Hardness Tester
Filter
Showing 31–60 of 196 results
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | FV-810 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0–3000 HV |
| Total Test Force | 50 kgf |
| Maximum Specimen Height | 210 mm |
| Specimen Depth Capacity | 165 mm |
| Loading Mechanism | Fully Automatic (Load-Hold-Unload) |
| Turret Operation | Motorized Automatic |
| Standard Indenter | Single Diamond Vickers (HV) |
| Optional Dual Indenter Mount | Simultaneous HV + Knoop (HK) |
| Max. Objective Lenses | 4 (including standard pair) |
| Display | Full-color LCD Touchscreen with On-screen Data Overlay |
| Compliance | JIS R 1607 (Fracture Toughness Kc Calculation), ISO 6507, ASTM E384, ASTM E92 (Brinell Conversion) |
| Power Supply | AC 100–240 V, 50/60 Hz (Auto-ranging) |
| Brand | Future-Tech |
|---|---|
| Origin | Japan |
| Model | LC-200R / LC-200RB |
| Rockwell Scale Range | 20–70 HR |
| Total Test Force | 187.5 kgf (1839 N) |
| Maximum Specimen Height | 255 mm |
| Force Application Method | Load Cell-Based Closed-Loop Electro-Mechanical Actuation |
| Display | 8-inch Full-Color LCD Touchscreen |
| Compliance | ISO 6508-2, ASTM E18, JIS Z 2245, ISO 6506-2 (for Brinell mode on LC-200RB), ASTM D785, JIS K 7202 |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SLQY-96B |
| Instrument Type | Rockwell Hardness Tester |
| Ball Indentation Load | 9.8 N |
| Total Test Forces | 49 N, 132 N, 358 N, 612 N, 961 N |
| Indentation Depth Resolution | 0.001 mm |
| Display Interface | 10-inch capacitive touch screen |
| Data Output | Integrated thermal micro-printer |
| Test Modes | Ball indentation, Rockwell hardness, compression resistance testing |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SLQY-96B2 |
| Instrument Type | Rockwell Hardness Tester |
| Ball Indentation Load | 9.8 N |
| Total Test Forces | 49 N, 132 N, 358 N, 612 N, 961 N |
| Indentation Depth Resolution | 0.001 mm |
| Display Interface | 10-inch capacitive touch screen |
| Data Output | Integrated thermal micro-printer |
| Test Modes | Ball indentation hardness, Rockwell hardness, compression resistance test |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SLQY-96B3 |
| Instrument Type | Rockwell Hardness Tester |
| Ball Indentation Load | 9.8 N |
| Total Test Forces | 49 N, 132 N, 358 N, 612 N, 961 N |
| Indentation Depth Resolution | 0.001 mm |
| Display Interface | 10-inch capacitive touch screen |
| Data Output | Integrated thermal micro-printer |
| Test Modes | Ball indentation, Rockwell hardness, compression resistance test |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SLQY-96B4 |
| Instrument Type | Ball Indentation Hardness Tester (compliant with ISO 2039-1 and ASTM D785 for comparative Rockwell-scale measurements) |
| Test Force Range | 9.8 N (ball indentation preload), 49 N / 132 N / 358 N / 612 N / 961 N (main indentation forces) |
| Indentation Depth Resolution | 0.001 mm |
| Display Interface | 10-inch capacitive touchscreen HMI |
| Data Output | Integrated thermal micro-printer |
| Test Modes | Ball Indentation (ISO 2039-1), Rockwell-type hardness (ASTM D785 reference scale), Compression Resistance Test |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SLQY-96B5 |
| Instrument Type | Rockwell Hardness Tester |
| Ball Indentation Load | 9.8 N |
| Total Test Forces | 49 N, 132 N, 358 N, 612 N, 961 N |
| Indentation Depth Resolution | 0.001 mm |
| Display Interface | 10-inch capacitive touchscreen |
| Data Output | Integrated thermal micro-printer |
| Test Modes | Ball indentation, Rockwell hardness, compression resistance testing |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SLQY-96B |
| Instrument Type | Rockwell & Ball Indentation Hardness Tester |
| Hardness Range | 20–88 HR |
| Total Test Force | 60 kgf (588.4 N) |
| Maximum Specimen Space | 260 mm × 150 mm |
| Initial Load (Ball Indentation) | 9.8 N |
| Initial Load (Rockwell) | 98.07 N |
| Main Loads (Ball Indentation) | 49 N, 132 N, 358 N, 612 N, 961 N |
| Main Loads (Rockwell) | 588.4 N, 980.7 N, 1471 N |
| Indenter Diameters | 5 mm & 10 mm steel spheres (ball indentation) |
| Specimen Height Limit | 4 mm |
| Indentation Depth Resolution | 0.001 mm |
| Timer Range | Programmable |
| Timer Accuracy | ±1% |
| Indication Accuracy | ±1% |
| Frame Deformation Under Load | ≤0.025 mm |
| Brand | Innovatest |
|---|---|
| Country of Origin | Netherlands |
| Manufacturer | Innovatest B.V. |
| Type | Rockwell Hardness Tester |
| Measurement Range | 10–100 HR |
| Total Test Force | 187.5 kgf |
| Test Space | 650 mm (H) × 175 mm (D) |
| Nose Extension Length | 170 mm |
| Test Table Dimensions | 425 mm × 370 mm (with hardened zone & T-slots) |
| Preload Forces | 3 kgf, 10 kgf |
| Main Load Range | 15–150 kgf |
| Loading System | Fully Automatic, Load Cell-Based Closed-Loop Control |
| Guidance System | Full-Height Linear Rails + Precision Ball-Screw Drive |
| Display | 6.5″ Industrial Touchscreen |
| Software | I-TOUCH™ Hardness Control Suite |
| Data Storage | Internal Memory (up to 150 readings) |
| Interface | USB |
| Illumination | Integrated LED Surface Lighting |
| Base Enclosure | Interchangeable ABS Protective Housing |
| Brand | INNOVATEST |
|---|---|
| Origin | Netherlands |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | NEXUS 3001XLM-IMP |
| Test Force Range | 30 kgf to 3000 kgf |
| Z-Axis Travel | 345 mm |
| Specimen Height Clearance | 335 mm |
| Depth Clearance | 220 mm |
| Turret | 2-position (indenter + Brinell objective with annular LED illumination) |
| Imaging System | 5 MP full-HD camera with motorized zoom and auto-focus |
| Control Interface | IMPRESSIONS™ software on 15″ industrial touchscreen |
| Measurement Method | Automated video-based indent diameter analysis per ISO 6506-1 and ASTM E10 |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Product Type | Imported Instrument |
| Model | AMH55 |
| Instrument Category | Microhardness Tester |
| Measurement Range | 0–2000 HV (typical for Vickers microhardness) |
| Total Test Force | 1–60 kgf |
| Test Space (X × Y) | 260 × 150 mm |
| Automation Level | Fully Automated / Semi-Automated / Lite Configurations Available |
| Software Platform | Cornerstone® v5.0+ |
| Brand | HOYTOM |
|---|---|
| Origin | Spain |
| Model | Link RB |
| Test Height | 170 mm |
| Compliance | EN ISO 6508, ASTM E18, EN ISO 6506, ASTM E10 |
| Optional Accessories | HOYTOM LHB Digital Brinell Impression Measurement System, USB Digital Microscope (20×/30×/40×), Integrated Data Logging Software |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC010-HBa-1 |
| Pricing | Upon Request |
| Measurement Range | 0–100 HBa (equivalent to 25–150 HBW) |
| Indenter | 26° truncated conical tip, flat end diameter 0.176 mm |
| Resolution | 0.5 HBa |
| Accuracy | ±2 HBa (42–52 HBa), ±1 HBa (84–88 HBa) |
| Repeatability | ±2 HBa (42–52 HBa), ±1 HBa (84–88 HBa) |
| Weight | 0.5 kg |
| Compliance | GB/T 3854–2005, ASTM B648–2000 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC010-LX-C |
| Quotation | Upon Request |
| Scale Range | 0–100 HW |
| Recommended Measurement Range | 10–90 HW |
| Indenter Travel | 2.5 mm |
| Indenter Tip Radius | SR 2.5 mm |
| Dimensions | 115 × 60 × 25 mm |
| Weight | ~0.5 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC010-TH110 |
| Price | Upon Request |
| Measurement Range | 170–960 HLD |
| Indication Error | ±6 HLD (at HLD = 760 ± 30) |
| Repeatability Error | <6 HLD (at HLD = 760 ± 30) |
| Operating Temperature | 0–40 °C |
| Power Supply | 4.7–6.0 V DC |
| Battery | Ni-MH rechargeable pack (approx. 4 h charging time) |
| Weight | 0.615 kg |
| Hardness Scales Supported | HL, HRB, HRC, HB, HV, HS |
| Tensile Strength Conversion | Yes |
| Impact Device Compatibility | 7 types (auto-recognized, no recalibration required) |
| Data Display | Measured value, average, date/time, impact direction, impact count, material code, hardness value |
| Calibration | Software-based soft calibration function |
| Low-voltage alarm & charging status indicator | Yes |
| Brand | Kägi |
|---|---|
| Origin | Germany |
| Model | Micro IRHD |
| Instrument Type | Microindentation Hardness Tester for Elastomers |
| Standards Compliance | DIN ISO 48, ISO 48:2018, ASTM D1415-19, BS 903-A26 |
| Sample Thickness Range | 1–5 mm (recommended), up to 90 mm (with optional fixtures) |
| Resolution | 0.1 Micro IRHD |
| Dimensions (Tester) | Ø200 mm × 470 mm |
| Dimensions (Controller) | 290 mm × 260 mm × 75 mm |
| Weight | 17.5 kg |
| Control Interface | RS232 serial communication with Windows PC |
| Automation | Motorized Z-stage, programmable dual-weight actuation, auto-positioning sample stage |
| Software Platform | Native MS Windows application with real-time data acquisition, statistical analysis, hysteresis calculation, report generation (PDF/CSV), label printing, and ASCII export |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GYZJ-934-1 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBRV-187.5 |
| Type | Combined Brinell, Rockwell & Vickers Hardness Tester |
| Drive | Motorized Load Application |
| Compliance | ASTM E10, ASTM E18, ASTM E92, ISO 6506, ISO 6508, ISO 6507 |
| Application Scope | Ferrous & Non-ferrous Metals, Heat-Treated Surfaces, Thin Hardened Sheets, Cast Iron, Carbides, Annealed & Tempered Steels |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBS-3000 |
| Hardness Scale | HBW (Brinell, tungsten carbide ball indenter) |
| Test Force Range | 187.5 kgf to 3000 kgf (standard Brinell load range per ISO 6506-1) |
| Indenter | 10 mm hardened steel or tungsten carbide ball |
| Optical Measurement System | High-magnification eyepiece with calibrated scale or digital image capture (optional) |
| Display | Large LCD screen with real-time test parameter and result visualization |
| Data Output | RS-232 or USB interface for printer or PC connectivity |
| Compliance | Designed to meet ISO 6506-1, ASTM E10, and JIS Z 2243 requirements |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEEB140 |
| Hardness Scales | HL, HB, HRB, HRC, HV, HS |
| Display | Full Chinese LCD Menu Interface |
| Printer | Built-in High-Speed Thermal Printer |
| Environmental Rating | Vibration-Resistant, Shock-Resistant, EMI-Immune |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 16859, ASTM A956 (Leeb Method) |
| Data Traceability | On-device Printout with Timestamp & Sample ID Support |
| Power Supply | Rechargeable Li-ion Battery |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Leeb810A |
| Type | Shore A Hardness Tester |
| Display | Digital LCD |
| Application Scope | Rigid Plastics, Hard Rubbers, Coatings, and Polymer-Based Industrial Materials |
| Compliance | ASTM D2240, ISO 7619-1, ISO 868 |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | MHVSX-50 |
| Loading Method | Electromechanical Closed-Loop Force Control |
| Indentation Measurement | Dual-axis Encoder-equipped Eyepiece (D1/D2) |
| Display | 7-inch High-Sensitivity Touchscreen GUI |
| Optical System | High-Resolution Metallurgical Objective Lens with 10-Step Adjustable LED Illumination |
| Data Output | USB Export to Excel (.xlsx) |
| Hardness Conversion | Vickers (HV), Brinell (HB), Rockwell (HRB/HRC) |
| Compliance | ASTM E92, ISO 6507-1, JIS Z 2244 |
| Automation | Fully Automated Turret Positioning, Motorized Indenter/Objective Switching, Auto-Focus Optional |
| Software Interface | PC Communication via Optional RS-232/USB Protocol with Audit Trail Support |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-150 |
| Type | Portable Shear-Pin Operated Brinell Hardness Tester |
| Force Application | Mechanical Screw-Driven & Hammer-Impact Dual Mode |
| Hardness Scale | HBW (Brinell Hardness Number, tungsten carbide ball indenter) |
| Indentation Measurement | Optical Readout via Integrated Eyepiece Microscope |
| Compliance | Designed per ISO 6506-1, ASTM E10, and JIS Z 2243 standards |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | PHB-750 |
| Applicable Standard | ASTM E110, GB/T 4285 |
| Test Force | 750 kgf (fixed) |
| Force Application Method | Manual lever-driven hydraulic system with pressure-relief control valve |
| Indentation Hold Equivalent | 10–15 s via 3–4 repeated pressure peaks to 750 kgf |
| Mounting Method | Permanent magnet base for ferromagnetic substrates |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | T-U2 |
| Measurement Principle | Ultrasonic Contact Impedance (UCI) |
| Portability | Handheld, Battery-Powered |
| Compliance | ASTM A1038, ISO 17643, DIN 50159-2 |
| Hardness Scales | HV, HB, HRC, HRB (converted) |
| Indentation Load | 10 N (standard), optional 3 N / 5 N / 20 N |
| Probe Frequency | 98 MHz |
| Resolution | 1 HV |
| Repeatability | ±1.5 HV (under controlled conditions) |
| Operating Temperature | 0–40 °C |
| Battery Life | ≥12 hours (Li-ion, rechargeable) |
| Data Storage | Internal memory for ≥2,000 readings |
| Interface | USB-C, Bluetooth 5.0 |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | T-U3 |
| Measurement Principle | Ultrasonic Contact Impedance (UCI) |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 17673, ASTM A1038, DIN 50159-2 |
| Hardness Scales | HV, HB, HRC, HRB (converted) |
| Indentation Load | 10 N (standard), optional 3 N / 5 N / 20 N |
| Probe Frequency | 10 MHz |
| Resolution | 1 HV |
| Repeatability | ≤ ±1.5 HV (per ISO 17673) |
| Operating Temperature | 0–40 °C |
| Battery Life | ≥ 12 hours (Li-ion, rechargeable) |
| Data Storage | Internal memory for ≥ 2,000 readings with timestamp, location tag (optional GPS), and operator ID |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | TH520 |
| Testing Direction | Vertical |
| Maximum Test Height | 400 mm |
| Applicable Standards | ASTM E18, ISO 6508, JIS Z 2245 |
| Hardness Scales | HRA, HRB, HRC, HRD, HRF, HRG, HRH, HRR, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T |
| Load Application | Automatic motorized loading with dual-scale force system (major/minor loads) |
| Indenter Types | Diamond cone (120°, 0.2 mm tip radius) and hardened steel ball (1/16", 1/8", 1/4", 1/2") |
| Measurement Repeatability | ≤ ±0.5 HR under standardized conditions |
| Compliance | GLP-ready architecture with audit-trail-capable software interface |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | U918 |
| Compliance | DIN 50159-1:2008, ASTM A1038-2005, JB/T 9377-2010, JJG 654-2013, GB/T 34205-2017 |
| Calibration Modes | 10-point factory calibration, single-point elastic modulus compensation, multi-point direct hardness calibration (HRC, HRB, HRA, HB, HV5) |
| Display | 3.5″ color LCD with real-time statistics (min/max/avg/count/timestamp) |
| Indentation Size | <20 µm diameter (requires >200× optical magnification for visualization) |
| Measurement Time | ≤2 s per test |
| Battery | 3.6 V / 3000 mAh Li-ion, up to 15 h operation |
| Data Storage | 50 test sets + 10 calibration profiles |
| Connectivity | Bluetooth printer support (optional), USB-C PC data export |
| Test Orientation | Omnidirectional (±5° tolerance from perpendicular) |
| Hardness Scales | HV, HRC, HRA, HRB, HB (directly calibrated, no conversion tables required) |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q10 CHD MASTER/Plus |
| Instrument Type | Microhardness Tester |
| Control System | Electromechanical closed-loop sensor actuation |
| Turret | 6-position motorized turret |
| Operating Concept | 3D intuitive human-machine interface |
| Test Automation | Fully programmable sequence-based testing with adaptive dwell-time termination |
| Data Output | Configurable report templates with embedded hardness conversion algorithms |
| Image Quality | High-resolution optical imaging system with LED illumination and digital autofocus capability |
| Testing Space | Large X-Y-Z travel range (X: 200 mm, Y: 200 mm, Z: 150 mm) |
| Connectivity | Ethernet, USB 3.0, RS-232, optional integration with LIMS and MES systems |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 A/A+ |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 187 mm / 180 mm (extendable to 377 mm) |
| Maximum Specimen Weight | 50 kg |
| Motorized Cross-Table Dimensions | 170 × 250 mm |
| Height Adjustment Speed | up to 6 mm/s |
| Power Supply | 230 V~1/N/PE or 110 V~1/N/PE |
| Max. Power Consumption | ~240 W |
| Host Weight | 120 kg (137 kg with height extension) |
| Interface | 3× USB |
| Software | Qpix Control2 |
| Optional Features | Dual high-resolution camera system (up to 2×), panoramic camera (A+ only), motorized anvil/cross-table, Jominy fixture, multi-specimen holders, interchangeable indenters and objectives |