Measurement Instruments
Filter
Showing 961–990 of 2728 results
| Brand | Hexagon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TubeInspect High-Precision High-Speed Optical Tubing Inspection System |
| Form Factor | Handheld |
| Camera Resolution (Standard) | 3 MP |
| Camera Resolution (HRC Version) | 12 MP |
| Interface | GigE Vision |
| Lighting | Integrated Adjustable LED |
| Reference System | Patented 3D Glass Reference Target |
| Software Platform | BendingStudio XT |
| Compliance Support | ISO 10360, VDI/VDE 2634 Part 2, ASTM E2925 (for optical CMM validation), GLP/GMP-ready audit trail via BendingStudio XT |
| Brand | Hexagon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | XPERT |
| Configuration | Bridge-Type |
| Operation Mode | Automatic |
| Instrument Orientation | Vertical |
| Measurement Method | Contact & Non-Contact Hybrid |
| Measurement Volume | 600 × 500 × 500 mm to 600 × 800 × 600 mm |
| Volumetric Accuracy | Starting from 0.5 µm |
| Standard Ambient Temperature | 19–21 °C |
| Minimum Air Supply Pressure | 0.6 MPa |
| Application Sectors | Mechanical Manufacturing, Automotive, Aerospace, Mold & Die, Electronics, Medical Devices |
| Brand | Hexi |
|---|---|
| Model | ES5000-6S |
| Max Capacity | 5000 g |
| Readability | 1 g |
| Repeatability | ±1 g |
| Linearity | ±1 g |
| Tare Range | 0–5000 g |
| Stabilization Time | 3 s |
| Sensitivity Drift | ±0.005 %/°C |
| Operating Temperature | 10–35 °C |
| Power Supply | AC 220 V, 50 Hz |
| Pan Dimensions | 168 × 128 mm |
| Overall Dimensions (L×W×H) | 795 × 320 × 90 mm |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Science Corporation |
| Product Type | Non-contact 3D Optical Profilometer / Surface Roughness Analyzer |
| Operating Principle | White-Light Interferometry |
| Model | VS1800 |
| Compliance | ISO 25178-2:2012, ISO 25178-601:2013, ISO 25178-602:2013 |
| Vertical Resolution | ≤ 0.01 nm (Phase-Shifting Mode) |
| Repeatability | < 0.1% (Z-height) |
| Field of View | Up to 6.4 mm × 6.4 mm (single-shot) |
| Measurement Speed | As fast as 5 seconds per acquisition (typical) |
| Optional Module | Large-Inclination Angle Measurement Kit |
| Brand | Huake Instrument |
|---|---|
| Model | HK-128W |
| Measurement Principle | Photometric (450 nm LED-based colorimetric assay) |
| Range | 0–100 µg/L |
| Display | 5.7″ 320×240 dot-matrix LCD with bilingual (Chinese/English) menu |
| Measurement Cycle | Programmable 5–60 min per channel |
| Accuracy | ±2% FS |
| Repeatability | ≤1% |
| Baseline Drift | Compensated via blank calibration |
| Sample Flow Rate | 150–300 mL/min |
| Sample Temp. Control | Up to 50 °C |
| Reagent Temp. Control | Up to 50 °C |
| Reagent Consumption | ≤5 L/30 days (cycle-dependent) |
| Output | 4–20 mA (isolated), RS485 standard, HART/Profibus optional |
| Power | AC 220 V ±10%, 50 Hz, max. 240 W |
| Dimensions | 450 × 690 × 225 mm (W×H×D) |
| Weight | 22 kg |
| Compliance | Designed for continuous operation in industrial process water monitoring environments |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | HK-228 |
| Price | Upon Request |
| Display | Chinese-language dot-matrix LCD |
| Measurement Range | 0–100 µg/L |
| Accuracy | ±2% F.S. |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% |
| Stability | ±1% F.S. / 4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Dimensions (L×W×H) | 420 × 190 × 280 mm |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz |
| Power Consumption | 30 W |
| Weight | 5 kg |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | LC-R Series (LC-R-2500 / LC-R-768 / LC-R-720 / LC-R-1080) |
| Modulation Type | Amplitude and Phase |
| Pixel Count | 1024×768 to 1920×1200 |
| Pixel Pitch | 8.1 µm to 19 µm |
| Aperture Ratio | 90–93% |
| Contrast Ratio | 1000:1 to 5000:1 (wavelength-dependent) |
| Phase Modulation Depth | >1π to >1.2π across visible spectrum (400–700 nm) |
| Frame Rate | 60 Hz to 180 Hz |
| Diffraction Efficiency | ≥60% |
| Spectral Range | 400–700 nm |
| Bit Depth | 8-bit |
| Interface | DVI, optional USB |
| Display Technology | Reflective LCoS microdisplay |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1 |
| Pixel Resolution | 1920 × 1080 |
| Pixel Pitch | 8 µm |
| Interface | USB (for gamma/dynamic range calibration), HDMI/DisplayPort (video input, green channel used for 8-bit phase addressing) |
| Phase Modulation | Pure-phase, software-defined |
| Wavelength Range | Multiple standard options (e.g., 400–450 nm, 532 nm, 633 nm, 785 nm, 1064 nm) |
| Operating Mode | Hot-pluggable, extended desktop display mode |
| Brand | Honeywell |
|---|---|
| Model | HPA |
| Origin | USA |
| Type | Barometric Altimeter |
| Pressure Range | 0–17.6 psia |
| Operating Temperature | −40 °C to +85 °C |
| Accuracy | ±0.03 psia or ±0.06% FSO |
| Long-Term Drift | ≤0.02% FSO/year |
| Output Interface | TTL-compatible digital output |
| Form Factor | Compact, low-mass package |
| Compliance | RoHS-compliant, designed for aerospace and industrial altitude referencing applications |
| Brand | Honeywell |
|---|---|
| Model | HPB |
| Measurement Range | 500–1200 hPa |
| Operating Temperature | −40 °C to +85 °C |
| Accuracy | ±0.4 hPa or ±0.8 hPa (typ.) |
| Long-Term Drift | ≤0.25 hPa/year |
| Output Interface | TTL-compatible digital output |
| Power Consumption | Low-power design |
| Form Factor | Compact and lightweight |
| Origin | USA |
| Supply Chain Status | Imported via authorized distributor |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PPT Series |
| Output Options | RS232 / RS485 Digital or 0–5 VDC Analog |
| Accuracy | ±0.05% FSO over –40 to +85 °C |
| EMC Protection | Enhanced EMI Shielding per EN 61326-1 |
| Certifications | CE Marked (EMC & LVD Directives) |
| Dual Outputs | Independent Pressure and Sensor Temperature Signals |
| Compliance | Meets EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission) |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | PPT-R |
| Certification | FM, CSA, CE |
| Operating Temperature Range | –40 °C to +85 °C |
| Accuracy | ±0.05% FS (Full Scale Output) |
| Output Options | 0–5 VDC analog output |
| Digital Interface | RS232 / RS485 compatible |
| Enclosure | Hermetically Sealed, Ruggedized Housing with Integrated Cable |
| Compliance | ATEX Zone 1/21, IECEx, UL 913 Class I Div 1, EN 60079-0/-11 |
| Brand | Hongtuo Technology |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZM-105B Portable Intelligent Electronic Soap Film Flowmeter |
| Price | USD 700 (FOB) |
| Liquid Mass Flow Accuracy | ΔQ < ±1% |
| Repeatability | < 0.5% |
| Flow Resolution | 0.1 mL/min |
| Time Resolution | 0.1 s (internal calculation to 0.01 s) |
| Measuring Range | 0.3–30,000 mL/min |
| Operating Temperature | 0–40 °C |
| Built-in Battery | 4.8 V / 700 mAh, >24 h standby, >500 charge cycles |
| External Power | 9 V DC input with integrated trickle charging |
| Dimensions | 90 × 150 × 280 mm |
| Weight | 1.3 kg |
| Brand | HORDE Electric |
|---|---|
| Model | HD-BSDPL |
| Measurement Principle | Continuous-wave (CW) Doppler radar at 24.000–24.250 GHz |
| Velocity Range | 0–30 m/s |
| Velocity Resolution | 0.001 m/s |
| Accuracy | ±1% of reading (for surface velocity) |
| Operating Distance | up to 30 m |
| Elevation Angle Compensation Range | 30°–70° |
| Azimuth & Pitch Auto-Correction | Enabled |
| Display | Color LCD with guided menu interface |
| Power Supply | Rechargeable Li-ion battery (DC 11.6 V), >10 h continuous operation |
| Operating Current | ≤120 mA @12 V (active), ≤1 mA @12 V (sleep) |
| Environmental Rating | IP65 (main unit), IP67 (radar sensor) |
| Operating Temperature | −40 °C to +60 °C |
| Output Options | RS485 (optional), 4–20 mA (optional), relay (optional), HART (optional), NB-IoT/GPRS/LoRa (optional) |
| Flow Computation | Manual water level input required |
| instantaneous flow range | 0–999,999,999 m³/h |
| cumulative flow range | 0–999,999,999 m³ |
| Brand | HORDE Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HD-DP601 |
| Unit Price | USD 1,200 (FOB) |
| Liquid Velocity Measurement Resolution | 0.001 mm/s |
| Liquid Level Range | 0–10 m |
| Flow Velocity Range | 0–5 m/s |
| Instantaneous Flow Rate Range | 0–999,999,999 m³/h |
| Cumulative Flow Range | 0–999,999,999 m³ |
| Temperature Range | −10 to +70 °C |
| Level Resolution | 0.001 m |
| Flow Rate Resolution | 0.1 m³/h |
| Temperature Resolution | 0.1 °C |
| Housing Material | PVC |
| Power Consumption | <2 W |
| Display | TFT Color LCD |
| Enclosure Rating | IP65 (Transmitter), IP68 (Sensor) |
| Supply Voltage | Transmitter: AC 220 V / DC 24 V / Solar-Charged Battery |
| Sensor | 9–24 V DC |
| Output Signals | RS-485 Modbus RTU (standard), 4–20 mA analog output (standard), optional HART / NB-IoT / LoRaWAN |
| Data Update Interval | 8 s (default) |
| Mounting | Wall-mounted transmitter, immersion-type sensor with adjustable bracket |
| Cable Length | 10 m standard (custom lengths available) |
| Cable Material | Polyurethane-coated corrosion-resistant cable |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-230 |
| Temperature Range | 0–300 °C |
| Output | Analog (4–20 mA / 0–10 V) |
| Alarm Outputs | Dual independent relay outputs |
| Mounting | Benchtop / Fixed-installation compatible |
| Compliance | CE-marked, RoHS-compliant |
| Enclosure Rating | IP65 (front panel) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-230 |
| Temperature Range | 0–300 °C |
| Output | Analog (4–20 mA or 0–10 V selectable) |
| Alarm Outputs | Dual independent relay outputs |
| Mounting | Benchtop / Fixed-installation compatible |
| Compliance | CE marked, RoHS compliant |
| Enclosure Rating | IP65 (front panel) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-540 |
| Temperature Range | –50 °C to 1000 °C |
| Measurement Time | 1–2 s |
| Spot Size (S-type) | Ø25 mm |
| Optical Resolution | High |
| Indication Method | Dual-Beam Laser Pointer |
| Mounting | Handheld / Optional Tripod Mount |
| Compliance | CE, RoHS, JIS C 1607-1 (Infrared Thermometers) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-540 |
| Temperature Range | –50 °C to 1000 °C |
| Measurement Accuracy | ±1.5 °C or ±1.5% of reading (whichever is greater) |
| Response Time | ≤2 s |
| Spot Size | Φ25 mm at specified working distance (S-type optics) |
| Optical Resolution (D | S): 50:1 |
| Spectral Response | 8–14 µm |
| Emissivity Adjustment | 0.10–1.00 (0.01 step) |
| Display Resolution | 0.1 °C/°F |
| Power Supply | 2 × AA batteries |
| Operating Environment | –10 °C to 50 °C, <85% RH non-condensing |
| Weight | 220 g |
| Dimensions | 170 × 110 × 45 mm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-540 |
| Temperature Range | –50 to 1000 °C |
| Measurement Principle | Dual-wavelength infrared radiometry |
| Response Time | ≤2 s |
| Spot Size (S-type) | Ø25 mm at specified working distance |
| Optical Resolution | High spatial resolution for small-area targeting |
| Indication Method | Dual-beam laser pointer system |
| Compliance | Designed per IEC 61215-2 (industrial thermometry), meets ISO 18434-1 guidelines for condition monitoring |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-550 |
| Measurement Range | −50 to 500 °C |
| Spectral Response | 8–16 µm |
| Distance-to-Spot Ratio | 15:1 (1 m → Ø24 mm) |
| Emissivity Adjustment Range | 0.10–1.00 (0.01 step) |
| Repeatability | ±0.5 °C or ±0.5 % of reading (whichever is greater) |
| Response Time (t₉₀) | ≤250 ms |
| Operating Ambient Temperature | 0 to 50 °C |
| IP Rating | IP54 (optional drip-proof housing available) |
| Output Interface | Analog 4–20 mA / 0–5 V DC + RS-485 Modbus RTU |
| Compliance | HACCP-aligned design, CE marked, RoHS compliant |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-550 |
| Measurement Range | −50 to 500 °C |
| Spectral Response | 8–16 µm |
| Distance-to-Spot Ratio | 50:1 |
| Spot Size at 1 m | Ø24 mm |
| Emissivity Adjustment Range | 0.10–1.00 (adjustable in 0.01 steps) |
| Response Time | ≤2 s |
| Output Interface | Optional RS-485 / 4–20 mA analog output |
| Enclosure Rating | IP65 (drip-proof configuration available) |
| Compliance | HACCP-aligned design for food safety monitoring |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-550 |
| Measurement Range | −50 to 500 °C |
| Spectral Response | 8–16 µm |
| Distance-to-Spot Ratio | 15:1 (1 m → Ø24 mm) |
| Emissivity Adjustment Range | 0.10–1.00 (0.01 step) |
| Accuracy | ±1.5 °C or ±1.5 % of reading (whichever is greater, at 23 ±5 °C ambient) |
| Repeatability | ±0.5 °C |
| Response Time (t₉₀) | ≤250 ms |
| Operating Ambient Temperature | 0 to 50 °C |
| IP Rating | IP54 (optional drip-proof configuration available) |
| Output Interface | Analog 4–20 mA / 0–5 V DC (configurable), RS-485 Modbus RTU |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-208 |
| Price | Upon Request |
| Display | 192 × 64 dot-matrix LCD (Chinese/English selectable) |
| Measurement Range | 0–20 mg/L or 0–50 mg/L |
| Resolution | 0.01 mg/L |
| Basic Error | ±2% FS |
| Repeatability | ≤1% |
| Stability | ±1% FS / 4 h |
| Ambient Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | 40 W |
| Dimensions (L×W×H) | 392 × 260 × 100 mm |
| Weight | 5 kg |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GHD-1000 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHD-3000 |
| Pricing | Available Upon Request |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHD-3100 |
| Pricing | Upon Request |
| Operating Principle | Electronic Pressure Control |
| Display | Digital LCD |
| Working Medium | Compressed Air |
| Battery | 5800 mAh Rechargeable Li-ion (≥7 days continuous operation) |
| Flow Control | Precision Electronic Mass Flow Control with Mechanical Fine-Tuning |
| Sample Interface | Universal SUMMA Canister Coupling (6-port or 12-port compatible) |
| Internal Surface Treatment | Silanized Stainless Steel Flow Path (including all internal tubing and fittings) |
| Environmental Rating | IP65 (Dust-tight, Water-resistant) |
| Brand | HUANKONG |
|---|---|
| Model | GHK-6010 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | JJG711-1990, HJ15-2019, HJ353-2019, HJ354-2019, HJ355-2019 |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) |
| Display | 7-inch Color TFT Touchscreen |
| ADC Resolution | 24-bit |
| Data Storage Capacity | 50,000 Records |
| Battery Life | Up to 72 Hours (Li-ion Rechargeable) |
| Connectivity | USB 2.0, RS232, Optional GNSS (GPS/BeiDou) |
| Printing | Integrated Thermal Microprinter |
| Portability | Carry-on Case Design, <3.2 kg Total Weight |
| 堰 Compatibility | V-notch, Rectangular, Parshall, and Trapezoidal (UST) Weirs |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-6010 |
| Liquid Mass Flow Accuracy | ±0.1% FS |
| Signal Acquisition Resolution | 24-bit |
| Data Storage Capacity | 50,000 records |
| Battery Life | Up to 72 hours (fully charged) |
| Display | Color TFT LCD with capacitive touch interface |
| Connectivity | USB port for data export and printer interface |
| Optional | GNSS positioning (GPS/BeiDou) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Category | Domestic (China) |
| Model | GHK-7000 |
| Pricing | Upon Request |
| Flow Measurement Principle | Differential Pressure |
| Key Components | Orifice Module, Soap Film Module, Thermal Mass Flow Module, Microcontroller Unit, TFT Touch Display |
| Calibration Standards | JJG 586–2006, JJG 700–2016, JJF 2033–2023 |
| Operating Modes | Real-time flow display (actual, STP @ 273.15 K / 101.325 kPa, NTP @ 293.15 K / 101.325 kPa, RTP @ 298.15 K / 101.325 kPa) |
| Data Storage | 80 entries per range |
| Power Supply | Rechargeable Li-ion battery (>8 h runtime) |
| Interface | USB port (U-disk export supported), Optional Bluetooth thermal printer |
| Environmental Input | Manual barometric pressure & ambient temperature entry |
| Sensor Calibration | Digital calibration for flow, differential pressure, temperature, time, and battery voltage |