| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | FlowMaster®-UW |
| Measurement Domain | Planar (2D/3D) |
| Measurement Frequency | Low-frequency operation |
| Velocity Range | 0–2,000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Area | Up to 1 m × 1 m |
| Optical Architecture | Modular submersible configuration with surface-mounted electronics |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments and GLP-compliant fluid dynamics research |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ICOS-Temperature |
| Application Domain | In-cylinder combustion diagnostics |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in the near-infrared (NIR) range |
| Output Resolution | Crank-angle-resolved (≤0.1° CA), single-cycle or multi-cycle averaged |
| Probe Options | Non-intrusive fiber-coupled optics or minimally intrusive sapphire-windowed probes |
| Compliance | Designed for integration into ISO 2534, SAE J1939, and EU Regulation (EC) No 715/2007 test environments |
| Data Interface | Ethernet (TCP/IP), synchronized with engine position encoder (e.g., AVL PUMA, ETAS INCA) |
| Brand | LaVision GmbH |
|---|---|
| Country of Origin | Germany |
| Model | OA-STB |
| Measurement Capability | 3D3C (Three-Dimensional, Three-Component) |
| Measurement Frequency | Low-Frequency Temporal Resolution |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±1% of measured velocity |
| Measurement Volume | 1 m × 1 m × 1 m |
| Software Requirement | DaVis 11.2 or later |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LED-5000 |
| Quotation | Upon Request |
| Luminous Intensity Measurement Angle Range | ±90° |
| Angular Resolution | 1° or 2° selectable |
| Angular Accuracy | ≤ ±0.25° |
| Photodetector | Silicon Photodiode |
| Spectral Response Range | 320–1100 nm |
| Test Distance | 100 mm |
| Aperture Diameter | 3.6 mm |
| Cap Diameter | Standardized for collimated beam alignment |
| Sensitivity Adjustment | Automatic |
| PC Interface | RS-232C serial port |
| Dimensions (W×D×H) | 500 × 440 × 430 mm |
| Constant Current/Voltage Source Output | 0–100 mA / 0–10 V |
| Current Setting Accuracy | ±0.1 mA, Temp. Coefficient: 200 ppm/℃ |
| Software Compatibility | Windows OS (7/10/11) |
| Data Export Format | CSV |
| Brand | LEI-TECH |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LK-SZB564 |
| Configuration | Bridge-Type |
| Operation Mode | Fully Automatic |
| Instrument Orientation | Vertical |
| Measurement Principle | Contact-Based Tactile Probing |
| Measurement Volume (X×Y×Z) | 500 mm × 600 mm × 400 mm |
| Volumetric Accuracy | E ≤ (2.8 + L/300) µm |
| Probe System | YF1 + RA20 + RA13 (TELES), with Standard Force Module and M2 Interface |
| Probe Tip Mass | 22 g |
| Length Measurement System | Reflective Metallic Tape Encoder Scale |
| Maximum Permissible Temperature Deviation | ±1 °C (Standard Environment: 18–22 °C) |
| Relative Humidity Range | 40–70 % RH |
| Power Supply | 220 V ±10 %, 50–60 Hz |
| Minimum Air Supply Pressure | ≥0.55 MPa |
| Maximum Workpiece Load | 100 kg |
| Structural Material | Granite (All Three Axes) |
| Y-Axis Guideway | P-Class Precision Linear Rail |
| Drive System | High-Performance DC Servo Motor with Timing Belt Transmission |
| Control Architecture | Dual-Computer Embedded CMM Controller |
| Software Platform | MSU3D PRO v5.x (Proprietary 3D Metrology Suite) |
| Key | Brand: Leica |
|---|---|
| Model | AT500 |
| Max Measurement Range | 320 m |
| Angular Resolution | 0.07 arcsec |
| Positional Accuracy | ±0.1 mm |
| Horizontal Rotation | 360° |
| Vertical Pitch | ±145° |
| Tilt Capability | ±145° |
| IP Rating | IP54 |
| Operating Temperature | −15 °C to +50 °C |
| Laser Class | IEC 60825-1:2014 Class 2 |
| Compliance | ISO/IEC 17025, ISO 10360-10 |
| Brand | Leica |
|---|---|
| Origin | Switzerland |
| Model | Leica AT930 |
| Max Measurement Range | 160 m (diameter) |
| Horizontal Rotation | 360° |
| Vertical Pitch | ±145° |
| IP Rating | IP54 (IEC 60529) |
| Operating Temperature | 0 °C to 40 °C |
| Relative Humidity | Up to 95% (non-condensing) |
| Laser Class | Class 2, compliant with IEC 60825-1:2014 |
| Data Output Rate | 1000 Hz |
| Integrated Environmental Monitoring | Temperature, Pressure, Humidity |
| Power Options | Hot-swappable rechargeable battery & AC supply |
| Wireless Connectivity | Built-in Wi-Fi (IEEE 802.11 a/b/g/n/ac) |
| Onboard Imaging | High-resolution color panoramic camera (OVC) |
| Target Acquisition | PowerLock™ automatic target reacquisition |
| Measurement Principle | Absolute Interferometric Distance Measurement (AIFM) |
| Brand | Leica |
|---|---|
| Manufacturer | Hexagon Manufacturing Intelligence |
| Model | AT960 |
| Measurement Range Diameter | up to 160 m |
| Positioning Accuracy | ISO 10360-compliant (typical volumetric accuracy < 15 µm + 6 µm/m) |
| Dynamic Tracking Rate | up to 1000 Hz (7DoF output) |
| Weight | < 14 kg |
| Environmental Compensation | Integrated temperature, pressure, and humidity sensors (per ISO 10360-8 & VDI/VDE 2634 Part 2) |
| IP Rating | IP54 |
| Power | Hot-swappable Li-ion battery pack |
| Communication | Built-in Wi-Fi 802.11ac, Ethernet, Bluetooth 5.0 |
| Target Acquisition | PowerLock™ automatic beam reacquisition |
| Optical System | Absolute Interferometric Distance Meter (AIFM) with panoramic OVC camera (HD color, 120° FOV) |
| Compliance | Meets requirements for ISO 17025-accredited metrology labs, supports FDA 21 CFR Part 11 audit trails via Leica Metrology Software (LMS) |
| Brand | Leica |
|---|---|
| Origin | Switzerland |
| Model | ATS600 |
| Max Measurement Range | 80 m |
| Horizontal Rotation | 360° |
| Vertical Pitch | ±145° |
| IP Rating | IP54 |
| Operating Temperature | 0 °C to +40 °C |
| Relative Humidity | ≤95% (non-condensing) |
| Laser Class | IEC 60825-1:2014 Ed.2 Class 2 |
| Environmental Monitoring | Integrated temperature, pressure & humidity sensors |
| Brand | Leica |
|---|---|
| Origin | Switzerland |
| Instrument Type | Handheld Laser Distance Meter |
| Measurement Principle | Time-of-Flight Laser Ranging |
| Measurement Range | 0.05 m – 100 m |
| Accuracy | ±1.0 mm |
| Tilt Sensor Accuracy | ±0.3° |
| Display Resolution | 0.1 mm |
| Operating Temperature | −10 °C to +50 °C |
| IP Rating | IP54 |
| Battery Life | Up to 5,000 measurements per set of 2 x AAA batteries |
| Compliance | CE, RoHS, FDA Class I Laser Product (IEC 60825-1) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | D3a |
| Pricing | Upon Request |
| IP Rating | IP65 |
| Measurement Range | 0.05–100 m |
| Typical Accuracy | ±1 mm |
| Angular Accuracy | ±0.3° |
| Angle Measurement Range | ±45° |
| Laser Class | II |
| Laser Wavelength | 635 nm |
| Max. Laser Output | <1 mW |
| Battery Life | Up to 5,000 measurements per set |
| Display | 4-line backlit LCD |
| Connectivity | Integrated Bluetooth 4.0 |
| Data Storage | Last 20 measurements |
| Environmental Protection | Splash-proof and dust-tight (IEC 60529 IP65) |
| Housing | Dual-material with shock-absorbing rubber overmold |
| Measurement Modes | Direct distance, indirect (Pythagorean), area, volume, continuous measurement, min/max tracking |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | DFC425 |
| Sensor Type | 5 MP CCD |
| Interface | C-mount |
| Preview Frame Rate | up to 20 fps at XGA resolution |
| Output Format | RGB 24-bit |
| Software Compatibility | Leica Application Suite (LAS) X, Windows/macOS/Linux |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (via LAS X audit trail) |
| Cooling | Passive thermal management |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | DM4 M |
| Type | Upright Metallurgical Microscope |
| Measurement Principle | Reflected Light Optical Microscopy (Not White Light Interferometry) |
| Automation Level | Semi-Automatic (Motorized Objective Turret, Motorized XY Stage, Adjustable LED Illumination) |
| Application Domain | Metallographic Structure Observation, Grain Size Analysis, Phase Identification, Failure Analysis, QC/QA in Metals & Alloys |
| Compliance | Designed for ISO 9001, ASTM E3, ASTM E112, ASTM E1245, ISO 643, ISO 10770-1, and GLP-compliant documentation workflows |
| Brand | HEXAGON |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | ATS800 |
| Price | USD 420,000 (approx.) |
| Max Measurement Range | Ø80 m |
| IP Rating | IP54 |
| Operating Temperature | 0 °C to +40 °C |
| Relative Humidity | ≤95% (non-condensing) |
| Laser Class | IEC 60825-1:2014 Ed.2 Class 1 |
| Environmental Monitoring | Integrated temperature, pressure & humidity sensors |
| Power | Rechargeable battery pack with hot-swap capability |
| Connectivity | Built-in Wi-Fi 5 (802.11ac), Ethernet, USB-C |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | IC A |
| Type | Analog Color Camera |
| Mounting | C-mount compatible for stereo microscopes |
| Output | Composite video (NTSC/PAL) |
| Resolution | 752 × 582 pixels (effective) |
| Sensor | 1/3" Sony CCD |
| Sensitivity | 1.0 lux @ F1.2 |
| White Balance | Manual and one-push auto |
| Gain Control | Manual |
| Video Interface | BNC (composite) |
| Power Supply | 12 V DC via external adapter |
| Dimensions | 64 × 64 × 89 mm |
| Weight | 320 g |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | ICC50 HD |
| Image Sensor Resolution | 3 MP (2048 × 1536) |
| Output Interface | USB 2.0 |
| Storage | Internal SD card slot (up to 32 GB) |
| Live Frame Rate | Up to 30 fps at VGA resolution |
| Color Depth | 24-bit RGB |
| Software Compatibility | LAS EZ, LAS X (basic modules), and full Leica Application Suite (LAS) platform |
| Operating System Support | Windows 7/10/11 (64-bit), macOS 10.15–13.x (via compatible drivers) |
| Mounting Interface | C-mount (with optional adapters for Leica DM series) |
| Power Supply | USB bus-powered |
| Brand | Leitz |
|---|---|
| Origin | Germany |
| Configuration | Bridge-Type |
| Operation Mode | Automatic |
| Orientation | Vertical |
| Measurement Method | Combined Contact and Non-Contact |
| Software Platform | QUINDOS & PC-DMIS |
| Structural Design | Floor-Standing, No Foundation Required |
| Environmental Tolerance | Ambient Workshop Installation (No Air-Conditioned Room Required) |
| Integration Capability | CAQ Network Compatible |
| Probe System | Leitz LSP Series (Max. Probe Length: 800 mm, Max. Probe Mass: 1000 g) |
| Dynamic Performance | Up to 660 mm/s Scanning Speed, Up to 3250 mm/s² Acceleration |
| Repeatability | Sub-micron Level Across Full Volume |
| Compliance Context | Designed for ISO 10360-2, ISO 15530-3, VDI/VDE 2617, and GLP/GMP-aligned QA workflows |
| Brand | Leitz |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMM-G |
| Configuration | Bridge-Type |
| Operation Mode | Fully Automatic |
| Instrument Orientation | Vertical |
| Measurement Principle | Contact-Based Metrology with Multi-Sensor Integration |
| Maximum Travel Range | 7000 × 4000 × 3000 mm |
| Standard Temperature Range | 18–22 °C |
| Z-Axis Material | Ceramic |
| Guideway Material | Granite |
| Bearing System | Air Bearings with Electronic Gap Monitoring |
| Positioning Resolution | 0.005 µm |
| Vibration Isolation | Active Damping System |
| Thermal Compensation | Integrated Environmental Sensor Network |
| Safety Systems | Dual Laser Scanners + Collision Avoidance Logic |
| Compliance Framework | ISO 10360-2, ISO 15530-3, VDI/VDE 2617, ASTM E1352, GLP/GMP-Ready Data Audit Trail |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | CTR 100 |
| Measurement Principle | Ceramic Diaphragm Capacitance |
| Range | 1000 to 0.1 Torr |
| Vacuum Port | KF 16 |
| Output | 0–10 V analog + RS232 digital interface |
| Accuracy | ±0.12% of full scale |
| Sensor Material | Al₂O₃ ceramic diaphragm with 316 stainless steel flange |
| Temperature Compensation | Integrated |
| Overpressure Tolerance | ≥2× full scale |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | DISPLAY |
| Channel Options | 1-Channel or 3-Channel |
| Pressure Range | 10⁻⁹ mbar to 2000 mbar |
| Compatible Sensor Families | THERMOVAC TTR, DU, PENNINGVAC PTR |
| Compliance | CE, RoHS, EN 61000-6-2/-6-4 |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | GRAPHIX |
| Channel Options | 1-channel, 2-channel, 3-channel |
| Pressure Range | 1×10⁻¹⁰ mbar to 2000 mbar |
| Sensor Compatibility | THERMOVAC TTR, CERAVAC CTR, DU, PENNINGVAC PTR, IONIVAC ITR series active sensors |
| Operating Principle | Digital signal processing of analog or digital outputs from active vacuum sensors |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | IE 514 |
| Measurement Principle | Cold Cathode Ionization |
| Pressure Range | 1 × 10⁻¹² to 1 × 10⁻⁴ mbar |
| Vacuum Flange | CF 40 |
| Compliance | ISO 3567, DIN 28403-1, EN 61000-6-3 |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PTR 90 |
| Measurement Principle | Pirani + Cold Cathode (Penning) |
| Range | 1×10³ to 1×10⁻⁸ mbar |
| Vacuum Port | KF 25, CF 40 |
| Output Interface | RS232 / RS485 (digital), optional analog 0–10 V or 4–20 mA |
| Accuracy | ±30% (1×10⁻⁸–1×10⁻² mbar), ±15% (1×10⁻²–10 mbar) |
| LED Indication | Adaptive pulse-mode pressure display |
| Housing | Compact stainless steel, IP65-rated |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TM 201 |
| Measurement Principle | Piezoresistive + Pirani |
| Range | 1200 to 5.0 × 10⁻⁵ mbar |
| Pressure Interface | KF 16 |
| Relative Pressure Capability | –1060 to +1200 mbar |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing environment |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TTR 101 |
| Measurement Principle | Combined Pirani + Capacitive Diaphragm |
| Range | 5×10⁻⁵ – 1500 mbar |
| Vacuum Port | KF 16 |
| Compliance | CE, RoHS, ISO 9001-manufactured design |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | TTR 91 RN |
| Measurement Principle | Pirani (thermocouple-based thermal conductivity) |
| Range | 1 × 10³ to 5 × 10⁻⁴ mbar |
| Vacuum Port | KF 16 (DN 16) |
| Accuracy | ±50% (100–10 mbar), ±15% (10–1×10⁻³ mbar), ±50% (1×10⁻³–5×10⁻⁴ mbar) |
| Repeatability | ±2% (100–1×10⁻³ mbar) |
| Power Supply | 15–48 V DC |
| Analog Output | 0–10 V |
| Digital Interface | RS232 or RS485 |
| Electrical Connector | RJ45 or 9-pin D-sub |
| Integrated Particle Filter | Yes |
| Filament Options | Tungsten (standard), Platinum (harsh environments) |
| Operating Temperature | 5–60 °C |
| Max Bakeout Temp (electronics removed) | 150 °C |
| IP Rating | IP40 |
| Certifications | CE, UKCA |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-550 |
| Dimensions | 9.1 cm × 9.1 cm × 5.2 cm |
| Measurement Path Length | 35 mm |
| Weight | ≤50 g |
| Power Supply | 5–32 VDC @ 320 mW |
| Output Interfaces | RS-232 (LI-550), RS-232/RS-422/UART-3V (LI-550P) |
| Sampling Frequencies | 1, 2, 5, 10, 20, 40 Hz |
| Ultrasonic Frequency | 60 kHz |
| Wind Speed Range | 0–50 m/s |
| Wind Speed Resolution | 0.01 m/s |
| Wind Speed Accuracy | ±0.2 m/s (0–10 m/s), ±2% (11–30 m/s), ±4% (31–50 m/s) |
| Wind Direction (u/v) | 0–359°, Resolution: 1°, Accuracy: ±1° |
| Vertical Wind Component (w) Range | ±15° |
| Temperature Range | −20 to +72 °C, Resolution: 0.01 °C, Accuracy: ±2.0 °C |
| Relative Humidity Range | 0–100 %RH, Resolution: 0.1 %RH, Accuracy: ±3 %RH |
| Barometric Pressure Range | 50–115 kPa, Resolution: 0.1 kPa, Accuracy: ±1.0 kPa |
| 3D Accelerometer Range | ±2 g (u/v/w), Tilt (Pitch/Roll): ±90° |
| Magnetometer Range | ±50 Gauss (u/v/w), Heading Accuracy: ±5° |
| Dew Point & Air Density | Computed from measured T, RH, and P |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 |
| Temperature Range | –196 °C to +125 °C (with LN₂ cooling pump) |
| Heating Rate | Up to 150 °C/min |
| Temperature Stability | < 0.1 °C |
| Sensor | 100 Ω Platinum RTD |
| Vacuum Level | Down to 10⁻³ mbar |
| Sample Area | Ø22 mm |
| XY Manipulation Range | 15 mm |
| Window Thickness | 0.5 mm (single ultra-thin optical window) |
| Sample Volume | As low as 5 µL |
| Compatible With | Polarized light, phase contrast, confocal microscopy, Raman spectroscopy, FTIR, and X-ray imaging |
| Brand | Longteng |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES Series |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Instrument Type | Precision Mass Comparator |
| Maximum Capacity | 5,000 g |
| Readability | 0.01 g |
| Repeatability | ≤ ±0.01 g |
| Calibration Method | Automatic Internal Calibration |
| Pan Dimensions | Up to 340 × 300 mm |
| External Dimensions | Up to 460 × 315 × 160 mm |
| Compliance | Meets JJG 99-2006 (Chinese National Verification Regulation for Weights), ISO/IEC 17025 traceable operation |
| Brand | Longteng |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ES Series Standard |
| Instrument Type | Platform Balance |
| Maximum Capacity | Up to 600 kg |
| Readability | 0.5 g to 200 g (model-dependent) |
| Calibration Method | Manual |
| Repeatability | ≤ ±2 g |
| Sensor Technology | Strain Gauge |
| Power Supply | AC/DC with Built-in Rechargeable Battery |
| Connectivity | RS-232 Interface for PC Data Transfer |
| Compliance | Meets GB/T 26497–2011 (Chinese National Standard for Electronic Balances), CE-marked for industrial use |