1 Flexible Tube Ports
Weight1.1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD07-7C
Flow Range (N₂)5 SCCM to 10 SLM
Control Range2–100% F.S.
Valve TypeSolenoid-Controlled Proportional Valve (Normally Closed)
Accuracy±1.5% F.S.
Linearity±1% F.S.
Repeatability±0.2% F.S.
Electrical Response Time10 s
Gas Response Time≤4 s
Operating Temperature5–45 °C
Operating Pressure Drop0.1–0.5 MPa
Burst Pressure Rating3 MPa
Helium Leak Rate≤1×10⁻⁸ atm·cm³/s
Sealing MaterialsFluoroelastomer (FKM), Chloroprene Rubber (CR)
Electrical ConnectorDB15 Female
Tube Fitting OptionsVCR 1/4″, φ4 mm & φ6 mm hose, Swagelok 1/4″, φ3 mm & φ6 mm
EMC ComplianceCE
Weight1.1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelCS200(A)
TypeVolumetric Mass Flow Controller
Flow Range5 sccm to 50 slm
Accuracy±0.35% F.S. (<35% F.S.), ±1.0% S.P. (≥35% F.S.)
Repeatability±0.2% F.S.
Linearity±0.5% F.S.
Response Time≤1 sec
Operating Temperature5–45 °C
Max Pressure Rating3 MPa
Seal MaterialViton® fluoroelastomer
Input/Output Signals0–5 VDC, 0–20 mA, 4–20 mA, RS-485, DeviceNet®, Profibus®
Power Supply±15 VDC, 24 VDC, or +14–+28 VDC
Valve ConfigurationNormally Open (≤30 slm), Normally Closed (>30 slm)
Zero Drift<0.6% F.S./year (without auto-zero)
Temperature CoefficientsZero ≤±0.05% F.S./°C
Pressure Drop Range0.05–0.35 MPa (F.S. ≤10 slm), 0.1–0.35 MPa (10–30 slm), 0.2–0.45 MPa (>30 slm)
Helium Leak Rate≤1×10⁻¹⁰ Pa·m³/sec
Standard FittingsDual Ferrule 1/4", 1/8", Φ3 mm, Φ6 mm, Φ10 mm, 3/8", VCR 1/4", VCO 1/4"
Surface Roughness25 µin
EMC ComplianceCE
Weight1 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSevenStar
OriginBeijing, China
ModelD07-19B
Flow TypeThermal Mass Flow (N₂-calibrated)
Full-Scale Range5 SCCM – 30 SLM
Control Range2–100% F.S.
Accuracy±1% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Linearity±0.5–1% F.S. (≤10 SLM), ±2% F.S. (>10 SLM)
Repeatability±0.2% F.S.
Response Time≤2 s
Operating Temperature5–45 °C
Pressure Drop0.1–0.5 MPa (≤10 SLM), 0.1–0.3 MPa (>10 SLM)
Burst Pressure3 MPa
Helium Leak Rate≤1×10⁻⁹ SCCS
Sealing MaterialsViton®, PTFE, Neoprene
Electrical InterfaceDB15 male connector
Mechanical InterfacesVCR 1/4", φ4 mm / φ6 mm hose, Swagelok 1/8" / 1/4", or φ3 mm / φ6 mm tubing
EMC ComplianceCE
Weight0.95 kg