Hardness Tester
Filter
Showing 61–90 of 196 results
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 CS ECO |
| Instrument Type | Rockwell Hardness Tester |
| Force Range | 1–250 kg (9.81–2452 N) |
| Test Height | 250 mm |
| Throat Depth | 157 mm |
| Maximum Specimen Weight | 100 kg |
| Machine Weight | 77 kg |
| Display | 7-inch capacitive color touchscreen |
| Force Application | Electromechanical, fully automated |
| Power Supply | 100–240 V AC, 45–65 Hz, ~60 W |
| Compliance | ASTM E18, ISO 6508, DIN 50103, GB/T 230.2 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 R |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 260 mm / 180 mm |
| Extended Test Height (Optional) | 450 mm |
| Vertical Adjustment Speed | up to 6 mm/s |
| Anvil/Cross Table Dimensions | 250 × 260 mm |
| Data Interfaces | 3× USB, 1× Ethernet, 1× RS232 |
| Unit Weight | 95 kg (112 kg with height extension) |
| Max. Specimen Weight | 100 kg |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~240 W |
| Software | Qpix T2R |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 RCS |
| Hardness Test Method | Rockwell C Scale (HRC) |
| Maximum Test Force | 150 kgf (1471.5 N) |
| Dual Force Range Capability | 62.5 kgf (613.1 N) and 150 kgf (1471.5 N) |
| Test Height Adjustment Range | 180 mm |
| Horizontal Test Space | 180 mm |
| Anvil Diameter | Ø100 mm |
| Machine Weight | 120 kg |
| Interface | 1 × RS232-C, 1 × RJ45 (Ethernet) |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~360 W |
| Control System | Siemens S7 PLC with 4" Touchscreen HMI |
| Cycle Time | <3 s per test |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 200 CS |
| Instrument Type | Brinell-Vickers-Rockwell Combined Hardness Tester |
| Test Force Range | 0.5 – 187.5 kgf (4.9 – 1839 N) |
| Test Space | 250 mm (height) × 238 mm (throat depth) |
| Turret Positions | 5 |
| Imaging System | 5 MP industrial camera with Ethernet interface |
| Objective Lenses | XLED 2×, XLED 5×, 5×, 10×, 20×, 50×, 100× |
| Field of View | 0.113 × 0.084 mm (at 100×) to 4.24 × 3.18 mm (at XLED 2×) |
| Stage Diameter | Ø100 mm |
| Height Adjustment | Manual lead-screw drive |
| Operating System | Windows 10 IoT |
| Storage | 128 GB SSD |
| Interfaces | 1× front USB, 4× rear USB, 2× RJ45 Ethernet, 1× DisplayPort |
| Weight | 132 kg |
| Compliance | ASTM E10, E92, E18 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 / 750 / 3000 CS/C EVO |
| Test Force Range | QNESS 250 CS: 1–250 kg (9.81–2450 N) |
| QNESS 750 CS | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 CS | 0.3–3000 kg (2.94–29430 N) |
| QNESS 250 C | 1–250 kg (9.81–2450 N) |
| QNESS 750 C | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 C | 0.3–3000 kg (2.94–29430 N) |
| Test Height | C version: 395 mm |
| CS version | 175 mm |
| Throat Depth | 220 mm |
| Anvil Diameter | Ø100 mm |
| Turret Configuration | 2-position standard or 8-position optional |
| Imaging System | 5 MP industrial Ethernet camera, up to 270 FPS |
| Objective Lenses | XLED 1, XLED 2, XLED 5, 5×, 10×, 20×, 50×, 100× |
| Field of View | 0.113 × 0.084 mm (at 100×) to 7.98 × 5.97 mm (at XLED 1) |
| Display | 12″ capacitive touchscreen |
| Operating System | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max. Power Consumption | ~480 W |
| Weight | QNESS 250/750 CS: 250 kg |
| QNESS 3000 CS & all C versions | 300 kg |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 E EVO / QNESS 750 E EVO / QNESS 3000 E EVO |
| Test Force Range | QNESS 250 E EVO: 1–250 kgf (9.81–2450 N) |
| QNESS 750 E EVO | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 E | 0.3–3000 kgf (2.94–29,430 N) |
| Maximum Test Height | 510 mm |
| Throat Depth | 320 mm |
| Anvil Dimensions | 584 × 450 mm |
| Weight Capacity | ≤ 3500 kg |
| Turret Configuration | 2-position standard or 8-position optional |
| Imaging System | 5 MP industrial camera, Ethernet interface, up to 270 fps |
| Optical Magnification | XLED 1 to 100× (FOV: 0.113 × 0.084 mm at 100× up to 7.98 × 5.97 mm at XLED 1) |
| Control Interface | 12″ capacitive touchscreen |
| Operating System | Windows 10 IoT Enterprise |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max. Power Consumption | ~1230 W |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 M EVO / QNESS 750 M EVO / QNESS 3000 M EVO |
| Testing Force Range | QNESS 250 M EVO: 1–250 kgf (9.81–2450 N) |
| QNESS 750 M EVO | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 M EVO | 0.3–3000 kgf (2.94–29430 N) |
| Max Test Height | 510 mm |
| Throat Depth | 320 mm |
| Anvil Dimensions | 584 × 450 mm |
| Weight | 490 kg |
| Imaging | 5 MP industrial Ethernet camera, up to 270 fps |
| Turret | 2-position standard or 8-position optional |
| Software | Qpix T2 (optional Qpix CONTROL 2 M) |
| OS | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max Power Consumption | ~480 W |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 / 750 CA/CA+ EVO |
| Test Force Range | QNESS 250 CA EVO: 1–250 kg (9.81–2450 N) |
| QNESS 750 CA EVO | 0.3–750 kg (2.94–7358 N) |
| Test Height / Throat Depth | 250 / 220 mm |
| XY Motorized Stage Travel | X 260 mm / Y 266 mm |
| Max. Specimen Weight | 100 kg |
| Host Weight | 320 kg |
| Power Supply | 110–230 V~, 50–60 Hz, 1/N/PE |
| Max. Power Consumption | ~480 W |
| Software | Qpix Control2 |
| Camera | 5 MP Panoramic Imaging (CA+ only) |
| Supported Hardness Methods | Brinell, Vickers, Rockwell, Knoop, Polymer, Carbon Brush Testing |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 A/A+, QNESS 750 A/A+, QNESS 3000 A/A+ EVO |
| Test Force Range | QNESS 250 A/A+: 1–250 kgf (9.81–2450 N) |
| QNESS 750 A/A+ | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 A/A+ | 0.3–3000 kgf (2.94–29430 N) |
| Test Height Adjustment | Motorized asynchronous Z-axis, up to 3200 kg clamping force |
| Throat Depth / Max Vertical Clearance | 362 mm / 320 mm |
| XY Stage Travel | X 460 mm × Y 350 mm |
| Stage Size | 450 × 297 mm (motorized cross-slide) |
| Imaging System | 5 MP panoramic camera (A+ models only) |
| Software | Qpix Control2 with 3D UI, Ethernet interface (RJ45) |
| Compliance | Designed for ASTM E10, E18, E92, E384, ISO 6506, ISO 6507, ISO 6508, ISO 20422, and EN ISO 1463 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 250/750/3000 EVO |
| Instrument Type | Universal Hardness Tester |
| Load Range (Q250) | 1–250 kgf (9.8–2450 N) |
| Load Range (Q750) | 0.3–750 kgf (2.94–7358 N) |
| Load Range (Q3000) | 0.3–3000 kgf (2.94–29430 N) |
| Test Height | 175–510 mm |
| Throat Depth | 220–320 mm |
| Max Specimen Weight | ≤3500 kg |
| Imaging System | 5 MP CMOS camera with Ethernet interface |
| Display | 12″ capacitive touchscreen |
| Loading Control | Electromechanical, closed-loop force feedback |
| Illumination | XLED optical module for Brinell impression analysis |
| Turret | Manual 2-position or optional motorized 8-position auto-turret |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 60 A/A+ EVO |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.25 g – 62.5 kgf |
| Indenter | ASTM- and DAkkS-certified Vickers diamond |
| Turret | 8-position motorized |
| Illumination | White LED with electric iris shutter |
| Software | Qpix Control2 with intuitive 3D control interface |
| Positioning System | Direct-read linear encoders on X/Y/Z axes (0.5 µm resolution) |
| Optional Feature (A+ only) | Panoramic camera with automated image acquisition (49 × 37 mm field of view) |
| Microstructural Analysis Module | INSPECT (modularly licensable) |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 60 M EVO |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.00245 N – 613.1 N (0.25 g – 62.5 kg) |
| Test Space (Height/Throat Depth) | 145 mm / 170 mm |
| Stage Options | Manual Cross-Slide XY Stage (135 × 135 mm) or Standard Ø100 mm Anvil |
| X/Y Travel | 150 mm × 150 mm |
| Z-Travel | 145 mm |
| Max. Specimen Weight | 50 kg |
| Host Weight | 55 kg |
| Power Supply | 100–240 V, ~1/N/P, 45–65 Hz |
| Software | Qpix Control2 M with INSPECT metallographic analysis module |
| Test Methods Supported | Vickers, Knoop, Brinell |
| Turret | 8-position motorized, configurable with up to 3 hardness modules and 6 objective lenses |
| Illumination | White LED with motorized iris shutter |
| Imaging | High-resolution color camera integrated into optical path |
| Compliance | ASTM E384, ISO 6507, ISO 6508, EN ISO 14978, DAkkS-accredited Vickers diamond indenter included |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS CHD MASTER+ |
| Hardness Testing Methods | Vickers, Knoop, Brinell |
| Test Load Range | 0.49 – 98.1 N (50 g – 10 kgf) |
| Turret | 6-position, motorized |
| X/Y/Z Travel | 150 × 150 × 145 mm |
| Specimen Weight Capacity | ≤ 50 kg |
| Host Weight | 58 kg |
| Camera System | 5 MP color CMOS |
| Positioning Repeatability | ±3.5 µm |
| Interface | 1× USB 3.0 (hardness tester–PC), optional QDAS/PCI/AMS/REMOTE modules |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~200 W |
| Objective Lenses | 4×, 20×, 40× |
| Certified Vickers Indenters | DakkS-accredited |
| Sample Holders | CHD Master+: single-position (Ø30/40/50 mm), quad-position (Ø30/40/50 mm), octo-position (Ø30/40 mm) |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q10 / Q30 / Q60M Semi-Automatic Vickers Hardness Tester |
| Automation Level | Semi-Automatic with Motorized Turret and Auto-Focus |
| Turret Positions | 6-position motorized turret |
| Display | 12″ industrial touchscreen IPC |
| Software | Qpix Control v5.x with GLP-compliant audit trail |
| Data Export | CSV, PDF, Excel-compatible reports |
| Compliance | ASTM E384, ISO 6507-1, EN ISO 1463, USP <1054> (for hardness validation workflows) |
| Safety | User-level access control (3-tier permission system) |
| Sample Stage | Motorized X-Y-Z stage with dynamic Z-height compensation |
| Imaging | Integrated high-resolution monochrome CMOS camera, 2× optical zoom per objective, real-time edge detection and indentation recognition |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q 150 A |
| Test Methods | Rockwell (A/A+), Knoop, Brinell |
| Load Range | 1–250 kgf (9.81–2450 N) |
| Max Specimen Height/Throat Depth | 187 mm / 180 mm |
| Max Specimen Weight | 50 kg |
| Stage | Motorized X-Y Translation Stage |
| Height Adjustment | Manual Knob-Driven Dynamic Z-Axis with Collision Avoidance |
| Optional Imaging | Panoramic Camera (Q150 A+ only) |
| Illumination | High-Contrast LED Coaxial Lighting |
| Compliance | ASTM E18, ASTM E384, ASTM E10, ISO 6508, ISO 6507, ISO 6506, EN ISO 1463, DIN 50103 |
| Software | Qpix Control v5.x with Audit Trail, User Management & CFR 21 Part 11 Readiness |
| Brand | QATM |
|---|---|
| Country of Origin | Austria |
| Model | Q150 R / Q150 A / Q150 A+ |
| Hardness Scales | Rockwell (R), Brinell (B), Vickers (HV), Knoop (HK) |
| Automation Levels | Manual (R), Semi-Automatic & Fully Automatic (A), Fully Automatic with Integrated Panoramic Imaging (A+) |
| Test Force Range | 1–3000 kgf (A/A+ models) |
| Sample Height Clearance | Up to 280 mm |
| Max. Sample Weight | 50 kg |
| Interface Options | RS232, Ethernet, USB |
| Compliance | CE, ISO 6508 (Rockwell), ISO 6506 (Brinell), ISO 6507 (Vickers), ISO 4545 (Knoop), ASTM E18, E10, E384, E92 |
| Software | Qpix T2R v5.x (GLP-compliant data logging, audit trail, user access levels, report export to PDF/CSV/XLSX) |
| Brand | QATM (Qness) |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Qradial |
| Instrument Type | Universal Hardness Tester |
| Price | USD 135,000 (approx.) |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QYS-96 |
| Pricing | Available Upon Request |
| Test Principle | Ball Indentation Hardness (ISO 2039-1 / GB/T 3398.1–2008) |
| Load Range | 9.8 N (pre-load), 49 N, 132 N, 358 N, 612 N, 961 N |
| Indenter Options | Φ5 mm & Φ10 mm hardened steel ball |
| Depth Resolution | 0.001 mm |
| Max Sample Height | 30 mm |
| Indenter-to-Column Distance | 100 mm |
| Depth Measurement Accuracy | ±4% |
| Dwell Time Range | 10–90 s (±0.5% timing accuracy) |
| Valid Indentation Depth Range | 0.150–0.350 mm |
| Frame Deflection | ≤0.05 mm |
| Net Weight | 70 kg |
| Dimensions (W×D×H) | 420 × 240 × 640 mm |
| Brand | RHEOTECH |
|---|---|
| Origin | Japan |
| Model | FUDOH RTC-3002D |
| Load Capacity | ±200 N |
| Stroke Range | 0.1–99.9 mm (0.1 mm resolution) |
| Test Speed Options | 2, 5, 6, 10, 20, 30 cm/min or 5, 6, 10, 20, 30, 60 cm/min |
| Display | Triple 3-digit LED (force, displacement, time) |
| Auto-zero Function | Yes |
| Power Supply | 220–250 V AC, 50/60 Hz |
| Dimensions | 260 W × 430 H × 280 D mm |
| Weight | 15 kg |
| Compliance | Designed for ISO 11357, ASTM F3165, USP <1043>, and GLP-compliant texture analysis workflows |
| Brand | Rtec |
|---|---|
| Origin | Switzerland |
| Model | HPT-1000 |
| Maximum Operating Temperature | 1200 °C |
| Maximum Closed-Loop Load | 2000 N |
| Environmental Control | Inert Gas Sealed Chamber (N₂/Ar) |
| Sample Stage | Motorized XY Positioning System |
| Compliance | ASTM E23, ISO 6507, ISO 14577, USP <1031>, FDA 21 CFR Part 11 (Software Module) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Product Type | Imported Instrument |
| Model | DUH-211/211S |
| Instrument Category | Microhardness Tester |
| Force Range | 0.1–1961 mN |
| Maximum Test Load | 1961 mN |
| Force Resolution | 0.196 mN |
| Force Accuracy | ±1% of displayed value |
| Displacement Measurement Range | 0–10 µm |
| Displacement Resolution | 0.0001 µm |
| Indenter | 115° triangular pyramid (Berkovich-type) |
| Optical Magnification | ×500 (with ×50 objective lens) |
| Compliance Standard | ISO 14577-1 Annex A (Martens hardness & material parameter evaluation) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HMV-G Series |
| Instrument Type | Vickers Hardness Tester |
| Test Force Range | 9.807 mN – 19.61 N |
| Maximum Total Test Force | 19.61 N |
| Specimen Space | Horizontal/Vertical travel: Unlimited |
| Depth direction | Up to 200 mm for specimens wider than 120 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC010-LX-A |
| Price | Upon Request |
| Scale Range | 0–100 HA |
| Recommended Measurement Range | 10–90 HA |
| Indenter Travel | 2.5 mm |
| Indenter Tip Diameter | 0.79 mm |
| Dimensions | 115 × 60 × 25 mm |
| Weight | ~0.5 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | MC010-LX-D |
| Price | Upon Request |
| Scale Range | 0–100 HD |
| Recommended Measurement Range | 20–90 HD |
| Indenter Travel | 2.5 mm |
| Indenter Tip Radius | 0.1 mm (SR) |
| Dimensions | 115 × 60 × 25 mm |
| Weight | ~0.5 kg |
| Brand | SOLY |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3NR |
| Instrument Type | Rockwell Hardness Tester |
| Vertical Travel | 200 mm |
| Flat Anvil Diameter | 65 mm |
| V-Anvil Dimensions | Ø47 mm × 127 mm |
| Maximum Specimen Height | 640 mm |
| Base Footprint | 490 × 280 mm |
| Net Weight | 74 kg |
| Indenters Supplied | Diamond Cone (HRC scale), 1/16″ Steel Ball (HRB scale) |
| Hardness Adjustment Discs | Two for HRC, One for HRB |
| Accessories | Adjustable Dial Ring, Crank Handle with Optimized Lever Ratio, Dust-Proof Enclosure, Calibration Certificate, Hardness Conversion Chart, Power Cord, Accessory Storage Case |
| Brand | SOLY |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3R |
| Instrument Type | Rockwell Hardness Tester |
| Vertical Travel | 200 mm |
| Flat Anvil Area | 135 mm |
| Height | 640 mm |
| Footprint | 480 × 220 mm |
| Weight | 65 kg |
| Indenters | Diamond Cone (HRC scale), 1/16″ Steel Ball (HRB scale) |
| Hardness Test Blocks | 2 × C-scale, 1 × B-scale |
| Anvils | Flat Anvil (Ø65 mm), V-Anvil (Ø47 mm & Ø127 mm) |
| Accessories | Elevating Screw Cover Set, Rockwell Hardness Conversion Chart, Power Cord, Accessory Storage Case |
| Brand | SOLY |
|---|---|
| Origin | Italy |
| Type | Shore Hardness Tester (Shore D) |
| Construction | C-frame with weighted diamond-tipped impact hammer |
| Drop height | 19 mm |
| Dimensions (H × W × D) | 360 mm × 150 mm × 162 mm |
| Vertical clearance | 70 mm |
| Base footprint | 60 mm × 150 mm |
| Weight | 16 kg |
| Standard accessories | Soft/hard calibration shims (1 each), V-groove anvil, interface gauge, weight extractor, hardness conversion chart (ISO 868 / ASTM D2240 compliant), carrying case, vinyl protective cover |
| Brand | SOLY |
|---|---|
| Origin | Italy |
| Model | NBH3 |
| Instrument Type | Brinell Hardness Tester |
| Operating Principle | Hydraulic Load Application |
| Vertical Clearance | 200 mm |
| Height | 1100 mm |
| Depth (Front-to-Back) | 155 mm |
| Footprint | 430 × 510 mm |
| Weight | 175 kg |
| Standard Accessories | Brinell measuring microscope, 5 mm & 10 mm indentor holders, Brinell hardness conversion chart, Flat anvil, V-anvil, Storage case with vinyl cover |
| Brand | SOLY |
|---|---|
| Origin | Italy |
| Model | PD-1 |
| Hardness Scale | Shore D |
| Instrument Type | Shore Hardness Tester |
| Height | 245 mm |
| Dial Diameter | 55 mm |
| Measuring Cylinder Diameter | 28 mm |
| Weight | 770 g |
| Compliance | ASTM D2240, ISO 868 |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | AT50 |
| Instrument Type | Oscillating Hardness Tester |
| Compliance | FDA 21 CFR Part 11 Ready |
| Sample Throughput | Up to 10 distinct products per run |
| Measurement Parameters | Weight, Thickness, Width/Diameter/Length, Hardness |
| Alignment Technology | AutoAlign™ and SmartAlign™ |
| Feeding System | Multi-compartment magazine feeder (10 slots) |
| Weighing Platform | Vibration-damped, auto-centering |
| Rejection Mechanism | Real-time fragment & doublet detection |
| Software Integration | q-doc® LIMS-ready data management |