Schütz / SIGAS
Filter
Showing all 13 results
| Brand | Schutz SIGAS |
|---|---|
| Origin | Germany |
| Model | CoMo 170 Portable High-Sensitivity Alpha/Beta/Gamma Surface Contamination Monitor |
| Detector Type | Plastic Scintillation Detector (Alpha/Beta/Gamma Sensitive) |
| Detection Area | 170 cm² |
| Measurement Units | cps, Bq, Bq/cm² |
| Power Supply | Rechargeable Battery (Portable Operation) |
| Compliance | CE, DIN 6818-1, IEC 60846-1 |
| Optional Accessories | External GM Dose Rate Probe, Desktop Stand, Data Export Software |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | FLOWEVO |
| Pricing | Upon Request |
| Detection Principle | Non-Dispersive Infrared (NDIR), Dual-Beam |
| Gas Targets | Methyl Bromide (CH₃Br), Sulfuryl Fluoride (SO₂F₂) |
| Response Time (T90) | ≤12 s @ 0.7 L/min |
| Resolution (@ zero) | 1 ppm to 0.1 vol.% |
| LOD (3σ) | ≤1% FS |
| Repeatability | ≤±1% FS |
| Linearity Error | ≤±1.0% FS (standard), ≤±1.5% FS (select versions) |
| Zero Drift | ≤±2% FS over 12 months |
| Span Drift | ≤±2% FS over 12 months |
| Temp. Drift (Zero) | ≤±0.1% FS/°C |
| Temp. Drift (Span) | ≤±0.15% FS/°C |
| Pressure Drift | 0.1–0.2% reading/mbar |
| Operating Temp. | 0–50°C |
| Storage Temp. | −20–60°C |
| Humidity | 0–95% RH (non-condensing) |
| Pressure Range | 800–1200 mbar |
| Warm-up Time | <2 min (cold start), <30 min (full spec.) |
| Flow Rate | 0.1–1.0 L/min (stable) |
| Digital Output | Modbus ASCII RTU (TTL, 2400–115.2 kbaud, auto-baud/auto-frame) |
| Analog Output (optional w/ FLOWEVO plus controller) | 4–20 mA, 0–1 V, 0–5 V, 0–10 V DC |
| Signal Output | TTL-level single-channel |
| Chamber Pressure Compensation | Active |
| Heating | Integrated active heating for condensation & drift mitigation |
| Supply Voltage | 3.3–6 V DC ±5% (sensor only) |
| Current Draw | <240 mA @ 5 V (avg., no heating) |
| Power Consumption | <800 mW (no heating) |
| Housing | Anodized aluminum |
| Inlet Connection | 3 mm ID / 5 mm OD flexible tubing |
| Expected Service Life | ≥10 years |
| Maintenance Requirement | Minimal (no consumables, no chemical degradation) |
| Brand | Schutz SIGAS |
|---|---|
| Origin | Germany |
| Type | Portable |
| Detector | Energy-Compensated Geiger-Müller Tube |
| Radiation Types | Simultaneous γ and X-ray Measurement |
| Display | Dual LCD with backlight (dose & dose rate) |
| Dose Range | 0.5 µSv to 1 Sv |
| Dose Rate Range | 0.5 µSv/h to 50 mSv/h |
| Environmental Dose Equivalent | H*(10) and Ḣ*(10) |
| IP Rating | IP54 |
| Dimensions | 28 × 67 × 105 mm |
| Weight | ~200 g (with batteries) |
| Data Logging | Internal non-volatile memory |
| Alarm Thresholds | 4 factory-preset, user-adjustable |
| External Probe Interface | Yes (e.g., ABG170, ZP1083D, NaI-2002) |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | S-ANALYZER 200 BMBT |
| Price Range | USD 5,600–8,400 (FOB) |
| Response Time | <25 s (at 60 L/h stable flow) |
| Warm-up Time | 3–30 min (at 20°C, dependent on detector configuration) |
| O₂ Resolution | 0.001% (BMBT O₂ channel) |
| CO/CO₂/CH₄ Resolution | 0.1 µmol/mol |
| Display | 5.6" Touchscreen LCD |
| Analog Output | 4–20 mA (normal operation), 2 mA (alarm/preheat) |
| Digital Outputs | 6 configurable relay channels (fault, auto-calibration control, concentration high/low alarms) |
| Communication | RS232 (DB9 female), RS485 Modbus RTU |
| Power Supply | 198–242 V AC, 50/60 Hz, <125 W |
| Enclosure Rating | IP41 (IEC 60529) |
| Weight | ~10 kg (net), ~19 kg (packed) |
| Sample Flow Rate | 0.2–1.2 L/min (±0.02 L/min stability required) |
| Sample Temperature | 5–35 °C |
| Sample Pressure | ≤116 kPa (abs) |
| Sample Humidity | Non-condensing |
| Particulate Load | ≤100 µg/m³, particle size ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |
| Brand | Schütz / SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | S-ANALYZER 200 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Accuracy | ±<2% FS |
| Repeatability | ≤±1% FS |
| Response Time | T90 < 2 s (at 60 L/h sample flow) |
| Long-Term Stability | <2% FS drift over 30 days |
| Gas Components | SO₂, NOₓ, CO, CO₂ (up to 7 components total) |
| Display | 7-inch capacitive touchscreen with triple-screen interface |
| Calibration Options | Zero, span, and third-point calibration (35–75% FS) |
| Language Support | English & Chinese |
| Enclosure | 19-inch rack-mount chassis (4U height) |
| Compliance | Designed for ISO 14001-aligned monitoring |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | S-ANALYZER 200 V5.0 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Number of Channels | Up to 5 Simultaneous Gas Components |
| Measurement Range (Min) | 0–50 ppm |
| Repeatability | ±1% FS |
| Resolution | 0.1 ppm |
| Response Time (T90) | <2 s at 60 L/h flow rate |
| Zero Drift | <±1% FS / 7 days |
| Span Drift | <±1% FS / 7 days |
| Linearity Error | <±2% FS |
| Operating Flow Rate | 0.2–1.2 L/min (±0.02 L/min stability required) |
| Inlet Temperature | 5–35 °C |
| Inlet Pressure | ≤116 kPa (abs) |
| Inlet Humidity | Non-condensing |
| Particulate Load | ≤100 µg/m³, particle size ≤1 µm |
| Display | 5.6" TFT LCD touch screen |
| Analog Output | 4–20 mA (configurable), 2 mA fault signal |
| Digital Communication | RS232 (DB9 female), RS485 Modbus RTU |
| Relay Outputs | 6 configurable dry-contact relays (1 A @ 250 V AC / 2 A resistive) |
| Power Supply | 198–242 V AC, 50/60 Hz, <125 W |
| Enclosure Rating | IP41 (EN 60529) |
| Weight | ~10 kg (net), ~19 kg (packaged) |
| Calibration Gases | Zero gas — 99.999% N₂ |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | S-ANALYZER 200 NDUV |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Non-Dispersive Ultraviolet (NDUV) Absorption |
| Maximum Permissible Error | ≤ ±2% FS |
| Zero Drift | ≤ ±2% FS / 24 h |
| Span Drift | ≤ ±2% FS / month |
| Repeatability | ≤ ±1% FS |
| Response Time | <25 s (at 60 L/h stable flow) |
| Warm-up Time | 3–30 min (at 20°C, depending on detector configuration) |
| Resolution | 0.01% (O₂ channel), 0.1 µmol/mol (for SO₂/NO/NO₂/etc.) |
| Operating Flow Rate | (0.2–1.2) L/min (±0.02 L/min stability required) |
| Inlet Temperature | 5–35°C |
| Inlet Pressure | ≤116 kPa |
| Dew Point | 5°C ±0.1°C (mandatory for SO₂/NO channels) |
| Particulate Load | ≤100 µg/m³, ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |
| Analog Output | 4–20 mA (normal operation), 2 mA (fault/alarm/preheat) |
| Digital Outputs | 6 relay channels (configurable for fault, auto-calibration control, and concentration alarms) |
| Communication | RS232 (DB9 female), RS485 Modbus RTU |
| Power Supply | 198–242 V AC, 50/60 Hz, <125 W |
| Enclosure Rating | IP41 (EN 60529) |
| Weight | ~10 kg (net), ~19 kg (packaged) |
| Display | 5.6" color LCD touchscreen with tri-screen interface (numerical status, detailed parameters, real-time concentration curves) |
| Brand | Schutz SIGAS |
|---|---|
| Origin | Germany |
| Model | GPD150G |
| Instrument Type | Portable Dose/Dose Rate Meter |
| Detector Type | Energy-Compensated Geiger-Müller Tube |
| Measured Quantity | Hp(10) (Deep Personal Dose) |
| Radiation Type | Gamma and X-ray |
| Energy Range | 55 keV – 1.3 MeV |
| Dose Range | 1 µSv – 10 Sv |
| Protection Rating | IP54 |
| Battery Life | Up to 3 months (8 h/day) under ambient background radiation |
| Alarm Functions | Audible, visual, and vibration alerts for dose & dose rate thresholds |
| Predefined Warning Levels | Four user-selectable dose thresholds + one factory-set dose rate threshold |
| Data Retention | Persistent memory during battery replacement |
| Operating Mode | Single-pulse acoustic detection (switchable) |
| Accessories | Belt clip and protective holster |
| Compliance | Designed in accordance with IEC 61526:2010 and IEC 62387-1:2012 for personal dosimetry |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | SPGAS PORT 110 |
| Type | Portable |
| Response Time | <30 s (t₉₀ @ 36 L/h stable flow) |
| Repeatability | H₂S, SO₂F₂, CH₃Br, CO, CO₂, O₂, etc. |
| Measurement Channels | Up to 3 |
| Display | 4.9" TFT LCD |
| Power | Rechargeable Li-ion battery (≥8 h operation @25°C) |
| Communication | RS232 (DB-9F), USB, optional Bluetooth 2.0 (10 m range, BQB/FCC certified) |
| Safety Certifications | UL 62368-1, CSA C22.2 No. 62368-1, TÜV EN 62368-1, CCC GB4943.1 |
| Preheat Time | NDUV ≤1 h, NDIR ≤15 min, EC ≤10 min (cold start @25°C) |
| Sampling Flow | 3 ± 0.5 L/min (integrated low-noise diaphragm pump) |
| Operating Temp | 5–40°C (measurement), 0–45°C (charging) |
| Humidity | 0–95% RH (non-condensing) |
| Pressure Range | 76–116 kPa |
| Sample Gas Requirements | 5–40°C, no condensate, particulates <100 µg/m³ (<1 µm), external filtration recommended |
| Data Storage | Internal memory + USB export (FAT32, up to 16 GB) |
| Brand | Schütz / SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPGAS PORT mini |
| Price | Upon Request |
| Measurement Channels | 3 |
| Sensor Technologies | NDIR, Electrochemical (EC), and other modular principles |
| Display | 4.9" TFT LCD |
| Response Time (t₉₀) | <30 s @ 36 L/h stable flow |
| Sampling Flow Rate | 3 ± 0.5 L/min (integrated low-noise diaphragm pump) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | –20–60 °C |
| Battery Life | ≥8 h (fully charged, 25 °C) |
| Charging Time | ~5 h (5% to 90%, 25 °C) |
| Power Input | 100–260 VAC, 47–63 Hz |
| DC Output | 24 VDC, 0–6 A |
| Safety Certifications | UL 62368-1, CSA C22.2 No. 62368-1, TÜV EN 62368-1, CCC GB4943.1 |
| Preheat Time | ≤15 min (NDIR), ≤10 min (EC), cold start @25 °C |
| Ingress Protection | IP54 (enclosure) |
| Data Interface | RS232 (DB9-F), USB Type-A, optional Bluetooth 2.0 (2.4 GHz, ~10 m line-of-sight, BQB/FCC certified) |
| Data Export | FAT32-formatted USB flash drive (up to 16 GB) |
| Display Resolution | 0.1 g/m³ |
| Alarm Outputs | Relay & visual/audible alerts |
| Zero Calibration | One-button auto-zero, configurable auto-zero on power-up |
| Internal Filtration | Integrated particulate and hydrophobic protection filter |
| Gas Inlet | 1/8" NPT female |
| Sample Gas Requirements | 5–40 °C, non-condensing, particulates <100 µg/m³ (<1 µm), external filtration recommended for harsh environments |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Germany |
| Model | SPTr-GAS PORT 100 |
| Type | Portable Analyzer |
| Response Time | ≤10 s |
| Target Gases | Sulfuryl Fluoride (SO₂F₂), Methyl Bromide (CH₃Br), Phosphine (PH₃), Ethylene Oxide (C₂H₄O) |
| Repeatability | ±2% of reading (for SO₂F₂, CH₃Br, PH₃) |
| Calibration | Auto-zero and manual zero options |
| Display | Integrated touchscreen interface with analog + digital readout |
| Compliance | Designed for field-deployable fumigant residue verification per ISPM No. 18, EN 14603, and EPA Method TO-15 derivations |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Germany |
| Model | SPTr-GAS PORT 200 |
| Type | Portable Multicomponent Gas Analyzer |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Response Time | ≤10 s |
| Repeatability | ±1% FS for SO₂F₂ and CH₃Br |
| Detection Gases | Sulfuryl Fluoride (SO₂F₂), Methyl Bromide (CH₃Br), Phosphine (PH₃) |
| Measurement Ranges | SO₂F₂: 1–150 g/m³ (PRO) / 0.5–200 ppm (CLIR) |
| CH₃Br & PH₃ | matching trace/high-range configurations |
| Accuracy | ±1% FS (full scale) or ±0.5 ppm (<10 ppm) |
| Resolution | 0.1 g/m³ (PRO) / 0.5 ppm (CLIR) |
| Warm-up Time | 5 min (PRO) / 15 min (CLIR) |
| Display | 1×8-character LCD |
| Power Supply | NiMH Battery Pack (19.2 V, 72 Ah) |
| AC Input | 100–240 VAC, 47–64 Hz, max. 110 W |
| Battery Runtime | >26 h (PRO) / >5 h (CLIR) |
| Charging Time | 3.5 h |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | −10 °C to +60 °C |
| Relative Humidity | 0–95% RH, non-condensing |
| Dimensions | 230 × 105 × 270 mm |
| Weight | 3.5 kg (PRO) / 4.3 kg (CLIR) |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | SPTr-GAS® ANALYZER |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Typical LOD | < 0.01 % FS |
| Response Time (T90) | < 20 s |
| Warm-up Time | ~15 min to 50 °C at 20 °C ambient |
| Display | 5.6" Touchscreen LCD |
| Analog Output | 4–20 mA (configurable range), 2 mA fault signal |
| Digital I/O | 6 relay outputs (programmable per channel) |
| Communication | RS232 (DB9-M), RS485 Modbus RTU |
| Power Supply | 198–242 V AC, 50/60 Hz, < 125 W |
| Enclosure Rating | IP41 (EN 60529) |
| Weight | ~10 kg (net), ~19 kg (packaged) |
| Sample Flow Rate | 0.2–1.2 L/min (±0.02 L/min stability required) |
| Inlet Temp | 5–35 °C |
| Inlet Pressure | ≤116 kPa |
| Inlet Humidity | Non-condensing |
| Particulate Load | ≤100 µg/m³, ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |