Labotery
Filter
Showing 31–57 of 57 results
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | XJS36-42W |
| Automation Level | Fully Automatic |
| Digestion Positions | 24 |
| Max Heating Temperature | 360 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Heating Principle | High-Purity Graphite Block with PTFE Coating |
| Reagent Channels | 36 |
| Power Supply | 220 V / 50 Hz |
| Sample Capacity | 42 × 50 mL (compatible with standard digestion tubes) |
| Temperature Resolution | 0.1 °C |
| Inter-Position Uniformity | ±1.5 °C |
| Single-Position Temp. Stability | ±0.5 °C |
| Operating Ambient | 5–25 °C |
| Continuous Operation Duration | >48 h |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | XJT16-20 / XJT20-20 / XJT40-20 / XJS60-24 / XJS20-42 / XJS40-42 |
| Heating Method | High-Purity Graphite Block with PTFE Coating |
| Max Temperature | 220 °C / 260 °C / 450 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Inter-hole Uniformity | ±1.5 °C |
| Sample Capacity | 20×100 mL / 40×50 mL / 60×50 mL / 20×100 mL / 40×50 mL |
| Heating Power | 1800–3000 W |
| Control System | 30-Step Programmable LCD Controller with PID Auto-Tuning |
| Safety Features | Over-Temperature Alarm, Acid-Resistant Modular Design, Reflux Venting |
| Compliance | Designed for EPA 3010a, 3050b, 3060 |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | XJT16-20W |
| Digestion Method | Rapid Digestion |
| Heating Module | Dual Graphite Heating Blocks |
| Batch Capacity | 16 × 100 mL |
| Temperature Range | 0–220 °C |
| Temperature Accuracy | ±0.2 °C |
| Timer Accuracy | ±0 s |
| Sample Well Diameter × Depth | Φ44 × 50 mm |
| Heating Block Dimensions (L×W×H) | 355 × 301 × 240 mm |
| Power Supply | 220 V / 50 Hz |
| Heating Material | High-Purity Graphite with PTFE Coating |
| Max. Power Consumption | 1500 W |
| Temperature Resolution | 0.1 °C |
| Inter-Well Uniformity | ±1.5 °C |
| Single-Well Temp. Stability | ±0.5 °C |
| Continuous Operation Duration | >48 h |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | YPJ-300 / YPJ-300S |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 30–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 35 mm |
| Temperature Range | Ambient +5°C to +25°C (non-thermostatic) |
| Deck Quantity | 2 |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 0.3 kW |
| Dimensions (L×W×H) | 900×780×725 mm |
| Net Weight | 400 kg |
| Deck Size | 800×600 mm |
| Load Capacity (per deck) | 250 mL ×42 / 500 mL ×30 / 1000 mL ×20 / 2000 mL ×12 |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | YPJ-300S |
| Instrument Type | Orbital Shaker (Dual-Layer) |
| Timing Range | 0–999.9 min/h |
| Oscillation Frequency | 30–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 35 mm |
| Tray Dimensions | 800 × 600 mm |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 0.3 kW |
| External Dimensions (L×W×H) | 900 × 780 × 725 mm |
| Net Weight | 400 kg |
| Operating Ambient Temperature | 5–25 °C |
| Storage Temperature | –10–50 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Compliance | CE-marked per IEC 61000-6-3 (EMI) and IEC 61000-6-2 (Immunity) |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZHP-100G |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Uniformity | ±0.3°C (at 37°C) |
| Humidity Range | 20–50% RH |
| Chamber Capacity | 100 L |
| Orbital Speed | 30–400 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | Φ0–50 mm (continuously adjustable) |
| Shelf Dimensions | 400 × 370 mm |
| Max Load Capacity | 100 mL × 23 or 250 mL × 16 or 500 mL × 9 or 1000 mL × 5 or 2000 mL × 4 |
| Timer Range | 0–999.9 min |
| Power Consumption | 0.8 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions | 550 × 780 × 640 mm |
| Temperature Resolution | 0.1°C |
| Temperature Stability | ±0.3°C (at 37°C) |
| Safety Features | Door-activated stop, over-temperature alarm & auto cut-off, motor over-current protection, power failure memory, self-diagnostic system |
| Control Interface | Full-color LCD touchscreen with navigational soft keys |
| Drive System | Brushless DC servo motor with reversible programmable operation (forward/reverse/stop cycles) |
| Air Circulation | Forced convection via optimized ducted airflow path |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZHPL-200 (Heating-only), ZQPL-200 (Heating & Refrigeration) |
| Temperature Range | 4–65°C |
| Oscillation Frequency | 10–300 rpm ±1 rpm |
| Amplitude | Ø26 mm |
| Timer Range | 0–9999 minutes/hours |
| Shelf Quantity | 2 |
| Shelf Dimensions | 439 × 528 mm |
| Power Consumption | 11.3 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 740 × 730 × 1235 mm |
| Temperature Uniformity | ±0.5°C at 37°C |
| Temperature Stability | ±0.3°C at 37°C |
| Control System | PID microcomputer with LCD or color touchscreen interface |
| Cooling System | R134a-free compressor with dust-filtered airflow and cross-flow air duct design |
| Drive Mechanism | Brushless servo motor with eccentric triple-wheel drive |
| Safety Features | Door interlock stop, over-temperature audiovisual alarm + auto power cutoff, motor overcurrent protection, self-diagnostic fault reporting, power-loss memory |
| Sterilization | Built-in UV lamp |
| Optional Interfaces | RS-485 remote control, USB data export, thermal printer module |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZHPL-500 |
| Instrument Type | Water-Jacketed Constant-Temperature Orbital Shaker |
| Timer Range | 0–9999 min (or hr) |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm |
| Temperature Range | Ambient +5°C to 65°C |
| Temperature Uniformity | ±0.5°C (at 37°C) |
| Temperature Fluctuation | ±0.3°C (at 37°C) |
| Temperature Resolution | 0.1°C |
| Control Method | PID Microcomputer Control |
| Shelf Dimensions/Quantity | 830 × 508 mm / 2 shelves |
| Power Consumption | 1.8 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1080 × 850 × 1440 mm |
| Net Weight | 280 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZHPW-70 (Heating-only), ZQPW-70 (Heating & Refrigeration) |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 10–400 rpm |
| Amplitude | 26 mm |
| Temperature Range | 4–65 °C (ZQPW-70), RT+5–65 °C (ZHPW-70) |
| Platform Quantity | 1 |
| Uniformity | ±0.8 °C at 37 °C |
| Stability | ±0.3 °C at 37 °C |
| Platform Size | 520 × 430 mm |
| Max Load Capacity | 100 mL × 42 / 250 mL × 30 / 500 mL × 20 / 1000 mL × 9 |
| Power | 0.4 kW (ZHPW-70), 0.71 kW (ZQPW-70) |
| Input | AC 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 860 × 680 × 570 mm |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQP-100D |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 30–400 rpm |
| Amplitude | 0–50 mm (continuously adjustable) |
| Temperature Range | −10°C to 60°C (ambient-referenced) |
| Shelf Quantity | 1 |
| Chamber Volume | 100 L |
| Platform Dimensions | 400 × 370 mm |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Frequency Accuracy | ±1 rpm |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 0.8 kW |
| External Dimensions (W×D×H) | 550 × 780 × 640 mm |
| Capacity | 100 mL × 23, or 250 mL × 16, or 500 mL × 9, or 1 L × 5, or 2 L × 4 |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQP-100G |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–9999 min |
| Oscillation Frequency | 30–600 rpm |
| Orbit Diameter (Amplitude) | Φ0–50 mm (infinitely adjustable) |
| Temperature Range | Ambient +5°C to 60°C |
| Shelf Quantity | 1 platform |
| Platform Dimensions | 400 × 370 mm |
| Chamber Volume | 100 L |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 0.8 kW |
| External Dimensions (W×D×H) | 550 × 780 × 640 mm |
| Temperature Uniformity | ±0.3°C (at 37°C) |
| Temperature Stability | ±0.3°C (at 37°C) |
| Temperature Resolution | 0.1°C |
| Display | LCD touchscreen interface |
| Drive System | Brushless DC servo motor with bidirectional programmable control |
| Safety Features | Door-activated stop, over-temperature alarm & auto-shutoff, current overload protection, power failure memory, self-diagnostic system |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200 |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–9999 h |
| Oscillation Speed | 10–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Stability | ±0.3 °C (at 37 °C) |
| Control Method | PID Microprocessor-Based |
| Chamber Material | Stainless Steel Mirror Finish |
| Viewing Window | Tempered Double-Glass Door with Side Ø30 mm Access Port |
| Lighting | Integrated LED Illumination |
| Cooling System | R134a-Free Compressor with Thermal Protection Circuitry |
| Air Circulation | Centrifugal Forced-Air Duct System |
| Drive Mechanism | Brushless Servo Motor with Three-Eccentric-Cam Transmission |
| Safety Features | Door-Interlocked Stop, Over-Temperature Audiovisual Alarm + Auto-Cutout, Motor Overcurrent Protection, Self-Diagnostic Fault Detection |
| Programming | Bidirectional Rotation (Forward/Reverse/Stop), Multi-Stage Time-Programmable Speed & Temp Profiles |
| Display Options | LCD or True-Color Touchscreen Controller |
| Memory Function | Power-Failure Resume with Data Retention |
| Shelf Configuration | Dual-Deck Platform (Upper: Universal Spring Clamp |
| Lower | Fixed 500 mL × 12 Fixture) |
| Platform Dimensions | 439 × 528 mm per deck |
| Max Load Capacity per Deck | 100 mL × 42 / 250 mL × 25 / 500 mL × 16 / 1000 mL × 9 / 2000 mL × 6 |
| Rated Power | 11.3 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 740 × 730 × 1235 mm |
| Net Weight | 170 kg |
| Operating Ambient | 5–25 °C, 50% RH (20 °C baseline test condition) |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200A |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Control Method | PID Microprocessor |
| Shelving | Dual-tier platform (2 shelves) |
| Shelf Dimensions | 439 × 528 mm each |
| Capacity per Shelf | 100 mL × 25 / 250 mL × 20 / 500 mL × 12 / 1000 mL × 6 / 2000 mL × 4 |
| Standard Fixture Configuration | Lower shelf with fixed 500 mL clamps (×12), upper shelf with universal spring clamps |
| Power Consumption | 1.3 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 740 × 780 × 1260 mm |
| Net Weight | 170 kg |
| Display | 7-inch 16-bit true-color touchscreen interface |
| Data Logging | Internal storage (1-year history), USB export (CSV/PDF), optional thermal printer output |
| Safety Features | Door-activated motor stop, overtemperature audiovisual alarm + auto cut-off, self-diagnostic system, keypad lock, power-fail memory |
| Optional Upgrades | Remote monitoring via mobile app (iOS/Android), external environmental temperature probe, UV sterilization module, interior LED illumination |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200G |
| Shaker Type | Full-Temperature Orbital Incubator with Integrated Illumination |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Oscillation Amplitude | Ø26 mm |
| Temperature Range | 4–65°C (dark) / 10–65°C (with illumination) |
| Number of Shaking Platforms | 2 |
| 光照 Intensity | 0–16,000 lx (standard), up to 30,000 lx (optional) |
| Temperature Resolution | ±0.1°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Platform Dimensions | 439 × 528 mm per shelf |
| Power Consumption | 1.3 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 740 × 780 × 1235 mm |
| Net Weight | 170 kg |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-200R |
| Temperature Range | 4–65 °C (CO₂ mode: 4–60 °C) |
| CO₂ Range | 0–20% |
| CO₂ Uniformity | ±0.1% |
| CO₂ Control Accuracy | ±0.1% |
| Oscillation Frequency | 30–300 rpm (±1 rpm) |
| Amplitude | 26 mm (Ø) |
| Timer Range | 0–999 h 59 min |
| Shelf Quantity | 2 |
| Shelf Dimensions | 439 × 528 mm |
| Temp. Uniformity | ±0.5 °C at 37 °C |
| Temp. Resolution | 0.1 °C |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 1.3 kW |
| Net Weight | 170 kg |
| External Dimensions (W×D×H) | 740 × 780 × 1260 mm |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-500 |
| Instrument Type | Full-Temperature Orbital Shaker / Incubator Shaker |
| Timer Range | 0–9999 min (up to 166.6 h) |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm / 50 mm |
| Temperature Range | 4–65 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Fluctuation | ±0.3 °C (at 37 °C) |
| Temperature Resolution | 0.1 °C |
| Control Method | PID Microprocessor-Based Control |
| Shelf Quantity | 2 adjustable platforms |
| Platform Dimensions | 830 × 508 mm per shelf |
| Power Consumption | 2.1 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1080 × 850 × 1440 mm |
| Net Weight | 300 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPL-500A |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Oscillation Amplitude | Ø26 mm (standard), 50 mm (optional) |
| Temperature Range | 4–65 °C |
| Number of Shaking Platforms | 2 |
| Platform Dimensions | 830 × 500 mm each |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Resolution | ±0.1 °C |
| Frequency Accuracy | ±1 rpm |
| Power Consumption | 2.1 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1080 × 850 × 1440 mm |
| Net Weight | 300 kg |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-70 |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–9999 min (configurable in minutes or hours) |
| Oscillation Speed | 10–400 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–65°C |
| Temperature Resolution | 0.1°C |
| Temp. Uniformity | ±0.5°C (at 37°C) |
| Temp. Stability | ±0.3°C (at 37°C) |
| Shelf Dimensions | 520 × 430 mm |
| Standard Capacity | 100 mL × 25 |
| Standard Fixture | Universal Spring Clamps |
| Power Consumption | 0.7 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 860 × 680 × 570 mm |
| Display | LCD with PID Microprocessor Control |
| Motor Type | Brushless DC Motor |
| Drive Mechanism | Multi-axis Integrated Eccentric Cam Drive |
| Safety Features | Door-Interlock Stop, Over-Temp Audio-Visual Alarm + Auto Cut-off, Self-Diagnostic System, Power-Fail Data Retention |
| Operating Ambient | 5–25°C |
| Cooling System | Imported CFC-Free Compressor with Optimized Heat Dissipation Architecture |
| Air Circulation | Forced Convection via Centrifugal Air Duct |
| Illumination | Built-in White LED Light |
| UV Sterilization Lamp | Integrated (254 nm) |
| Viewing Window | Tempered Double-Layer Hollow Glass Door with Ø30 mm Access Port |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-70/300 |
| Temperature Range | 4–65°C |
| Oscillation Frequency | 30–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm |
| Temperature Uniformity | ±0.8°C (at 37°C) |
| Temperature Stability | ±0.3°C (at 37°C) |
| Chamber Dimensions (W×D×H) | 940×570×680 mm |
| Shelf Size | 940×570 mm |
| Max Capacity | 5000 mL × 8 or 3000 mL × 11 or 2000 mL × 15 or 1000 mL × 28 or 500 mL × 45 or 250 mL × 66 or 100 mL × 84 |
| Standard Fixture | Universal spring clamps (for 1000 mL × 20) |
| Display | LCD with PID microprocessor control |
| Cooling System | Imported CFC-free compressor with dust-filtered forced-air circulation |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 1.5 kW |
| Timer Range | 0–9999 min |
| Programmable Modes | Forward rotation / Reverse rotation / Stop / Alternating sequence |
| Door Safety Interlock | Automatic oscillation halt upon door opening |
| Diagnostic Function | Self-diagnosis of temperature, motor, and system faults |
| Alarm | Audible/visual over-temperature alarm with auto cut-off |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-90 |
| Temperature Range | 4–65 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Resolution | 0.1 °C |
| Oscillation Frequency | 10–400 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Timer Range | 0–9999 min |
| Platform Dimensions | 520 × 430 mm |
| Standard Capacity | 100 mL × 25 |
| Power Consumption | 0.7 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 900 × 730 × 640 mm |
| Control System | 16-bit true-color touchscreen with PID algorithm |
| Data Storage | 1-year local history |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPW-90G |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Oscillation Frequency | 10–400 rpm |
| Oscillation Amplitude | Ø26 mm |
| Temperature Range (Dark) | 4–65°C |
| Temperature Range (Illuminated) | 10–65°C |
| Number of Shelving Plates | 1 |
| Illuminance Range (Standard) | 0–16,000 lx (multi-step adjustable) |
| Illuminance Range (Optional) | 0–30,000 lx |
| Temperature Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Control System | 16-bit true-color touchscreen HMI |
| Timer Range | 0–999 h 59 min |
| Power Consumption | 0.7 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 900 × 736 × 640 mm |
| Tray Dimensions | 520 × 430 mm |
| Standard Capacity Configurations | 100 mL × 25 |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-115 |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 1–9999 min (or hr) |
| Oscillation Frequency | 10–350 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Temperature Stability | ±0.3 °C (at 37 °C) |
| Shelf Quantity | 3 |
| Shelf Dimensions (W×D) | 580 × 460 mm |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 0.7 kW |
| External Dimensions (W×D×H) per Layer | 950 × 800 × 600 mm |
| Shelf Loading Capacity (per layer) | 100 mL × 53 / 250 mL × 30 / 500 mL × 20 / 1000 mL × 12 / 2000 mL × 8 / 3000 mL × 5 |
| Standard Control | LCD Display (optional: full-color touchscreen controller) |
| UV Sterilization | integrated |
| Door Safety Interlock | yes |
| Motor Type | brushless servo motor |
| Drive Mechanism | three-axis eccentric cam drive |
| Air Circulation | centrifugal forced-air system |
| Chamber Material | seamless mirror-finish stainless steel (304) |
| Viewing Window | tempered double-glazed glass with Ø30 mm access port |
| Lighting | internal LED illumination |
| Refrigeration | fluorine-free compressor with dust-filtered cooling circuit |
| Programmable Functions | bidirectional rotation (forward/reverse/stop), multi-segment timing, power-loss memory, self-diagnostic alerts, over-temperature audiovisual alarm & auto-shutdown |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-115S |
| Shaker Type | Full-Temperature Orbital Incubator Shaker |
| Timer Range | 0–9999 min (up to 166.6 h) |
| Oscillation Speed | 10–1200 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 3 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Stability | ±0.3 °C at 37 °C |
| Tray Dimensions | 580 × 460 mm |
| Capacity per Tray | 16 microplate clamps |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Power Consumption | 1 kW |
| External Dimensions (per unit) | 950 × 800 × 600 mm (W × D × H) |
| Tray Quantity | 1 per layer |
| Stackable Configurations | 1–3 layers |
| Refrigerant | Eco-friendly non-CFC compressor-based cooling system |
| Safety Features | Over-temperature alarm, auto power cutoff on fault, auto-restart after power recovery, door-open pause, UV sterilization module |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228A |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm / 50 mm |
| Temperature Range | 4–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C) |
| Control Method | PID Microprocessor |
| Shelf Dimensions | 850 × 530 mm |
| Single-Shelf Capacity | 100 mL × 95, 250 mL × 56, 500 mL × 38, 1000 mL × 22, or 2000 mL × 12 |
| Standard Shelf Load | 100 mL × 45, 250 mL × 28, 500 mL × 28, 1000 mL × 14, or 2000 mL × 9 |
| Power per Shelf | 1.5 kW |
| Voltage | AC 220 V ±10%, 50–60 Hz |
| Single-Shelf External Dimensions | 1368 × 900 × 600 mm |
| Net Weight per Shelf | 220 kg |
| Environmental Operating Range | 5–25 °C |
| Display | 7-inch 16-bit true-color touchscreen |
| Data Storage | 1-year history retention |
| Connectivity | USB data export, optional remote monitoring via mobile app |
| Safety Features | Door-safety interlock, over-temperature alarm & cutoff, self-diagnostic system, encrypted operation lock, condensate drainage port, IPX4-rated motor, double-layer waterproof baffle, UV sterilization lamp, integrated LED illumination |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228A |
| Temperature Range | 4–65°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Temperature Resolution | 0.1°C |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm / 50 mm |
| Timer Range | 0–999 h 59 min |
| Shelf Capacity (per layer) | 100 mL × 60, 250 mL × 28, 500 mL × 28, 1000 mL × 14, 2000 mL × 9, or 3000 mL × 8 |
| Shelf Dimensions | 930 × 530 mm |
| Power Consumption (per layer) | 1.5 kW |
| Display | 7-inch 16-bit true-color touchscreen |
| Control Modes | Constant-value & programmable operation |
| Data Storage | 1-year history with USB export & real-time curve printing |
| Safety Features | Door-interlocked stop, over-temperature alarm & auto-shutdown, waterproof motor, triple liquid containment system, environmental temperature monitoring, PID control, UV sterilization & internal lighting |
| Optional Upgrades | CO₂ integration, remote mobile APP monitoring, external thermal printer |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228G |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | Ø26 mm |
| Temperature Range (Dark) | 4–65 °C |
| Temperature Range (Illuminated) | 10–65 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Control Method | PID Microcomputer |
| Illuminance | 0–16,000 lx (standard), optional 0–30,000 lx |
| Shelf Dimensions | 850 × 530 mm |
| Single-Shelf Capacity | 100 mL × 95, 250 mL × 56, 500 mL × 38, 1000 mL × 22, or 2000 mL × 12 |
| Standard Configured Capacity per Shelf | 100 mL × 45, 250 mL × 28, 500 mL × 28, 1000 mL × 14, or 2000 mL × 9 |
| Power Consumption (per Shelf) | 1.5 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (per Shelf) | 1368 × 900 × 600 mm |
| Net Weight (per Shelf) | 220 kg |
| Display | 7-inch 16-bit true-color touchscreen |
| Data Storage | 1-year history retention |
| USB Export | Supported for data backup and printing |
| Environmental Monitoring | External ambient temperature probe included |
| Safety Features | Door-activated motor stop, over-temperature audiovisual alarm with auto-shutdown, self-diagnostic fault detection, waterproof motor, triple liquid containment system, UV sterilization lamp, LED full-spectrum illumination with multi-level intensity control |
| Brand | Labotery |
|---|---|
| Origin | Tianjin, China |
| Model | ZQPZ-228R |
| Shaker Type | Refrigerated/Heated Orbital Incubator Shaker |
| Timer Range | 0–999 h 59 min |
| Oscillation Frequency | 10–300 rpm (±1 rpm) |
| Orbit Diameter | Ø26 mm / 50 mm |
| Temperature Range | 4–65 °C (CO₂ mode: 4–60 °C) |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Stability | ±0.3 °C at 37 °C |
| Temperature Resolution | 0.1 °C |
| CO₂ Control Range | 0–20% |
| CO₂ Sensor | Imported NDIR (Non-Dispersive Infrared) |
| CO₂ Accuracy | ±0.1% |
| CO₂ Distribution Uniformity | ±0.1% |
| Shelf Dimensions | 930 × 530 mm |
| Single-Shelf Capacity | 100 mL × 60 / 250 mL × 45 / 500 mL × 28 / 1000 mL × 14 / 2000 mL × 15 / 3000 mL × 8 |
| Power Consumption (per shelf) | 1.5 kW |
| Input Voltage | AC 220 V ±10%, 50–60 Hz |
| External Dimensions (W×D×H) | 1450 × 920 × 600 mm |
| Display | 16-bit true-color touchscreen controller with real-time curve plotting, data logging (1-year retention), USB export, password lock, and audit-ready event logging |