RADOBIO
Filter
Showing 1–30 of 35 results
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AirGuard1000 |
| Cleanliness Class | ISO 5 (Class 100) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Single-person, single-open-face |
| Average Air Velocity | 0.3–0.6 m/s |
| Illuminance | ≥300 lx |
| UV Sterilization | Integrated germicidal lamp |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 250 W |
| Work Area Dimensions (W×D×H) | 870 × 690 × 520 mm |
| Overall Dimensions (W×D×H) | 1010 × 725 × 1625 mm |
| Net Weight | 130 kg |
| Microbial Contamination | ≤0.5 CFU/plate·hour (Φ90 mm settle plate) |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AirGuard1500 |
| Price | Upon Request |
| Cleanliness Class | ISO 5 (Class 100) |
| Noise Level | ≤62 dB(A) |
| Operator Capacity | Dual-Operator, Single-Face Configuration |
| Brand | RADOBIO |
|---|---|
| Model | AirSafe 1300A2 |
| Safety Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1300 × 810 × 2290 mm |
| Internal Dimensions (L×W×H) | 1180 × 580 × 798 mm |
| ULPA Filter Efficiency | ≥99.9995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | <65 dB(A) |
| Vibration at Work Surface Center | ≤5 µm |
| Lighting Illuminance | ≥900 lx |
| UV Lamp | 30 W × 1 |
| Fluorescent Lamp | 18 W × 1 |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power (excl. outlet) | 0.33 kW |
| Max. Power (incl. outlet) | 1.65 kW |
| Net Weight | 268 kg |
| Compliance | YY 0569–2011, GB 4793.1, GB/T 18268.1 |
| Air Cleanliness Class | ISO 4 (equivalent to Federal Standard 209E Class 10) |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | AirSafe 1500A2 |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1500×810×2290 mm |
| Internal Dimensions (L×W×H) | 1380×580×798 mm |
| Filter Efficiency | ≥99.9995% @ 0.3 µm |
| Downflow Velocity | 0.35 m/s |
| Inflow Velocity | 0.55 m/s |
| Noise Level | <65 dB(A) |
| Vibration at Work Surface Center | ≤5 µm |
| Lighting Illuminance | ≥900 lx |
| UV Lamp | 30 W × 1 |
| Fluorescent Lamp | 18 W × 1 |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power (excl. outlet) | 0.33 kW |
| Max. Power (incl. outlet) | 1.65 kW |
| Net Weight | 312 kg |
| Compliance | YY 0569–2011, GB 4793.1, GB/T 18268.1 |
| Air Cleanliness Class | ISO 4 (equivalent to Fed Std 209E Class 10) |
| Personnel Protection | ≤10 CFU/plate (impactor), ≤5 CFU/plate (slit sampler) |
| Product Protection | ≤5 CFU/plate |
| Cross-Contamination Protection | ≤2 CFU/plate |
| Filter Type | ULPA (Ultra-Low Penetration Air) |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC) |
| Model | AirSafe 1800A2 |
| Cabinet Class | Class II, Type A2 |
| External Dimensions (L×W×H) | 1800 × 810 × 2290 mm |
| Internal Dimensions (L×W×H) | 1680 × 580 × 798 mm |
| Filter Efficiency | ≥99.9995% @ 0.3 µm |
| Supply & Exhaust Filter Type | ULPA |
| Air Cleanliness Class | ISO 4 (equivalent to Federal Standard 209E Class 10) |
| Inflow Velocity | 0.55 m/s |
| Downflow Velocity | 0.35 m/s |
| Noise Level | <65 dB(A) |
| Vibration at Work Surface Center | ≤5 µm |
| Personnel Protection | ≤10 CFU/plate (impactor), ≤5 CFU/plate (slit sampler) |
| Product Protection | ≤5 CFU/plate |
| Cross-Contamination Protection | ≤2 CFU/plate |
| Rated Power (excl. outlet) | 0.33 kW |
| Max. Power (incl. outlet) | 1.65 kW |
| Lighting | 18 W LED, ≥900 lx |
| UV Lamp | 30 W |
| Construction | Cold-rolled steel exterior (ivory white epoxy powder coating), 304 stainless steel work surface |
| Weight | 366 kg |
| Compliance | YY 0569–2011, GB 4793.1–2018, GB/T 18268.1–2018 |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C setpoint resolution |
| Temperature Uniformity | ±0.2°C (at 37°C, ambient 25°C, empty chamber) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% setpoint resolution |
| Chamber Capacity | 170 L |
| External Dimensions (L×W×H) | 702 × 690 × 896 mm (including base) |
| Key Configuration | PID control algorithm, 6-face direct-heating air jacket, 180°C dry-heat sterilization cycle |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor (Imported) |
| Temperature Range & Accuracy | Ambient +5°C to 60°C, ±0.1°C setpoint resolution |
| Temperature Uniformity | ±0.3°C (at 37°C, ambient 25°C, empty chamber) |
| CO₂ Concentration Range & Control Accuracy | 0–20%, ±0.1% |
| Chamber Volume | 185 L |
| External Dimensions (L×W×H) | 660 × 652 × 1000 mm (including base) |
| Heating Method | Six-Sided Direct-Heating Air Jacket |
| Sterilization | 140°C Dry-Heat Decontamination Cycle |
| Humidification | Removable 304 Stainless Steel Water Pan (4 L capacity) |
| Air Filtration | Internal HEPA Filter System (99.99% @ 0.3 µm) |
| Control Interface | 5-inch Capacitive Touch LCD Display |
| Data Logging | 250,000 entries, USB export, tamper-proof timestamped records |
| Power Supply | 220–240 V, 50–60 Hz |
| Weight | 108 kg |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4 °C to 60 °C, ±0.1 °C setpoint resolution |
| Temperature Uniformity | ±0.2 °C (at 37 °C, empty chamber, ambient 25 °C) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% setpoint resolution |
| Chamber Volume | 185 L |
| Internal Dimensions (L×W×H) | 535 × 526 × 675 mm |
| External Dimensions (L×W×H, incl. base) | 660 × 652 × 1000 mm |
| Sterilization Method | 140 °C Dry-Heat Sterilization |
| Humidification | Removable 304 Stainless Steel Water Pan (4 L capacity) |
| Air Filtration | Integrated HEPA Filter (≥99.99% @ 0.3 µm) |
| Control Interface | 5-inch Capacitive Touch LCD Display with Data Logging |
| Data Storage | 250,000 records, USB export, write-protected archival |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Resolution | Ambient +4 °C to 60 °C, 0.1 °C |
| Temperature Uniformity | ±0.2 °C (at 37 °C, empty chamber, ambient 25 °C) |
| CO₂ Concentration Control Range & Resolution | 0–20%, 0.1% |
| Chamber Volume | 248 L |
| Internal Dimensions (L×W×H) | 674 × 526 × 675 mm |
| External Dimensions (L×W×H) | 800 × 652 × 1000 mm (including base) |
| Standard Configuration | PID temperature control, 6-surface direct-heating air-jacket design, 140 °C dry-heat sterilization cycle |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C setpoint resolution |
| Temperature Uniformity | ±0.2°C (at 37°C, empty chamber, ambient 25°C) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% setpoint resolution |
| Chamber Capacity | 85 L |
| Internal Dimensions (L×W×H) | 440 × 400 × 500 mm |
| External Dimensions (L×W×H, including base) | 567 × 528 × 832 mm |
| Key Configuration | PID temperature control, 6-sided direct-heating air-jacketed design, 140°C dry-heat sterilization cycle |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Herocell 180 |
| Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C setpoint resolution |
| Temperature Uniformity | ±0.2°C (at 37°C, empty chamber, ambient 25°C) |
| CO₂ Concentration Range & Accuracy | 0–20%, ±0.1% setpoint resolution |
| Chamber Volume | 185 L |
| Internal Dimensions (L×W×H) | 535 × 526 × 675 mm |
| External Dimensions (L×W×H) | 660 × 652 × 1000 mm (incl. base) |
| Standard Configuration | PID temperature control, 6-sided direct-heating air jacket, 140°C dry-heat sterilization cycle |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Herocell 180CC |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C setpoint resolution |
| Temperature Uniformity | ±0.2°C (at 37°C, empty chamber, ambient 25°C) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% setpoint resolution |
| Chamber Capacity | 185 L |
| Internal Dimensions (L×W×H) | 535 × 526 × 675 mm |
| External Dimensions (L×W×H, including base) | 660 × 652 × 1000 mm |
| Key Configuration | PID temperature control, 6-face direct-heating air jacket, 140°C dry-heat sterilization, HEPA filtration, copper-coated 304 stainless steel interior |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Herocell 180E |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C setpoint resolution |
| Temperature Uniformity | ±0.2°C (at 37°C, empty chamber, ambient 25°C) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% setpoint resolution |
| Chamber Capacity | 185 L |
| Internal Dimensions (L×W×H) | 535 × 526 × 675 mm |
| External Dimensions (L×W×H, including base) | 660 × 652 × 1000 mm |
| Standard Configuration | PID control algorithm, 6-surface direct-heating air jacket, 180°C dry-heat sterilization, HEPA filtration system |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Herocell 180P |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Resolution | Ambient +4°C to 60°C, 0.1°C |
| Temperature Uniformity | ±0.2°C (at 37°C, empty chamber, ambient 25°C) |
| CO₂ Concentration Control Range & Resolution | 0–20%, 0.1% |
| Chamber Capacity | 185 L |
| External Dimensions (L×W×H) | 660 × 652 × 1000 mm (including base) |
| Key Configuration | PID control algorithm, 6-sided direct-heating air jacket, 180°C dry-heat sterilization cycle |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4 °C to 60 °C, ±0.1 °C |
| Temperature Uniformity | ±0.2 °C (at 25 °C ambient, 37 °C setpoint, empty chamber) |
| CO₂ Concentration Control Range & Accuracy | 0–20 %, ±0.1 % |
| Chamber Volume | 248 L |
| Internal Dimensions (L×W×H) | 674 × 526 × 675 mm |
| External Dimensions (L×W×H, including base) | 800 × 652 × 1000 mm |
| Key Configuration | PID control algorithm, 6-surface direct-heating air jacket, 140 °C dry-heat sterilization cycle |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Herocell 240MD |
| Instrument Type | Air-Jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C setpoint resolution |
| Temperature Uniformity | ±0.2°C (at 37°C, ambient 25°C, empty chamber) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% setpoint resolution |
| Chamber Capacity | 248 L |
| Internal Dimensions (L×W×H) | 674 × 526 × 675 mm |
| External Dimensions (L×W×H, including base) | 800 × 652 × 1000 mm |
| Heating Method | 6-Side Direct Electric Heating |
| Sterilization | 140°C Dry-Heat Cycle |
| Humidification | Removable 304 Stainless Steel Water Pan (4 L capacity) |
| Air Filtration | Internal HEPA Filter (99.99% @ 0.3 µm), <5 min full chamber air exchange post-door opening |
| Control Interface | 5-inch Capacitive Touch LCD Display with PID Algorithm |
| Data Logging | 250,000 entries, adjustable interval (30 s – 9999 s), USB export, immutable audit trail |
| Power Supply | 220–240 V, 50–60 Hz |
| Weight | 116 kg |
| Door Configuration | Six independent tempered glass inner doors, left-hinged standard (right-hinge optional) |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Resolution | Ambient +4°C to 60°C, 0.1°C |
| Temperature Uniformity | ±0.2°C (at 37°C, empty chamber, ambient 25°C) |
| CO₂ Concentration Control Range & Resolution | 0–20%, 0.1% |
| Chamber Capacity | 248 L |
| External Dimensions (L×W×H) | 800 × 652 × 1000 mm (including base) |
| Key Configuration | PID control, 6-sided direct-heating air jacket, 180°C dry-heat sterilization |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Herocell 80 |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C |
| Temperature Uniformity | ±0.2°C (at 25°C ambient, 37°C setpoint, empty chamber) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% |
| Capacity | 85 L |
| Internal Dimensions (L×W×H) | 440 × 400 × 500 mm |
| External Dimensions (L×W×H) | 567 × 528 × 832 mm (including base) |
| Standard Configuration | PID control algorithm, 6-sided direct-heating air jacket, 140°C dry-heat sterilization cycle |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Herocell 80P |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +4°C to 60°C, ±0.1°C |
| Temperature Uniformity | ±0.2°C (at 25°C ambient, 37°C setpoint, empty chamber) |
| CO₂ Concentration Control Range & Accuracy | 0–20%, ±0.1% |
| Chamber Capacity | 85 L |
| External Dimensions (L×W×H) | 567 × 528 × 832 mm (including base) |
| Standard Configuration | PID control algorithm, 6-surface direct-heating air jacket, 180°C dry-heat sterilization |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Herocell C1 |
| Instrument Type | CO₂-Regulated Orbital Shaker Incubator |
| Temperature Range | 4–60 °C |
| Timing Range | 0–999.9 h |
| Orbit Diameter Options | 25 mm / 26 mm / 50 mm (custom orbits available) |
| Display | 7″ LCD Touchscreen |
| CO₂ Control Range | 0–20% (IR sensor) |
| CO₂ Accuracy | ±0.1% |
| Temp Uniformity | ±0.3 °C at 37 °C |
| Max Load Capacity | 50 kg per deck |
| Power | 1300 W |
| Internal Volume | 365 L |
| Dimensions (W×D×H) | 1330×820×620 mm (single unit, incl. base) |
| Weight | 220 kg (single unit) |
| Brand | RADOBIO |
|---|---|
| Model | Herocell C1S |
| Instrument Type | CO₂-Controlled Orbital Incubator Shaker |
| Temperature Range | 4–60 °C |
| Timing Range | 0–999.9 h |
| Orbit Diameter Options | 25 mm / 26 mm / 50 mm (customizable) |
| CO₂ Control Range | 0–20% (IR sensor-based) |
| CO₂ Accuracy | ±0.1% |
| Temperature Uniformity | ±0.3 °C at 37 °C |
| Speed Range | 2–300 rpm |
| Speed Accuracy | ±1 rpm |
| Display | 7-inch LCD touchscreen |
| Max Load Capacity | 35 kg per deck |
| Internal Volume | 215 L |
| Power Supply | 220–240 V, 50–60 Hz |
| Max Power Consumption | 1300 W |
| Data Storage | 800,000 records (configurable interval: 30–9999 s) |
| Optional Features | Remote monitoring module, humidity control, pull-out light-shielding curtain, heated glass door, liquid drain port |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Herocell Max |
| Instrument Type | CO₂-Controlled Temperature-Shaking Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Amplitude Options | 25 mm / 26 mm / 50 mm (custom amplitudes available) |
| Temperature Control Range | 4 °C to 60 °C |
| Brand | RADOBIO |
|---|---|
| Model | Herotherm 170R |
| Origin | Shanghai, China |
| Temperature Range | 4°C to 60°C |
| Temperature Setting Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Chamber Volume | 171 L |
| External Dimensions (W×D×H) | 600 × 730 × 929.5 mm (incl. leveling feet) |
| Internal Dimensions (W×D×H) | 510 × 561 × 658.5 mm |
| Power Consumption | ≤1000 W |
| Control Interface | LCD Touchscreen |
| Temperature Control Algorithm | PID |
| Illumination | Optional Fluorescent Lamp (30 W), Configurable Cold White / Warm White Combination |
| Sterilization | Integrated UV-C Germicidal Lamp |
| Safety Features | Power-Fail Memory, Over-Temp/Under-Temp Alarm, Auto-Recovery, Dual-Glass Door with Insulated Air Gap |
| Operating Ambient | 10°C–35°C |
| Power Supply | 220–240 VAC, 50–60 Hz |
| Net Weight | 106 kg |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Herotherm 180 |
| Capacity | 180 L |
| External Dimensions (W×D×H) | 656 × 646 × 850 mm (including base) |
| Internal Chamber Dimensions (W×D×H) | 525 × 535 × 675 mm |
| Temperature Range | Ambient +5°C to 60°C |
| Temperature Setting Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Power Consumption | Max 300 W |
| Operating Environment | 10–30°C ambient |
| Weight | 63 kg |
| Control Interface | Button-operated LCD display |
| Temperature Control Algorithm | PID-based |
| Timer Function | 0–999.9 hours |
| Standard Shelving | 3 adjustable stainless-steel trays |
| Safety Features | Over-temperature alarm, power-failure memory, auto-restart with event logging, visual/audible deviation alert |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Hispeed CS3 |
| Instrument Type | Stacked Temperature-Controlled CO₂ Shaker Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Amplitude | 3 mm |
| Temperature Range | 4°C to 60°C |
| Number of Shaking Platforms | 2 |
| Max Speed | 1000 rpm |
| CO₂ Control Range | 0–20% (IR sensor) |
| CO₂ Stability | <1% deviation over 2 years |
| Platform Dimensions | 288 × 404 mm |
| Max Load per Platform | 15 kg |
| Display | 7-inch LCD touchscreen |
| Data Storage Capacity | 800,000 records |
| UV Sterilization System | Dual-position IR-safe UV lamps with door-interlocked safety cutoff |
| Chamber Volume | 215 L |
| Power Supply | 220–240 V, 50–60 Hz |
| Weight (single unit) | 160 kg |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | HiSpeed S3 |
| Instrument Type | Stackable Temperature-Controlled Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Amplitude | 3 mm |
| Temperature Range | 4 °C to 60 °C |
| Number of Shaking Platforms | 2 |
| Speed Range (Empty Load) | 2–1000 rpm |
| Speed Accuracy | ±1 rpm |
| Temperature Setting Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C (at 37 °C, ambient 25 °C, empty) |
| Platform Dimensions | 288 × 404 mm |
| Max Load per Platform | 15 kg |
| Deep-Well Plate Capacity | 32 plates |
| Internal Volume | 215 L |
| Power Consumption | 1550 W |
| External Dimensions (Single Unit) | 1000 × 725 × 620 mm (L×W×H, incl. base) |
| Net Weight | 160 kg |
| Interface | 7-inch horizontal LCD touchscreen |
| Data Logging | 250,000 records, interval adjustable from 30 s to 9999 s |
| Programs | 5 user-defined, up to 30 segments each |
| Compliance | Designed for GLP-compliant labs |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Stab L1T |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Amplitude | 26 mm or 50 mm (custom amplitudes available) |
| Temperature Range | 4 °C to 60 °C |
| Display | 7-inch vertical LCD touch screen |
| Control Precision | ±0.1 °C temperature setting, ±1 rpm speed control |
| Uniformity | ±0.5 °C at 37 °C |
| Chamber Volume | 450 L |
| Max Load per Deck | 50 kg |
| Deck Dimensions | 520 × 880 mm |
| Internal Dimensions | 1050 × 730 × 595 mm (L×W×H) |
| Power Consumption | 1400 W max |
| Data Storage | 250,000 records (configurable logging interval: 30 s – 9999 s) |
| Programs | 5 stored, up to 30 segments per program |
| Safety Features | Door-activated soft-stop/soft-start, auto-restart after power failure with event log, over-temp/over-speed alarm, UV sterilization module |
| Construction | Seamless brushed 304 stainless steel interior, double-glazed tempered glass door with optional anti-fog heating |
| Noise Level | <55 dB(A) at full load and 300 rpm |
| Stackable Configuration | Single unit (Stab L1T), dual-stack (Stab L1T-2), or upper-layer add-on (Stab L1T-D2) |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Stab M1T |
| Instrument Type | Full-temperature orbital shaker incubator |
| Timer Range | 0–999.9 h |
| Oscillation Amplitude | 25 / 26 / 50 mm (customizable) |
| Temperature Range | 4°C to 60°C |
| Control Interface | 7-inch vertical LCD touch screen |
| Speed Range | 2–300 rpm |
| Speed Accuracy | ±1 rpm |
| Temperature Setting Resolution | 0.1°C |
| Temperature Uniformity | ±0.5°C at 37°C |
| Tray Dimensions | 520 × 880 mm |
| Max Load Capacity (per layer) | 50 kg |
| Internal Volume | 370 L |
| Power Consumption | 1400 W max |
| Data Storage | 250,000 records |
| Programmable Segments | Up to 30 per program (5 programs total) |
| Data Export | USB port |
| Noise Level | <55 dB(A) |
| Construction | Seamless brushed 304 stainless steel interior chamber |
| Safety Features | Door-interlocked UV lamp, soft-start/stop oscillation, auto-restart after power failure, over-temp/over-speed alarm |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Stab Max |
| Instrument Type | CO₂-Compatible Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 2–300 rpm |
| Amplitude Options | 26 mm or 50 mm (custom amplitudes available) |
| Temperature Range | 4 °C to 60 °C |
| Control Interface | Button-Operated LCD Display |
| Speed Accuracy | ±1 rpm |
| Temperature Setpoint Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Chamber Volume | 300 L |
| Internal Dimensions (W×D×H) | 638 × 620 × 690 mm |
| External Dimensions (W×D×H) | 710 × 775 × 1080 mm (incl. leveling feet) |
| Max Load Capacity | 35 kg per shelf |
| Power Consumption | 1300 W max |
| Operating Ambient | 5–35 °C |
| Voltage/Frequency | 220–240 V / 50–60 Hz |
| Net Weight | 170 kg |
| Data Logging | 250,000 records (interval: 30 s – 9999 s) |
| Stored Programs | 5 (up to 30 segments each) |
| Illumination | 30 W fluorescent lamp |
| Sterilization | UV-C germicidal lamp (254 nm) |
| Safety Certifications | Compliant with IEC 61010-1 for laboratory equipment |
| Brand | RADOBIO |
|---|---|
| Origin | Shanghai, China |
| Model | Stab MaxT |
| Instrument Type | Full-Temperature Orbital Shaker Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Amplitude Options | 26 mm / 50 mm (custom amplitudes available) |
| Temperature Range | 4 °C to 60 °C |
| Control Interface | LCD Touchscreen |
| Speed Range (Empty Load) | 2–300 rpm |
| Speed Accuracy | ±1 rpm |
| Temperature Setting Resolution | 0.1 °C |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Chamber Volume | 300 L |
| Internal Dimensions (L×W×H) | 638 × 620 × 690 mm |
| External Dimensions (L×W×H) | 710 × 775 × 1080 mm |
| Net Weight | 170 kg |
| Max Load per Shelf | 35 kg |
| Shelf Size | 500 × 500 mm |
| Power Consumption | 1300 W |
| Data Storage Capacity | 250,000 records |
| Data Logging Interval | 30 s – 9999 s (configurable) |
| Programmable Protocols | 5 stored protocols, up to 30 segments each |
| UV Sterilization | Integrated UV-C lamp |
| Lighting | 30 W fluorescent tube |
| Safety Features | Auto-braking on door opening, power-loss parameter retention, over-temperature/over-speed alarm, PID-based thermal control |
| Optional Accessories | Retractable light-blocking curtain, heated glass door, USB data export port |