| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 1–3000 HV |
| Operating Temperature Range | Ambient to 800 °C |
| Load Capacity | Standard 30 kgf, Optional 1–150 kgf |
| Optical System | 10× Objective (20× Optional), 1000× Display Magnification (2000× Optional) |
| Temperature Uniformity | ≤ ±5 °C Across 80 × 80 × 60 mm Furnace Chamber |
| Thermal Control Accuracy | ±1 °C |
| Heating Rate | 1–40 °C/min |
| Sample Size Limit | ≤ φ20 × 20 mm |
| Auto-Sample Exchange Time | ≤ 20 s Within Isothermal Field |
| Multi-Axis Motion Control | 4-Axis, Positioning Accuracy ≤ ±1.5 µm |
| Force Resolution | 0.01% FS |
| Load Application Precision | ±2% (≤1 kgf), ±0.5% (>1 kgf) |
| Indenter Material | Cubic Boron Nitride (CBN) Pyramid |
| Optional Indenters | Spherical, Conical, Cylindrical |
| Image Recognition & In-Situ Analysis | Integrated High-Temperature Imaging and Automated Indentation Evaluation |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HMAS-HT900CM |
| Instrument Type | Vickers Hardness Tester |
| Maximum Operating Temperature | 800 °C |
| Load Range | 0.1–30 kgf (standard), up to 150 kgf (optional) |
| Load Control Modes | Constant Load / Constant Loading Rate |
| Load Resolution | 0.01% FS |
| Temperature Uniformity | ≤ ±5 °C across 100 × 80 × 80 mm chamber |
| Temperature Stability | ±1 °C |
| Heating Element | HRE high-temp alloy |
| Thermocouple | Type S |
| Objective Working Temp | ≤ 800 °C (10× or 20×) |
| Optical Magnification | 1000× (standard), 2000× (optional) |
| Objective Resolution | 1.44 µm (10×), 1.19 µm (20×) |
| In-situ Dwell Time | Up to 72 h |
| Sample Size Limit | Ø30 × 30 mm |
| Multi-axis Motion Control | Up to 9 axes |
| Positioning Accuracy | ≤ ±1 µm |
| Z-axis Travel | 12 mm |
| XY Stage Travel (10×) | 250 × 90 mm |
| Sample Exchange Time (in situ) | ≤ 50 s at 800 °C |
| Cooling Options | Circulating water (≤ ±0.3 °C stability), inert gas jet (cool-down ≤ 5 s), optional glovebox (H₂O/O₂ ≤ 1 ppm) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Model | HMAS-UHT1700CM |
| Load Range | 0.1–30 kgf (standard), optional up to 150 kgf |
| Operating Temperature Range | 400–1600 °C (full-field uniformity) |
| Optical Working Temperature | ≤1600 °C (10× or 20× objective) |
| Temperature Control Accuracy | ±1 °C |
| Max. Dwell Time | 72 h |
| Force Resolution | 0.01% FS |
| Multi-Axis Control | Up to 9 axes |
| Sample Size Limit | Ø30 mm × 30 mm |
| Heating Element | U-shaped MoSi₂ (4 units) |
| Thermocouple | Type B |
| Furnace Cavity | 100 × 80 × 80 mm³ |
| Image Magnification | 1000× (10× objective), optional 2000× (20× objective) |
| Objective Resolution | 1.44 µm (10×), optional 1.19 µm (20×) |
| Rapid Sample Exchange | ≤50 s at 1600 °C |
| Cooling | Dual-mode (water + inert gas), ≤5 s cooldown to safe handling |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HR-150A |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | HRA: 20–88, HRB: 20–100, HRC: 20–70 |
| Preliminary Test Force | 98.07 N (10 kgf) |
| Total Test Forces | 588 N (60 kgf), 980 N (100 kgf), 1471 N (150 kgf) |
| Maximum Specimen Height | 170 mm |
| Distance from Indenter Center to Front of Machine | 135 mm |
| Hardness Resolution | 0.5 HR |
| Dimensions (W×D×H) | 466 × 238 × 630 mm |
| Weight | 65 kg |
| Compliance | GB/T 230.2, JJG 112 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HR-150DT |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | HRA: 20–88 |
| HRB | 20–100 |
| HRC | 20–70 |
| Preliminary Test Force | 98.07 N (10 kgf) |
| Total Test Forces | 588 N (60 kgf), 980 N (100 kgf), 1471 N (150 kgf) |
| Maximum Specimen Height | 200 mm |
| Depth from Anvil Center to Front | 135 mm |
| Hardness Resolution | 0.5 HR |
| Dwell Time Adjustment | 0–99 s (1 s increments) |
| Compliance | GB/T 230.2, JJG 112 |
| Power Supply | 220 V AC |
| Weight | 70 kg |
| Dimensions (W×D×H) | 500 × 250 × 700 mm |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HRS-150F |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | HRA: 20–88, HRB: 20–100, HRC: 20–70 |
| Total Test Forces | 588.4 N (60 kgf), 980.7 N (100 kgf), 1471 N (150 kgf) |
| Preliminary Test Force | 98.07 N (10 kgf) |
| Indentation Depth Resolution | 0.1 HR |
| Maximum Specimen Height | 190 mm |
| Anvil-to-Indenter Distance | 160 mm |
| Test Force Dwell Time | 0–60 s (adjustable in 1 s increments) |
| Compliance | GB/T 230.2, JJG 112 |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 540 × 225 × 755 mm |
| Net Weight | 90.5 kg |
| Gross Weight | 110.5 kg |
| Display | 7-inch color TFT touchscreen |
| Data Output | Integrated thermal printer |
| Hardness Scale Conversion | Automatic conversion across 15 Rockwell scales (HRA, HRBW, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRP, HRR, HRS, HRV) and cross-scale equivalents (HBW, HV, HK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rockwell Hardness Tester |
| Model | HRS-150M |
| Measurement Range | HRA: 20–88, HRB: 20–100, HRC: 20–70 |
| Total Test Forces | 588 N (60 kgf), 980 N (100 kgf), 1471 N (150 kgf) |
| Maximum Specimen Height | 180 mm |
| Testing Zone Dimensions | 200 mm (H) × 160 mm (D) |
| Indentation Depth Resolution | 0.1 HR |
| Initial Test Force | 98.07 N (10 kgf) |
| Dwell Time Adjustment | 0–60 s (1 s increments) |
| Compliant Standards | GB/T 230.2, JJG 112 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HV-1000 |
| Instrument Type | Microhardness Tester |
| Hardness Measurement Range | 0.001–6000 HV |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HV-1000 / HV-1000Z |
| Instrument Type | Micro-Vickers Hardness Tester |
| Hardness Range | 0.001–6000 HV |
| Test Forces (8-step) | 0.098 N, 0.245 N, 0.490 N, 0.981 N, 1.961 N, 2.942 N, 4.903 N, 9.807 N |
| Equivalent GF Values | 10 gf, 25 gf, 50 gf, 100 gf, 200 gf, 300 gf, 500 gf, 1000 gf |
| Test Force Standards | HV0.01, HV0.025, HV0.05, HV0.1, HV0.2, HV0.3, HV0.5, HV1 |
| Maximum Specimen Height | 55 mm |
| Depth from Indenter Center to Chamber Wall | 110 mm |
| X-Y Stage Travel | 25 mm × 25 mm |
| Minimum Detection Resolution | 0.5 µm |
| Total Magnification | 100× (observation), 400× (measurement) |
| Optical System | Dual-objective turret (10× observation, 40× measurement), 10× mechanical eyepiece |
| Load Application Mode | Fully automated (loading–dwell–unloading), loading speed: 0.05 mm/s |
| Dwell Time | 0–99 s (1 s increments) |
| Compliance Standard | GB/T 4340.1–2012 (equivalent to ISO 6507-1 and ASTM E384) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 460 mm × 230 mm × 490 mm |
| Construction | Precision cast aluminum frame |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Microhardness Tester |
| Model | HV-1000Z |
| Measurement Range | 0.001–6000 HV |
| Test Forces | 0.098–9.807 N (10–1000 gf), 8 selectable levels |
| Indentation Scales | HV0.01, HV0.025, HV0.05, HV0.1, HV0.2, HV0.3, HV0.5, HV1 |
| Optical Magnification | 100× (observation), 400× (measurement) |
| Minimum Detectable Indentation | 0.25 µm |
| X-Y Stage Travel | 25 × 25 mm |
| Maximum Specimen Height | 70 mm |
| Depth from Indenter to Chamber Wall | 110 mm |
| Load Application | Fully Automatic (loading/holding/unloading) |
| Dwell Time | 0–99 s (1 s increments) |
| Compliance | GB/T 4340 |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 440 × 220 × 460 mm |
| Net Weight | 25.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HV-5/10/30/50 |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0.001–6000 HV |
| Test Forces | 0.2–50 kgf (HV-5: 0.2–5 kgf |
| HV-10 | 0.3–10 kgf |
| HV-30 | 1–30 kgf |
| HV-50 | 1–50 kgf) |
| Objective Magnifications | 10× (observation), 20× (measurement) |
| Eyepiece | 10× mechanical eyepiece |
| Total Magnification | 100× (observation), 200× (measurement) |
| Minimum Detection Unit | 0.25 µm |
| Indentation Measurement Method | Manual micrometer drum reading with automatic hardness calculation |
| Dwell Time | 0–99 s (1-s increments) |
| Max Specimen Height | 220 mm |
| Distance from Indenter to Column | 130 mm |
| Dimensions (H×W×D) | 680 × 216 × 565 mm |
| Power Supply | AC 220 V / 50 Hz |
| Compliance | GB/T 4340.2, JJG 151 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HV-5/10/30/50VE10 |
| Instrument Type | Vickers Hardness Tester |
| Measuring Range | 8–3000 HV |
| Test Force Options | 0.2–50 kgf (with multiple selectable loads across 5/10/30/50 kgf capacity tiers) |
| Objective Lenses | 10× (observation), 20× (measurement for 5/10 kgf) |
| Total Magnification | 100× / 200× (5/10 kgf), 100× (30/50 kgf) |
| Minimum Detectable Indentation Resolution | 0.16 µm (10×), 0.08 µm (20×) |
| Indentation Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 230 mm |
| Distance from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 580 × 375 × 800 mm |
| Net Weight | 47.0 kg |
| Compliance | GB/T 4340, ISO 6507 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | HV-5/10/30/50VE10Z |
| Hardness Tester Type | Vickers Hardness Tester |
| Measuring Range | 8–3000 HV |
| Test Force Options | 0.2–50 kgf (6 force ranges across four capacity tiers) |
| Objective Lenses | 10× (observation), 20× (measurement for 5/10 kgf models) |
| Minimum Detectable Indentation Resolution | 0.16 µm (10×), 0.08 µm (20×) |
| Indentation Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 230 mm |
| Distance from Indenter Axis to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 580 × 375 × 800 mm |
| Net Weight | 47.0 kg |
| Compliance | GB/T 4340, ISO 6507 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HV-5Z |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0.001–6000 HV |
| Test Force Options | 0.2–50 kgf (6 ranges) |
| Loading Mode | Fully Automatic (Load–Hold–Unload) |
| Standards Compliance | GB/T 4340, ISO 6507 |
| Magnification | 100× (observation), 200× (measurement for 5/10 kgf) |
| Objective Lenses | 10× (observation), 20× (measurement, 5/10 kgf only) |
| Eyepiece | 10× Measuring Eyepiece |
| Minimum Detectable Indentation Length | 0.12 µm (10× objective), 0.06 µm (20× objective) |
| Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 235 mm |
| Distance from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 46.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HV-5Z / HV-10Z / HV-30Z / HV-50Z |
| Hardness Tester Type | Vickers Hardness Tester |
| Measuring Range | 0.001–6000 HV |
| Test Forces (kgf) | HV-5Z: 0.2, 0.3, 0.5, 1, 3, 5 |
| HV-10Z | 0.3, 0.5, 1, 3, 5, 10 |
| HV-30Z | 1, 3, 5, 10, 20, 30 |
| HV-50Z | 1, 5, 10, 20, 30, 50 |
| Turret Control | Motorized Auto-Turret |
| Load Application | Fully Automatic Loading/Unloading/Holding |
| Hold Time | 0–99 s (1-s increments) |
| Optical System | Dual-Magnification Objective Lenses (10× observation / 20× measurement), 10× Eyepiece |
| Total Magnification | 100× (observation), 200× (measurement) |
| Minimum Detection Unit | 0.25 µm |
| Measurement Method | Manual indentation diagonal entry via calibrated eyepiece, auto-calculated HV value |
| Display | LCD with dual-scale readout (HV + selectable converted scales) |
| Compliance | GB/T 4340.2, JJG 151 |
| Max Specimen Height | 220 mm |
| Distance from Indenter to Column | 130 mm |
| Dimensions (H×W×D) | 680 × 216 × 565 mm |
| Power Supply | AC 220 V / 50 Hz |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HV-C5/10/30/50VE10 |
| Instrument Type | Vickers Hardness Tester |
| Hardness Measurement Range | 8–3000 HV |
| Test Force Options | 0.2–50 kgf (six selectable force levels per capacity tier) |
| Objective Lenses | 10× (observation), 20× (measurement for 5/10 kgf) |
| Total Magnification | 100× (observation), 200× (measurement, 5/10 kgf) |
| Minimum Detectable Indentation Resolution | 0.16 µm (10×), 0.08 µm (20×) |
| Indentation Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 230 mm |
| Distance from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 580 × 375 × 800 mm |
| Net Weight | 47.0 kg |
| Compliance | GB/T 4340, ISO 6507 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | HV-C5/10/30/50VE10Z |
| Hardness Tester Type | Vickers Hardness Tester |
| Measuring Range | 8–3000 HV |
| Test Forces | 0.2–50 kgf (selectable in six steps per load range) |
| Objective Lenses | 10× (observation), 20× (measurement) for 5/10 kgf models |
| Total Magnification | 100× (observation), 200× (measurement) for 5/10 kgf |
| Minimum Detectable Indentation Resolution | 0.16 µm (10×), 0.08 µm (20×) |
| Indentation Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 230 mm |
| Distance from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 580 × 375 × 800 mm |
| Net Weight | 47.0 kg |
| Compliance | GB/T 4340, ISO 6507 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HVI-5/10/20/30/40/50/100 |
| Hardness Tester Type | Vickers |
| Measurement Range | 8–3000 HV |
| Testing Force Options | 0.2–100 kgf (12–16 selectable steps per load range) |
| Load Application | Motor-driven, fully automatic (loading/holding/unloading) |
| Standards Compliance | GB/T 4340, ISO 6507 |
| Objective Lenses | 10× (observation), 20× (measurement for ≤10 kgf models) |
| Total Magnification | 100× (observation), 200× (measurement for ≤10 kgf) |
| Minimum Detectable Indentation Step | 0.12 µm (10×), 0.06 µm (20×) |
| Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 235 mm |
| Distance from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 46.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | HVI-5/10/20/30/40/50/100MZ |
| Hardness Tester Type | Vickers Hardness Tester |
| Measurement Range | 8–3000 HV |
| Test Force Options | 0.2–100 kgf (12–16 selectable steps per load range) |
| Loading Method | Motor-driven, fully automatic (load-hold-unload) |
| Turret | Automatic |
| Standards Compliance | GB/T 4340, ISO 6507 |
| Eyepiece Magnification | 10× digital eyepiece |
| Objective Lenses | 10× (observation & measurement), 20× (measurement only for ≤10 kgf models) |
| Total Magnification | 100× (observation), 200× (measurement for ≤10 kgf) |
| Minimum Detectable Indentation Step | 0.12 µm (10×), 0.06 µm (20×) |
| Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 235 mm |
| Distance from Indenter to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 46.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Microhardness Tester |
| Measurement Range | 0.001–6000 HV |
| Total Test Forces | 10, 25, 50, 100, 200, 300, 500, 1000 gf |
| Standards Compliance | GB/T 4340 |
| Optical Magnifications | 100× and 400× (dual-scale measurement) |
| Minimum Detectable Indentation Resolution | ~0.013 µm at 400× |
| X-Y Stage Travel | 25 × 25 mm |
| Maximum Specimen Height | 80 mm |
| Data Storage Capacity | Up to 60 test records onboard |
| Integrated Thermal Printer | Yes |
| Power Supply | AC 220 V / 50 Hz |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | HVS-1000BMZ |
| Instrument Type | Microhardness Tester |
| Hardness Measurement Range | 0.001–6000 HV |
| Total Test Forces | 10, 25, 50, 100, 200, 300, 500, 1000 gf |
| Standards Compliance | GB/T 4340 |
| Automation | Fully Automatic Loading/Unloading/Holding |
| Objective Magnifications | 10×, 40× (optional 20×, 50×, 100×) |
| Total Optical Magnifications | 100× and 400× (dual-scale measurement) |
| Minimum Detectable Indentation Resolution | ~0.013 µm at 400× |
| X-Y Stage Travel | 25 × 25 mm |
| Maximum Specimen Height | 80 mm |
| Depth from Indenter to Chamber Wall | 110 mm |
| Data Storage Capacity | Up to 60 test records on-device |
| Integrated Thermal Printer | Yes |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (W×D×H) | 460 × 230 × 490 mm |
| Construction | Cast aluminum body |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HVS-1000M / HVS-1000MZ |
| Price Range | USD 4,100 – 4,780 (FOB Shanghai) |
| Instrument Type | Microhardness Tester |
| Hardness Measurement Range | 0–6000 HV |
| Test Forces | 8-step loading: 0.098 N, 0.245 N, 0.490 N, 0.981 N, 1.961 N, 2.942 N, 4.903 N, 9.807 N |
| Equivalent GF Scale | 10 gf, 25 gf, 50 gf, 100 gf, 200 gf, 300 gf, 500 gf, 1000 gf |
| Test Space | 55 mm (H) × 110 mm (D) |
| Compliance Standard | GB/T 4340.1–2012 (ISO 6507-1 equivalent) |
| Optical Magnification | 100× (observation), 400× (measurement) |
| Minimum Detection Unit | 0.0318 µm |
| X-Y Stage Travel | 25 mm × 25 mm (standard) |
| Force Application Speed | 0.05 mm/s |
| Dwell Time | 0–60 s (1 s increments) |
| Data Storage | Up to 30 test records on-device |
| Integrated Thermal Printer | Yes |
| Power Supply | AC 220 V / 50 Hz |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Microhardness Tester |
| Model | HVS-1000M |
| Measurement Range | 0.001–6000 HV |
| Test Forces | 10, 25, 50, 100, 200, 300, 500, 1000 gf |
| Standards Compliance | GB/T 4340 |
| Optical Magnifications | 100× and 400× (dual-scale measurement) |
| Minimum Detectable Indentation Resolution | ~0.013 µm at 400× |
| X-Y Stage Travel | 25 × 25 mm |
| Max Specimen Height | 65 mm |
| Data Storage | Up to 60 test records onboard |
| Integrated Thermal Printer | Yes |
| Power Supply | AC 220 V / 50 Hz |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Microhardness Tester |
| Model | HVS-1000MZ |
| Measurement Range | 0.001–6000 HV |
| Total Test Forces | 10, 25, 50, 100, 200, 300, 500, 1000 gf |
| Standards Compliance | GB/T 4340 |
| Automation | Motorized Turret, Fully Automatic Loading/Unloading/Holding |
| Optical Magnification | 100× and 400× (dual-magnification measurement system) |
| Minimum Detectable Indentation Resolution | ~0.013 µm at 400× |
| X-Y Stage Travel | 25 × 25 mm |
| Maximum Specimen Height | 65 mm |
| Data Storage | Up to 60 test records onboard |
| Integrated Thermal Printer | Yes |
| Power Supply | AC 220 V / 50 Hz |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | HVS-5M / HVS-10M / HVS-30M / HVS-50M |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0.001–6000 HV |
| Test Force Loading Method | Fully Automatic (Load–Hold–Unload) |
| Standard Compliance | GB/T 4340.2, JJG 151 |
| Eyepiece Magnification | 10× (Digital Eyepiece) |
| Objective Lenses | 10× (Observation), 20× (Measurement) |
| Total Magnification | 100× (Observation), 200× (Measurement) |
| Hardness Display | Electronic LCD Screen (120 × 22 mm) |
| Hardness Scale Conversion | HV, HK, HBW, HRA, HRB, HRC, HRD, HRF, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T |
| Built-in Thermal Printer | Yes |
| Data Acquisition | Manual (via touchscreen or digital eyepiece) |
| Data Calculation | Automatic |
| Optical System | Optimized Brightfield Illumination with Adjustable Intensity |
| Structural Design | Rigid Cast-Iron Frame for Vibration Damping and Long-Term Stability |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IMAS-HT1300CM |
| Instrument Type | Vickers Hardness Tester |
| Temperature Range | 200–1200 °C (furnace up to 1300 °C) |
| Load Range | 0.1–30 kg (optional up to 150 kg) |
| Optical Working Temp | ≤1200 °C (10× or 20× objective) |
| Displacement Resolution | 500 nm (optional down to >20 nm) |
| Holding Time | Up to 72 h |
| Thermal Uniformity | ≤±5 °C across 100×80×80 mm cavity |
| Temperature Control Accuracy | ±1 °C |
| Heating Rate | 1–40 °C/min |
| Max Sample Size | Ø30×30 mm |
| Indenter Max Temp | 1300 °C |
| In-situ Exchange Time | ≤50 s at 1200 °C |
| Multi-axis Control | Up to 9 axes |
| Image Magnification | 1000× (standard), 2000× (optional) |
| Objective Resolution | 1.44 µm (10×), 1.19 µm (20×) |
| Cooling | Dual-mode (water + inert gas), ≤5 s cooldown |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | IMAS-HT1500CM |
| Instrument Type | Vickers Hardness Tester |
| Temperature Range | 400–1400 °C |
| Max Furnace Temperature | 1500 °C |
| Load Range | 0.1–30 kgf (standard), up to 150 kgf (optional) |
| Optical Working Temp | ≤1400 °C (10×/20× objective) |
| Position Resolution | 500 nm (standard), down to >20 nm (laser displacement option) |
| Hold Time | up to 72 h |
| Thermal Uniformity | ≤±5 °C across 100×80×80 mm cavity |
| Temp Control Accuracy | ±1 °C |
| Heating Rate | 1–40 °C/min |
| Sample Size Limit | ≤φ30×30 mm |
| Multi-Axis Control | up to 9 axes |
| Quick-Change Cycle | ≤50 s at 1400 °C |
| Glovebox O₂/H₂O | ≤1 ppm |
| Cooling | Water + inert gas dual-mode |
| Power Supply | 220 V, >6.5 kW |
| Weight | 1800 kg |
| Dimensions | 2400×1500×2350 mm |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | IMAS-HT700CM |
| Instrument Type | Vickers Hardness Tester |
| Maximum Operating Temperature | 600 °C |
| Optical Observation at 600 °C | 10× or 20× Objective |
| Load Range | 0.1–30 kgf (standard), up to 150 kgf (optional) |
| Force Resolution | 0.01% FS |
| Displacement Resolution | 500 nm (standard), down to <20 nm (laser interferometer option) |
| Temperature Control Accuracy | ±1 °C |
| Temperature Uniformity Gradient | ≤±5 °C across 100×80×80 mm chamber |
| Hold Time Capability | Up to 72 h at constant load and temperature |
| In-situ Imaging & Testing | Yes, within same thermal field |
| Multi-axis Synchronization | Up to 9 axes |
| Sample Exchange Time at 600 °C | ≤50 s |
| Heating Element | HRE high-temperature alloy |
| Thermocouple | Type S |
| Cooling | Purified air or inert gas, ≤5 s cooldown to ≤55 °C |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IMAS-HT900CM |
| Instrument Type | Vickers Hardness Tester |
| Maximum Operating Temperature | 800 °C |
| Optical Observation at 800 °C | 10× or 20× Objective |
| Load Range | 0.1–30 kgf (standard), up to 150 kgf (optional) |
| Load Control Modes | Constant Load, Constant Displacement, Constant Velocity |
| Hold Time Capability | Up to 72 h |
| Temperature Uniformity | ≤ ±5 °C across 100 × 80 × 80 mm cavity |
| Thermal Stability | ±1 °C |
| Heating Rate | 1–40 °C/min |
| High-Temperature Imaging Resolution | 1.44 µm (10×), optional 1.19 µm (20×) |
| In-situ Displacement Resolution | 500 nm (standard), optional >20 nm (laser interferometry) |
| Multi-axis Synchronization | Up to 9 axes |
| Sample Exchange Time at 800 °C | ≤50 s |
| High-Temperature Objective Working Duration | ≤50 h |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | IMAS-UHT1700CM |
| Instrument Type | Vickers Hardness Tester |
| Temperature Range | 400–1600 °C |
| Max Furnace Temperature | 1700 °C |
| Load Range | 0.1–30 kgf (standard), optional up to 150 kgf |
| Load Accuracy | ≤±2% at ≤1 kgf |
| Displacement Resolution | 500 nm (standard), optional down to 20 nm (laser interferometry) |
| Optical Working Temperature | ≤1600 °C (10× or 20× objective) |
| Hold Time Capability | Up to 72 h at target temperature and load |
| Thermal Uniformity | ≤±5 °C across 100×80×80 mm furnace cavity |
| Heating Rate | 1–40 °C/min |
| Thermocouple Type | B-type |
| Heating Element | Four U-shaped MoSi₂ rods |
| Sample Size Limit | Ø30×30 mm |
| In-situ Exchange Time | ≤50 s at 1600 °C |
| Multi-axis Control | Up to 9 synchronized axes |
| Image Magnification | 1000× (10× objective), optional 2000× (20× objective) |
| Objective Resolution | 1.44 µm (10×), optional 1.19 µm (20×) |
| Cooling | Dual-mode (water + inert-gas quenching) |