Chemical Analysis Instruments
Filter
Showing 7051–7080 of 10726 results
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | CF2000 |
| Maximum Rotational Speed | 6500 rpm |
| Separation Mechanism | Size-based and Density-based Fractionation |
| Application Focus | Nanomaterial Sizing, Branched vs. Linear Polymer Analysis in Aqueous and Organic Solvents |
| Instrument Type | Centrifugal Field Flow Fractionation System |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | EAF2000 |
| Instrument Type | Asymmetric Flow Field-Flow Fractionation (AF4) with Integrated Electric Field-Flow Fractionation (EF4) |
| Operating Solvent Compatibility | Aqueous only |
| Channel Configuration | Dual-field, orthogonal separation channel module |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | GF2000 GS |
| Separation Mode | Gravitational Sedimentation FFF |
| Core Technology | SPLITT (Split Flow Thin Cell Fractionation) |
| Channel Configuration | Horizontal, Membrane-Free, Stationary-Phase-Free |
| Applicable Sample States | Aqueous or Low-Viscosity Suspensions |
| Typical Particle Size Range | 10 nm – 100 µm (dependent on density contrast and flow conditions) |
| Max. Sample Concentration | ≤ 5% w/v (varies by particle density and dispersibility) |
| Flow Rate Range | 0.1–5.0 mL/min (per inlet) |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | SC2000 |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.001–9.995 mL/min |
| Pump Pressure Limit | 40 MPa |
| RI Detector Drift | 1 × 10⁻⁷ RIU/h |
| RI Detector Cell Volume | 8 µL |
| UV Detector Wavelength Range | 190–800 nm |
| UV Detector Noise | ±0.3 × 10⁻⁵ AU |
| Column Oven Temperature Range | +5 °C to +90 °C |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | TF 2000 |
| Field Type | Thermal |
| Instrument Category | Field Flow Fractionation (FFF) |
| Regulatory Class | Imported Analytical Instrument for Macromolecular & Nanoparticle Characterization |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | FJ3003 |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Analog Input Channels | 2 (auto-ranging: ±0.2 V, ±2 V, ±20 V) |
| Input Impedance | >10 MΩ |
| Sampling Rate | 100 MS/s |
| Display & Measurement Resolution | 4 significant digits |
| Temperature Measurement Accuracy | ±0.01 °C |
| Temperature Control Range | 15 °C above ambient to 100 °C |
| Temperature Setpoint Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Output Actuation | Zero-crossing triggered thyristor |
| Control Output | 5-step power output (max. 300 W) |
| Electrical Isolation | Analog-to-digital and overvoltage protection integrated |
| Compliance | Designed for academic lab environments |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JH11X |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Potentiostatic Range | ±2 V |
| Current Range | ±2 mA / ±20 mA (dual-range) |
| Potential Resolution | 0.001 V |
| Current Resolution | 0.001 mA |
| Reference Electrode Input Impedance | ≥10¹² Ω |
| Cell Voltage Range | ±13 V |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 320 × 215 × 130 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PPM150 |
| Price Range | USD 2,700 – 6,800 |
| Light Sources | 9 high-stability LEDs |
| Wavelengths | 380, 430, 470, 500, 520, 560, 610, 700, 810 nm |
| Absorbance Range | −0.5 to 4.0 AU |
| Photometric Accuracy | ±1.5% of reading |
| Absorbance Precision | ±0.03 AU |
| Wavelength Accuracy | ±2 nm |
| Sample Cell | 16 mm round cuvette with light-blocking cap |
| Display | 128 × 64 pixel backlit monochrome LCD (60 × 40 mm) |
| Data Storage | 1,000 measurement records (date/time/wavelength/reagent/method/result/test ID) |
| Calibration Curves | Up to 150 preloaded or user-defined methods |
| Communication | IrDA infrared interface |
| Power Supply | 4 × AA rechargeable or alkaline batteries |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PRE-2000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.1–100 mL/min |
| Flow Accuracy | ±1.0% |
| Flow Precision | ≤0.2% RSD |
| Flow Reproducibility | ≤0.2% RSD |
| Maximum Pressure | 5000 psi |
| Wavelength Range | 190–800 nm (±1 nm) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤0.15 × 10⁻⁵ AU |
| Data Acquisition Rate | 100 Hz |
| Pump Configuration | Dual Isocratic or Gradient Capable |
| Gradient Composition Range | 0–100% B |
| Auto-Cleaning Pump Head | Integrated |
| Maintenance Interval | ≥6 months under continuous operation |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | 330XM |
| Heating Source | Halogen Lamp |
| Display | High-Contrast VFD Screen |
| Weighing System | Integrated 320XB Precision Electronic Balance |
| Sensor Technology | MFR Electromagnetic Force Restoration |
| Construction | Full Die-Cast Aluminum Housing |
| Calibration | External Calibration Mode |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ) |
| Regulatory Features | Real-Time Clock, Password Protection, Mechanical Safety Interlock |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | EM120-HR |
| Heating Source | Halogen Lamp |
| Display | Backlit LCD with Graphical Real-Time Moisture Trend Plot |
| Construction | Full Cast-Aluminum Housing |
| Calibration | Fully Automatic Smart Calibration System (SCS) |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ), GxP-Compliant Real-Time Clock, Multi-Level User Access Control with Password Protection |
| Software Features | Built-in Automatic Repeatability Test (ART), Checkweighing, Statistical Analysis |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM120 |
| Maximum Capacity | 124 g |
| Minimum Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Drying Time Range | 0.1–99.9 min |
| Termination Modes | Automatic, Semi-Automatic (Δdigit/sec or Δ%/sec), Fixed-Time |
| Data Output Interval | 0.1–10.0 min |
| Password Protection | Yes |
| Statistical Functions | Count, Mean, Max, Min, Standard Error |
| Interface | RS232 |
| Memory | 50 Method Programs, 999 Test Records |
| Preheating | 30–100 °C |
| Multi-Stage Heating | 3 programmable segments (temp + time per stage) |
| Boost Mode | 140% target temp for first 3 min |
| Firmware Update | Remote via network |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM60 |
| Maximum Capacity | 62 g |
| Minimum Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost Function (140% target temp for first 3 min) |
| Termination Modes | Automatic, Semi-Automatic (user-defined mass change per second), Timed (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Preset Methods | 5 |
| Security | Password Protection, Physical Lock Slot |
| Interface | RS232 |
| Firmware Update | Remote download via network |
| Brand | EXPECLIN / Puju Medical |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Model | PreMed 7000 |
| Pricing | Available Upon Request |
| Brand | Brechbühler |
|---|---|
| Origin | Switzerland |
| Model | Prep 9100 |
| Application | Olfactometric Fraction Collection |
| Capacity | 10 adsorption tubes per run |
| Interface | Direct coupling to Sniffer 9100 olfactometer and GC systems |
| Control | PC-based software with pneumatic tube switching |
| Adsorbent | Customized high-affinity sorbent cartridges (e.g., Tenax TA, Carbotrap, or mixed-bed configurations) |
| Compliance | Designed for GLP-compliant odor fractionation workflows |
| Brand | PREVAC |
|---|---|
| Origin | Poland |
| Model | HPPES |
| Pressure Range | 2×10⁻⁹ mbar – 50 mbar |
| Base Pressure (UHV mode) | ≤1×10⁻⁹ mbar (configuration-dependent) |
| Sample Temperature Range | 20 K (LHe/LN₂-cooled) to 1400 °C |
| Analyzer Type | High-Pressure Hemispherical Energy Analyzer (EA15-HP5 / EA15-HP50) |
| X-ray Sources | Dual-anode monochromated AlKα / AgLα and non-monochromated AlKα / MgKα |
| UV Source | Powered He(I)/He(II) discharge lamp |
| Ion Source | Broad-beam Ar⁺ for sputter depth profiling or surface cleaning |
| Neutralizer | Electron flood gun |
| Manipulator | Motorized or manual 4–6 axis, with precise angular and translational control |
| Load-Lock Chamber | Integrated, with linear transfer to analysis chamber |
| Vacuum System | Composite pumping stack including roughing pump, turbomolecular pump (TMP), titanium sublimation pump (TSP), and cryo-shielded ion pump |
| Software Platform | Spectrium (Tango-compatible, PLC-integrated) |
| Compliance | UHV/HPXPS/APXPS/UPS/ARPES/AES/EELS/ISS/IPES/LEIPS standards |
| Brand | PREVAC |
|---|---|
| Origin | Poland |
| Model | PES |
| Base Pressure | ≤1×10⁻¹¹ mbar |
| Analysis Chamber Diameter | Ø310 mm |
| Sample Temperature Range | 20 K (LHe) to 1400 °C |
| Sample Manipulator | 4–6-axis motorized |
| Energy Analyzer | Hemispherical EA15 UHV |
| X-ray Sources | Monochromated dual-anode (AlKα/AgLα) and non-monochromated dual-anode (AlKα/MgKα) |
| UV Source | Powered He-I (21.2 eV) and He-II (40.8 eV) lamps |
| Flood Gun | Electron flood source for charge neutralization |
| Ion Sources | Ar⁺ sputter gun and gas cluster ion beam (GCIB) for depth profiling/cleaning |
| Optional Add-ons | LEED, RGA, IPES/LEIPS, AES, EELS, ISS modules |
| Control Software | Spectrium (Tango-compliant, PLC-integrated) |
| Vacuum System | Composite pumping stack including roughing pump, turbomolecular pump (TMP), ion pump, and titanium sublimation pump (TSP) with LN₂ shroud |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Pri-eco |
| Country of Origin | Domestic (China) |
| Model | PRI-8400 |
| Price | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AMBA C123+N |
| Price | Upon Request |
| Measurement Principle | Mid-infrared quantum cascade laser absorption spectroscopy coupled with high-speed gas chromatography and micro-combustion |
| δ¹³C Precision (C₁–C₄) | <0.4‰ (1σ) |
| Sampling Frequency | 1 Hz |
| Cycle Time per Sample | ≤3 min (including C₁, C₂, C₃, and C₄ isotopic analysis) |
| Measurement Chamber Volume | <1 mL |
| Operating Pressure | 50 Torr |
| Concentration Range | CH₄ >0.5% v/v |
| Operating Temperature | 0–35 °C (above dew point) |
| Relative Humidity | <100% RH |
| Dimensions (Isotope Analyzer) | 740 × 465 × 357 mm (H) |
| Dimensions (Fast GC Module) | 675 × 558 × 370 mm (H) |
| Power Requirement | 110/220 V AC, 50/60 Hz |
| Peak Power | 3 kW |
| Average Power | 1 kW |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AMBA i3211 |
| Pricing | Available Upon Request |
| Measurement Principle | Mid-Infrared Hollow Waveguide Absorption Spectroscopy |
| Sample Chamber Volume | ~1 mL |
| δ¹³C Precision | <0.08‰ (1σ, 60 s) |
| CO₂ Concentration Range | 380–5000 ppm |
| Sampling Frequency | 4 Hz (high-speed mode), 1 Hz (standard mode) |
| Sample Flow Rate | 15 mL/min (standard), 5 mL/min (low-flow mode) |
| Sample Cell Volume | 0.1 mL |
| Operating Temperature | −10 to +45 °C |
| Vacuum Pump Capacity | 100 sccm at 50 Torr |
| Operating Pressure | 50–133 kPa |
| Relative Humidity Tolerance | <99% RH (non-condensing at ≤40 °C, no drying required) |
| Calibration | Fully Automated Online Calibration |
| Data Interfaces | RS-232, Ethernet, USB |
| Inlet/Outlet Fittings | 1/8″ Swagelok® Compression Ferrules |
| Dimensions (W×D×H) | 483 × 800 × 476 mm (19″ × 31.5″ × 18.75″) |
| Weight | 25 kg |
| Power Supply | 100–240 VAC, <350 W (startup), ~200 W (steady-state) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | EA-HWG |
| Price | Upon Request |
| δ¹³C Precision (1σ) | <0.1–0.2 ‰ |
| CO₂ Measurement Range | 380–10,000 ppmv |
| Measurement Frequency | 4 Hz |
| Sample Flow Rate | 0.5 mL/s |
| Measurement Cell Volume | <1 mL |
| Operating Temperature | −10 to 45 °C |
| Miniature Vacuum Pump | 100 sccm @ 50 Torr |
| Sampling Pressure | 50–133 kPa |
| Carrier Gas | Ultra-High-Purity N₂ or He |
| Combustion Gas | Ultra-High-Purity O₂ |
| Relative Humidity Tolerance | <99% RH (non-condensing at 40 °C) |
| Calibration | Fully Automated Online Calibration |
| Interface Options | RS-232, Ethernet, USB |
| Inlet/Outlet Fittings | 1/8″ Swagelok |
| Dimensions (CO₂ Analyzer) | 483 × 800 × 476 mm (W×D×H) |
| Weight | 25 kg |
| Dimensions (Elemental Analyzer) | 813 × 394 × 508 mm |
| Weight | 68 kg |
| Power Requirement | 100–240 VAC |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EA-IRMS-SCAR |
| Pricing | Upon Request |
| 14C Measurement Precision | 1–1.5 pMC @ 10 min |
| Measured Isotopes | ¹³C, ¹⁴C, ¹⁵N |
| Resolution (Central Collector) | 80 |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | EA-MIR |
| Pricing | Upon Request |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | EA-SCAR 14CO₂ |
| Quotation | Upon Request |
| Measurement Precision | 1–1.5 pMC @ 10 min |
| Isotope Measured | ¹⁴C in CO₂ |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 610 |
| Detection Elements | C, H, N, S, O |
| Principle | Dumas Flash Combustion + Gas Chromatographic Separation |
| Furnace Configuration | Dual-Furnace (Oxidation + Reduction) |
| Detector | Self-Calibrating TCD |
| Sample Mass Range | 0.01–100 mg |
| Detection Range | 200 ppm – 100% |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| LOD/LOQ | 1–5 µg |
| Oxidation Temp | 800–1100 °C |
| Reduction Temp | 600–1100 °C |
| Analysis Time (CHNS) | ~15 min |
| GC Column | 2 m packed column (CN separation) |
| Calibration Models | Linear, Quadratic, Cubic |
| Software | EAS CLARITY |
| Carrier Gas | Helium (99.999%, 3–5 bar) |
| Oxygen Supply | Ultra-High-Purity O₂ (99.999%, 3–5 bar) |
| Power | 230 VAC ±10%, 1–10 A |
| Dimensions (L×W×H) | 760 × 350 × 700 mm |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 624 |
| Detection Elements | C, H, N, S, O |
| Principle | Dumas flash combustion coupled with gas chromatographic separation |
| 炉 Design | Single-furnace (oxidation and reduction in one furnace) |
| Detector | TCD with auto-calibration |
| Sample Mass Range | 0.01–100 mg |
| Detection Range | 200 ppm – 100% |
| Accuracy | < 0.2% (vs. certified reference materials) |
| Precision | < 0.1% RSD (vs. certified reference materials) |
| LOD | 1–5 µg |
| Combustion/Reduction Temperature | 800–1100 °C |
| Analysis Time (CHNS) | ~15 min |
| GC Column Length | 2 m |
| Calibration Models | Linear, quadratic, cubic |
| Software | EAS CLARITY |
| Carrier Gas | Helium (99.999%, 3–5 bar) |
| Oxidant | Oxygen (99.999%, 3–5 bar) |
| Power Supply | 230 VAC ±10%, 1–10 A |
| Dimensions (L×W×H) | 760 × 350 × 700 mm |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 820 |
| Detection Elements | C, H, N, S, O |
| Sample Introduction | Pneumatic Auto-sampler (147 positions), Electric Auto-sampler (32/50/100 positions), Manual Sampler |
| Analysis Time | CN: 5 min |
| CHN | 8 min |
| CHNS | 10–25 min |
| O | 4 min |
| Measurement Range | C: 0.002–20 mg |
| H | 0.002–5 mg |
| N | 0.002–20 mg |
| S | 0.002–6 mg |
| O | 0.002–2 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% (certified reference materials, purity >99.9%) |
| Furnace Configuration | Dual independent high-temperature furnaces (max. 1100 °C each) |
| Separation Oven Temp. | up to 110 °C |
| Carrier Gas | Ultra-high-purity helium (99.999%, 3–5 bar) |
| Oxidant Gas | Ultra-high-purity oxygen (99.999%, 3–5 bar) |
| Auxiliary Gas | Oil-free compressed air |
| GC Column | 0.8–4 m capillary separation column |
| Detector | High-sensitivity TCD with auto-calibration (no reference gas required) |
| Flow Control | Electronic mass flow regulation |
| Leak Detection | Fully automated self-diagnostic leak test |
| Oxygen Delivery | Intelligent, sample-mass-dependent dosing |
| Software | EAS Clarity (supports linear, quadratic, and cubic calibration models) |
| Sample Mass Range | 0.1–500 mg (up to 1000 mg for soil) |
| Sample Cups | High-purity tin or silver capsules |
| Dimensions | 810 × 500 × 370 mm |
| Weight | 68 kg |
| Power Supply | 230 V, 50/60 Hz |
| Max. Power Consumption | 1100 W, 5 A |
| Touchscreen Interface | Integrated industrial-grade display |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | Element5 822 |
| Detection Elements | C, N |
| Sample Forms | Solid and Liquid |
| Combustion Configuration | Dual-Furnace (Oxidation + Reduction) |
| Detection Principle | Dumas Flash Combustion Coupled with Gas Chromatographic Separation and Thermal Conductivity Detection (TCD) |
| Automation Features | Automated Leak Detection, Intelligent Oxygen Dosage Control, Electronic Flow Regulation, Self-Calibrating TCD |
| Sample Capacity | Up to 147 positions (Pneumatic Autosampler) |
| Analysis Time per CN Run | ~5 min |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (Certified Reference Materials, Purity >99.9%) |
| Precision (RSD) | <0.1% (n ≥ 10, CRM) |
| Furnace Temp | Up to 1100 °C (Dual Independent Zones) |
| Separation Oven Temp | Up to 110 °C |
| Carrier Gas | Ultra-High-Purity Helium (99.999%, 3–5 bar) |
| Reactant Gas | Ultra-High-Purity Oxygen (99.999%, 3–5 bar) |
| Auxiliary Gas | Oil-Free Compressed Air |
| GC Column | 3 m Packed Capillary Column |
| Software | EAS Clarity v3.x (Compliant with FDA 21 CFR Part 11 Audit Trail & User Access Control) |
| Dimensions | 810 × 500 × 370 mm |
| Weight | 68 kg |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Sample Container | High-Purity Tin or Silver Cups |
| Optional Accessories | Analytical Balance Integration, Consumables Kits (Tubes, Cups, Reagents), Isotope Ratio Interface (IRMS-ready) |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Element5 824 |
| Detection Elements | C, N |
| Sample Form | Solid (soil), liquid |
| Combustion System | Dual-furnace Dumas flash combustion |
| Separation Method | GC column (3 m) |
| Detection | High-sensitivity TCD (reference-gas-free self-calibration) |
| Autosampler Options | Pneumatic (147-position), electric (32/50/100-position), manual |
| Analysis Time (C/N) | ≤5 min |
| Measurement Range | C/N: 0.002–20 mg |
| Accuracy | <0.2% (certified reference materials, purity >99.9%) |
| Precision | <0.1% RSD (certified reference materials, purity >99.9%) |
| Furnace Temp | Up to 1100 °C (left & right), separation oven up to 110 °C |
| Carrier Gas | Ultra-high-purity He (99.999%, 3–5 bar) |
| Oxidant | Ultra-high-purity O₂ (99.999%, 3–5 bar) |
| Auxiliary Gas | Oil-free compressed air |
| Power Supply | 230 V, 50/60 Hz, 5 A, 1100 W |
| Dimensions | 810 × 500 × 370 mm |
| Weight | 68 kg |
| Software | EAS Clarity (linear, quadratic, cubic calibration |
| Compliance | Designed for GLP/GMP environments |