| Brand | Laite |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | CX33-UVBGY-E |
| Excitation Source | LED (3W / 5W / 10W options) |
| Control Mode | Motorized |
| Fluorescence Filter Set | Integrated DAPI, GFP, FITC, Cy3, TRITC, mCherry, Cy5 filter cubes (user-selectable) |
| Instrument Type | Upright Fluorescence Microscope |
| Medical Device Classification | Non-medical device |
| Regulatory Status | Not FDA-cleared or CE-marked as medical equipment |
| Compliance | Designed for research-use-only (RUO) applications in life sciences |
| Brand | Laite |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-made) |
| Model | Ti-XLED-400 |
| Illumination Source | High-Power Fiber-Coupled LED |
| LED Power | 80 W |
| Excitation Modality | Epifluorescence via Spinning-Disk-Compatible Filter Cube Mount |
| Control Interface | Rotary Knob and Touchscreen Panel |
| Microscope Compatibility | Nikon ECLIPSE Ti2 Series Inverted Platforms |
| Instrument Class | Research-Grade Fluorescence Illumination Module |
| Medical Device Classification | Non-Medical Device |
| Fluorescence Architecture | Modular Fiber-Optic Coupled Light Engine |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 335 |
| Temperature Range | 0.3 K to 1505 K |
| Sensor Inputs | 2 standard (expandable to 4 with optional thermocouple card) |
| Control Outputs | 2 independent PID channels |
| Heater Power | 75 W total (configurable as 50 W + 25 W or 75 W + 1 W) |
| Interface | Ethernet, USB, IEEE-488 (GPIB) |
| Analog Output | ±10 V |
| Compliance | GLP/GMP-ready with audit-trail-capable logging via software |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 336 |
| Sensor Inputs | 4 (expandable to 8 with Scan Option) |
| Control Outputs | 4 (2 high-power, 2 low-power) |
| Max Heating Power | 150 W (100 W + 50 W) |
| Temperature Range | 0.3 K to 1505 K |
| PID Control | Digital, Auto-Tuning & Zone-Based |
| Supported Sensors | Diodes, RTDs (Pt100, Pt1000, Carbon-Glass, Cernox®, Rox™), Thermocouples (DT-470, DT-670, E, K, T, AuFe/Cr), Capacitance (with option card) |
| Interface | Ethernet, USB, IEEE-488 (GPIB) |
| Analog Output | ±10 V, 16-bit, 0.3 mV RMS noise |
| Display | 240 × 64 pixel graphical LCD |
| Compliance | GLP/GMP-ready architecture, supports audit trail via software logging |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 350 |
| Input Channels | 4 (expandable to 8 with Scan Option) |
| Sensor Compatibility | Cernox®, Rox™, DT-470, DT-670, PT-100/1000, carbon-glass, germanium, silicon diodes, thermocouples (with option cards), capacitive sensors |
| Measurement Range | 10 mK to 1000 K (sensor-dependent) |
| Excitation Current | As low as 10 nA for Cernox® |
| Noise Performance | Ultra-low-noise input circuitry optimized for ≤100 mK operation |
| Control Outputs | 4 independent PID-controlled outputs — Output 1: 75 W (25 Ω load), Output 2: 1 W (100 Ω load), Outputs 3 & 4: ±10 V analog (1 W max, 100 mA) |
| PID Auto-tuning | Per-loop, real-time adjustment |
| Current Reversal | Eliminates thermoelectric offset in resistive sensors |
| Compliance | CE certified |
| Interface | RS-232, USB, Ethernet (LXI-compliant) |
| Display | 240 × 64 pixel graphical LCD (8 × 40 characters), LED backlit |
| Data Logging | Local buffer + remote streaming at up to 10 Hz per active channel |
| Brand | Lambda |
|---|---|
| Origin | Switzerland |
| Model | MINIFOR |
| Price | €20,000 |
| Vessel Volume | 1–7 L |
| Aeration Flow Rate | 0–5 L/min (±0.1 L/min accuracy) |
| pH Control Resolution | 0.01 pH |
| Dissolved Oxygen Range | 0–10 mg O₂/L (±0.1 mg/L accuracy) |
| Temperature Control Range | 5–70 °C (±0.2 °C accuracy, 0–60 °C) |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Cryostat Microtome |
| Automation Level | Semi-Automatic |
| Section Thickness Range | 0–60 µm (with 0.5–5 µm incremental steps per range) |
| Specimen Vertical Travel | 50 mm |
| Specimen Horizontal Travel | 20 mm |
| Max Section Area | 55 × 45 mm |
| Specimen Orientation Adjustment | ±8° horizontal, ±8° vertical, 360° rotation |
| Knife Base Translation Range | ±25 mm front/back, ±25 mm left/right |
| Knife Angle Adjustment | 0–15° |
| Overall Dimensions | 500 × 480 × 280 mm |
| Compliance | Designed for GLP-compliant histopathology workflows |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Cryostat Microtome |
| Model | LD-4080 |
| Cooling System | Dual-Compressor with Five-Point Targeted Cooling |
| Operating Temperature Range | Cryohead: −50 °C, Cryostage: −45 °C, Cryoblade: −35 °C, Chamber: −25 °C ± 5 °C |
| Section Thickness Range | 0–100 µm (adjustable in 0.5 µm increments up to 6 µm |
| Minimum Graduation | 0.5 µm |
| Specimen Horizontal Travel | 25 mm |
| Specimen Vertical Travel | 60 mm |
| Trimming Range | 0–600 µm (10 µm increments) |
| Sectioning Angle Adjustment | ±10° |
| Sectioning Speed | Adjustable |
| Cryo-Positioning Stations | 12 |
| Power Supply | 220 V AC, 800 VA |
| Net Weight | 120 kg |
| Compliance | Designed for GLP-compliant histopathology workflows |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LD-4080 |
| Cutting Thickness Range | 0–100 µm (0.5 µm minimum increment) |
| Sample Horizontal Travel | 25 mm |
| Sample Vertical Travel | 60 mm |
| Sectioning Angle Adjustment | ±10° |
| Five-Point Refrigeration System (Cryotome Head | –50°C, Cryostage: –45°C, Cryoblade: –35°C, Chamber: –25°C ±5°C) |
| Rapid Cool-down | <10 min to operational cryo-state |
| Power Supply | 220 V, 800 VA |
| Net Weight | 120 kg |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LD-D100 Intelligent |
| Frequency | 23 kHz (adaptive) |
| Display | 7-inch medical-grade capacitive touchscreen |
| Temperature Monitoring | Real-time sample temperature sensing with visual display |
| Cooling Interface | External chiller port for precise thermal control |
| Safety | Auto-fault detection and audible/visual alarm system |
| Power Control | Adjustable ultrasonic power output |
| Timing Control | Programmable sonication time and duty cycle (on/off interval) |
| Brand | LANENDE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LD-GX02 |
| Optical Resolution | 4800 × 9600 dpi |
| Max Scanning Area (Reflective) | 355.6 mm × 215.9 mm |
| Min Pixel Size | 0.005 mm × 0.0026 mm |
| Scan Interface | USB 2.0 |
| Color Depth | 48-bit |
| Light Source | Dual Cold Cathode Fluorescent Lamp (CCFL) |
| Supported Formats | TIFF, JPEG |
| Software Features | Topological Analysis, Fractal Dimension (Box-Counting), Root Angle Quantification (Gravitropic & Horizontal), Color-Based Segmentation, Interactive Editing (Split/Merge/Reconnect), Cloud Data Sync, Dual-Language UI (English/Chinese), FDA 21 CFR Part 11–Ready Audit Trail |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Model | CSTHZ-82 |
| Timer Range | 1–120 min |
| Oscillation Frequency | 30–300 rpm (orbital) |
| Oscillation Amplitude | 26 mm |
| Temperature Control Range | RT to 90 °C |
| Temperature Accuracy | ±0.5 °C |
| Ultrasonic Frequency | 40–80 kHz (dual-frequency, adjustable) |
| Ultrasonic Power | 800 W |
| Ultrasonic Timer | up to 9999 min or continuous mode |
| Bath Volume | 52 L (560 × 495 × 190 mm) |
| Tray Dimensions | 420 × 350 mm |
| Cooling Function | Yes |
| Heating Power | 1.8 kW |
| Input Voltage | AC 220 V, 50 Hz |
| Number of Platforms | 1 |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DHG-1600A |
| Price Range | USD 70,000 – 140,000 |
| Channels | 36 (standard), up to 72 or custom-configurable |
| Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±0.5 °C |
| Airflow Control Range | 0.01–10 L/min |
| Airflow Accuracy | ±1.0 % FS |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2 % (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25 % |
| O₂ Detection Accuracy | ±1 % FS |
| Pressure Range | 0–200 kPa |
| Pressure Accuracy | ±1 % FS |
| Reaction Vessel Volume | 3.5 L per chamber |
| Total Chambers | 18 |
| Power Supply | 220 V AC, 50 Hz, 3000 W |
| Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Compliance | GB/T 19277.1–2011, GB/T 19277.2–2013, GB/T 22047–2008, ISO 14855-1:2012, ISO 14855-2:2018, ISO 17556:2012, ASTM D5338, EN 13432, GB/T 20197–2016 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DHG-1600C |
| Price Range | USD 70,000 – 140,000 |
| Channel Capacity | 36 or 72 (customizable) |
| Temperature Range | Ambient to 100 °C (±1 °C accuracy) |
| Humidity Control | Up to 90 % RH |
| Airflow Control | 0.01–100 mL/min |
| Reaction Vessel Volume | 2.3 L (borosilicate glass) |
| CO₂ Quantification Method | NaOH absorption followed by titration or Total Inorganic Carbon (TIC) analysis |
| Power Supply | 220 V AC, 50/60 Hz, 5000 W |
| Weight | 230 kg |
| Compliance Standards | GB/T 19277.1–2011, GB/T 19277.2–2013, GB/T 20197–2016, GB/T 22047–2008, ISO 14855-1:2012, ISO 14855-2:2018, ISO 17556:2012, ASTM D5338, EN 13432 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water Bath Constant-Temperature Shaker |
| Model | DKZ-3 |
| Timing Range | 1–999 min |
| Oscillation Frequency | 40–150 rpm |
| Amplitude | 30 mm (orbital) |
| Temperature Range | RT + 5 °C to 100 °C |
| Temperature Uniformity | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Chamber Material | Stainless Steel (304) |
| Chamber Dimensions (W×D×H) | 618 × 310 × 250 mm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1650 W |
| Number of Platforms | 1 |
| Display | Digital LED for temperature and speed |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FZ-12 |
| Instrument Type | Tumbling Shaker |
| Timer Range | 0–59 h 59 min |
| Rotational Speed Range | 0–60 rpm (no-load) |
| Temperature Range | Ambient to 60 °C |
| Platform Quantity | 1 |
| Sample Capacity | Compatible with 2 L containers (glass, PE, PTFE, and other chemically resistant vessels) |
| Construction | Stainless steel chamber with electrostatic powder-coated exterior |
| Safety Features | Overload protection circuit |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | HZQ-311C |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0.1 h to 999 h 59 min |
| Oscillation Frequency | 30–250 rpm |
| Orbit Diameter | 20 mm |
| Temperature Range | 4–60 °C |
| Number of Shaking Platforms | 1 |
| Platform Dimensions | 920 × 500 mm |
| Power Input | 1700 W |
| Display | Large Backlit LCD with Menu-Driven Interface |
| Construction | Stainless Steel Interior & Shaking Surface |
| Insulation | CFC-Free Polyurethane Foam |
| Safety Features | Independent Over-Temperature Cut-Off, Door-Interlocked Shutdown, Brushless AC Motor, Programmable Multi-Stage Control (Optional), RS-485/USB Data Export (Optional) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Temperature-Controlled Orbital Shaker |
| Model | KBC-82A |
| Timer Range | 1–999 h |
| Oscillation Speed | 30–300 rpm |
| Orbit Diameter | 30 mm |
| Temperature Range | Ambient to 60 °C |
| Platform Quantity | 1 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LB-2102 |
| Timer Range | 0–999 h |
| Oscillation Frequency | 40–280 rpm |
| Orbit Diameter | 50 mm |
| Temperature Range | 4–60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Stability | ±0.5 °C |
| Tray Dimensions | 750 × 500 mm |
| Number of Trays | 2 |
| Max Capacity | 70 × 250 mL or 50 × 500 mL or 24 × 1000 mL |
| Drive Type | Brushless DC Motor |
| Control System | Microprocessor-based with Programmable Multi-Stage Profile (up to 10 segments) |
| Safety Features | Independent Over-Temperature Cut-off, Door Interlock Switch, Motor Overheat Protection, Power-Fail Recovery, Soft-Start Acceleration |
| Optional | Humidity Control Module, USB Data Logging Interface, Stainless Steel Mirror-Finish Interior, Tempered Glass Viewing Window, Inert Gas Inlet Port |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP-8A |
| Instrument Type | Horizontal Oscillating Shaker |
| Timer Range | 1–999 min |
| Oscillation Speed | 0–200 rpm |
| Stroke Amplitude | 40 mm |
| Number of Platforms | 1 |
| Maximum Bottle Capacity | 16 × 2000 mL |
| Power Consumption | 120 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Compliance | HJ 557–2009 (China Environmental Protection Standard for Solid Waste Leaching Toxicity – Horizontal Oscillation Method) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | TCLB-20 |
| Type | Inversion Shaker |
| Timer Range | 1–999 h |
| Oscillation Speed | 0–60 rpm |
| Oscillation Amplitude | 180° (inversion motion) |
| Temperature Range | Ambient +5°C to 50°C |
| Shelf Quantity | 1 stainless-steel platform |
| Sample Capacity | Up to six 2 L containers (glass, PE, PTFE, or HDPE) |
| Construction | Stainless steel outer chamber with electrostatic epoxy coating |
| Safety Features | Overload protection circuit |
| Control System | Digital PID temperature controller + microprocessor-based speed regulator |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | TCLB-6A |
| Instrument Type | Inverting Shaker |
| Temperature Range | Ambient +5°C to 60°C |
| Timer Range | 0–999 h |
| Speed Range | 0–45 rpm (no-load), 30 ±2 rpm (loaded, 2 L bottles) |
| Number of Shaking Plates | 2 |
| Chamber Material | Stainless steel housing with electrostatic powder coating |
| internal fixtures | aluminum alloy |
| Safety Features | Overload protection |
| Compatible Vessels | 2 L glass, PE, PTFE, and ZHE containers |
| Compliance | Designed for GLP-compliant laboratory workflows requiring traceable, repeatable sample inversion under controlled thermal conditions |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator |
| Oxygen Concentration Range | 0–20% (adjustable) |
| Temperature Control Range | Ambient +5°C to 50°C |
| Temperature Uniformity & Stability | ±1°C |
| Humidity Capability | Compatible with ambient humidity ≤75% RH |
| Gas Supply | Nitrogen (N₂) |
| Chamber Dimensions (W×D×H) | 820 × 550 × 660 mm |
| Internal Volume | Approx. 297 L |
| Deoxygenation Method | Catalytic Oxygen Removal + Vacuum/Flush Protocol |
| Safety Features | Over-Temperature Cut-Off, UV Sterilization Lamp, Locked Gas Valves, Dual-Glove Access |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator |
| Temperature Control Range | Ambient +3°C to 60°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ≤±0.1°C |
| Anaerobic Chamber Volume | 820 × 550 × 660 mm (L×W×H) |
| Oxygen Concentration Range | 0–20% (adjustable, <1% typical operational setpoint) |
| Anaerobiosis Establishment Time | ≤5 min (sample chamber), ≤60 min (main culture chamber) |
| Anaerobic Hold Time | ≥12 h without gas replenishment |
| Gas Supply | Nitrogen (N₂) or N₂/CO₂/H₂ mixed gas (user-provided) |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1500 W |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | YY-82A |
| Instrument Type | General-Purpose Temperature-Controlled Orbital Shaker |
| Timer Range | 1–120 min |
| Oscillation Speed | 0–280 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient +5°C to 300°C |
| Heating Medium | Thermal Oil |
| Temperature Control | Digital PID |
| Temperature Accuracy | ±5°C |
| Chamber Material | Stainless Steel (Interior), Powder-Coated Steel (Exterior) |
| Platform | Single Deck |
| Packaging | Reinforced Wooden Crate |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-2112 |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 1–999 h |
| Oscillation Frequency | 30–280 rpm |
| Amplitude | 30 mm (horizontal circular) |
| Temperature Range | 5–60 °C |
| Shelf Quantity | 2 |
| Tray Dimensions | 800 × 500 mm |
| External Dimensions (per shelf) | 1280 × 770 × 1500 mm |
| Height Occupancy (stacked) | 1930 mm |
| Heating Power | 500 W (per shelf) |
| Cooling Power | 280 W (per shelf) |
| Refrigeration System | Imported compressor with R134a refrigerant |
| Control System | Microprocessor-based LED display with membrane keypad |
| Safety Features | Overheat protection, low-temperature cutoff, leakage current protection, door-open auto-stop, parameter encryption, and real-time alarm prompts for abnormal conditions |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-2112B |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0–500 h |
| Oscillation Frequency | 30–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 25 mm |
| Temperature Control Range | Ambient +5°C to 60°C |
| Temperature Resolution | ±0.1°C |
| Temperature Uniformity | ≤±1°C (at 25°C) |
| Temperature Stability | ≤±0.5°C (at 37°C) |
| Shelf Quantity | 2 |
| Shelf Dimensions | 970 × 560 mm |
| Chamber Volume | 582 L |
| Internal Dimensions | 1095 × 625 × 850 mm |
| External Dimensions | 1200 × 820 × 1600 mm |
| Net Weight | 425 kg |
| Power Consumption | 1150 W |
| Input Voltage | AC 220 V, 50/60 Hz |
| Maximum Load Capacity | 100 mL × 164 |
| Standard Configuration | 250 mL × 45 & 500 mL × 35 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-211C |
| Instrument Type | Full-temperature orbital shaker |
| Timer Range | 999 h |
| Oscillation Frequency | 40–280 rpm |
| Oscillation Amplitude | 26 mm (Φ) |
| Temperature Control Range | 4–60 °C |
| Humidity Control Range | 50–95 %RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±1 %RH |
| Temperature Accuracy | ≤±0.1 °C |
| Humidity Accuracy | ±3 %RH |
| Frequency Accuracy | ±1 rpm |
| Shelving | 1 stainless steel polished platform (970 × 480 mm) |
| External Dimensions (W×D×H) | 1260 × 830 × 1010 mm |
| Net Weight | 230 kg |
| Cooling System | Air-cooled, R134a refrigerant, frost-free operation |
| Humidification | External high-efficiency humidifier |
| Drive Mechanism | Brushless AC motor, constant-torque, wide-speed-range |
| Control Algorithm | PID with environmental scanning microprocessor |
| Display | Backlit LCD with real-time parameter monitoring |
| Interface | RS-232 port for data export |
| Safety Protections | Independent over-temperature cutoff, over-speed cutoff, leakage current protection, circuit breaker, compressor overload protection, low-water-level alarm, sensor fault detection, power-fail recovery, auto-restart after outage |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water Bath Constant-Temperature Shaker / Platform Shaker |
| Timer Range | 1–999 h |
| Oscillation Frequency | 0–280 rpm |
| Oscillation Amplitude | 200 mm |
| Temperature Control Range | Ambient +5°C to 100°C |
| Number of Platforms | 1 |
| Operating Mode | Reciprocating Motion |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZW-1000 |
| Temperature Range | 0–50 °C |
| Chamber Volume | 1000 L |
| Internal Dimensions (W×D×H) | 1000×1000×1000 mm |
| Light Source | LED cold-light panels |
| Illuminance Range | 0–12,000 lx |
| Illumination Layers | 4 |
| Temperature Uniformity | ±1.0 °C (±1.5 °C below 0 °C) |
| Humidity Range | 50–95 %RH |
| Humidity Uniformity | ±5 %RH |
| Light Intensity Control | 0–100 % of E<sub>max</sub>, stepless dimming |
| Airflow Pattern | Near-horizontal |
| Air Velocity | 0.1–0.3 m/s |
| Compressor Operation Mode | Intermittent |
| LED Panel Lifespan | 10,000 h |
| Continuous Operation Capability | 24/7, year-round |