| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Conventional Gas Chromatograph with Electronic Flow and Pressure Control (EFC/EPC) |
| Ion Source | Dual-Filament Electron Ionization (EI) Source |
| Mass Analyzer | 180 mm Rod-Length Quadrupole with Pre-Filter RF Compensation |
| Mass Range | 1.5–1000 amu |
| Resolution | Unit Mass Resolution (UMR) |
| Sensitivity | ≥30:1 S/N for 1 pg Octafluoronaphthalene (OFN) in Full Scan Mode |
| Scan Speed | 10,000 amu/s |
| Library | NIST2014 Mass Spectral Library (Standard) |
| Compliance | Designed to Support GLP/GMP Data Integrity Requirements (Audit Trail, User Authentication, Electronic Signatures Optional via Software Configuration) |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | UPY-6800 |
| Quotation | Upon Request |
| Mass Analyzer Type | Single Quadrupole |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Sample Introduction | Integrated Pyrolyzer Module (Thermal Desorption/Pyrolysis Interface) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC1290/MS8100 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | 1.5–1100 u |
| Resolution | >1200 (FWHM) |
| Sensitivity | 600:1 (S/N for 1 pg octafluoronaphthalene) |
| Scan Speed | Up to 24,000 u/sec |
| Oven Ramp Rate | 0–80 °C/min |
| Pressure Control Accuracy | 0–100 psi |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1–1000 amu |
| Mass Resolution (FWHM) | ≥1200 (at m/z 502) |
| Sensitivity | ≥200:1 (Signal-to-Noise Ratio, S/N, for 1 pg OFN in Full Scan Mode) |
| Scan Speed | ≥10,000 u/s |
| Oven Ramp Rate | ≥80 °C/min |
| Pressure Control Accuracy | ±0.01 psi (EPC-controlled) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DFS High-Resolution GC/MS |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| GC Configuration | Dual-Column, Dual-Trace 1310 GC Integration |
| Automation | TriPlus RSH Autosampler |
| Ion Source | Removable, Vacuum-Lock Ion Box |
| Analyzer Architecture | Double-Focusing Magnetic Sector with Ring-shaped Electrostatic Analyzer (ESA) |
| Calibration | Field-Based Mass Calibration Independent of Scan Speed, Ion Polarity, and Ionization Mode |
| Detection | Dual-Stage Electron Multiplier with Pneumatic Valve Vacuum Lock |
| Regulatory Compliance | Designed for EPA Method 1613/8270, EU Directive 2006/122/EC, WHO IPCS Dioxin Guidelines, USP <1225>, FDA 21 CFR Part 11 Audit Trail Support |
| Brand | Thermo Fisher |
|---|---|
| Model | DFS |
| Type | Double-Focusing Magnetic Sector GC-MS |
| Detector | Dual-Channel Electron Multiplier with Convertor Electrode |
| Resolution | Up to 100,000 (10% Valley) |
| Mass Range | 10–2000 m/z |
| Ion Source | Removable, Modular EI/CI Source |
| Vacuum System | Pneumatic Valve Lock for Ion Box Exchange Without Venting |
| GC Compatibility | Dual Trace 1310 GCs on Single Ion Source |
| Automation | TriPlus RSH Autosampler with Dual-Column Sequential Injection |
| Calibration | Field-Based, Mode-Independent Mass Calibration |
| Software | Thermo Xcalibur with DFS-Specific Acquisition & Quantitation Modules |
| Compliance | Designed for EPA Method 1613/8270, EU 2017/625, ISO 18073, and GLP/GMP environments requiring 21 CFR Part 11 audit trails |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Exactive™ GC Orbitrap™ GC-MS |
| Instrument Type | Orbitrap Mass Spectrometer |
| Chromatography Type | Gas Chromatography |
| Mass Range | Not Specified |
| Resolution | 60,000 (FWHM) at m/z 200 |
| Sensitivity | <6 fg OFN (Octafluoronaphthalene) |
| Scan Speed | Not Specified |
| Ionization Modes | Electron Ionization (EI) / Chemical Ionization (CI) |
| Ion Source | Thermo Scientific™ ExtractaBrite™ with Vacuum Lock |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography |
| Mass Range | 1.2–1100 amu |
| Resolution | Unit Mass Resolution across Full Mass Range (EI Full Scan) |
| Instrument Detection Limit (IDL) | ≤2 fg (octafluoronaphthalene, 1 pg/µL) |
| Sensitivity | Unit mass resolution maintained across entire mass range |
| Scan Speed | 20,000 u/s |
| Sample Introduction | Online Cryogenic Thermal Desorption with Dual-Trap Architecture |
| Detection Limits | ≤0.02 ppb (propylene, C₂–C₅), ≤0.01 ppb (benzene, C₆–C₁₂ |
| Analysis Cycle Time | ≤60 min |
| GC Oven Temperature Range | 3 °C above ambient to 450 °C (0.1 °C control precision) |
| Pressure Control | Electronic Pneumatic Control (EPC), 0–1000 kPa, ±0.001 psi accuracy |
| Carrier Gas | Ultra-high-purity helium (99.9995%) |
| Data System | Embedded industrial PC (Intel CPU, 32 GB RAM), fully automated 7×24 operation with self-calibration, aging, and diagnostic routines |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TSQ 8000 Evo |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Detection Principle | Electron Ionization (EI) / Chemical Ionization (CI) with Tandem Mass Spectrometry (MS/MS) in SRM/MRM mode |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | TSQ 8000 |
| Instrument Category | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Gas Chromatography (GC) Coupled System |
| Collision Gas Options | Nitrogen or Argon (Helium-Free Operation) |
| Ion Source | Dual-Heated, Removable Without Venting |
| Detector | DynaMax™ High-Dynamic-Range Electron Multiplier |
| Software Platform | Thermo Scientific TraceFinder™ and AutoSRM™ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TSQ Quantum XLS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography (GC) |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI), Positive/Negative Pulse CI (PPINICI) |
| Collision Cell Geometry | 90° bent collision cell with zero crosstalk design |
| Key Technology | DuraBrite IRIS ion source, High-Selectivity SRM (H-SRM), Structural Selectivity Detection (SSD), Quantitation-Triggered Enhanced MS/MS (QED) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | ISQ 7000 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Coupling |
| Scan Speed | ≤ 20,000 u/s |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific ISQ™ 7610 Single Quadrupole GC-MS |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ISQ LT |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography-Mass Spectrometry System |
| Mass Range | 1.2–1100 u |
| Ion Source | ExtractaBrite™ |
| Detection Mode | Full Scan and SIM Simultaneously |
| Data Acquisition Rate | Up to 10,000 Da/sec |
| Vacuum System | Extended Turbo Molecular Pump |
| Optional Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI) |
| Compatible Inlets | Split/Splitless, PTV, Large Volume Injection (LVI), Backflush, Thermal Desorption, Purge & Trap, SPME |
| Software Platforms | Xcalibur™, TraceFinder™, Chromeleon™ Simply Intelligent™ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ISQ QD |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Orbitrap Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | m/z 30–3000 |
| Resolution | Up to 240,000 at m/z 200 |
| Scan Speed | Up to 40 Hz at resolution setting 7,500 (m/z 200) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Orbitrap Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | m/z 30–3000 |
| Resolution | Up to 240,000 at m/z 200 |
| Scan Speed | Up to 40 Hz at R = 7,500 (m/z 200) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Orbitrap Mass Spectrometer |
| GC-MS Configuration | Conventional Gas Chromatography–Mass Spectrometry System |
| Mass Range | m/z 30–3000 |
| Resolution | Up to 30,000 FWHM at m/z 200 |
| Scan Speed | Up to 40 Hz at Resolution Setting of 7,500 (FWHM) at m/z 200 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Q Exactive™ GC Orbitrap |
| Instrument Category | Orbitrap-based GC-MS/MS System |
| Chromatography Type | Conventional Gas Chromatography Coupled Mass Spectrometry |
| Mass Range | Not Specified |
| Resolution | Up to 100,000 (FWHM) at m/z 272 |
| Mass Accuracy | < 1 ppm (typical, internal calibration) |
| Sensitivity | < 6 fg OFN (octafluoronaphthalene) LOD under EI mode |
| Scan Speed | Not Specified |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Origin | Imported |
| Model | TSQ 9000 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Gas Chromatography-Coupled |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | TSQ 9610 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Conventional Gas Chromatography Coupled to Tandem Mass Spectrometry |
| Detector | XLXR Extended Linear Dynamic Range Electron Multiplier |
| Linear Dynamic Range Enhancement | 2× vs. prior-generation detectors |
| Detector Lifetime Improvement | Up to 8× |
| Ion Source Technology | NeverVent™ AEI and ExtractaBrite™ Sources |
| Software Suite | Thermo Scientific Chromeleon CDS with SmartTune, Method Optimization Wizard, Instrument Health Monitoring, Pre-validated Method Packages |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TSQ Duo Triple Quadrupole GC-MS/MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Conventional Gas Chromatography-Mass Spectrometry (GC-MS) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSQ Quantum GC |
| Price Range | USD 135,000 – 205,000 (FOB) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Standalone GC-Coupled System |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI), switchable without venting |
| Collision Cell | Zero-Crosstalk RF-Only Quadrupole Collision Cell |
| Acquisition Modes | High-Selectivity SRM (H-SRM), Quantitative Enhanced Data-dependent MS/MS (QED-MS/MS) |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11 audit trail, electronic signature, and data integrity requirements |
| Optional Inlets | PPINICI Pulsed Positive/Negative Ion Chemical Ionization Source, DEP/DIP Solid Probe Inlet |
| Flow Control | Digital Mass Flow Controller (MFC) for carrier and reagent gases |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | Thermo Scientific TSQ™ 9610 Triple Quadrupole GC-MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Ion Source Options | Advanced Electron Ionization (AEI), ExtractaBrite EI/CI Source with Vacuum Pressure Interface (VPI) or without VPI |
| Turbo Pump Configurations | High-throughput or Medium-throughput Turbomolecular Pump |
| Software Platform | Chromeleon CDS with SmartStatus™ Instrument Monitoring |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GC-IMS 1000 |
| Form Factor | 19-inch rack-mountable (4U height) |
| Ionization Source | Non-radioactive, low-power UV photoionization lamp (10.6 eV) |
| Polarity Mode | Dual-polarity (positive and negative ion detection) |
| Detection Limit | Sub-ppt (v/v) for selected volatile organic compounds |
| Sample Introduction | Negative-pressure direct draw sampling |
| Flow Path Materials | Fully inert (SilcoNert®-treated stainless steel, PFA, and fused silica) |
| Control Interface | Integrated industrial PC with native Chinese-language software suite |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GC-MS 8700 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GC-MS 8700 |
| Mass Analyzer Type | Single Quadrupole |
| Mass Range | Up to 1250 amu |
| Ion Source | High-Temperature Inert Ceramic |
| Vacuum System | Dual-Chamber Design with 250 L/s Turbo Molecular Pump |
| Ionization Modes | Electron Ionization (EI) |
| Scan Modes | Full Scan (SCAN) and Selected Ion Monitoring (SIM) Simultaneously |
| Filament | Dual Long-Life Inert Filament |
| Pre-Quadrupole | Removable |
| Detector | Electron Multiplier with Active Protection Logic |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ASTM D5847, ISO 17025–compliant data handling, and supports 21 CFR Part 11–ready audit trail configuration (via optional software module) |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | CP3800–2200 |
| Instrument Type | Ion Trap Mass Spectrometer |
| GC Configuration | Conventional Capillary GC |
| Mass Range | 1–1000 u |
| Resolution | 1000–2000 (FWHM at m/z 502) |
| Sensitivity | >300:1 (S/N, 1 pg octafluoronaphthalene, full scan, RMS) |
| Scan Speed | 15,000 u/s |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI), software-switchable without source exchange |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Atmospheric Pressure Gas Chromatography (APGC) Ion Source |
| Instrument Type | Atmospheric Pressure Chemical Ionization (APCI)-style GC-compatible ion source for triple quadrupole, Q-TOF, and ion mobility–enabled mass spectrometers |
| Compatibility | Xevo TQ-S, Xevo G2-S QTof, SYNAPT G2-Si |
| Vacuum Requirement | None (operates at atmospheric pressure) |
| Switching Time | <2 minutes between UPLC and GC modes |
| Design Principle | Engineered Simplicity™ |
| Regulatory Alignment | Supports 21 CFR Part 11-compliant workflows via MassLynx™ and UNIFI™ software |