SIGAS
Filter
Showing all 19 results
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CMGS-2000 Series |
| Pricing | Available Upon Request |
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Product Type | Medical humidification and suction system |
| Model | SIGAS Humidification & Suction Device |
| Compliance | CE-marked per MDR 2017/745 |
| Vacuum Range | 0–80 kPa (0–0.8 bar) |
| Operating Pressure | 400–600 kPa compressed air supply |
| Humidification Principle | Bubble-through immersion tube with multi-orifice diffusion |
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Model | SIGAS-MAD Series |
| Type | Twin-Tower Desiccant Air Dryer |
| Inlet Pressure Range | 6–10 bar(g) |
| Dew Point | ≤ −40 °C (at pressure) |
| Flow Capacity | 10–2000 Nm³/h |
| Filtration Stages | Pre-filter (ISO 8573-1 Class 2, 2, 2), Coalescing + Activated Carbon Post-filter (Class 1, 1, 1) |
| Regeneration Method | Purge-air (heatless) or Blower-assisted (optional) |
| Compliance | ISO 8573-1:2010, ISO 7396-1:2016, EN 13544-1:2021, DIN SPEC 5000-2, VDI 2083 Part 10 |
| Brand | SIGAS |
|---|---|
| Origin | Switzerland |
| Model | PAROX 1200 |
| Measurement Principle | Paramagnetic Detection |
| O₂ Range Options | 0–25 %, 0–100 %, or Custom (e.g., 0–x %, x–100 %) |
| Output Signals | 0–1 V, 0–4 V, 4–20 mA |
| Gas Inlet Ports | 3 mm, 1/8", or 5 mm internal thread |
| Flow Requirements | Direct flow (10–150 mL/h), Internal fixed bypass (17–70 L/h), External flow control (10–90 L/h, optional module) |
| Gas Preheating | Optional integrated heater |
| Lifetime | >5 years typical operational service life under specified conditions |
| Cross-sensitivity | Negligible to CO₂, N₂, Ar, CH₄, H₂O (vapor), and common industrial gases |
| Operating Temperature | -10 °C to +50 °C |
| Enclosure Rating | IP65 |
| Compliance | CE, RoHS, ATEX Category 3G (optional variant) |
| Brand | SIGAS |
|---|---|
| Model | S-ANALYZER ATEX V5.0 |
| Type | Online Industrial Explosion-Proof Multicomponent Gas Analyzer |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Channels | Up to 5 simultaneous gas measurements |
| Response Time | <25 s (t90 @ 60 L/h constant flow) |
| Repeatability | CH₄, CO, CO₂, O₂, and other supported gases |
| Enclosure Rating | Ex d IIC T6 Gb (certified per GB3836.1–2010 & GB3836.2–2010, NEPSI certified) |
| Operating Temperature | 5–45 °C |
| Inlet Flow Rate | 0.4–0.8 L/min (±0.02 L/min stability) |
| Power Supply | (198–242) V AC, 50/60 Hz, <125 W |
| Weight | ~50 kg |
| Dimensions | Not specified in input |
| Analog Output | 4–20 mA (2 mA fault signal), load: 250–350 Ω |
| Relay Outputs | 6 configurable dry-contact relays (1 A @ 250 V AC / 2 A resistive) |
| Gas Inlet | NPT 1/8″ female |
| Moisture Requirement | Non-condensing |
| Particulate Limit | ≤100 µg/m³, ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas Range | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |
| Ingress Protection | Not explicitly stated |
| Compliance | GB3836.1/2–2010, NEPSI-certified, suitable for Zone 1/21 hazardous areas |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | S-Handheld 10 |
| Pricing | Upon Request |
| Detection Principles | Infrared (NDIR), Electrochemical, PID, Catalytic Bead |
| Sensor Lifespan | Electrochemical: 2–3 years |
| NDIR | 5–10 years |
| Catalytic Bead | ~3 years |
| PID | 2–3 years |
| Response Time (T90) | ≤60 s |
| Operating Temperature | 5–45 °C |
| Relative Humidity Range | 10–95 %RH (non-condensing) |
| Barometric Pressure Measurement | 300–1100 hPa (±1 hPa accuracy) |
| Power Supply | 5 VDC, rechargeable 6800 mAh Li-ion battery |
| Runtime | Up to 8 h (pump-on continuous operation) |
| Display | 4.3″ TFT-LCD, 800 × 480 resolution |
| Sampling Method | Integrated active pump, 300 mL/min flow rate |
| Filtration | Built-in hydrophobic particulate filter and water trap |
| Data Storage | 100,000 records (concentration + timestamp + alarm flags) |
| Connectivity | USB Type-C (data transfer & charging), optional Bluetooth 5.0 |
| Dimensions | 217 × 92 × 80 mm (L × W × H) |
| Weight | ~850 g |
| Alarm Types | Low/High, STEL, TWA |
| Certifications | CE, RoHS, IP65-rated enclosure |
| Compliance | Designed for alignment with ISO 10156, IEC 60079-0/-11 (for intrinsic safety configurations), and applicable regional occupational exposure standards (e.g., OSHA PELs, ACGIH TLVs) |
| Brand | SIGAS |
|---|---|
| Model | S-Infra.Sens |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| T90 Response Time | < 3 s @ 1 L/min |
| Digital Resolution | 1 ppm to 0.1 vol.% |
| Accuracy (3σ) | ±0.5% FS |
| Repeatability | ±1% FS |
| Linearity | ±1% FS |
| Zero Stability | ±1% FS / 30 days |
| Span Stability | ±1% FS / 30 days |
| Zero Temp. Drift | ±1% FS / 10 K |
| Span Temp. Drift | ±1% FS / 10 K |
| Pressure Drift | ±0.015% / mbar |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −10–60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Ambient Pressure | 800–1200 mbar |
| Warm-up Time | < 10 min |
| Power-On Time | < 2 min |
| Sample Gas Temperature | +5–35 °C |
| Sample Gas Humidity | ≤10 °C dew point (non-condensing) |
| Flow Rate | 0.2–1 L/min (stable) |
| Output Interfaces | RS232 (9-pin Sub-D), CANopen, Optional Analog (0–10 V / 4–20 mA) |
| Supply Voltage | 24 VDC ±0.3 V |
| Power Consumption | 2 W (typ., without heater) |
| Optical Path Length | 5–250 mm (modular) |
| Housing Material | Aluminum or Stainless Steel (optional) |
| Cell Wall Coating | Gold-plated (optional, for enhanced reflectivity) |
| Response Time (Signal Rise) | ≈200 ms |
| Power Consumption (Sensor Only) | < 1 W |
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Model | S-MODULE BasicEVO |
| Detection Principle | Non-Dispersive Infrared (NDIR), Dual-Beam |
| Measurement Range | See Standard Model List |
| Sampling Method | Diffusion |
| Response Time (T90) | ≤30 s |
| Resolution (@zero) | 1 ppm to 0.1 vol.% |
| LOD (3σ) | ≤±1 % FS |
| Repeatability | ≤±1.5 % FS |
| Linearity Error | ≤±2 % FS |
| Zero Stability | ≤±3.0 % FS / 12 months (typ.) |
| Span Stability | ≤±2.5 % FS / 12 months (typ.) |
| Zero Temp. Drift | ≤±0.15 % FS / °C (typ.) |
| Span Temp. Drift | ≤±0.3 % FS / °C (typ.) |
| Pressure Drift | ±0.1–0.2 % of reading per mbar |
| Operating Temp. | –20 °C to +40 °C (model-dependent) |
| Storage Temp. | –20 °C to +60 °C |
| Humidity | 0–95 % RH (non-condensing) |
| Pressure Range | 800–1150 mbar |
| Warm-up Time | <2 min (cold start), <11 min (slow start), <30 min (full spec.) |
| Digital Output | Modbus ASCII/RTU over TTL, auto-baud (2400–115.2 kbps) |
| Analog Outputs | 0/4–20 mA (with S-Connect), 0/0.2–1 V (with S-Connect V), RS-232/RS-485 (with respective S-Connect modules) |
| Supply Voltage | 3.3–6 VDC ±5 % |
| Avg. Current Draw | 120 mA @5 VDC, peak <400 mA @3.3 VDC / <240 mA @5 VDC |
| Power Consumption | <0.8 W (avg.) |
| Brand | SIGAS |
|---|---|
| Model | S-MODULE EVO |
| Detection Principle | Non-Dispersive Infrared (NDIR), Dual-Beam |
| Measurement Range | Configurable per gas (e.g., CO₂: 100 ppm to 100% vol |
| CO | 2,000 ppm to 100% vol |
| CH₄ | 5,000 ppm to 100% vol |
| SF₆ | 50 ppm to 100% vol |
| SO₂ | 2,000 ppm |
| N₂O | 500 ppm) |
| Operating Temperature | 0 °C to 50 °C |
| Storage Temperature | −20 °C to 60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Pressure Range | 800–1200 mbar |
| Response Time (T90) | <3 sec (Fast Mode), <14 sec (Standard Mode) |
| Zero Drift | ≤ ±2% FS / 12 months |
| Span Drift | ≤ ±2% FS / 12 months |
| Temperature Drift (Zero) | ≤ ±0.1% FS/°C |
| Temperature Drift (Span) | ≤ ±0.15% FS/°C |
| Pressure Drift | 0.1–0.2% of reading per mbar |
| Power Supply | 10–26 VDC (recommended 24 VDC) |
| Digital Output | RS232, RS485, Modbus ASCII/RTU, EVO-proprietary protocols |
| Analog Output Options | 0/4–20 mA (isolated), 0–1/2/5/10 VDC |
| Flow Rate | 0.1–1.0 L/min (pump-suction) |
| Tubing Connection | 3 mm ID / 5 mm OD |
| Housing | Anodized aluminum with integrated thermal insulation and optional active heating |
| Gas Cell | Gold-coated, temperature-stabilized |
| Pressure Compensation | Optional internal chamber or ambient pressure compensation |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | S-SYSTEM CEMS |
| Detection Gases | Flue Gas |
| Accuracy | ±1% FS |
| Response Time | T90 < 2 s at 60 L/h flow |
| Warm-up Time | ~2 min |
| Resolution | 0.01 ppm |
| Linearity Error | ≤ ±2% FS to ±5% FS |
| Zero Calibration | Clean Air |
| Inlet Gas Temperature Range | 5–30 °C |
| Display Units | ppm, mg/m³ |
| Output Signals | 4–20 mA, RS485 |
| Enclosure Rating | IP42 (EN 60529) |
| Brand | SIGAS |
|---|---|
| Model | S-UltraSense |
| Origin | Germany |
| Detection Principle | Non-Dispersive Ultraviolet (NDUV) Absorption |
| Measurable Gases | NO, NO₂, SO₂, O₃, H₂S, N₂O, CnHm |
| Detection Range Options | 0–100 ppm to 0–30,000 ppm (gas-specific) |
| LOD | 1 ppm (typical, 3σ) |
| T₉₀ Response Time | <3 s @ 1 L/min |
| Operating Temperature | 10–40 °C |
| Power Supply | 24 VDC ±0.3 V |
| Average Power Consumption | 4 W (55 W max during warm-up) |
| Digital Resolution | 1 ppm – 0.1 vol.% |
| Zero Stability | ±1% FS |
| Span Stability | ±1% FS |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Temperature Drift | ±1% FS / 10 K (typ.) |
| Pressure Sensitivity | ±0.015% / mbar |
| Inlet Gas Temp. | −2–40 °C |
| Inlet Humidity Limit | dew point ≤10 °C (non-condensing) |
| Flow Rate | 0.2–1 L/min |
| Output Interfaces | RS232 (9-pin Sub-D), CANopen (2×5-pin, 2.45 mm pitch) |
| Heater Setpoint | 42 °C |
| Warm-up Time | <60 min (environment-dependent), <30 min @ 20 °C ambient |
| Ready Time after Power-On | <2 min (post-warm-up) |
| Housing Material | Stainless Steel with Protective Coating |
| Optical Path Length | 100 mm |
| Light Source | AlGaN-based UV LED (230–360 nm) with Active Thermal & Current Control |
| Lifetime | >3 years (LED source) |
| Sealing | O-ring interconnection between modular components |
| Cross-Interference Immunity | H₂O-free baseline stability |
| Power Dissipation | <1 W (sensor core only) |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | SA-200 TCD |
| Detection Principle | Thermal Conductivity Detection (TCD) |
| Measuring Range | H₂ 0–99.999 vol% (configurable per background gas) |
| Accuracy | ±2% FS |
| Repeatability | ±1% FS |
| Stability | ±1% FS / 7 days |
| Response Time (T90) | <30 s |
| Display | 240×128 LCD |
| Data Storage | SD card (standard), USB flash drive (optional) |
| Output | 4–20 mA (default), configurable to 0–20 mA / 0–1 V / 0–5 V / 0–10 V / 1–5 V |
| Communication | RS485 (standard), RS232 (optional) |
| Power Supply | 85–264 VAC, 50/60 Hz |
| Power Consumption | <35 VA |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | <80% RH |
| Sample Flow Rate | 200–400 mL/min |
| Sample Pressure | Ambient ±10% (at outlet) |
| Inlet/Outlet Port | 1/4" NPT internal thread, stainless steel |
| Enclosure Dimensions | 483 × 300 × 177 mm (L×W×H) |
| Mounting | Panel mount, cutout 445 × 180 mm (rectangular), fixing holes Φ6 × 4 at 465 × 101.5 mm |
| Brand | SIGAS |
|---|---|
| Model | SA-TR96/91 |
| Detection Principle | Electrochemical & Frequency-Modulated Ion Current |
| Measurement Range | 0–10 ppm to 0–25% O₂ (selectable) |
| Accuracy | ±1% FS (0–1000 ppm and above), ±3% FS (0–100 ppm), ±5% FS (0–10 ppm) |
| Repeatability & Stability | ±1% FS (≥100 ppm), ±1.5% FS (0–100 ppm), ±2.5% FS (0–10 ppm) |
| Response Time (T90) | <60 s at 25°C |
| Recovery Time (20.94% → 10 ppm) | ≤60 min |
| Operating Pressure | 35–210 kPa (absolute), flow-controlled at 1.0–1.5 L/min (recommended: 1.2 L/min) |
| Ambient Temp. | 0–45°C |
| Humidity | <80% RH |
| Power Supply | 85–264 VAC, 50/60 Hz, <20 VA |
| Output Signals | Isolated 4–20 mA (configurable to 0–20 mA / 0–1 V / 0–5 V / 0–10 V / 1–5 V) |
| Communication | RS485 (standard), RS232 (optional) |
| Gas Inlet | 1/8″ stainless steel |
| Enclosure Dimensions | 144 × 144 × 251 mm (L×W×D) |
| Mounting Hole Pattern | 136 × 136 mm |
| Sensor Lifetime | >2 years (typical use) |
| Analyzer Lifetime | >5 years (typical use) |
| Compliance | Designed for continuous industrial gas monitoring per IEC 61000-6-2/6-4 EMI immunity & emission requirements |
| Certifications | CE-marked |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SGC-100 CEMS-VOC |
| Pricing | Upon Request |
| Brand | SIGAS |
|---|---|
| Model | SPM-O2-MODULE III |
| Detection Principle | Paramagnetic Oxygen Sensing |
| Measurement Range | 0–3 / 0–10 / 0–25 / 0–100 vol.% O₂ |
| Response Time (t₉₀) | ≤3 s |
| Zero Drift | <±0.1 % O₂/week |
| Span Drift | <±1 % O₂/week |
| Linearity Error | <±1 % FS |
| Detection Limit (3σ) | <1 % FS |
| Temperature Drift (Zero) | <±0.05 % O₂/°C |
| Flow Rate Dependence | <±0.2 % O₂ (20–100 mL/min) |
| Tilt Sensitivity | <±0.02 % O₂/degree |
| Humidity Influence | <0.5 % O₂ @ 20°C |
| Analog Output | 4–20 mA |
| Supply Voltage | 24 VDC |
| Inlet Flow Rate | 100 mL/min (optimal), max. 250 mL/min |
| Inlet Pressure Drop | ≤±300 hPa |
| Operating Temperature | 5–45 °C |
| Inlet Gas Dew Point | ≥5 °C |
| Particulate Limit | ≤100 µg/m³, particle size ≤1 µm (dust filter required) |
| Zero Calibration Gas | 99.999% N₂ |
| Span Calibration Gas | 85–110% of full scale (e.g., dry air for 0–25% range) |
| Brand | SIGAS |
|---|---|
| Model | SPTr-GAS® ANALYZER V3.0 |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Target Gases | NH₃, CH₃Br, C₂H₆O, C₃H₈O, CH₄O, SO₂, SF₆, C₂Cl₄, NF₃, N₂O, C₈H₈, C₂HCl₃F₂, C₂HCl₂F₃, CClF₃, CF₄, CHClF₂, CHF₃, C₂F₆, CCl₂F₂, C₂HCl₃, C₈H₂₀O₄Si, etc. |
| Response Time | < 20 s |
| Detection Limit | < 0.01 % FS (varies by range) |
| Measurement Range | Configurable per application (e.g., NH₃: 0–100 ppm or 0–1 g/m³ |
| CH₃Br | 0–2 g/m³) |
| Accuracy | ±0.1 % FS typical (±0.5 ppm for sub-ppm ranges) |
| Zero Stability | < 0.1 % FS/24 h |
| Operating Temperature | Maintained at 50 °C (±0.5 °C) internally |
| Humidity Compensation | Integrated IR humidity sensor inside PAS cell |
| Display | 5.6” resistive touchscreen LCD |
| Analog Output | 4–20 mA (2 mA fault signal) |
| Digital Interface | RS232 (9600 baud, 8N1) |
| Power | 198–242 V AC, 50/60 Hz |
| Weight | ~15 kg |
| Enclosure Rating | IP42 |
| Compliance | EN60320-C1 power inlet, EN60529, CE-marked |
| Brand | SIGAS |
|---|---|
| Model | SPTr-GAS® PORT 200 |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Dimensions (H×W×D, incl. handle & ports) | 230 mm × 105 mm × 270 mm |
| Weight | ~4.3 kg |
| Power Supply | Internal NiMH battery (19.2 V, 4.5 Ah) |
| Operating Time | >4 h (fully charged) |
| Charging Time | ~3.5 h |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | −10 °C to +60 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Display | 1×8-character LCD with red backlight |
| Accuracy | ±0.5 ppm (0–10 ppm range) |
| Resolution | 0.5 ppm (residual gas) |
| Integrated Compensation | Active temperature stabilization (50 °C heated PAS cell), real-time humidity sensing, multi-gas interference rejection via spectral signal discrimination |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | SPTr-GAS®300 Tracer |
| Type | Portable |
| Response Time | <20 s |
| Repeatability | ±0.1% FS for NH₃, CH₃Br, SO₂, etc. |
| Operating Temperature | 50 °C (thermostatically stabilized) |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Dimensions | 483 mm × 390 mm × 177 mm (19″ 1/2-rack form factor) |
| Weight | ~15 kg |
| Enclosure Rating | IP42 |
| Power Supply | 198–242 V AC, 50/60 Hz |
| Analog Output | 4–20 mA (250–350 Ω load) |
| Communication | RS223 (7-pin blue/black cable) |
| Preheat Time | ~30 min |
| Resolution | 0.1 ppm (typical, gas-dependent) |
| Zero Calibration | Auto or manual air-based calibration |
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Model | X5C Plus |
| Instrument Type | Portable Ambient Dose Equivalent Rate Meter (for H*(10)) |
| Detector Type | Energy-Compensated Geiger-Müller Tube |
| Measurement Quantity | Ambient Dose Equivalent Rate Ḣ*(10) and Integrated Dose H*(10) |
| Display | Backlit LCD with Logarithmic Bar Graph (3.5-decade) |
| Alarm | Programmable Acoustic/Visual Thresholds for Dose & Dose Rate |
| Data Logging | Time-Stamped Automatic & Manual Storage |
| Connectivity | RS-232 Interface |
| Enclosure | IP67-rated Metallized Plastic Housing |
| Dimensions | 152 × 82 × 39 mm |
| Weight | ~385 g |
| Dose Range | 0.5 µSv – 10 Sv |
| Dose Rate Range | 1 µSv/h – 19.99 mSv/h |
| Compliance | PTB-Type Approved (Germany) |