Measurement Instruments
Filter
Showing 1201–1230 of 2731 results
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | GR-50-AA / GR-300-AA / GR-1400-AA |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported |
| Model | Hall Effect Sensor |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | HR Series |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 211 |
| Temperature Range | 1.4 K to 800 K |
| Input Channels | 1 |
| Sensor Types Supported | Silicon Diode, GaAlAs Diode, 100 Ω Pt, 1000 Ω Pt, Carbon-Glass, Cernox®, Rox™ |
| A/D Resolution | 24-bit |
| Measurement Update Rate | 7 Hz |
| Display Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Display | 5-digit LED |
| Output Options | 0–10 V, 4–20 mA, Relay, RS-232/RS-485 Serial Interface |
| User Calibration Curves | 1 × 200-point non-volatile memory |
| Excitation Method | Constant-current, 4-wire differential |
| Isolation | Not chassis-ground isolated |
| Compliance | Designed for cryogenic vacuum and magnetic field environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 218 |
| Input Channels | 8 |
| Sensor Compatibility | Diode (Si, GaAlAs) and Resistance (Pt100, Pt1000, Germanium, Carbon-Glass, Cernox®, Rox™) |
| Temperature Range | 1.2 K to 375 K |
| Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Update Rate | 16 readings/s total (2 full scans of all 8 channels per second) |
| Calibration Curves | 8 × 200-point user-definable curves |
| SoftCal™ Support | DT-470 diode (30–375 K, ±0.25 K improvement), Pt resistance (70–325 K, ±0.25 K improvement) |
| Interfaces | IEEE-488 (GPIB), RS-232C, dual analog voltage outputs, 8 relay outputs |
| Display | 4-line × 20-character backlit LCD |
| Excitation | 8 independent constant-current sources, 4-wire differential measurement |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 224 |
| Sensor Channels | 12 (2 dedicated, 10 multiplexed) |
| Operating Range | 300 mK to 375 K |
| Input Types | Cernox®, silicon diodes (e.g., DT-670), Pt RTDs (100 Ω / 1000 Ω), Rox™, germanium, carbon-glass |
| A/D Resolution | 24-bit |
| Update Rate | up to 10 readings/s (dedicated channels), 1–2 readings/s (scanned channels) |
| Isolation | optical isolation between sensor inputs and system ground |
| Calibration Storage | 39 user-defined 200-point curves |
| Display | 240 × 64 pixel LCD (8 × 40 characters), LED backlit |
| Interface | front-panel 6-pin DIN connectors |
| Compliance | designed for GLP/GMP-aligned lab environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | PT-100 |
| Pricing | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | Rox™ Series (RX-102A, RX-202A, RX-103A) |
| Temperature Range | 0.05 K to 40 K (RX-102A/RX-202A) |
| Resistance at 300 K | 1 kΩ (RX-102A), 2 kΩ (RX-202A), 10 kΩ (RX-103A) |
| Calibration Accuracy | ±16 mK @ 4.2 K (RX-102A/RX-202A) |
| Magnetic Field Tolerance | < 0.1% resistance shift in ≤ 12 T fields |
| Radiation Hardness | Qualified for neutron/gamma irradiation environments up to 1 × 10¹⁵ n/cm² (E > 1 MeV) |
| Thermal Dissipation | 7.5 × 10⁻⁸ W @ 4.2 K (RX-102A/RX-202A) |
| Time Constant | 0.5 s @ 4.2 K, 2.5 s @ 77 K |
| Repeatability | ±15 mK @ 4.2 K |
| Long-Term Stability | ±30 mK @ 4.2 K (RX-102A), ±50 mK (RX-202A), ±15 mK (RX-103A) |
| Compliance | NIST-traceable calibration, ISO/IEC 17025 accredited lab reporting, GLP-compliant documentation available |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | RX-102B-RS |
| Price | Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Lake Shore TC Series |
| Pricing | Upon Request |
| Brand | Lambrecht |
|---|---|
| Origin | Germany |
| Model | 15184 |
| Measurement Principle | Weighing + Automatic Emptying |
| Resolution | 0.001 mm |
| Accuracy | ±0.1 mm/min or ±2% |
| Measuring Range | 0.005–10 mm/min (0–600 mm/h) |
| Catchment Area | 200 cm² |
| Heating Power | 80 W (funnel) + 60 W (outlet), 24 V DC |
| Output Options | SDI-12, RS-485 (ASCII/TALKER), dual pulse, 4–20 mA / 0–2.5 V / 0–5 V |
| IP Rating | IP67 |
| Dimensions | H 292 mm × Ø 159.6 mm |
| Weight | 3.5 kg |
| Compliance | WMO No. 8, VDI 3786 Bl. 7, EN 61000-2/-4, EN 61000-4-2/3/4/5/6/11, NAMUR NE-21 |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Model | P1200B |
| Temperature Range | 150–1150 °C |
| Cavity Diameter | 50 mm |
| Cavity Depth | 400 mm |
| Emissivity | 0.998 |
| Temperature Stability | ±0.2 °C over 60 min |
| Temperature Uniformity | < ±0.15% t across central 40 mm of 50 mm cavity |
| Heating Rate | ~2 h to reach 1000 °C |
| Controller | Eurotherm PID with N-type Thermocouple |
| Power Supply | 220–240 V, 50–60 Hz |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Model | P1600B2 |
| Temperature Range | 500–1550 °C |
| Emissivity | 0.998 |
| Stability | ±0.2 °C per 60 min |
| Uniformity | < ±0.15% of setpoint over central 40 mm of 50 mm-diameter cavity |
| Cavity Dimensions | Ø50 mm × 400 mm |
| Temperature Resolution | 1 °C |
| Heating Time | 90 min to 1400 °C |
| Cooling Time | 180 min to 200 °C |
| Ambient Operating Conditions | 10–40 °C |
| Controller | Eurotherm PID with Type R Thermocouple |
| Power Supply | 220–240 V, 50–60 Hz |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Category | Domestic (China) |
| Model | LJ-DJ1S |
| Price | USD 850 (FOB Qingdao) |
| Measurement Principle | Dual-Beam UV254 Absorption + Nephelometric Turbidity |
| COD Range | 0–500 mg/L (customizable to 0–200 mg/L) |
| COD Resolution | 0.1 mg/L |
| COD Accuracy | ±5% of reading |
| Turbidity Range | 0–400 NTU (customizable to 0–200 NTU) |
| Turbidity Resolution | 0.1 NTU |
| Temperature Range | 0–50 °C |
| Temp. Accuracy | ±0.3 °C |
| Temp. Compensation | Automatic |
| Auto-Cleaning | Integrated mechanical wiper with programmable cycle control |
| Power Supply | DC 12–24 V |
| Power Consumption | 0.7 W |
| Output | RS-485 (Modbus RTU protocol) |
| Enclosure Material | ABS housing + 316L stainless steel wetted parts |
| Protection Rating | IP68 |
| Installation | Submersible, 3/4" NPT thread |
| Cable Length | 5 m (5-conductor shielded) |
| Storage Temperature | −5 to +65 °C |
| Calibration | Two-point (zero & span) for both COD and turbidity channels |
| Dimensions | See technical drawing (L×W×H: 185 × 62 × 62 mm) |
| Compliance | Designed per ISO 7027 (turbidity), ASTM D5540 & EPA 415.3 (UV254-based organic carbon estimation), CE-marked for EMC and LVD |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LJ-DP501 |
| Liquid Mass Flow Accuracy | ±1.0% ± 1 mm/s |
| Liquid Level Range | 0–10 m (Resolution: 0.001 m) |
| Velocity Range | 0–5 m/s (Accuracy: <5%, Resolution: 0.001 mm/s) |
| Instantaneous Flow Range | 0–999,999,999 m³/h (Resolution: 0.1 m³/h) |
| Totalized Flow Range | 0–999,999,999 m³ |
| Temperature Range | −10–70 °C (Accuracy: ≤±0.5 °C, Resolution: 0.1 °C) |
| Housing Material | PVC |
| Power Consumption | <2 W |
| Display | TFT Color LCD |
| Protection Rating | IP65 (Host), IP68 (Sensor) |
| Power Supply | Rechargeable 12 V Li-ion Battery (Host), 9–24 V DC (Sensor) |
| Output Signals | RS-485 (standard), 4–20 mA analog output (standard), HART / NB-IoT / LoRa (optional) |
| Installation Method | Submersible Mount with Adjustable Bracket |
| Standard Cable Length | 10 m (Polyurethane, corrosion-resistant, extendable) |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | LJ-LS5+ |
| Price | USD 1,200 (FOB) |
| Measurement Range | 0.1–30 m/s |
| Accuracy | ±3% FS or ±0.01 m/s (whichever is greater) |
| Radar Frequency | 24 GHz |
| Beam Angle | 24° × 12° (elevation × azimuth) |
| Transmit Power | 18 dBm (63 mW peak), nominal 10 mW average |
| Max Measurement Distance | ≤100 m |
| Operating Temperature | −30 °C to +70 °C |
| Storage Temperature | −30 °C to +70 °C |
| Relative Humidity | 20–80% RH |
| Ingress Protection | IP67 |
| Battery Capacity | 3600 mAh Li-ion |
| Continuous Operation | >10 h |
| Data Storage | 10,000 records |
| Display | 3.5″ capacitive touchscreen |
| Interface | USB Type-A for USB flash drive data export |
| Built-in Tilt Sensor | Automatic horizontal & vertical angle compensation |
| Housing Material | ABS resin enclosure with aluminum frame |
| Weight | <1 kg |
| Brand | Lanjing |
|---|---|
| Model | LJ-SX128 |
| Channels | 128 |
| Sensor Type | MEMS Digital Microphone Array |
| Dynamic Range | 30 dB to 120 dB |
| Frequency Range | 2 kHz – 48 kHz |
| Measurement Distance | 0.5 m – 50 m |
| Operating Temperature | −20 °C to +55 °C |
| IP Rating | IP51 |
| Display | 5″ Capacitive Touch LCD (800 × 480) |
| Imaging & Video Frame Rate | 25 FPS |
| Built-in Storage | 64 GB |
| Battery | Internal Li-ion (7.4 V, 3500 mAh |
| Weight | <1 kg |
| Dimensions | 314 mm × 167 mm × 89.9 mm |
| Data Interface | USB, Wi-Fi |
| Self-Diagnostic Microphone Array | Yes |
| Data Logging & Traceability | Yes |
| Infrared Imaging | No |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster 4D-PTV |
| Measurement Modality | Stereoscopic 3D3C (Three-Component, Three-Dimensional) |
| Temporal Resolution | >100 Hz |
| Velocity Range | 0–1000 m/s |
| Velocity Uncertainty | ±1% of measured value |
| Measurement Volume | 1000 mm × 1000 mm × 1000 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster FSI |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Frame Rate | >100 Hz |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured value |
| Measurement Volume | 1000 mm × 1000 mm × 1000 mm |
| Technique Integration | Synchronized Particle Image Velocimetry (PIV) and Digital Image Correlation (DIC) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster-STB |
| Measurement Capability | True 3D, three-component (3D3C) volumetric velocity field |
| Measurement Frequency | Low-to-medium temporal resolution (suitable for transient and quasi-steady flows) |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured velocity magnitude |
| Measurement Volume | 1 m × 1 m × 1 m (adjustable via optical configuration and seeding density) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster® 3D |
| Measurement Dimensionality | 2D & 3D planar vector fields |
| Frame Rate | >100 Hz |
| Velocity Range | 0–3,000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Field Size | 1 m × 1 m |
| Optical Configuration | Dual-camera stereoscopic imaging with Scheimpflug-aligned lenses |
| Calibration | Self-calibration enabled (target-free, off-field, distortion-corrected) |
| Software Platform | DaVis® v10+ |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster® |
| Measurement Capability | 2D & 3D planar velocity fields |
| Velocity Range | 0–2000 m/s |
| Accuracy | <1% RMS error |
| Measurement Area | 400 × 400 mm |
| Laser Pulse Energy | up to 2 × 425 mJ per pulse |
| Camera Resolution Options | 1 MP to 29 MP |
| Temporal Resolution | Single-shot to MHz-rate TR-PIV |
| Correlation Precision | ≤0.1 pixel |
| SNR (Velocity Field) | >45 |
| High-Confidence Vector Yield (>0.1 px error threshold) | >90% |
| Compliance | ASTM E2847, ISO 20486, GLP/GMP-ready data audit trail support in DaVis |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster® thermographic |
| Measurement Capability | Planar (2D/3D) |
| Repetition Rate | 3 kHz |
| Velocity Range | ≤ 3.5 km/s |
| Temperature & Velocity Accuracy | ±1% of reading |
| Measurement Field Size | 200 mm × 200 mm |
| Particle Tracer | Micrometer-scale thermographic phosphor particles |
| Core Principle | Simultaneous phosphorescence lifetime-based thermometry and cross-correlation PIV |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Adaptive |
| Measurement Domain | 2D/3D Planar |
| Measurement Frequency | Low-Frequency |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% |
| Measurement Area | 1 m × 1 m |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-Dual |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-Frequency Operation (Typical Repetition Rates: 1–15 Hz for Dual-Plane Acquisition) |
| Velocity Range | 0–2,000 m/s |
| Accuracy | ±1% of Measured Velocity Magnitude |
| Measurement Field of View | Up to 1.0 m × 1.0 m (Configurable via Lens and Laser Sheet Geometry) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Endo |
| Measurement Domain | Planar (2D/3D) |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% of reading |
| Field of View | Up to 1 m × 1 m |
| Frame Rate | Low-frequency acquisition (typically < 100 Hz for high-resolution endoscopic configurations) |
| Optical Bandpass | Visible to UV (193–700 nm) |
| Compliance | Designed for integration with ASTM E2847, ISO 20456, and GLP/GMP-aligned experimental workflows |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-Micro |
| Measurement Domain | 2D & 3D planar velocity fields |
| Measurement Frequency | Low-frequency dual-pulse acquisition |
| Velocity Range | 0–10 m/s |
| Accuracy | ±1% of measured velocity |
| Field of View | 10 µm – 1 mm |
| Objective Magnification Range | 5× – 40× |
| Standard Camera | 1376 × 1040 pixels, 65% quantum efficiency @ 500 nm |
| Spatial Resolution | Down to ~0.1 pixel displacement uncertainty |
| Microscope Configuration | Upright or inverted fluorescence-compatible platform |
| Illumination Source | Dual-pulse Nd:YAG laser (typically 532 nm) |
| Tracer Compatibility | Fluorescent microspheres (e.g., Rhodamine B-doped polystyrene, 0.1–2 µm diameter) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-surf |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-frequency |
| Velocity Range | 0–2 km/s |
| Accuracy | ±1% of reading |
| Field of View | Up to 1 m × 1 m |
| Camera Requirement | Dual-camera stereo configuration |
| Core Technology | Digital Image Correlation (DIC) + Stereoscopic PIV |
| Software Platform | DaVis® v8.4+ |
| Compliance | ASTM E2847, ISO/IEC 17025-compatible workflows, GLP-aligned data traceability |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-Tomo |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-to-Medium Repetition Rate (Typical Dual-Frame Acquisition) |
| Velocity Range | 0–2000 m/s |
| Accuracy | ±1% of measured velocity magnitude |
| Measurement Volume | 170 mm × 110 mm × 100 mm |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowMaster®-TR |
| Measurement Domain | 2D & 3D Planar |
| Frame Rate | >100 Hz (up to 100 kHz at reduced resolution) |
| Velocity Range | 0–8000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Area | 400 × 400 mm |
| Camera Resolution | 1024 × 1024 pixels @ 5 kHz |
| Laser | High-Repetition Solid-State, Dual-Cavity, up to 50 mJ/pulse |
| Software Control | Fully integrated with DaVis® v10+ |
