Measurement Instruments
Filter
Showing 601–630 of 2711 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dektak XTL |
| Price Range | USD 95,000 – 135,000 (FOB Hamburg) |
| Measurement Principle | Capacitive Transduction |
| Measurement Capability | 2D Surface Profiling (Optional 3D Reconstruction) |
| Accuracy | ±0.5% of measured step height |
| Probe Tip Radius | 50 nm – 25 µm (interchangeable stylus options) |
| Normal Force Range | 0.3 – 15 mg (motorized force control) |
| Maximum Scan Length | 55 µm (standard) |
| Step Height Repeatability | 5 Å (1σ) on 1 µm step |
| Vertical Resolution | ≤1 Å (at full 6.55 µm vertical range) |
| Maximum Sample Size | Ø300 mm (flat wafers or rectangular substrates up to 300 × 300 mm) |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dektak XTL |
| Pricing | Available Upon Request |
| Measurement Principle | Capacitive Transduction |
| Measurement Capability | 2D Surface Topography (Optional 3D Reconstruction) |
| Accuracy | ±0.5% of measured step height |
| Probe Tip Radius | 50 nm – 25 µm |
| Normal Force Range | 0.3–15 mg |
| Maximum Scan Length | 55 µm |
| Step Height Repeatability | 5 Å (1σ, on 1 µm step) |
| Vertical Resolution | Up to 1 Å (within 6.55 µm vertical range) |
| Maximum Sample Size | 300 mm diameter |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NP Flex |
| Product Type | Non-Contact Profilometer / Surface Roughness Analyzer |
| Measurement Principle | White-Light Interferometry (WLI) |
| Maximum Measurement Volume | Up to 300° Angular Access |
| Vertical Resolution | Sub-nanometer |
| Field of View | Full-Area (2D/3D) Acquisition |
| Sample Compatibility | Large, Freeform, and Asymmetric Components |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | NPFLEX 3D |
| Product Type | Non-contact Profilometer / Surface Roughness Analyzer |
| Operating Principle | White-Light Interferometry |
| Vertical Resolution | Sub-nanometer |
| Measurement Mode | Full-field 3D Topography |
| Sample Flexibility | Large-format, Angled, and Complex-Geometry Samples |
| Optional Modules | Tilted Measurement Head, Through-Transmissive Media (TTM) Module, Folded-Objective Lens |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | NPFLEX-1000 |
| Measurement Principle | White Light Interferometry (WLI) |
| Type | Non-contact 3D Surface Profilometer / Roughness Analyzer |
| Sample Stage Travel | 300 mm X-Y |
| Design | Floor-standing Open-bridge Configuration |
| Software Platform | VisionXpress™ with Adaptive USI Mode and One-click Advanced Surface Find™ |
| Compliance | Designed for ISO 25178, ISO 4287, ASTM E1392, and USP <1058> analytical instrument qualification frameworks |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | I-300 Pro |
| Measurement Principle | Capacitive Absolute Pressure Sensing |
| Pressure Range | 1400–0 mbar (hPa) / 1050–0 Torr |
| Control Range | 1100–1 mbar (hPa) / 825–1 Torr |
| Pressure Accuracy | ±2 mbar |
| Vacuum Port | GL14 |
| Display | 7.0-inch TFT touchscreen |
| Power Supply | 30 VDC ±5% |
| Power Consumption | 10 W |
| Data Storage | 1 GB SD card (removable) |
| Enclosure Rating | IP21 |
| Certifications | CE, CSA |
| Dimensions (W×H×D) | 122 × 221 × 50 mm |
| Weight | 600 g |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | I-300 |
| Measurement Principle | Capacitive Absolute Pressure Sensing |
| Pressure Range | 1400–0 mbar (hPa) / 1050–0 Torr |
| Control Range | 1100–1 mbar (hPa) / 825–1 Torr |
| Pressure Accuracy | ±2 mbar |
| Vacuum Port | GL14 |
| Display | 4.3-inch TFT touchscreen |
| Power Supply | 30 VDC ±5% |
| Power Consumption | 3 W |
| IP Rating | IP21 |
| Certifications | CE, CSA |
| Dimensions (W×H×D) | 121 × 141 × 50 mm |
| Weight | 400 g |
| Brand | CAMECA |
|---|---|
| Origin | France |
| Model | IMS 7f-Auto, LEAP 5000 XR / XS / R |
| Type | Secondary Ion Mass Spectrometry (SIMS) and Laser/Field-Assisted Atom Probe Tomography (APT) Platforms |
| Compliance | ASTM E1527, ISO/IEC 17025, GLP/GMP-ready data audit trails, FDA 21 CFR Part 11–compliant software options |
| Sample Form | Bulk solids, thin films, epitaxial layers, semiconductors (Si, III-V, II-VI), metals, ceramics, glasses, insulators |
| Depth Resolution | <0.3 nm (SIMS) |
| Spatial Resolution | <0.3 nm (APT, 3D) |
| Detection Limit | Sub-ppq (SIMS) |
| Throughput | Fully automated multi-sample analysis chain |
| Reproducibility | RSD < 0.5% (SIMS depth profiling) |
| Key | Brand: Campbell |
|---|---|
| Origin | USA |
| Model | CR1000Xe |
| Operating Temperature (Standard) | -40 to +70°C |
| Operating Temperature (Extended) | -55 to +85°C |
| Analog Inputs | 16 single-ended or 8 differential, plus 2 dedicated 0–20 mA / 4–20 mA current inputs |
| ADC Resolution | 24-bit |
| Max Scan Rate | 100 Hz |
| Communication Interfaces | Ethernet, USB Micro-B, RS-232/RS-485/RS-422, CPI, CS I/O, SDI-12, I²C, SPI |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Power Input | 10–36 VDC |
| Real-Time Clock Accuracy | ±3 min/year (GPS optional for ±10 µs) |
| Enclosure | Anodized aluminum with RF-shielded stainless steel electronics housing |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Brand | Campbell |
|---|---|
| Origin | USA |
| Model | CR300 |
| CPU | ARM Cortex-M4 @ 144 MHz |
| Internal Memory | 80 MB data storage, 5 MB program storage, 2 MB OS storage |
| Clock Accuracy | ±1 minute/month |
| USB Interface | Micro-B, USB 2.0 Full-Speed (12 Mbps) |
| Power Input | 12 V terminal or 12 V battery/UPS |
| Excitation Output | 1 × switched 12 V (500 mA @ 20°C) |
| Analog Inputs | Differential, ±34 mV range, 230 nV resolution, accuracy ±(0.04% of reading ± 6 µV) at 0°–40°C |
| Operating Temperature | –40° to +70°C |
| Dimensions | 14 × 7.6 × 5.1 cm |
| Weight | 242 g |
| Communication Protocols | PPP, ICMP/Ping, Auto-IP (APIPA), IPv6, UDP, TCP, TLS, DHCP Client, SLAAC, DNS Client, Telnet, PakBus, SDI-12, Modbus RTU/ASCII/TCP, DNP3 |
| Environmental Protection | High-level surge and ESD protection |
| Data Transmission | Encrypted email & alarm notifications via TLS |
| Configuration | USB direct-to-PC |
| Compliance | Designed for long-term unattended field deployment in hydrological, meteorological, environmental, and industrial monitoring applications |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR1000X |
| Operating Temperature Range | –40 to +70 °C (standard), –55 to +85 °C (extended) |
| Analog Inputs | 16 single-ended or 8 differential |
| ADC Resolution | 24-bit |
| Max Scan Rate | 100 Hz |
| Communication Interfaces | Ethernet, USB Micro-B, RS-232/RS-485/RS-422, CPI, SDI-12, PakBus, Modbus TCP/RTU, DNP3, MQTT, NMEA 0183, I²C, SPI |
| Real-Time Clock Accuracy | ±3 min/year (±10 µs with optional GPS synchronization) |
| Power Supply | 10–18 VDC |
| Idle Current Draw | <1 mA @ 12 VDC |
| Dimensions | 23.8 × 10.1 × 6.2 cm |
| Weight | 0.86 kg |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR300 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Analog Inputs | 6 single-ended or 3 differential (software-configurable) |
| ADC Resolution | 24-bit |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Outputs | 2 (VX1, VX2) |
| Digital I/O | 7 configurable terminals (C1, C2, P_SW, SE1–SE4 |
| Communication Interfaces | USB Micro-B, RS-232, Ethernet (10/100BASE-T), PPP, RNDIS |
| Supported Protocols | PakBus, Modbus RTU/TCP, DNP3, SDI-12, TCP/IP, UDP, TLS v1.2, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, NTP, DHCP, DNS, ICMP, IPv4/IPv6 |
| Real-Time Clock Accuracy | ±1 minute per month (battery-backed) |
| Power Supply | 16–32 Vdc (CHG input) |
| Idle Current Draw | 1.5 mA @ 12 Vdc |
| Active Current Draw | 5 mA @ 12 Vdc (1 Hz scan, 1 analog measurement) |
| Enclosure Material | Powder-coated aluminum |
| Dimensions | 13.97 × 7.62 × 4.56 cm (5.5 × 3.0 × 1.8 in.) |
| Weight | 242–250 g (0.53–0.55 lb) |
| Onboard Memory | 80 MB flash (program/storage), 30 MB dedicated data storage |
| Programming Language | CRBasic (onboard BASIC-like language) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR3000 |
| Analog Input Channels | 28 single-ended (14 differential) |
| Analog Voltage Range | ±5000 mV |
| Analog Resolution | 0.33 µV |
| A/D Resolution | 16-bit |
| Maximum Scan Rate | 100 Hz |
| Pulse Count Channels | 4 |
| Switched Excitation Outputs | 4 voltage, 3 current |
| Control Ports | 3 SDM, 8 I/O |
| Communication Interfaces | CS I/O, RS-232, Ethernet (optional), RF radio (optional), CDMA/GPRS (optional), satellite (optional) |
| Supported Protocols | PakBus, Modbus RTU/ASCII/TCP, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTP, NTCIP, SDI-12, SDM |
| Memory | 4 MB internal |
| Power Consumption | 2 mA (sleep), 3 mA (1 Hz), 10 mA (100 Hz) |
| Environmental Compliance | CE, EMC, GDT input protection |
| Real-Time Clock | Temperature-compensated, battery-backed |
| Data Storage Format | Tabular (timestamp + record number) |
| Operating Temperature | 0–40 °C |
| Software Compatibility | LoggerNet 3.4/4.0, PC400 1.2, ShortCut 2.2 |
| Brand | CAMPBELL |
|---|---|
| Origin | USA |
| Model | CR310 |
| Operating Temperature | -40 to +70°C (standard, non-condensing) |
| Scan Rate | Up to 10 Hz |
| Analog Inputs | 6 single-ended or 3 differential (user-configurable) |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Outputs | 2 (VX1, VX2) |
| Communication Interfaces | USB Micro-B, RS-232, 10/100 Base-T Ethernet (RJ45) |
| Digital I/O | 7 configurable terminals (C1, C2, P_SW, SE1–SE4 |
| ADC Resolution | 24-bit |
| Analog Accuracy | ±(0.04% of reading + offset) at 0–40°C |
| Power Input | 16–32 Vdc (CHG), 10–18 Vdc (BAT) |
| Typical Idle Current | 10 mA @ 12 Vdc (Ethernet link idle) |
| Active Current | 56 mA @ 12 Vdc (Ethernet active, CPU always on) |
| Enclosure | Powder-coated aluminum |
| Dimensions | 16.26 × 7.62 × 5.68 cm (6.4 × 3.0 × 2.2 in.) |
| Weight | 288–306 g (0.64–0.68 lb) |
| Onboard Memory | 80 MB flash for OS/program, 30 MB for data storage |
| Protocols | PakBus, Modbus RTU/TCP, DNP3, SDI-12, TCP/IP, UDP, TLS 1.2, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, NTP, DHCP, SLAAC, ICMP, Telnet, PPP, RNDIS, Auto-IP |
| Real-Time Clock Accuracy | ±1 minute per month |
| Brand | CAMPBELL |
|---|---|
| Origin | USA |
| Model | CR350 |
| Operating Temperature | -40 to +70 °C (standard, non-condensing) |
| Max Scan Rate | 10 Hz |
| Enclosure Material | High-impact polycarbonate (Recycling Code 7) |
| Analog Inputs | 4 single-ended or 2 differential (software-configurable) |
| Pulse Counters | 8 (P_SW, P_LL, C1, C2, SE1–SE4) |
| Excitation Terminals | 2 (VX1, VX2) |
| Communication Interfaces | USB Type-C 2.0, RS-232, RS-485 |
| 12 V Switched Power Outputs | 2 |
| Digital I/O | 7 (C1, C2, P_SW, SE1–SE4 |
| Input Range | -100 to +2500 mV |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40 °C |
| ADC Resolution | 24-bit |
| Power Supply Input (CHG) | 16–32 Vdc (max 1.1 A for charger/solar input) |
| Real-Time Clock Accuracy | ±1 min/month |
| Supported IP Protocols | Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS v1.2, DNS, DHCP, SLAAC, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, MQTT(S) |
| Communication Protocols | PakBus, PakBus Encryption, Modbus RTU/ASCII/TCP, DNP3, SDI-12 |
| CPU & Program Memory | 50 MB serial flash |
| Data Storage | 50 MB serial flash |
| Idle Current Draw | 0.5 mA (@ 12 Vdc) |
| Active Current Draw | 8 mA (@ 12 Vdc, processor always on) |
| Dimensions | 16.3 × 8.4 × 5.6 cm (6.4 × 3.3 × 2.2 in.) |
| Weight | 288–306 g (0.64–0.68 lb), depending on comms options |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Processor | 32-bit ARM Cortex-M4 with hardware floating-point unit (100 MHz) |
| Internal Memory | 4 MB RAM, 6 MB flash for OS, 1 MB serial flash for program execution |
| MicroSD Card Support | Up to 16 GB |
| Real-Time Clock Accuracy | ±3 minutes/year (±10 µs with GPS synchronization) |
| USB Interface | USB 2.0 Full-Speed (12 Mbps), host/device capable |
| Ethernet | 10/100BASE-T |
| Communication Protocols | PakBus, SDI-12, SDM, RS-232, RS-485, CPI (Campbell Peripheral Interface) |
| U-Port Capabilities | Simultaneous analog/digital input, static vibration measurement (100 Hz – 6.5 kHz), bridge excitation (±2.5 V or ±2.5 mA), thermistor support (5 kΩ reference), frequency measurement up to 200 kHz |
| Analog Input | 12 single-ended or 6 differential channels |
| ranges | ±5000 mV, ±1000 mV, ±200 mV |
| Analog Output | 12-bit DAC (±2.5 V or ±2.5 mA) |
| Digital I/O | 12 configurable ports (3.3 V / 5 V logic) |
| Power Input | 12 V DC battery, solar (16–32 V DC), or USB |
| SW12V outputs | 2 × 12 V @ 1100 mA (20 °C) |
| Overvoltage Protection | All terminal strips include transient voltage suppression |
| Operating Temperature | −25 °C to +50 °C (extended range options available) |
| Dimensions | 20.3 × 10.2 × 6.1 cm |
| Weight | 0.42 kg |
| Compliance | CE, FCC Part 15 Class B, RoHS |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CR6 |
| Operating Temperature Range | -40 to +70°C (standard), -55 to +85°C (extended) |
| Analog Input Resolution | 24-bit ADC |
| Analog Voltage Accuracy | ±(0.04% of reading + offset) at 0–40°C |
| Input Channels | Up to 12 single-ended or 6 differential analog inputs |
| Communication Interfaces | Ethernet (10/100 RJ-45), USB Micro-B (virtual Ethernet & serial), RS-485, RS-422, SDI-12, CPI, CS I/O |
| Data Storage | 4 MB SRAM + 72 MB flash + microSD slot (up to 16 GB) |
| Power Supply | 10–18 Vdc (BAT), 16–32 Vdc (CHG) |
| Real-Time Clock Accuracy | ±3 min/year (GPS optional: ±10 µs) |
| Vibration Compensation | VSECT® spectral analysis for static vibrating-wire measurements |
| Enclosure | UV-stabilized TPE over impact-resistant polycarbonate (Recycling Code 7) |
| Dimensions | 21.0 × 10.2 × 5.6 cm |
| Weight | 0.42–0.52 kg |
| Brand | Campbell Scientific |
|---|---|
| Model | CR800 |
| Origin | USA |
| Differential Input Channels | 3 (6 single-ended) |
| Analog Input Resolution | 13-bit A/D |
| Scan Rate | Up to 100 Hz |
| Operating Temperature Range | 0 to 40 °C |
| Voltage Measurement Resolution | 0.33 µV |
| Sleep Mode Current Draw | ~0.6 mA |
| Active Current Draw (w/o RS-232) | 1–16 mA |
| Active Current Draw (w/ RS-232) | 17–28 mA |
| Communication Interfaces | 1 × CS I/O port, 1 × RS-232 serial port |
| Supported Protocols | PakBus®, Modbus RTU/ASCII, SDI-12, SDM, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP |
| Onboard Memory | 4 MB (data + program storage) |
| Data Format | Tabular ASCII |
| Operating System | PakBus OS |
| Compatible Software | LoggerNet, PC400, Short Cut |
| Optional Peripheral | CR1000KD handheld display |
| Brand | Campbell Scientific |
|---|---|
| Model | TM320 |
| Origin | USA |
| Temperature Range | −20 to 70 °C |
| Temperature Accuracy | ±0.5 °C |
| Relative Humidity Range | 0 to 95 %RH (non-condensing) |
| RH Accuracy | ±2 %RH |
| Operating Environment | −20 to 70 °C |
| Power Supply | 4 × AA alkaline batteries or optional AC adapter |
| Memory Capacity | 32,000 data points |
| Sampling Interval | Adjustable from 1 second to 24 hours (in 10-second increments) |
| Alarm Function | User-configurable high/low limits with audible alert |
| Housing Material | Polycarbonate |
| Dimensions | 10.2 × 7.7 × 3.9 cm |
| Weight | 255 g (9 oz) |
| Certifications | CE |
| Brand | Camtek |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Falcon 800 |
| Pricing | Available Upon Request |
| Brand | Camtek |
|---|---|
| Origin | Israel |
| Model | Falcon600 |
| Category | Precision Geometric Measurement Instrument / Profilometer |
| Application Scope | Semiconductor Wafer-Level and Advanced Packaging Inspection |
| Maximum Wafer Size | 300 mm (unmounted or framed) |
| Detection Capability | 2D & 3D Defect Detection and Metrology |
| Target Structures | Stacked Die, 3D IC, SiP, Flip-Chip, Fine-Pitch Wire Bonds |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cavitation Monitoring System |
| Price | Upon Request |
| Pressure Range | 0–100 bar |
| Pressure Hose Length | 3 ft |
| Gas Supply Hose Length | 6 ft |
| Minimum Sample Length | 4.25 in |
| Brand | Zhongjiao Jinyuan |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | CEL-GPPCH Custom Hydrogenation Reaction System |
| Pricing | Upon Request |
| Dimensions | 1410 mm × 730 mm × 1664 mm |
| Construction Material | ASTM A240 316L Stainless Steel |
| Reactor Temperature Range | 0–300 °C (precision oil-bath heating) |
| Vaporizer Temperature Range | 0–600 °C |
| Tubing Trace Heating Range | 0–200 °C |
| Maximum Operating Pressure | <10 MPa |
| Liquid Flow Rate | 0.1–5 mL/min |
| Catalyst Bed Volume | <100 mL |
| Gas Flow Range (expandable channels) | 0–500 sccm per line |
| Analytical Balance Capacity | 0–15 kg (resolution: 0.1 g) |
| Safety Systems | Proportional pressure relief valve, rupture disc, independent overtemperature alarm at all thermal zones, interlocked shutdown logic |
| Brand | CEL-Jiaoguang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CEL-RCCN (monocrystalline) / CEL-RCCO (polycrystalline) |
| Calibration Traceability | NIM-traceable (National Institute of Metrology, China) |
| Certified Spectral Response Range | 400–1100 nm |
| Active Area | 20 mm × 20 mm |
| Mounting Base | Anodized Aluminum (70 mm × 70 mm × 20 mm) |
| Cover Window | Space-grade radiation-hardened glass with refractive-index-matched optical adhesive |
| Temperature Sensor | Calibrated Pt100 RTD (4-wire Kelvin connection) |
| Electrical Interface | Dual LEMO connectors (Isc/Voc + temperature) |
| STC Conditions | 1000 W/m², AM1.5G spectrum, 25 °C cell temperature |
| CV Value Uncertainty | ≤ ±0.5 % (k=2) |
| Short-Circuit Current Stability | ≤ ±0.5 % over 1,000 h under continuous illumination |
| Operating Temperature Range | 10–40 °C |
| Max Continuous Current | 200 mA |
| Efficiency (STC) | >16 % |
| Fill Factor (FF) | >0.70 |
| Isc Temp Coefficient α | typical −0.05 to −0.08 mA/°C |
| Voc Temp Coefficient β | typical −1.8 to −2.2 mV/°C |
| Brand | CEL (Zhongjiao Jin Yuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | CEL-NP2000-2 |
| Measurement Range | 0–2,000 mW/cm² |
| Spectral Range | 190 nm – 2.5 µm (uniform response), extendable to 11,000 nm with calibration correction |
| Resolution | 1 µW |
| Response Time | < 0.4 s |
| Thermal Drift | < ±1% FS over 10 min |
| Accuracy | ±5% |
| Detector Active Area | Ø10 mm (0.75 cm²) |
| Max Power Density Tolerance | 200 W/cm² |
| Auto-ranging | 4 ranges (2 mW / 20 mW / 200 mW / 2000 mW) |
| Output | Digital LCD + Analog (1–1999 mV) |
| Power Supply | Rechargeable Li-ion battery + AC adapter (220 V, 50 Hz) |
| Brand | CEL |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEL-NP2000-10 |
| Price | Upon Request |
| Wavelength Range | 190 nm – 11,000 nm |
| Power Density Range | 0–2,000 mW/cm² / 0–10,000 mW/cm² (auto-ranging) |
| Sensor Active Area | Ø20 mm (314 mm²) |
| Spectral Response | 0.19–2.5 µm (uniformity ±2.7%) |
| Max Continuous Irradiance | 200 W/cm² |
| Resolution | 1 µW |
| Response Time | <0.4 s |
| Thermal Drift | <±1% FS within 10 min |
| Uncertainty | ±5% |
| Analog Output | 1–1999 mV |
| Operating Environment | Standard optical lab, 25°C, ambient pressure, no direct airflow |
| Power Supply | Rechargeable Li-ion battery + 220 V / 50 Hz charger |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model Variants | CEL-NP2000-2A (2 W Full Scale), CEL-NP2000-10A (10 W Full Scale) |
| Power Range | 0–2000 mW / 0–10000 mW |
| Detector Aperture | Ø10 mm / Ø20 mm |
| Spectral Range | 190 nm – 11,000 nm (UV-VIS-IR) |
| Temperature Compensation | 15–45 °C, Drift < ±1% FS |
| Resolution | 1 µW |
| Response Time | < 0.4 s |
| Accuracy | ±5% FS |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Built-in TF card logging |
| Power Supply | Internal 3000 mAh Li-ion battery (AC adapter: 220 V, 50 Hz) |
| Output Units | mW, mW/cm² |
| Brand | CEAJIN (Zhongjiaojinyuan) |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CEL-NPRC |
| Price | Upon Request |
| Brand | CEL (Zhongjiao Jinyuan) |
|---|---|
| Model | CEL-RCCN (monocrystalline), CEL-RCCO (polycrystalline) |
| Active Area | 20 mm × 20 mm |
| Spectral Response Range | 400–1100 nm |
| Calibration Irradiance | 1000 W/m² (AM1.5G) |
| Calibration Temperature | 25 °C ± 0.1 °C |
| Temperature Sensor | Calibrated Pt100 RTD (4-wire Kelvin connection) |
| Window Material | Space-grade radiation-hardened glass with refractive-index-matched optical adhesive |
| Enclosure Dimensions | 70 mm × 70 mm × 20 mm (aluminum baseplate) |
| CV Value Unit | A/(W·m⁻²) |
| Short-Circuit Current Temperature Coefficient α | typical –0.05 to –0.07 mA/°C |
| Open-Circuit Voltage Temperature Coefficient β | typical –2.0 to –2.5 mV/°C |
| Max Operating Current | 200 mA |
| Operating Temperature Range | 10–40 °C |
| Stability | Short-circuit current drift ≤ ±0.5% over 1,000 h under continuous illumination |
| Efficiency (STC) | ≥16% (monocrystalline), ≥15.2% (polycrystalline) |
| Fill Factor (FF) | ≥0.70 |
| Traceability | NIST-traceable calibration per ISO/IEC 17025-accredited laboratory |
| Certification | Individual test report with expanded uncertainty (k=2), full metrological traceability statement, and compliance documentation for IEC 60904-2, IEC 60904-3, and ASTM E1021 |
| Brand | Cellix |
|---|---|
| Origin | Ireland |
| Model | FS-1.5 / FS-7.0 / FS-80.0 / FS-1000 |
| Flow Ranges | ±1.5 µL/min |
| Accuracy | ±0.5% FS (FS-1.5) to ±0.2% FS (FS-1000), or ±5–10% of reading |
| Dead Volume | 1.0 µL |
| Max Operating Pressure | 200 bar |
| Dimensions | 60 × 51 × 21 mm |
| Weight | <0.1 kg |