Measurement Instruments
Filter
Showing 691–720 of 2715 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BF-2008 |
| Product Type | Ultrasonic Gas Flowmeter |
| Flow Range | 0.08–4 Nm³/h |
| Accuracy Class | ±1.5% of reading |
| Transitional Flow (Qt) | 0.4 Nm³/h |
| Overload Capacity | 4.8 Nm³/h |
| Max Operating Pressure | 20 kPa |
| Connection Thread | M30×2.0 |
| Operating Temperature | −10 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Explosion Protection Rating | Ex ib IIB T3 Gb |
| Power Supply | 3 × AA alkaline batteries (typical 1-year service life) |
| Display | Backlit LCD |
| IP Rating | IP65 (body), IP67 (sensor housing) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-7900PR |
| Product Type | Ultrasonic |
| Measurement Principle | Time-of-Flight (TOF) Ultrasonic Transit-Time Difference |
| Accuracy | ≤ ±2% F.S. |
| Velocity Range | 0–40 m/s |
| Minimum Detectable Velocity | 0.1 m/s |
| Pipe Diameter Compatibility | ≥ 0.5 m |
| Flue Gas Temperature Range | −20 to 190 °C |
| Flue Gas Pressure Range | −10 to +10 kPa |
| Host Operating Temperature | −20 to +60 °C |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Output Signal | RS-485 |
| Ingress Protection | IP65 |
| Material Contacting Gas | Corrosion-Resistant Alloy (e.g., Hastelloy C-276 or equivalent) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | UFM-7200-DN Series |
| Measurement Principle | Ultrasonic Time-of-Flight (Time Difference Method) |
| 声道 Number | 2–4 (model-dependent) |
| Accuracy Class | Class 1.0 (per ISO 6976 / OIML R137) |
| Flow Range | 2.5–4000 m³/h (DN50–DN300) |
| Minimum Start-up Flow | ≤0.5% Qₘᵢₙ |
| Operating Pressure | ≤0.6 MPa |
| Max. Working Pressure | ≤1.6 MPa |
| Fluid Medium | Single-phase gases (natural gas, LPG, air) |
| Temp. Range (Fluid) | –20 to +60 °C |
| Ambient Temp. | –25 to +55 °C |
| Power Supply | 24 VDC external + 3.6 V Li-SOCl₂ battery backup |
| Output Signals | RS-485, 4–20 mA, Modbus RTU, GPRS |
| Display | Backlit LCD showing standard cumulative flow, std. instantaneous flow, actual flow, temperature, pressure, battery status |
| Connection | Flanged (PN16, EN 1092-1) |
| Housing Material | Carbon steel |
| Transducer Material | Titanium alloy |
| Enclosure Rating | IP68 |
| Compliance | Meets requirements for custody transfer in urban gas distribution per CJJ/T 262–2017 and GB/T 32201–2015 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | USM-G2.5 / USM-G4 |
| Product Type | Ultrasonic Gas Flowmeter |
| Measurement Principle | Transit-Time Ultrasonic Method with L-Shaped Flow Path |
| Accuracy Class | Class 1.5 (EN 1359 / OIML R137 compliant) |
| Flow Range | USM-G2.5: 0.025–4 m³/h |
| USM-G4 | 0.04–6 m³/h |
| Interface | Threaded (M30) |
| Dimensions (L×W×H) | 232 × 172 × 135 mm |
| Weight | 1.6 kg |
| Power Supply | ER34615 Lithium Battery, 3.6 V |
| Operating Temperature | −10 °C to +40 °C |
| Storage Temperature | −20 °C to +60 °C |
| Operating Pressure | 0–20 kPa (gauge) |
| Temperature Compensation | Integrated Pt1000 sensor |
| Ingress Protection | IP65 |
| Explosion Protection | Ex ib IIB T3 Gb |
| Measurement Uncertainty | ±3% at Qmin ≤ Q < Qt |
| Core Components | Domestically developed ultrasonic transducers, ASIC-based signal processing unit, and firmware with embedded thermal drift compensation algorithm |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NOx/O₂ Dual-Gas Sensor |
| Voltage Range | 16–36 V DC |
| O₂ Measurement Range | 0–21% vol |
| NOx Measurement Range | 0–1500 ppm (NO + NO₂, λ > 1, NH₃-free environment) |
| NOx Accuracy | ±10 ppm (for [NOx] < 100 ppm) |
| Response Time (T₃₃–₆₆%) | NOx: 1200 ms (new generation), 1300 ms (legacy) |
| O₂ | 1000 ms (new), 1100 ms (legacy) |
| Fast Transient Response (T₁₀–₉₀%) | NOx: 100 ms |
| O₂ | 80 ms |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturing Type | OEM Sensor Component |
| Product Type | NOx Sensing Chip (HTCC-Based Electrochemical Platform) |
| Model | NOx Sensor Chip |
| Operating Principle | Potentiometric/Electrochemical Current Measurement |
| Measurement Range | 0–3076 ppm NOx |
| Operating Temperature | −40 °C to 1000 °C (exhaust-side) |
| Ambient Temperature Rating | −40 °C to 105 °C |
| Supply Voltage | 12 V / 24 V DC |
| CAN Interface | ISO 11898-2 compliant, 250 kbps baud rate |
| CAN Message Interval | 50 ms |
| Heater Power Consumption | Low-power integrated HTCC heater |
| Structural Design | Compact, high-vibration-resistant dual protective cap |
| Lifetime | Extended operational lifespan under cyclic thermal stress |
| Compliance | Designed for alignment with Euro VI, China VI, and EPA Tier 4 emission regulation monitoring requirements |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Oxygen Sensor Chip |
| Measurement Range | 0.98–1.02 (λ unit) |
| Operating Temperature | −40 °C to 1000 °C |
| Ambient Temperature Range | −40 °C to 105 °C |
| Supply Voltage | 12 V DC |
| Startup Time | ≤15 s to operational temperature (vs. >30 s for conventional thimble-type) |
| Heater Power Consumption | <12 W (typical at cold start) |
| Sensor Architecture | Multilayer ceramic planar element with integrated micro-heater and dual protective guard tubes |
| Aging Resistance | <±0.005 λ drift after 100,000 km simulated exhaust exposure (ISO 22738-compliant test cycle) |
| Poisoning Resistance | Validated against Pb, Si, P, and oil ash contaminants per SAE J1679 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PM1009 |
| Pricing | Available Upon Request |
| Detection Principle | Optical Transmission (Opposed-Beam) |
| Warm-up Time | 1 s |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Storage Temperature | −20 °C to +80 °C |
| Supply Voltage | DC 5.0 V ± 0.25 V (Ripple < 50 mV) |
| Operating Current | < 60 mA |
| Output Signal | PWM (3.3 V logic level) |
| Response Time | < 200 ms |
| Dimensions (PCBA only) | 43 mm × 25 mm × 5 mm (W × H × D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBH |
| Price | USD 340 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range Options | 0–2% vol, 0–5% vol, 0–75% vol |
| Accuracy | ≤ ±0.06% vol (0.00–1.00% vol) |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Explosion Protection Rating | Ex ia II C T4 Ga |
| Output Interface | Dual-mode — analog (0–5 V / 4–20 mA) and digital (UART TTL/RS485) |
| Housing Material | Full-metal hermetic enclosure |
| Optical Design | Dual-beam NDIR with reference & measurement channels |
| Temperature Compensation | Full-range automatic compensation |
| Dimensions | Φ20 × 19 mm or Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBrH |
| Price | USD 295 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5% vol CH₃Br |
| Accuracy | ±0.06% vol (0–1% vol), ±6% of reading (1–5% vol) @ 25°C ±2°C, 101.3 kPa |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Explosion Protection | Exia II C T4 Ga |
| Output Options | Analog (0–5 V / 4–20 mA) and Digital (UART TTL/RS485) |
| Housing | All-metal, dual-beam optical architecture |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SJH |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5% vol and 0–100% vol |
| Accuracy | ≤±0.06% vol (0.00–1.00% vol) |
| Operating Temperature | −40°C to +70°C |
| Storage Temperature | −40°C to +70°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Explosion Protection Rating | Ex ia II C T4 Ga |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Output Options | Analog (4–20 mA / 0–5 V) and Digital (UART TTL/RS485) |
| Housing Material | Hermetically Sealed Metal Enclosure |
| Calibration | Full-Range Temperature Compensation |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SRH |
| Price | USD 250 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Ranges | 0–5000 ppm |
| Accuracy | ±25 ppm or ±10% of reading (for ppm ranges) |
| Operating Temperature | −20 °C to +55 °C |
| Storage Temperature | −40 °C to +70 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Explosion Protection | Exia II C T4 Ga |
| Output Options | Digital (UART TTL/RS485) and Analog (0–5 V / 4–20 mA) |
| Housing | All-metal, dual-beam optical architecture |
| Dimensions | Φ20 × 19 mm / Φ20 × 16.6 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | USM |
| Product Type | Ultrasonic Gas Flowmeter |
| Measurement Principle | Transit-Time Ultrasonic Flow Measurement |
| Accuracy Class | 1.5 |
| Operating Pressure Range | 0–50 kPa |
| Operating Temperature | −10 °C to +40 °C |
| Storage Temperature | −20 °C to +60 °C |
| Explosion Protection | Ex ib IIB T3 Gb |
| Ingress Protection | IP54–IP65 |
| Power Supply | ER34615 Lithium Battery, 3.6 V |
| Flow Range (USM-G25) | 0.25–40 m³/h |
| Flow Range (USM-G40) | 0.4–65 m³/h |
| Flow Range (USM-G65) | 0.65–100 m³/h |
| Connection | Threaded (G2, G2½) |
| Dimensions (USM-G25/G40) | 330 × 244/248 × 167 mm |
| Weight | ~4 kg |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | USM Series |
| Pricing | Upon Request |
| Technology | Ultrasonic Time-of-Flight (TOF) |
| Measurement Principle | Ultrasonic Transit-Time Difference Method |
| Gas Medium | Natural Gas (NG), Liquefied Petroleum Gas (LPG) – vapor phase only |
| Accuracy Class | 1.5 |
| Flow Range (USM-G6/USM-G10/USM-G16) | 0.06–10 / 0.1–16 / 0.16–25 m³/h |
| Interface | G1½ threaded connection |
| Dimensions (L×W×H) | 246 × 204 × 110.5 mm |
| Weight | 2.3 kg |
| Battery | ER34615, 3.6 V |
| Operating Pressure | 0–30 kPa (gauge) |
| Operating Temperature | −10 °C to +40 °C |
| Storage Temperature | −20 °C to +60 °C |
| Ingress Protection | IP54 to IP65 |
| Explosion Protection | Ex ib IIB T3 Gb |
| Flow Error | ±3% (Qmin < Q < Qt), ±1.5% (Qt < Q < Qmax) |
| Integrated Sensors | Flow, Temperature, Pressure |
| Core Components | Domestically developed ultrasonic transducers and signal processing ASIC |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | USM-G2.5 / USM-G4 |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) |
| Flow Range (m³/h) | G2.5: 0.025–4.0 |
| G4 | 0.04–6.0 |
| Accuracy Class | 1.5 (±3% at Qmin ≤ Q < Qt |
| Operating Pressure | 0–20 kPa |
| Operating Temperature | −10 °C to +40 °C |
| Storage Temperature | −20 °C to +60 °C |
| Ingress Protection | IP54 (Aluminum Housing) / IP65 (Stainless Steel Housing) |
| Explosion Protection | Ex ib IIB T3 Gb |
| Power Supply | 3×AA alkaline or ER34615 (3.6 V) |
| Interface | Threaded connection — G1-1/4 or M30×2 (Aluminum) |
| Dimensions (L×W×H, mm) | Aluminum: 239×151×100 |
| Stainless Steel | 232×172×135 |
| Weight | 1.5 kg (Aluminum), 1.6 kg (Stainless Steel) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | USM-G2.5M / USM-G4M |
| Measurement Principle | Time-of-Flight (TOF) Ultrasonic Flow Measurement |
| Flow Range (m³/h) | 0.025–4 (USM-G2.5M) / 0.04–6 (USM-G4M) |
| Interface | UART/TTL |
| Dimensions (mm) | 164 × 44 × 50 |
| Temperature Sensing | Integrated |
| Pressure Sensing | Integrated |
| Accuracy Class | Class 1.5 (per EN 1434 / OIML R137) |
| Max. Working Pressure | 20 kPa |
| Operating Temp. | −10 °C to +40 °C |
| Storage Temp. | −20 °C to +60 °C |
| Power Consumption | <50 µA (standby, typical) |
| Flow Error | ±3% (Qmin ≤ Q < Qt), ±1.5% (Qt ≤ Q ≤ Qmax) |
| Compliance | Meets requirements for residential and small commercial gas metering under ISO 4064-1:2019, EN 1434-2018, and GB/T 6968–2019 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSU ADV Oxygen Sensor |
| Price | USD 47.20 (based on ¥330 at 1 USD = ¥7.0) |
| Detection Principle | Zirconia Solid Electrolyte (High-Temperature Nernst Principle) |
| Operating Voltage | DC 7.5 V |
| Supply Voltage Range | 10.8–16.5 V DC |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Thread Size | M18 × 1.5 |
| Heater Steady-State Power | 8.7 W |
| Nernst Cell Internal Resistance | 300 Ω |
| Measurement Accuracy (λ = 0.8) | Ip = −0.652 ± 0.032 mA |
| Measurement Accuracy (λ = 1.0) | Ip = −0.018 ± 0.008 mA |
| Measurement Accuracy (λ = 1.7) | Ip = 0.515 ± 0.022 mA |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS-AFR-01 |
| Operating Voltage | DC 9–12 V |
| Storage Temperature | −40 °C to 90 °C |
| Operating Exhaust Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18×1.5 |
| Heater Steady-State Power | 10 W |
| Measurement Accuracy (at λ = 1) | ±0.02 |
| Air–Fuel Ratio (AFR) Measurement Range | 0–2 (λ-equivalent) |
| Light-Off Time | < 15 s |
| Sensing Principle | Zirconia-based Solid Electrolyte (High-Temperature Nernst + Pump Cell Configuration) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ZS-ST-01 |
| Operating Principle | Zirconia Solid Electrolyte (Nernst Potential) |
| Supply Voltage | DC 12 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18×1.5 |
| Signal Output | Binary λ-switching voltage (≥750 mV at λ = 0.93–0.97 |
| Internal Resistance | ≤1 kΩ (at 150–930 °C) |
| Response Time (600 → 300 mV) | <150 ms |
| Response Time (300 → 600 mV) | <100 ms |
| Light-off Time | <15 s |
| Environmental Robustness | High tolerance to condensate, soot, and hydrocarbon fouling |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZS-ST-09 |
| Application | Two-Wheeler Exhaust Lambda Monitoring |
| Detection Principle | Zirconia-Based Potentiometric (Limit-Current Type) |
| Operating Voltage | DC 12 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Installation Thread | M12 × 1.25 |
| Signal Output Voltage (λ = 0.93–0.97) | ≥750 mV |
| Signal Output Voltage (λ = 1.05–1.10) | 50 ± 30 mV |
| Internal Resistance | ≤1 kΩ (at 850 °C: ≤0.5 kΩ) |
| Response Time (600 → 300 mV) | <150 ms |
| Response Time (300 → 600 mV) | <100 ms (at 850 °C: <60 ms) |
| Light-off Time | <15 s |
| Exhaust Moisture & Deposit Tolerance | High |
| Compliance | Designed for ISO 8767, SAE J167, and GB/T 20071-2022 (Motorcycle Emission Control Systems) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ZS-WB4.2-01 (LUS4.2) |
| Detection Principle | Zirconia Solid Electrolyte High-Temperature Nernst Principle |
| Operating Voltage | DC 9 V |
| Storage Temperature | −40 °C to 90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18 × 1.5 |
| Heater Steady-State Power | 10 W |
| Nernst Cell Internal Resistance | 80 Ω |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Lambda Accuracy | ±0.03 at λ = 0.8 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LSU4.9-based Wide-Range Oxygen Sensor |
| Pricing | Available Upon Request |
| Detection Principle | Zirconia Solid Electrolyte (High-Temperature Nernst Principle) |
| Operating Voltage | DC 7.5 V |
| Storage Temperature | −40 °C to +90 °C |
| Exhaust Gas Operating Temperature Range | 150 °C to 930 °C |
| Mounting Thread | M18 × 1.5 |
| Heater Steady-State Power | 7.5 W |
| Nernst Cell Internal Resistance | 300 Ω |
| Lambda (λ) Measurement Range | 0.65 to ∞ |
| Lambda Accuracy | ±0.03 at λ = 0.8 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | LSF XFOUR |
| Detection Principle | Zirconia Solid Electrolyte (Nernst Principle) |
| Operating Temperature Range | 150–930 °C |
| Storage Temperature | −40 to 90 °C |
| Exhaust Gas Temperature Rating | Up to 850 °C |
| Output Voltage (λ = 0.93–0.97) | 1005 ± 40 mV |
| Output Voltage (λ = 1.05–1.10) | 190 ± 30 mV |
| Internal Resistance | ≤2.5 kΩ (at cold start), ≤0.5 kΩ (at 850 °C) |
| Response Time (700 mV ↔ 400 mV) | <100 ms (cold), <80 ms (hot) |
| Light-off Time | <12 s |
| Thread Size | M18 × 1.5 |
| Heater Integrated | Yes |
| Reference Air Supply | Pumped (electrochemical oxygen pumping) |
| Sensor Type | Limiting-current / Concentration-cell (switch-type) lambda sensor |
| Core Substrate | HTCC (High-Temperature Co-fired Ceramic) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | CWH1350 |
| Price Range | USD 1–9,999 |
| Instrument Type | Portable |
| Temperature Range | −50°C to 1350°C |
| Basic Accuracy | ±2.0°C |
| Temperature Resolution | 0.1°C / 0.1°F |
| Emissivity Adjustment | 0.10–1.00 (adjustable in 0.01 increments) |
| Response Time | <150 ms |
| Laser Aiming | Single-point Class II diode laser (λ = 630–670 nm, output <1 mW) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 50:1 |
| Repeatability | ±0.5% of reading or ±1°C (±1.8°F) |
| Operating Temperature | −20°C to +50°C |
| Storage Temperature | −40°C to +60°C |
| Units | °C / °F selectable |
| Power Supply | 8.0–10.0 VDC |
| Current Consumption | ≤80 mA |
| Enclosure Rating | IP65 |
| Certification | Certified intrinsically safe per GB 3836.1–2010 and GB 3836.4–2010 (Explosion-proof Certificate No. attached to product documentation) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CWH600 |
| Price Range | USD 1–1,400 |
| Instrument Type | Portable |
| Temperature Range | −50 °C to 650 °C |
| Basic Accuracy | ±1.5 °C |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Emissivity Adjustment | 0.10–1.00 (step 0.01) |
| Response Time | <400 ms |
| Laser Aiming | Dual Class II Diode Lasers (λ = 630–670 nm, P<1 mW) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 12:1 |
| Repeatability | ±0.5% of reading or ±1 °C (±1.8 °F) |
| Operating Temperature | −10 °C to 50 °C |
| Storage Temperature | −20 °C to 60 °C |
| Display Units | °C / °F switchable |
| Power Supply | 8.0–10.0 V DC |
| Current Draw | ≤80 mA |
| Enclosure Rating | IP54 |
| Certification | MA Certified (China MSHA-equivalent), Ex ib I Mb Intrinsically Safe Mark, CNEX Test Report No. attached |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | cWH850 |
| Price Range | USD 1–1,400 |
| Instrument Type | Portable |
| Temperature Range | −50°C to 850°C |
| Accuracy | ±1.5°C |
| Temperature Resolution | 0.1°C / 0.1°F |
| Emissivity Adjustment | 0.10–1.00 (adjustable) |
| Response Time | <400 ms |
| Laser Aiming | Dual Class II laser (630–670 nm, <1 mW) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 16:1 |
| Repeatability | ±0.5% of reading or ±1°C (±1.8°F) |
| Operating Temperature | −10°C to +50°C |
| Storage Temperature | −20°C to +60°C |
| Display | Backlit LCD with °C/°F toggle |
| Power Supply | 8.0–10.0 VDC, ≤80 mA |
| IP Rating | IP54 |
| Dimensions | 160 × 82 × 41.5 mm |
| Weight | 180 g |
| Data Logging | Optional internal storage for up to 20 readings |
| Alarm Functions | High/Low temperature threshold alert (HAL/LAL) |
| Measurement Modes | Max/Min/DIF/AVG, Hold, Trigger Lock |
| Auto Power-Off | Yes |
| Laser On/Off Switch | Yes |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CY220 |
| Price Range | USD 550–680 |
| Instrument Type | General-Purpose Analytical Balance |
| Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ±0.001 g |
| Linearity | ±0.002 g |
| Pan Size | 128 × 128 mm |
| Stabilization Time | 2–3 s |
| Calibration | Automatic External Calibration |
| Weighing Units | g, mg, ct, oz, dwt, mom, GN |
| Tare Range | Full Capacity |
| Operating Temperature | 15–35 °C |
| Chamber Dimensions (W×D×H) | 210 × 300 × 145 mm |
| Net Weight | 4.1 kg |
| Power Supply | 230 V / 50 Hz |
| Compliance | GLP/GMP, ISO 9001 |
| Brand | D&A |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES-J120D |
| Instrument Type | Density-Specific Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Density Resolution | 0.0001 g/cm³ |
| Weighing Chamber Height | 210 mm |
| Pan Diameter | Φ90 mm |
| Operating Temperature Range | 13–25 °C |
| Operating Humidity Range | 20–85% RH (non-condensing) |
| Stabilization Time (Avg.) | ≤2.5 s |
| Warm-up Time | 30–60 min |
| Power Supply | 220 V AC / 50 Hz input |
| RS232 Baud Rates | 300, 600, 1200, 2400, 4800, 9600 |
| Construction | Stainless Steel Density Accessories |
| Compliance | Designed for GLP/GMP-aligned workflows, supports ASTM D792, ISO 1183, and USP <841> density determination protocols |
| Brand | D&A |
|---|---|
| Origin | Tianjin, China |
| Model | ES1035A |
| Max Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability | ±0.02 mg |
| Linearity | ±0.02 mg |
| Calibration | Automatic Internal Calibration |
| Stabilization Time | ≤2.5 s |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–80 %RH |
| Pan Diameter | Ø90 mm |
| Chamber Height | 230 mm |
| Display | Adjustable LCD (185 × 100 mm) |
| Interface | RS232 (300–9600 bps) |
| Power | 220 V AC / 50 Hz input |
| Accuracy Class | Class I (per OIML R76) |
| Brand | D&T |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP1204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability (5% load) | ±0.2 mg |
| Repeatability (near full load) | ±0.3 mg |
| Linearity Error | ±0.3 mg |
| Calibration Method | Internal (isoCAL) |
| Stabilization Time | ≤3 s |
| Pan Diameter | Φ90 mm |
| Dimensions (W×D×H) | 210 × 310 × 315 mm |
| Draft Shield Height | 210 mm |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Temperature Drift | ≤5 ppm/°C |
| Warm-up Time | <15 min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| DC Output | 12 VDC, 1 A |
| Communication Interface | RS232 (configurable baud rates: 300–9600) |
| Display | VA LCD |
| Environmental Compensation | Automatic temperature & time-triggered isoCAL |
| Shock Protection | Four-stage damping system |
| Accuracy Class | ISO 9001-compliant design |