Cowie
Filter
Showing all 6 results
| Brand | Cowie |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer (Not OEM/Contractor) |
| Product Category | Imported Laboratory Equipment |
| Model | PTFE Magnetic Stir Bar Kit |
| Instrument Type | Magnetic Stirrer Accessory |
| Max. Stirring Volume | 2000 mL |
| Speed Range Compatibility | 1–1500 rpm (typical for standard magnetic stirrers) |
| Temperature Resistance | –200 °C to +280 °C continuous |
| Brand | Cowie |
|---|---|
| Origin | United Kingdom |
| Model | PTFE Centrifugal / Anchor / Propeller / Interchangeable-Blade Stirring Impellers |
| Material Certification | FDA-compliant & USP Class VI-certified PTFE |
| Shaft Construction | Stainless steel core encapsulated in PTFE |
| Temperature Range | −200 °C to +280 °C |
| Max. Working Vacuum | 5 mbar |
| Compliance | BS EN ISO 9001:2008 |
| Sterilization | Autoclavable (121 °C, 20 min), chemical-resistant, non-leaching, non-porous surface |
| Cleaning | Compatible with aqueous and organic solvent cleaning protocols |
| Brand | COWIE |
|---|---|
| Origin | United Kingdom |
| Connector Type | Lemo Interface / K-Type Thermocouple |
| Sensor Types | PT100 (4-wire), PT1000, K-Type, J-Type, T-Type |
| Temperature Range | –200 °C to +400 °C (short-term), –70 °C to +300 °C (continuous for PT100 variant), –180 °C to +300 °C (continuous for K-type variant) |
| Sheath Material | Virgin PTFE fully encapsulated body with PFA-insulated cable |
| Core Structure | Stainless steel mandrel — rigid yet bendable |
| Cable Termination | 1 m standard lead |
| Compliance | BS EN ISO 9001:2008 certified |
| Regulatory Status | FDA-compliant PTFE materials |
| Sealing | PFA fusion-welded cable-to-body junction for leak-tight integrity |
| Brand | Cowie |
|---|---|
| Origin | United Kingdom |
| Product Type | PTFE-Coated Magnetic Stir Bar |
| Material Certification | FDA-Approved & USP Class VI Compliant |
| Temperature Range | –200 °C to +280 °C (short-term exposure up to +400 °C with thermal degradation onset, non-melting) |
| Sterilization Compatibility | Autoclave (121 °C, 20 min), dry heat, ethylene oxide, hydrogen peroxide plasma — not gamma irradiation |
| Shape Options | Cylindrical, Oval, Cross-shaped |
| Surface | Fully PTFE-encapsulated, chemically inert, non-porous |
| Compliance | BS EN ISO 9001:2008 certified manufacturing |
| Brand | COWIE |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Housing Material | Fully PTFE-Coated Surface |
| Speed Range (Standard) | 50–800 rpm |
| Speed Range (Biological Mode) | 10–160 rpm |
| Max. Working Volume | 2 L |
| Dimensions | 130 × 130 × 50 mm |
| Weight | 1.3 kg (incl. power supply) |
| Operating Ambient Temperature | 0–40 °C |
| Compliance | BS EN ISO 9001:2008 certified |
| PTFE Material | FDA-compliant per 21 CFR §177.1550 |
| Brand | Cowie |
|---|---|
| Origin | United Kingdom |
| Model | Universal Stirring Seal Assembly / PTFE Reactor Lid |
| Instrument Type | Magnetic Stirrer Accessory |
| Max. Working Volume | 800 mL |
| Speed Range | 1–500 rpm (continuous), 800 rpm (intermittent) |
| Temp. Range | −200 °C to +280 °C |
| Material | Virgin PTFE (Polytetrafluoroethylene) |
| Vacuum Rating | ~5 mmHg |
| Pressure Rating | 3–5 psi (gauge) |
| Sealing Interface | NPT-threaded interchangeable port fittings |
| Compliance | Designed for GLP/GMP-adjacent lab environments requiring chemical inertness and cleanability |