Empowering Scientific Discovery

Jiangsu Schuetz Measurement & Control Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginSwitzerland
ModelPAROX 1200
Measurement PrincipleParamagnetic Detection
O₂ Range Options0–25 %, 0–100 %, or Custom (e.g., 0–x %, x–100 %)
Output Signals0–1 V, 0–4 V, 4–20 mA
Gas Inlet Ports3 mm, 1/8", or 5 mm internal thread
Flow RequirementsDirect flow (10–150 mL/h), Internal fixed bypass (17–70 L/h), External flow control (10–90 L/h, optional module)
Gas PreheatingOptional integrated heater
Lifetime>5 years typical operational service life under specified conditions
Cross-sensitivityNegligible to CO₂, N₂, Ar, CH₄, H₂O (vapor), and common industrial gases
Operating Temperature-10 °C to +50 °C
Enclosure RatingIP65
ComplianceCE, RoHS, ATEX Category 3G (optional variant)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchutz SIGAS
OriginGermany
ModelCoMo 170 Portable High-Sensitivity Alpha/Beta/Gamma Surface Contamination Monitor
Detector TypePlastic Scintillation Detector (Alpha/Beta/Gamma Sensitive)
Detection Area170 cm²
Measurement Unitscps, Bq, Bq/cm²
Power SupplyRechargeable Battery (Portable Operation)
ComplianceCE, DIN 6818-1, IEC 60846-1
Optional AccessoriesExternal GM Dose Rate Probe, Desktop Stand, Data Export Software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginGermany
ModelSPTr-GAS PORT 200
TypePortable Multicomponent Gas Analyzer
Detection PrinciplePhotoacoustic Spectroscopy (PAS)
Response Time≤10 s
Repeatability±1% FS for SO₂F₂ and CH₃Br
Detection GasesSulfuryl Fluoride (SO₂F₂), Methyl Bromide (CH₃Br), Phosphine (PH₃)
Measurement RangesSO₂F₂: 1–150 g/m³ (PRO) / 0.5–200 ppm (CLIR)
CH₃Br & PH₃matching trace/high-range configurations
Accuracy±1% FS (full scale) or ±0.5 ppm (<10 ppm)
Resolution0.1 g/m³ (PRO) / 0.5 ppm (CLIR)
Warm-up Time5 min (PRO) / 15 min (CLIR)
Display1×8-character LCD
Power SupplyNiMH Battery Pack (19.2 V, 72 Ah)
AC Input100–240 VAC, 47–64 Hz, max. 110 W
Battery Runtime>26 h (PRO) / >5 h (CLIR)
Charging Time3.5 h
Operating Temperature+5 °C to +40 °C
Storage Temperature−10 °C to +60 °C
Relative Humidity0–95% RH, non-condensing
Dimensions230 × 105 × 270 mm
Weight3.5 kg (PRO) / 4.3 kg (CLIR)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginJiangsu, China
ModelS-ANALYZER 200 V5.0
Instrument TypeOnline Fixed-Mount Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Number of ChannelsUp to 5 Simultaneous Gas Components
Measurement Range (Min)0–50 ppm
Repeatability±1% FS
Resolution0.1 ppm
Response Time (T90)<2 s at 60 L/h flow rate
Zero Drift<±1% FS / 7 days
Span Drift<±1% FS / 7 days
Linearity Error<±2% FS
Operating Flow Rate0.2–1.2 L/min (±0.02 L/min stability required)
Inlet Temperature5–35 °C
Inlet Pressure≤116 kPa (abs)
Inlet HumidityNon-condensing
Particulate Load≤100 µg/m³, particle size ≤1 µm
Display5.6" TFT LCD touch screen
Analog Output4–20 mA (configurable), 2 mA fault signal
Digital CommunicationRS232 (DB9 female), RS485 Modbus RTU
Relay Outputs6 configurable dry-contact relays (1 A @ 250 V AC / 2 A resistive)
Power Supply198–242 V AC, 50/60 Hz, <125 W
Enclosure RatingIP41 (EN 60529)
Weight~10 kg (net), ~19 kg (packaged)
Calibration GasesZero gas — 99.999% N₂
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS (Schütz Mess- und Regeltechnik)
OriginGermany
ModelSilarex
Detection PrincipleDual-Beam Non-Dispersive Infrared (NDIR)
Measurement RangeCO₂ up to 20 vol.%, CO up to 1000 ppm, NO up to 2000 ppm, SO₂ up to 1000 ppm
Response Time (T90)< 8 s @ 0.7 L/min
Repeatability≤ ±1 % FS
Linearity Error≤ ±1 % FS (standard), ≤ ±1.5 % FS (select versions)
Stability< ±2 % FS over 1000 h
Operating Temperature0–40 °C (up to 45 °C with thermostatic housing)
Storage Temperature−20–60 °C
Humidity0–95 % RH (non-condensing)
Pressure Range800–1150 mbar
Flow Rate0.2–1.0 L/min (stable)
Warm-up Time< 2 min (cold start), < 30 min (full thermal stabilization)
Power Supply24 VDC ±0.3 V
Max. Current Draw1.5 A (heating chamber active)
Heating Setpoint42 °C (sensor core), 45 °C (with aluminum thermostatic housing)
Digital InterfaceModbus ASCII/RTU over TTL, auto-baud & auto-frame
Gas Inlet3 mm ID / 5 mm OD tubing connection
Optical CellGold-coated reflective chamber
Cross-Interference SuppressionEngineered spectral deconvolution and multi-wavelength compensation
Zero-Point ResolutionCO₂ 0.01 vol.%, CO 0.1 ppm, NO 1 ppm, SO₂ 1 ppm
LODCO₂ 0.1 %FS, CO 0.5 %FS, NO 1 %FS, SO₂ 1 %FS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
ModelSPTr-GAS® ANALYZER V3.0
Detection PrinciplePhotoacoustic Spectroscopy (PAS)
Target GasesNH₃, CH₃Br, C₂H₆O, C₃H₈O, CH₄O, SO₂, SF₆, C₂Cl₄, NF₃, N₂O, C₈H₈, C₂HCl₃F₂, C₂HCl₂F₃, CClF₃, CF₄, CHClF₂, CHF₃, C₂F₆, CCl₂F₂, C₂HCl₃, C₈H₂₀O₄Si, etc.
Response Time< 20 s
Detection Limit< 0.01 % FS (varies by range)
Measurement RangeConfigurable per application (e.g., NH₃: 0–100 ppm or 0–1 g/m³
CH₃Br0–2 g/m³)
Accuracy±0.1 % FS typical (±0.5 ppm for sub-ppm ranges)
Zero Stability< 0.1 % FS/24 h
Operating TemperatureMaintained at 50 °C (±0.5 °C) internally
Humidity CompensationIntegrated IR humidity sensor inside PAS cell
Display5.6” resistive touchscreen LCD
Analog Output4–20 mA (2 mA fault signal)
Digital InterfaceRS232 (9600 baud, 8N1)
Power198–242 V AC, 50/60 Hz
Weight~15 kg
Enclosure RatingIP42
ComplianceEN60320-C1 power inlet, EN60529, CE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginGermany
ModelSPTr-GAS PORT 100
TypePortable Analyzer
Response Time≤10 s
Target GasesSulfuryl Fluoride (SO₂F₂), Methyl Bromide (CH₃Br), Phosphine (PH₃), Ethylene Oxide (C₂H₄O)
Repeatability±2% of reading (for SO₂F₂, CH₃Br, PH₃)
CalibrationAuto-zero and manual zero options
DisplayIntegrated touchscreen interface with analog + digital readout
ComplianceDesigned for field-deployable fumigant residue verification per ISPM No. 18, EN 14603, and EPA Method TO-15 derivations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchutz SIGAS
OriginGermany
TypePortable
DetectorEnergy-Compensated Geiger-Müller Tube
Radiation TypesSimultaneous γ and X-ray Measurement
DisplayDual LCD with backlight (dose & dose rate)
Dose Range0.5 µSv to 1 Sv
Dose Rate Range0.5 µSv/h to 50 mSv/h
Environmental Dose EquivalentH*(10) and Ḣ*(10)
IP RatingIP54
Dimensions28 × 67 × 105 mm
Weight~200 g (with batteries)
Data LoggingInternal non-volatile memory
Alarm Thresholds4 factory-preset, user-adjustable
External Probe InterfaceYes (e.g., ABG170, ZP1083D, NaI-2002)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
ModelSA-TR96/91
Detection PrincipleElectrochemical & Frequency-Modulated Ion Current
Measurement Range0–10 ppm to 0–25% O₂ (selectable)
Accuracy±1% FS (0–1000 ppm and above), ±3% FS (0–100 ppm), ±5% FS (0–10 ppm)
Repeatability & Stability±1% FS (≥100 ppm), ±1.5% FS (0–100 ppm), ±2.5% FS (0–10 ppm)
Response Time (T90)<60 s at 25°C
Recovery Time (20.94% → 10 ppm)≤60 min
Operating Pressure35–210 kPa (absolute), flow-controlled at 1.0–1.5 L/min (recommended: 1.2 L/min)
Ambient Temp.0–45°C
Humidity<80% RH
Power Supply85–264 VAC, 50/60 Hz, <20 VA
Output SignalsIsolated 4–20 mA (configurable to 0–20 mA / 0–1 V / 0–5 V / 0–10 V / 1–5 V)
CommunicationRS485 (standard), RS232 (optional)
Gas Inlet1/8″ stainless steel
Enclosure Dimensions144 × 144 × 251 mm (L×W×D)
Mounting Hole Pattern136 × 136 mm
Sensor Lifetime>2 years (typical use)
Analyzer Lifetime>5 years (typical use)
ComplianceDesigned for continuous industrial gas monitoring per IEC 61000-6-2/6-4 EMI immunity & emission requirements
CertificationsCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginJiangsu, China
ModelSPTr-GAS®300 Tracer
TypePortable
Response Time<20 s
Repeatability±0.1% FS for NH₃, CH₃Br, SO₂, etc.
Operating Temperature50 °C (thermostatically stabilized)
Detection PrinciplePhotoacoustic Spectroscopy (PAS)
Dimensions483 mm × 390 mm × 177 mm (19″ 1/2-rack form factor)
Weight~15 kg
Enclosure RatingIP42
Power Supply198–242 V AC, 50/60 Hz
Analog Output4–20 mA (250–350 Ω load)
CommunicationRS223 (7-pin blue/black cable)
Preheat Time~30 min
Resolution0.1 ppm (typical, gas-dependent)
Zero CalibrationAuto or manual air-based calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS (Schütz Mess- und Regeltechnik)
OriginSwitzerland
ModelFoxsense PAROX 2000 Plus
Measurement PrincipleHigh-Sensitivity Paramagnetic Detection
Operating Temperature RangeUp to 55°C continuous
Enclosure19" 3U Rack-Mounted
Dimensions (W×H×D)482 × 133 × 245 mm
IP RatingIP20
Sensor CoreIntegrated Parox1200 Paramagnetic Sensor
CalibrationFully Parameterized Auto-Calibration
Channel ConfigurationSingle or Dual (MULTI2000Plus option)
Gas Path MaterialsViton® or PVDF
Gas Inlet/Outlet4 mm or 6 mm PVDF tubing with stainless steel compression fittings
Pressure Compensation OptionsNone / Electronic / Integrated Pressure Regulator / External Pressure Input (sensor not included)
Flow Monitoring OptionsNone / Mechanical Flowmeter / Electronic Flowmeter with Display & Alarm
Oxygen Range Options0–25% O₂
Pump OptionsNone / Integrated Sampling Pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchuetz SIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelSILAREX-TOC
Price RangeUSD 2,800 – 7,000
Detection PrincipleNon-Dispersive Infrared (NDIR), Dual-Beam
Measured GasCO₂ (as TOC surrogate)
Ranges0–100 ppm (±2 ppm), 0–1,000 ppm (±20 ppm), 0–10,000 ppm (±100 ppm)
LOD0.15 ppm
Response Time (T90)<8 s @ 0.7 L/min
Repeatability≤ ±1 % FS
Linearity Error≤ ±1 % FS (≤ ±1.5 % FS optional)
Stability< ±2 % FS over 1,000 h
Operating Temp.0–40 °C
Storage Temp.−20–60 °C
Humidity0–95 % RH (non-condensing)
Pressure Range800–1,150 mbar
Flow Rate0.2–1.0 L/min
Warm-up Time<2 min (cold start), <30 min (thermal equilibrium)
Power Supply24 VDC ±0.3 V
Max. Current Draw1.5 A (heating active)
Power Consumption<800 mW (idle), up to 36 W (heating)
Digital OutputModbus ASCII/RTU (TTL, auto-baud 2400–115.2 kbps)
Analog OutputOptional 4–20 mA or 0–10 V
Internal Heater Setpoint42 °C
Gas Inlet/Outlet3 mm ID / 5 mm OD tubing
Chamber MaterialElectropolished Aluminum
Optical WindowFluorinated Glass
Wavelength4.26 µm (2350 cm⁻¹)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginJiangsu, China
ModelSPGAS PORT 110
TypePortable
Response Time<30 s (t₉₀ @ 36 L/h stable flow)
RepeatabilityH₂S, SO₂F₂, CH₃Br, CO, CO₂, O₂, etc.
Measurement ChannelsUp to 3
Display4.9" TFT LCD
PowerRechargeable Li-ion battery (≥8 h operation @25°C)
CommunicationRS232 (DB-9F), USB, optional Bluetooth 2.0 (10 m range, BQB/FCC certified)
Safety CertificationsUL 62368-1, CSA C22.2 No. 62368-1, TÜV EN 62368-1, CCC GB4943.1
Preheat TimeNDUV ≤1 h, NDIR ≤15 min, EC ≤10 min (cold start @25°C)
Sampling Flow3 ± 0.5 L/min (integrated low-noise diaphragm pump)
Operating Temp5–40°C (measurement), 0–45°C (charging)
Humidity0–95% RH (non-condensing)
Pressure Range76–116 kPa
Sample Gas Requirements5–40°C, no condensate, particulates <100 µg/m³ (<1 µm), external filtration recommended
Data StorageInternal memory + USB export (FAT32, up to 16 GB)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS (Schütz Mess- und Regeltechnik)
OriginSwitzerland
ModelFoxsense MULTi 2000 Plus
Form FactorRack-Mount (19" 3U)
Channel ConfigurationSingle or Dual Channel
Enclosure OptionsIP20 (bare rack unit) or IP52 (enclosed rack version)
Dimensions (IP20)482 × 133 × 245 mm
Dimensions (IP52)500 × 143 × 260 mm
Response Time (T90)≤30 s
Measured GasesCH₄, CO₂, CO, O₂
Gas SamplingContinuous online flow-through
ComplianceDesigned for industrial process monitoring and biogas quality control per EN 16726, ISO 8573-1 (compressed air purity), and applicable IEC 61000-6-2/4 EMC standards
Regulatory ContextSupports GLP/GMP-aligned data integrity when integrated with audit-trail-enabled SCADA or DCS systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginGermany
ModelS-MODULE BasicEVO
Detection PrincipleNon-Dispersive Infrared (NDIR), Dual-Beam
Measurement RangeSee Standard Model List
Sampling MethodDiffusion
Response Time (T90)≤30 s
Resolution (@zero)1 ppm to 0.1 vol.%
LOD (3σ)≤±1 % FS
Repeatability≤±1.5 % FS
Linearity Error≤±2 % FS
Zero Stability≤±3.0 % FS / 12 months (typ.)
Span Stability≤±2.5 % FS / 12 months (typ.)
Zero Temp. Drift≤±0.15 % FS / °C (typ.)
Span Temp. Drift≤±0.3 % FS / °C (typ.)
Pressure Drift±0.1–0.2 % of reading per mbar
Operating Temp.–20 °C to +40 °C (model-dependent)
Storage Temp.–20 °C to +60 °C
Humidity0–95 % RH (non-condensing)
Pressure Range800–1150 mbar
Warm-up Time<2 min (cold start), <11 min (slow start), <30 min (full spec.)
Digital OutputModbus ASCII/RTU over TTL, auto-baud (2400–115.2 kbps)
Analog Outputs0/4–20 mA (with S-Connect), 0/0.2–1 V (with S-Connect V), RS-232/RS-485 (with respective S-Connect modules)
Supply Voltage3.3–6 VDC ±5 %
Avg. Current Draw120 mA @5 VDC, peak <400 mA @3.3 VDC / <240 mA @5 VDC
Power Consumption<0.8 W (avg.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelFLOWEVO
PricingUpon Request
Detection PrincipleNon-Dispersive Infrared (NDIR), Dual-Beam
Gas TargetsMethyl Bromide (CH₃Br), Sulfuryl Fluoride (SO₂F₂)
Response Time (T90)≤12 s @ 0.7 L/min
Resolution (@ zero)1 ppm to 0.1 vol.%
LOD (3σ)≤1% FS
Repeatability≤±1% FS
Linearity Error≤±1.0% FS (standard), ≤±1.5% FS (select versions)
Zero Drift≤±2% FS over 12 months
Span Drift≤±2% FS over 12 months
Temp. Drift (Zero)≤±0.1% FS/°C
Temp. Drift (Span)≤±0.15% FS/°C
Pressure Drift0.1–0.2% reading/mbar
Operating Temp.0–50°C
Storage Temp.−20–60°C
Humidity0–95% RH (non-condensing)
Pressure Range800–1200 mbar
Warm-up Time<2 min (cold start), <30 min (full spec.)
Flow Rate0.1–1.0 L/min (stable)
Digital OutputModbus ASCII RTU (TTL, 2400–115.2 kbaud, auto-baud/auto-frame)
Analog Output (optional w/ FLOWEVO plus controller)4–20 mA, 0–1 V, 0–5 V, 0–10 V DC
Signal OutputTTL-level single-channel
Chamber Pressure CompensationActive
HeatingIntegrated active heating for condensation & drift mitigation
Supply Voltage3.3–6 V DC ±5% (sensor only)
Current Draw<240 mA @ 5 V (avg., no heating)
Power Consumption<800 mW (no heating)
HousingAnodized aluminum
Inlet Connection3 mm ID / 5 mm OD flexible tubing
Expected Service Life≥10 years
Maintenance RequirementMinimal (no consumables, no chemical degradation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
ModelS-ANALYZER ATEX V5.0
TypeOnline Industrial Explosion-Proof Multicomponent Gas Analyzer
PrincipleNon-Dispersive Infrared (NDIR) Absorption
ChannelsUp to 5 simultaneous gas measurements
Response Time<25 s (t90 @ 60 L/h constant flow)
RepeatabilityCH₄, CO, CO₂, O₂, and other supported gases
Enclosure RatingEx d IIC T6 Gb (certified per GB3836.1–2010 & GB3836.2–2010, NEPSI certified)
Operating Temperature5–45 °C
Inlet Flow Rate0.4–0.8 L/min (±0.02 L/min stability)
Power Supply(198–242) V AC, 50/60 Hz, <125 W
Weight~50 kg
DimensionsNot specified in input
Analog Output4–20 mA (2 mA fault signal), load: 250–350 Ω
Relay Outputs6 configurable dry-contact relays (1 A @ 250 V AC / 2 A resistive)
Gas InletNPT 1/8″ female
Moisture RequirementNon-condensing
Particulate Limit≤100 µg/m³, ≤1 µm
Zero Gas99.999% N₂
Span Gas Range75–125% of full scale
Mid-point Calibration Gas37.5–62.5% of full scale
Ingress ProtectionNot explicitly stated
ComplianceGB3836.1/2–2010, NEPSI-certified, suitable for Zone 1/21 hazardous areas
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginJiangsu, China
ModelS-ANALYZER 200 NDUV
Instrument TypeOnline Gas Analyzer
Detection PrincipleNon-Dispersive Ultraviolet (NDUV) Absorption
Maximum Permissible Error≤ ±2% FS
Zero Drift≤ ±2% FS / 24 h
Span Drift≤ ±2% FS / month
Repeatability≤ ±1% FS
Response Time<25 s (at 60 L/h stable flow)
Warm-up Time3–30 min (at 20°C, depending on detector configuration)
Resolution0.01% (O₂ channel), 0.1 µmol/mol (for SO₂/NO/NO₂/etc.)
Operating Flow Rate(0.2–1.2) L/min (±0.02 L/min stability required)
Inlet Temperature5–35°C
Inlet Pressure≤116 kPa
Dew Point5°C ±0.1°C (mandatory for SO₂/NO channels)
Particulate Load≤100 µg/m³, ≤1 µm
Zero Gas99.999% N₂
Span Gas75–125% of full scale
Mid-point Calibration Gas37.5–62.5% of full scale
Analog Output4–20 mA (normal operation), 2 mA (fault/alarm/preheat)
Digital Outputs6 relay channels (configurable for fault, auto-calibration control, and concentration alarms)
CommunicationRS232 (DB9 female), RS485 Modbus RTU
Power Supply198–242 V AC, 50/60 Hz, <125 W
Enclosure RatingIP41 (EN 60529)
Weight~10 kg (net), ~19 kg (packaged)
Display5.6" color LCD touchscreen with tri-screen interface (numerical status, detailed parameters, real-time concentration curves)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz / SIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSPGAS PORT mini
PriceUpon Request
Measurement Channels3
Sensor TechnologiesNDIR, Electrochemical (EC), and other modular principles
Display4.9" TFT LCD
Response Time (t₉₀)<30 s @ 36 L/h stable flow
Sampling Flow Rate3 ± 0.5 L/min (integrated low-noise diaphragm pump)
Operating Temperature5–40 °C
Storage Temperature–20–60 °C
Battery Life≥8 h (fully charged, 25 °C)
Charging Time~5 h (5% to 90%, 25 °C)
Power Input100–260 VAC, 47–63 Hz
DC Output24 VDC, 0–6 A
Safety CertificationsUL 62368-1, CSA C22.2 No. 62368-1, TÜV EN 62368-1, CCC GB4943.1
Preheat Time≤15 min (NDIR), ≤10 min (EC), cold start @25 °C
Ingress ProtectionIP54 (enclosure)
Data InterfaceRS232 (DB9-F), USB Type-A, optional Bluetooth 2.0 (2.4 GHz, ~10 m line-of-sight, BQB/FCC certified)
Data ExportFAT32-formatted USB flash drive (up to 16 GB)
Display Resolution0.1 g/m³
Alarm OutputsRelay & visual/audible alerts
Zero CalibrationOne-button auto-zero, configurable auto-zero on power-up
Internal FiltrationIntegrated particulate and hydrophobic protection filter
Gas Inlet1/8" NPT female
Sample Gas Requirements5–40 °C, non-condensing, particulates <100 µg/m³ (<1 µm), external filtration recommended for harsh environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchutz SIGAS
OriginGermany
ModelGPD150G
Instrument TypePortable Dose/Dose Rate Meter
Detector TypeEnergy-Compensated Geiger-Müller Tube
Measured QuantityHp(10) (Deep Personal Dose)
Radiation TypeGamma and X-ray
Energy Range55 keV – 1.3 MeV
Dose Range1 µSv – 10 Sv
Protection RatingIP54
Battery LifeUp to 3 months (8 h/day) under ambient background radiation
Alarm FunctionsAudible, visual, and vibration alerts for dose & dose rate thresholds
Predefined Warning LevelsFour user-selectable dose thresholds + one factory-set dose rate threshold
Data RetentionPersistent memory during battery replacement
Operating ModeSingle-pulse acoustic detection (switchable)
AccessoriesBelt clip and protective holster
ComplianceDesigned in accordance with IEC 61526:2010 and IEC 62387-1:2012 for personal dosimetry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Regional CategoryDomestic (PRC)
ModelSPTr-GAS® ANALYZER
Instrument TypeOnline Gas Analyzer
Detection PrinciplePhotoacoustic Spectroscopy (PAS)
Typical LOD< 0.01 % FS
Response Time (T90)< 20 s
Warm-up Time~15 min to 50 °C at 20 °C ambient
Display5.6" Touchscreen LCD
Analog Output4–20 mA (configurable range), 2 mA fault signal
Digital I/O6 relay outputs (programmable per channel)
CommunicationRS232 (DB9-M), RS485 Modbus RTU
Power Supply198–242 V AC, 50/60 Hz, < 125 W
Enclosure RatingIP41 (EN 60529)
Weight~10 kg (net), ~19 kg (packaged)
Sample Flow Rate0.2–1.2 L/min (±0.02 L/min stability required)
Inlet Temp5–35 °C
Inlet Pressure≤116 kPa
Inlet HumidityNon-condensing
Particulate Load≤100 µg/m³, ≤1 µm
Zero Gas99.999% N₂
Span Gas75–125% of full scale
Mid-point Calibration Gas37.5–62.5% of full scale
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
ModelSPTr-GAS® PORT 200
Detection PrinciplePhotoacoustic Spectroscopy (PAS)
Dimensions (H×W×D, incl. handle & ports)230 mm × 105 mm × 270 mm
Weight~4.3 kg
Power SupplyInternal NiMH battery (19.2 V, 4.5 Ah)
Operating Time>4 h (fully charged)
Charging Time~3.5 h
Operating Temperature+5 °C to +40 °C
Storage Temperature−10 °C to +60 °C
Humidity Range0–95% RH (non-condensing)
Display1×8-character LCD with red backlight
Accuracy±0.5 ppm (0–10 ppm range)
Resolution0.5 ppm (residual gas)
Integrated CompensationActive temperature stabilization (50 °C heated PAS cell), real-time humidity sensing, multi-gas interference rejection via spectral signal discrimination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginGermany
ModelX5C Plus
Instrument TypePortable Ambient Dose Equivalent Rate Meter (for H*(10))
Detector TypeEnergy-Compensated Geiger-Müller Tube
Measurement QuantityAmbient Dose Equivalent Rate Ḣ*(10) and Integrated Dose H*(10)
DisplayBacklit LCD with Logarithmic Bar Graph (3.5-decade)
AlarmProgrammable Acoustic/Visual Thresholds for Dose & Dose Rate
Data LoggingTime-Stamped Automatic & Manual Storage
ConnectivityRS-232 Interface
EnclosureIP67-rated Metallized Plastic Housing
Dimensions152 × 82 × 39 mm
Weight~385 g
Dose Range0.5 µSv – 10 Sv
Dose Rate Range1 µSv/h – 19.99 mSv/h
CompliancePTB-Type Approved (Germany)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
ModelS-MODULE EVO
Detection PrincipleNon-Dispersive Infrared (NDIR), Dual-Beam
Measurement RangeConfigurable per gas (e.g., CO₂: 100 ppm to 100% vol
CO2,000 ppm to 100% vol
CH₄5,000 ppm to 100% vol
SF₆50 ppm to 100% vol
SO₂2,000 ppm
N₂O500 ppm)
Operating Temperature0 °C to 50 °C
Storage Temperature−20 °C to 60 °C
Relative Humidity0–95% RH (non-condensing)
Pressure Range800–1200 mbar
Response Time (T90)<3 sec (Fast Mode), <14 sec (Standard Mode)
Zero Drift≤ ±2% FS / 12 months
Span Drift≤ ±2% FS / 12 months
Temperature Drift (Zero)≤ ±0.1% FS/°C
Temperature Drift (Span)≤ ±0.15% FS/°C
Pressure Drift0.1–0.2% of reading per mbar
Power Supply10–26 VDC (recommended 24 VDC)
Digital OutputRS232, RS485, Modbus ASCII/RTU, EVO-proprietary protocols
Analog Output Options0/4–20 mA (isolated), 0–1/2/5/10 VDC
Flow Rate0.1–1.0 L/min (pump-suction)
Tubing Connection3 mm ID / 5 mm OD
HousingAnodized aluminum with integrated thermal insulation and optional active heating
Gas CellGold-coated, temperature-stabilized
Pressure CompensationOptional internal chamber or ambient pressure compensation
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0