Chemical Analysis Instruments
Filter
Showing 7111–7140 of 10722 results
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PARSTAT 4000A |
| Channel Count | Single-Channel |
| Current Range | ±4 A (expandable to ±20 A) |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±4 A |
| Maximum Cell Voltage | ±48 V |
| Minimum Current Range | 40 pA (optional low-current module: 80 fA) |
| Current Resolution | 1.2 fA (optional: 2.5 aA) |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Sampling Rate | 1 µs |
| Onboard Memory | 4 MB |
| Input Impedance | >10¹³ Ω |
| Grounding Mode | Floating (isolated ground) |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PMC2000 / PMC1000 / PMC500 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 4 nA – 2 A |
| Current Accuracy | ±0.2% of reading, ±0.2% of range (down to 4 nA) |
| Potential Accuracy | ±0.2% of reading, ±2 mV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Data Acquisition Rate | up to 500 kS/s (per channel), 1 MS/s (burst mode) |
| Auxiliary Voltage Measurement | 6-wire remote sensing |
| Channel Capacity | Up to 8 independent, hot-swappable channels per mainframe |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PMC2000 / PMC1000 / PMC200 |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Number of Channels | Up to 8 independent, hot-swappable channels per mainframe |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 MHz to 10 µHz |
| Data Acquisition Rate | up to 500 kS/s (per channel) |
| Auxiliary Voltage Input | 6-wire Kelvin sensing |
| Resolution (PMC1000) | 120 fA |
| Impedance Scan Range | 10 µHz – 7 MHz (with PMC2000 module) |
| Floating Ground Architecture | Standard |
| Brand | Princeton Applied Research |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PMC-1000 AT |
| Instrument Type | Electrochemical Workstation |
| Channel Architecture | Modular Multi-Channel (Up to 3 Slots) |
| Current Range | ±2 A to ±2 nA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (expandable to ±20 A internal / ±30 A external) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Voltage Resolution | 150 nV (24-bit ADC) |
| Current Resolution | 30 fA (24-bit ADC) |
| Low-Current Extension (LCI) | 122 aA |
| Analog Inputs | 2 (including thermistor interface) |
| Analog Outputs | 2 |
| Digital I/O | 1 input, 4 outputs |
| Communication | Ethernet-based modular chassis architecture |
| Electrode Connections | CE, WE, RE, SE + dual auxiliary voltage dividers (8-wire configuration) |
| Supported Techniques | CV, LSV, SSLV, CA, CP, CC, CR, LPR, Tafel, PEIS, GEIS, SWV, DPV, FP, Arbitrary Waveform, iR Compensation, Ohmic Drop Correction, Looping & Variable Parameter Sequencing |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | QCM922A |
| Frequency Range | 5–30 MHz |
| Frequency Resolution | 0.01 Hz |
| Resistance Range | 1 Ω – 10 kΩ |
| Resistance Resolution | 0.01 Ω |
| Conductance Frequency Characterization Range | 4–30 MHz |
| Δf Analog Output | ±10 V (14-bit), selectable ranges from ±100 Hz to ±500 kHz |
| ΔR Analog Output | ±10 V (14-bit), selectable ranges from ±10 Ω to ±10 kΩ |
| Analog Inputs | 2 channels, ±3/6/12 V (14-bit) |
| Minimum Control Interval | 10 ms |
| Display | 20-character 4-line OLED |
| Interface | USB 2.0 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 162 × 160 × 95 mm |
| Weight | 1.3 kg |
| Operating Temperature | 5–40 °C, non-condensing |
| Certification | CE |
| Compatible Crystals | 9 MHz AT-cut quartz sensors (QA-A9M and QA-A30M series) with electrode materials including Au, Pt, Ag, Al, C, Cu, ITO, Mo, Ni, Si, SiO₂, SUS304, Ti |
| standard electrode diameter | 5 mm |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QCM922A |
| Pricing | Available Upon Request |
| Frequency Range | 5–30 MHz |
| Frequency Resolution | 0.01 Hz |
| Resistance Range | 1 Ω – 10 kΩ |
| Resistance Resolution | 0.01 Ω |
| Conductance Frequency Characterization Range | 4–30 MHz |
| Δf Analog Output | ±10 V (14-bit), selectable ranges ±100 Hz to ±500 kHz |
| ΔR Analog Output | ±10 V (14-bit), selectable ranges ±10 Ω to ±10 kΩ |
| Analog Inputs | 2 channels, ±3/6/12 V (14-bit) |
| Minimum Time Resolution | 10 ms |
| Display | 20-character 4-line OLED |
| Interface | USB 2.0 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 162 × 160 × 95 mm |
| Weight | 1.3 kg |
| Operating Temperature | 5–40 °C, non-condensing |
| Certification | CE |
| Compatible Crystals | 9 MHz AT-cut, 5 mm diameter, electrode materials include Au, Pt, Ag, Al, C, Cu, ITO, Mo, Ni, Si, SiO₂, SUS304, Ti |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaSCAN |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Princeton Applied Research |
|---|---|
| Origin | United Kingdom |
| Distributor Type | General Distributor |
| Import Status | Imported |
| Model | VersaScan |
| Instrument Type | Electrochemical Workstation |
| Current Range | 4 nA – 2 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading ± 2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | VersaSTAT 3A / VersaSTAT 4A |
| Instrument Type | Potentiostat/Galvanostat |
| Channel Configuration | Single-Channel |
| Current Range | 4 nA – 2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Electrode Configurations | 2-, 3-, and 4-electrode with ground connection |
| Data Acquisition | Triple 16-bit ADC (500 kS/s) |
| Time Resolution | 10 µs |
| Potentiostat Bandwidth | 1 MHz |
| Slew Rate | ≥8 V/µs |
| Rise Time (−1.0 V to +1.0 V) | <350 ns |
| Input Impedance | 10¹² Ω |
| Leakage Current | 5 pA |
| CMRR | 60 dB @ 100 kHz |
| IR Compensation | Positive Feedback & Dynamic Compensation |
| Interface | USB 2.0 (Plug-and-Play) |
| Software | VersaStudio Suite (VersaSTAT 300 / 400 editions) |
| Compliance | CE-marked, Designed for GLP/GMP-aligned workflows, Compatible with ASTM G5, G102, G106, ISO 17475, and USP <797> electrochemical validation frameworks |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Sensor Type | Back-illuminated, fully depleted silicon CCD |
| Pixel Format | 1340 × 100 (HR/LD) or 1340 × 400 (HR/LD) |
| Pixel Size | 20 × 20 µm |
| QE | 75% @ 1000 nm (HR), optimized dark current < 0.0005 e⁻/pix/s (LD) |
| Readout Speed | Up to 32 MHz dual-ADC (HR), 16 MHz (LD) |
| Spectral Acquisition Rate | Up to 1650 spectra/s (continuous), 215 kHz (kinetics mode, HR only) |
| Cooling | ArcTec™ multi-stage thermoelectric cooling |
| Interface | USB 3.0 (5 Gb/s), optional fiber-optic USB extender (50 m) |
| Software | LightField 64-bit with PICAM SDK, IntelliCal wavelength & intensity calibration, LabVIEW/MATLAB/EPICS compatibility |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | FER-SCI-BRX, FER-SCI-BX |
| Focal Length | 80.8 mm |
| Aperture | f/4 |
| Spectral Resolution (full focal plane) | 0.20–0.24 nm |
| Wavelength Range | UV-NIR (200–1100 nm) and VIS-NIR (400–1100 nm) |
| Grating Options | 295, 600, 1200 g/mm (interchangeable single-grating turret) |
| Slit Widths | 10–500 µm (laser-cut, height 3.3 mm) |
| CCD Type | Back-illuminated, deep-depletion, frame-transfer architecture with eXcelon and UV coating |
| Sensor Format | 1024 × 256 active + 1024 × 256 storage (total 1024 × 512) |
| Peak Quantum Efficiency | 95% |
| Cooling | Thermoelectric to −60 °C |
| Read Noise | 10 e⁻ rms @ 1 MHz |
| Integration Time | Up to 40 minutes (FER-SCI-BRX), several hours (FER-SCI-BX) |
| Spectral Acquisition Rate | 292 fps (FVB mode, FER-SCI-BRX), 124 fps (FVB mode, FER-SCI-BX) |
| Kinetic Mode Speed | >10,000 spectra/s (10-row binning, FER-SCI-BRX), >5,000 spectra/s (10-row binning, FER-SCI-BX) |
| Wavelength Accuracy | 0.26 nm |
| Repeatability | 0.13 nm |
| Spatial Resolution | 38.5 lp/mm @ 50% contrast (Nyquist-limited, full focal plane) |
| Line Transfer Speed | Adjustable 5.6–35 µs/line (FER-SCI-BRX), 15.2–95 µs/line (FER-SCI-BX) |
| Nonlinearity | <1% @ 1 MHz |
| Gain Options | 1.5 or 3 e⁻/ADU |
| Interface | USB 3.0 (3 m cable included) |
| I/O | Three MCX coaxial ports (2 trigger outputs, 1 trigger input), onboard programmable timing generator |
| Software | 64-bit LightField with real-time processing engine, IntelliCal lamp integration for automated wavelength and intensity calibration |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane81-BRX/BX-VR, IsoPlane81-BRX-UR |
| Spectral Range | 200–1100 nm |
| Focal Length | 80.0 mm |
| f-number | f/4 |
| Spectral Resolution (FWHM) | 0.1 nm |
| Slit Width | 10–500 µm |
| Sensor Format | 1024 × 256 |
| Cooling | Thermoelectric to –45 °C |
| Peak Quantum Efficiency | >95% (up to >97% with eXcelon™) |
| Interface | USB 3.0 |
| Grating Options | 150–4320 g/mm |
| Optical Coating | Protected silver |
| Brand | Princeton Instruments |
|---|---|
| Sensor Type | Back-illuminated or front-illuminated deep-depletion CCD |
| Energy Range | 3–20 keV |
| Window Material | Vacuum-integrated beryllium (Be) |
| Cooling | Thermoelectric (TE) cooling to –70 °C |
| Readout Architecture | Dual-amplifier selectable for low-noise or high-dynamic-range mode |
| Software Support | LightField v8.x, PICAM SDK, LabVIEW® and MATLAB® integration |
| Compliance | ASTM E1316, ISO/IEC 17025-compatible operation, FDA 21 CFR Part 11-ready audit trail (via LightField) |
| Brand | Princeton Instruments |
|---|---|
| Origin | USA |
| Model | QCM 922 |
| Frequency Range | 1–10 MHz |
| Frequency Resolution | 0.1 Hz |
| Resonance Resistance Range | 10–16 kΩ (0.1 Ω resolution) |
| Electrode Area | 0.2 cm² |
| Electrode Material | Sputtered Au or Pt (300 nm thickness) |
| Crystal Fundamental Frequency | 9 MHz |
| Operating Temperature | 0–40 °C |
| Power Supply | 100–120 VAC / 230–240 VAC, 50–60 Hz, 15 W |
| Interface | IEEE-488 (GPIB), RS-232 |
| Analog Output | ±10 V (12-bit), selectable impedance scaling (1/2/4/8/16 kΩ) |
| Display | 40-character × 2-line LCD |
| Dimensions | 26 × 88 × 230 mm |
| Weight | 3.3 kg |
| Software Compatibility | Windows 95/98, ≥100 MHz CPU, 32 MB RAM, 10 MB HDD, GPIB interface card required |
| Brand | Princeton Instruments |
|---|---|
| Origin | USA |
| Model | QCM 922 |
| Frequency Range | 1–10 MHz |
| Frequency Resolution | 0.1 Hz |
| Resonance Resistance Range | 10–16 kΩ (0.1 Ω resolution) |
| Electrode Area | 0.2 cm² |
| Electrode Material | Sputtered Au or Pt (300 nm thickness) |
| Crystal Fundamental Frequency | 9 MHz |
| Operating Temperature | 0–40 °C |
| Power Supply | 100–120 VAC / 230–240 VAC, 50–60 Hz, 15 W |
| Interface | IEEE-488 (GPIB), RS-232 |
| Analog Outputs | ±10 V (12-bit), selectable impedance scaling (1/2/4/8/16 kΩ) |
| Display | 40-character × 2-line LCD |
| Dimensions | 26 × 88 × 230 mm |
| Weight | 3.3 kg |
| Software Compatibility | Windows 95/98, ≥100 MHz CPU, 32 MB RAM, 10 MB HDD, GPIB interface card required |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Models | SP2150, SP2300, SP2500, SP2750 |
| Pricing | Upon Request |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model Variants | TR555, TR557, TR777, DM55, DM77 |
| Spectral Range | 200 nm – 2.2 µm |
| Resolution (Additive Mode) | up to 0.13 cm⁻¹ (TR777) |
| Resolution (Subtractive Mode) | up to 0.4 cm⁻¹ |
| Stray Light Rejection | <1×10⁻⁶ (enabling Raman measurements within 5 cm⁻¹ of Rayleigh line) |
| Focal Length Options | 500 mm, 750 mm, 1000 mm, 1500 mm, 1750 mm, 2250 mm |
| Aperture Ratio | f/6.5 – f/9.7 |
| Grating Compatibility | Up to 1800 grooves/mm |
| Operating Modes | Additive (high-resolution), Subtractive (ultra-low stray light), Independent Dual/Triple Stage |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | PRO-MS 3600 |
| Detection Range | ppb to 100% (v/v) |
| Detection Principle | Quadrupole Mass Spectrometry |
| Response Time | < 1.5 s (typical for single-point analysis) |
| Ion Source | High-efficiency inertized electron ionization source |
| Quadrupole Material | Passivated stainless steel |
| Inlet System | Multi-stage differential pumping with low-dead-volume valving |
| Software | Real-time spectral acquisition and quantitative analysis suite compliant with GLP data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Process Guardian™ |
| Instrument Type | In-line Raman Spectrometer |
| Laser Wavelength | 785 nm |
| Enclosure | 19-inch rack-mount industrial chassis |
| Control Architecture | Embedded real-time system with integrated display and HMI |
| Fiber Interface | FC/PC dual-fiber connector |
| Channel Expansion | Up to 8 channels via multiplexer integration |
| Safety Features | Laser fiber break detection, emergency stop interface |
| Optical Technology | HTVS™ (High-Throughput Virtual Slit) spectrograph |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant data handling, ATEX/IECEx-certified options available for hazardous areas |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | AtmosFIRair |
| Instrument Type | Portable FTIR Spectrometer |
| Wavenumber Range | 485–8500 cm⁻¹ |
| Resolution Options | 1, 2, 4, or 8 cm⁻¹ |
| Scan Speed | Up to 1 spectrum per second (resolution-dependent) |
| Signal-to-Noise Ratio | >20,000:1 (peak-to-peak, 1-min acquisition), >120,000:1 (RMS, 1-min acquisition) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Model | ProMass |
| Form Factor | Semi-portable (carrying case or 6U 19″ rack-mount) |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | Adjustable (typical range 1–100 u or 1–300 u, configurable per application) |
| Detection Limit | Sub-ppb to low-ppb level (dependent on gas species and integration time) |
| Response Time | < 100 ms for single-ion monitoring |
| Ion Source | Electron Impact (EI), 70 eV standard |
| Detector | Dual-mode — Faraday Cup + Secondary Electron Multiplier (SEM) |
| Vacuum System | Integrated turbomolecular pump with backing pump |
| Compliance | CE-marked, RoHS-compliant, designed for industrial environments per IEC 61000-6-2/6-4 |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ProMass-D |
| Pricing | Available Upon Request |
| Mass Range Options | 0–100 amu, 0–200 amu, or 0–300 amu (configurable) |
| Detection Principle | Quadrupole Mass Filtering (QMS) |
| Ion Detection | Dual-mode—Faraday Cup + Secondary Electron Multiplier (SEM) |
| Sample Inlet | Direct Capillary Inlet |
| Response Time | Millisecond-scale |
| Application Domain | Real-time Gas Phase Analysis in Lab and Process Environments |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ProMass-T |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PEMFC-100 |
| Pricing | Available Upon Request |
| Brand | PSC |
|---|---|
| Origin | USA |
| Model | mIRage |
| Instrument Type | Laboratory Benchtop System |
| Spectral Range | IR (3600–800 cm⁻¹), Raman (3900–200 cm⁻¹) |
| Spatial Resolution | ~500 nm |
| Measurement Mode | Non-contact, Reflection-Based Optical Photothermal Infrared (O-PTIR) |
| Compliance | Fully Compatible with ASTM E1252, ISO 18387, USP <1119>, FDA 21 CFR Part 11 (via optional audit-trail software module) |
| Software Platform | mIRage Pro v4.2 with GLP/GMP-ready data integrity controls |
| Brand | PSC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | mIRage-LS |
| Instrument Category | Laser-Based Infrared Spectrometer |
| Instrument Type | Laboratory Benchtop System |
| Wavenumber Range | 3600–800 cm⁻¹ |
| Spatial Resolution | ~500 nm |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nimbus |
| Instrument Type | Electrospray Ionization (ESI) Source |
| Compatibility | Thermo and SCIEX LC-MS Systems |
| Operating Mode | Standalone (No External PC or Software Required) |
| Key Technology | Integrated eFrit Nanospray Emitters, Dual-Column Switching, On-Chip Column Heating & Temperature Control, Active Spray Tip Purging with Sheath Nitrogen Gas |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PT-P5 |
| Instrument Type | Portable |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Model | PT3000 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-Made) |
| Pricing | Available Upon Request |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Producer |
| Origin Classification | Domestic |
| Model Range | 50–60 mL |
| Pricing | Upon Request |