- All
- Favorite
- Popular
- Most rated
| Brand | Schütz SIGAS |
|---|---|
| Origin | Germany |
| Model | SPTr-GAS PORT 200 |
| Type | Portable Multicomponent Gas Analyzer |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Response Time | ≤10 s |
| Repeatability | ±1% FS for SO₂F₂ and CH₃Br |
| Detection Gases | Sulfuryl Fluoride (SO₂F₂), Methyl Bromide (CH₃Br), Phosphine (PH₃) |
| Measurement Ranges | SO₂F₂: 1–150 g/m³ (PRO) / 0.5–200 ppm (CLIR) |
| CH₃Br & PH₃ | matching trace/high-range configurations |
| Accuracy | ±1% FS (full scale) or ±0.5 ppm (<10 ppm) |
| Resolution | 0.1 g/m³ (PRO) / 0.5 ppm (CLIR) |
| Warm-up Time | 5 min (PRO) / 15 min (CLIR) |
| Display | 1×8-character LCD |
| Power Supply | NiMH Battery Pack (19.2 V, 72 Ah) |
| AC Input | 100–240 VAC, 47–64 Hz, max. 110 W |
| Battery Runtime | >26 h (PRO) / >5 h (CLIR) |
| Charging Time | 3.5 h |
| Operating Temperature | +5 °C to +40 °C |
| Storage Temperature | −10 °C to +60 °C |
| Relative Humidity | 0–95% RH, non-condensing |
| Dimensions | 230 × 105 × 270 mm |
| Weight | 3.5 kg (PRO) / 4.3 kg (CLIR) |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Germany |
| Model | SPTr-GAS PORT 100 |
| Type | Portable Analyzer |
| Response Time | ≤10 s |
| Target Gases | Sulfuryl Fluoride (SO₂F₂), Methyl Bromide (CH₃Br), Phosphine (PH₃), Ethylene Oxide (C₂H₄O) |
| Repeatability | ±2% of reading (for SO₂F₂, CH₃Br, PH₃) |
| Calibration | Auto-zero and manual zero options |
| Display | Integrated touchscreen interface with analog + digital readout |
| Compliance | Designed for field-deployable fumigant residue verification per ISPM No. 18, EN 14603, and EPA Method TO-15 derivations |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | SPTr-GAS®300 Tracer |
| Type | Portable |
| Response Time | <20 s |
| Repeatability | ±0.1% FS for NH₃, CH₃Br, SO₂, etc. |
| Operating Temperature | 50 °C (thermostatically stabilized) |
| Detection Principle | Photoacoustic Spectroscopy (PAS) |
| Dimensions | 483 mm × 390 mm × 177 mm (19″ 1/2-rack form factor) |
| Weight | ~15 kg |
| Enclosure Rating | IP42 |
| Power Supply | 198–242 V AC, 50/60 Hz |
| Analog Output | 4–20 mA (250–350 Ω load) |
| Communication | RS223 (7-pin blue/black cable) |
| Preheat Time | ~30 min |
| Resolution | 0.1 ppm (typical, gas-dependent) |
| Zero Calibration | Auto or manual air-based calibration |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | SPGAS PORT 110 |
| Type | Portable |
| Response Time | <30 s (t₉₀ @ 36 L/h stable flow) |
| Repeatability | H₂S, SO₂F₂, CH₃Br, CO, CO₂, O₂, etc. |
| Measurement Channels | Up to 3 |
| Display | 4.9" TFT LCD |
| Power | Rechargeable Li-ion battery (≥8 h operation @25°C) |
| Communication | RS232 (DB-9F), USB, optional Bluetooth 2.0 (10 m range, BQB/FCC certified) |
| Safety Certifications | UL 62368-1, CSA C22.2 No. 62368-1, TÜV EN 62368-1, CCC GB4943.1 |
| Preheat Time | NDUV ≤1 h, NDIR ≤15 min, EC ≤10 min (cold start @25°C) |
| Sampling Flow | 3 ± 0.5 L/min (integrated low-noise diaphragm pump) |
| Operating Temp | 5–40°C (measurement), 0–45°C (charging) |
| Humidity | 0–95% RH (non-condensing) |
| Pressure Range | 76–116 kPa |
| Sample Gas Requirements | 5–40°C, no condensate, particulates <100 µg/m³ (<1 µm), external filtration recommended |
| Data Storage | Internal memory + USB export (FAT32, up to 16 GB) |
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Switzerland |
| Model | Foxsense MULTi 2000 Plus |
| Form Factor | Rack-Mount (19" 3U) |
| Channel Configuration | Single or Dual Channel |
| Enclosure Options | IP20 (bare rack unit) or IP52 (enclosed rack version) |
| Dimensions (IP20) | 482 × 133 × 245 mm |
| Dimensions (IP52) | 500 × 143 × 260 mm |
| Response Time (T90) | ≤30 s |
| Measured Gases | CH₄, CO₂, CO, O₂ |
| Gas Sampling | Continuous online flow-through |
| Compliance | Designed for industrial process monitoring and biogas quality control per EN 16726, ISO 8573-1 (compressed air purity), and applicable IEC 61000-6-2/4 EMC standards |
| Regulatory Context | Supports GLP/GMP-aligned data integrity when integrated with audit-trail-enabled SCADA or DCS systems |
| Brand | SIGAS |
|---|---|
| Model | S-ANALYZER ATEX V5.0 |
| Type | Online Industrial Explosion-Proof Multicomponent Gas Analyzer |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Channels | Up to 5 simultaneous gas measurements |
| Response Time | <25 s (t90 @ 60 L/h constant flow) |
| Repeatability | CH₄, CO, CO₂, O₂, and other supported gases |
| Enclosure Rating | Ex d IIC T6 Gb (certified per GB3836.1–2010 & GB3836.2–2010, NEPSI certified) |
| Operating Temperature | 5–45 °C |
| Inlet Flow Rate | 0.4–0.8 L/min (±0.02 L/min stability) |
| Power Supply | (198–242) V AC, 50/60 Hz, <125 W |
| Weight | ~50 kg |
| Dimensions | Not specified in input |
| Analog Output | 4–20 mA (2 mA fault signal), load: 250–350 Ω |
| Relay Outputs | 6 configurable dry-contact relays (1 A @ 250 V AC / 2 A resistive) |
| Gas Inlet | NPT 1/8″ female |
| Moisture Requirement | Non-condensing |
| Particulate Limit | ≤100 µg/m³, ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas Range | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |
| Ingress Protection | Not explicitly stated |
| Compliance | GB3836.1/2–2010, NEPSI-certified, suitable for Zone 1/21 hazardous areas |
| Brand | Schütz / SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SPGAS PORT mini |
| Price | Upon Request |
| Measurement Channels | 3 |
| Sensor Technologies | NDIR, Electrochemical (EC), and other modular principles |
| Display | 4.9" TFT LCD |
| Response Time (t₉₀) | <30 s @ 36 L/h stable flow |
| Sampling Flow Rate | 3 ± 0.5 L/min (integrated low-noise diaphragm pump) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | –20–60 °C |
| Battery Life | ≥8 h (fully charged, 25 °C) |
| Charging Time | ~5 h (5% to 90%, 25 °C) |
| Power Input | 100–260 VAC, 47–63 Hz |
| DC Output | 24 VDC, 0–6 A |
| Safety Certifications | UL 62368-1, CSA C22.2 No. 62368-1, TÜV EN 62368-1, CCC GB4943.1 |
| Preheat Time | ≤15 min (NDIR), ≤10 min (EC), cold start @25 °C |
| Ingress Protection | IP54 (enclosure) |
| Data Interface | RS232 (DB9-F), USB Type-A, optional Bluetooth 2.0 (2.4 GHz, ~10 m line-of-sight, BQB/FCC certified) |
| Data Export | FAT32-formatted USB flash drive (up to 16 GB) |
| Display Resolution | 0.1 g/m³ |
| Alarm Outputs | Relay & visual/audible alerts |
| Zero Calibration | One-button auto-zero, configurable auto-zero on power-up |
| Internal Filtration | Integrated particulate and hydrophobic protection filter |
| Gas Inlet | 1/8" NPT female |
| Sample Gas Requirements | 5–40 °C, non-condensing, particulates <100 µg/m³ (<1 µm), external filtration recommended for harsh environments |