SIGAS (Schütz Mess- und Regeltechnik)
Filter
Showing all 5 results
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AGSS |
| Pricing | Available Upon Request |
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Switzerland |
| Model | Foxsense MULTi 2000 Plus |
| Form Factor | Rack-Mount (19" 3U) |
| Channel Configuration | Single or Dual Channel |
| Enclosure Options | IP20 (bare rack unit) or IP52 (enclosed rack version) |
| Dimensions (IP20) | 482 × 133 × 245 mm |
| Dimensions (IP52) | 500 × 143 × 260 mm |
| Response Time (T90) | ≤30 s |
| Measured Gases | CH₄, CO₂, CO, O₂ |
| Gas Sampling | Continuous online flow-through |
| Compliance | Designed for industrial process monitoring and biogas quality control per EN 16726, ISO 8573-1 (compressed air purity), and applicable IEC 61000-6-2/4 EMC standards |
| Regulatory Context | Supports GLP/GMP-aligned data integrity when integrated with audit-trail-enabled SCADA or DCS systems |
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Switzerland |
| Model | Foxsense PAROX 2000 Plus |
| Measurement Principle | High-Sensitivity Paramagnetic Detection |
| Operating Temperature Range | Up to 55°C continuous |
| Enclosure | 19" 3U Rack-Mounted |
| Dimensions (W×H×D) | 482 × 133 × 245 mm |
| IP Rating | IP20 |
| Sensor Core | Integrated Parox1200 Paramagnetic Sensor |
| Calibration | Fully Parameterized Auto-Calibration |
| Channel Configuration | Single or Dual (MULTI2000Plus option) |
| Gas Path Materials | Viton® or PVDF |
| Gas Inlet/Outlet | 4 mm or 6 mm PVDF tubing with stainless steel compression fittings |
| Pressure Compensation Options | None / Electronic / Integrated Pressure Regulator / External Pressure Input (sensor not included) |
| Flow Monitoring Options | None / Mechanical Flowmeter / Electronic Flowmeter with Display & Alarm |
| Oxygen Range Options | 0–25% O₂ |
| Pump Options | None / Integrated Sampling Pump |
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Germany |
| Model | AGS 35-50 |
| Supply Configuration | Dual-bank cylinder auto-switching with priority liquid oxygen inlet (AGS 80P compatible) |
| Pressure Monitoring | Continuous real-time differential pressure sensing |
| Control Logic | Automatic switchover triggered by user-defined high/low pressure thresholds |
| Compliance | Designed to meet ISO 8573-1 (compressed air quality), EN ISO 7396-1 (medical gas pipeline systems), and IEC 60601-1 (medical electrical equipment safety) |
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Germany |
| Model | Silarex |
| Detection Principle | Dual-Beam Non-Dispersive Infrared (NDIR) |
| Measurement Range | CO₂ up to 20 vol.%, CO up to 1000 ppm, NO up to 2000 ppm, SO₂ up to 1000 ppm |
| Response Time (T90) | < 8 s @ 0.7 L/min |
| Repeatability | ≤ ±1 % FS |
| Linearity Error | ≤ ±1 % FS (standard), ≤ ±1.5 % FS (select versions) |
| Stability | < ±2 % FS over 1000 h |
| Operating Temperature | 0–40 °C (up to 45 °C with thermostatic housing) |
| Storage Temperature | −20–60 °C |
| Humidity | 0–95 % RH (non-condensing) |
| Pressure Range | 800–1150 mbar |
| Flow Rate | 0.2–1.0 L/min (stable) |
| Warm-up Time | < 2 min (cold start), < 30 min (full thermal stabilization) |
| Power Supply | 24 VDC ±0.3 V |
| Max. Current Draw | 1.5 A (heating chamber active) |
| Heating Setpoint | 42 °C (sensor core), 45 °C (with aluminum thermostatic housing) |
| Digital Interface | Modbus ASCII/RTU over TTL, auto-baud & auto-frame |
| Gas Inlet | 3 mm ID / 5 mm OD tubing connection |
| Optical Cell | Gold-coated reflective chamber |
| Cross-Interference Suppression | Engineered spectral deconvolution and multi-wavelength compensation |
| Zero-Point Resolution | CO₂ 0.01 vol.%, CO 0.1 ppm, NO 1 ppm, SO₂ 1 ppm |
| LOD | CO₂ 0.1 %FS, CO 0.5 %FS, NO 1 %FS, SO₂ 1 %FS |