Measurement Instruments
Filter
Showing 1291–1320 of 2732 results
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-108 |
| Instrument Type | Fixed-Mount Thermal Screening Gateway |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Thermal Resolution | ±0.3 °C |
| Measurement Range | 20 °C to 50 °C |
| Detection Distance | 1.5 m to 5 m |
| Throughput Capacity | 150–200 persons/min |
| Blackbody Emissivity | 0.96 ± 0.02 |
| NETD | ≤60 mK (F/1, 300 K, 50 Hz) |
| IR Sensor | Uncooled Microbolometer Array (160 × 120 pixels, 17 µm pitch, 8–14 µm spectral band) |
| Visible Camera | 2 MP CMOS, 6 mm lens, 0.01 Lux (color), SNR > 56 dB |
| Onboard Processing | Broadcom BCM2711 (64-bit quad-core @ 1.5 GHz), VideoCore VI GPU, dual-band Wi-Fi 802.11ac + Gigabit Ethernet |
| Power Input | 5 V/3 A via USB-C |
| Operating Temperature | 0 °C to 40 °C |
| Enclosure | Flame-retardant, waterproof PVC composite (IP54-rated indoor/outdoor use with optional rain canopy) |
| Passage Dimensions | 1900 (H) × 700 (W) × 580 (D) mm |
| Brand | Loobo |
|---|---|
| Model | LB-6200 |
| Origin | Shandong, China |
| Flow Range | 0–40 m³/s |
| Liquid Level Measurement Error | ≤ 0.5 mm |
| Flow Measurement Accuracy | ≤ ±1% |
| Sampling Frequency | 3 Hz |
| Display | Color TFT Touchscreen |
| Data Storage | 20,000 records |
| Battery Life | 72 h (DC 24 V Li-ion) |
| Operating Temperature | 10–40 °C |
| Operating Humidity | ≤ 85% RH |
| Dimensions | 400 × 300 × 110 mm |
| Weight | 4 kg |
| Interface | USB |
| Compliance | HJ/T 15–2019, HJ 354–2019 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | ONG300 |
| Type | Handheld |
| Principle | Pulsed Time-of-Flight Laser Ranging |
| Measurement Range | 0–600 m |
| Accuracy | ±0.3 m |
| Magnification | 7× |
| Objective Lens Diameter | 25 mm |
| Eyepiece Lens Diameter | 16 mm |
| Weight | ~195 g (with batteries) |
| IP Rating | IP54 |
| Operating Temperature | 0–40 °C |
| Laser Safety Class | IEC 60825-1 Class 1 |
| Measurement Modes | Distance, Height, Angle, Speed |
| Angular Range | ±90° |
| Angular Accuracy | <0.3° |
| Speed Measurement Error | ±5 km/h |
| Target Requirements | ≥2 m × 2 m surface area, near-perpendicular incidence, medium reflectivity (e.g., concrete wall), clear atmospheric conditions |
| Brand | Lsi |
|---|---|
| Origin | Italy |
| Model | BSP002 |
| Measurement Range | 800–1100 hPa |
| Accuracy (20°C) | ±1 hPa |
| Resolution | 0.1 hPa |
| Thermal Drift | 3.3 hPa/10°C (-10…+60°C) |
| Response Time (T90) | 1 ms |
| Warm-up Time | 300 s |
| Operating Temperature | -40…+85°C |
| Long-term Stability | 1.1 hPa/year |
| Sea-level Compensation Range | -300…+2000 m ASL |
| Power Consumption | 10 mA |
| Output | Analog (1 channel), 2 m PVC cable |
| Sensor Element | Piezoresistive |
| Calibration Interval | 12 months |
| Compliance | ISO 9001-certified calibration (Certificate DZC001, Procedure PCR002) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | LT-880 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLAS-2D |
| Price | USD 48,500 (FOB) |
| Brand | LUMINA |
|---|---|
| Origin | USA |
| Model | AT1 |
| Type | Non-contact Profilometer / Surface Metrology System |
| Measurement Principle | Multi-modal Optical Scattering, Ellipsometry, Reflectometry, and Surface Slope Analysis |
| Sample Compatibility | Transparent (e.g., fused silica, sapphire, glass), semi-transparent (e.g., GaN, SiC), and opaque substrates (e.g., Si, GaAs, InP, metals) |
| Scan Area | Up to 300 × 300 mm |
| Wafer Handling | Supports 150 mm wafers (full-surface scan in ≤ 3 min), 50 × 50 mm samples in ≤ 30 s |
| Detection Sensitivity | Sub-nanometer vertical resolution for film thickness uniformity |
| Mechanical Architecture | Fixed-optics, non-rotating platform with high inertial damping |
| Regulatory Alignment | Designed for GLP/GMP-compliant environments |
| Brand | m&h |
|---|---|
| Origin | Imported (Non-Chinese) |
| Model | HDR40.00-RX/TX |
| Bidirectional Repeatability (2σ) | 1 µm |
| Recommended Trigger Speed | 254–2000 mm/min |
| Trigger Direction | ±X, ±Y, −Z |
| Maximum Overtravel | XY ±12.5°, Z −6 mm |
| Trigger Force (with 50 mm stylus) | XY = 0.4–1.8 N (adjustable), Z = 4–12 N (adjustable) |
| Power Supply | One 9 V battery or PX28 (6 V) / five LR44 (1.5 V each) |
| IP Rating | IP68 per EN 60529 |
| Weight (excl. toolholder) | 1350 g |
| Operating Temperature Range | 10–50 °C |
| Housing Material | Stainless steel |
| Signal Transmission Rate | 9600 pulses/sec |
| Angular Coverage | 130° (radial), 360° (axial) |
| Transmission Range | 4–10 m (adjustable) |
| Probe Diameter | Φ25–63 mm |
| Probe Length | 110–410 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | TransiTempII, TransiTempII-RH, Cryo-Temp |
| Price | USD 1,450 (FOB) |
| Temperature Range (TransiTempII) | –40 °C to +80 °C |
| Temp. Accuracy | ±0.5 °C |
| Humidity Range (TransiTempII-RH) | 0–95 %RH |
| RH Accuracy | ±5 %RH |
| Temperature Range (Cryo-Temp) | –86 °C to +35 °C |
| Temp. Accuracy (Cryo-Temp) | ±1.0 °C |
| Memory Capacity | 32,767 readings (TransiTempII & Cryo-Temp), 16,383 readings (TransiTempII-RH) |
| Battery Life | Up to 1 year (typical continuous logging at 1-min interval) |
| Brand | MagQu |
|---|---|
| Origin | Taiwan |
| Model | XacQuan |
| Frequency Range | 10 Hz – 25 kHz |
| Output | Real (χ′) and Imaginary (χ″) Components of AC Susceptibility |
| Sample Volume | ≥ 0.1 mL |
| Measurement Time | < 60 s per sample |
| Compliance | CE-marked, RoHS-compliant |
| Software Interface | Windows-based GUI with real-time plotting and data export (CSV, TXT) |
| Brand | Mahr |
|---|---|
| Origin | Germany |
| Model | Digimar 817 CLM / 816 CL |
| Measurement Principle | Dual-Head Optical Encoder-Based Linear Displacement Metrology |
| Motion System | Air-Bearing Guided Motorized Carriage |
| Guide Rail Material | Stainless Steel |
| Positioning Repeatability | ≤ ±0.3 µm (typical, per ISO 230-2) |
| Temperature Compensation | Integrated Pt100 Sensor with Real-Time Linear Expansion Correction |
| Display | Backlit Graphic LCD with Icon-Based Menu Navigation |
| Data Interface | RS232 (Opto-Isolated), USB 2.0 |
| Power Supply | Rechargeable Li-ion Battery (≥8 h continuous operation) |
| Zero Setting | User-Defined Reference Point on Workpiece |
| Compliance | Designed to Support ISO/IEC 17025 Calibration Traceability Requirements |
| Software Upgrade Path | Field-Programmable Firmware via USB |
| Brand | Mahr |
|---|---|
| Origin | Germany |
| Model | MarSurf LD 130 Series |
| Measurement Principle | Stylus-based profilometry |
| Probe Type | Contact stylus |
| Max. Measuring Length | 130 mm (with 100 mm stylus) / 260 mm (with 200 mm stylus) |
| Vertical Travel | 13 mm / 26 mm |
| Vertical Resolution | Sub-nanometer |
| Residual Noise | <20 nm Rz |
| Probe Exchange | Magnetic quick-lock system |
| Structural Design | Modular architecture |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | MAT |
| Price | Upon Request |
| Measurement Range | ±1.2 mm |
| Optical Magnification | 34× |
| Accuracy | 5 µm at 3 m, 50 µm at 30 m |
| Maximum Effective Measurement Distance | 30 m (extendable) |
| Linear Measurement Accuracy | ±20 µm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB50 |
| Instrument Type | Moisture Analyzer |
| Maximum Weighing Capacity | 50 g |
| Readability | 1 mg |
| Moisture Content Accuracy | ±0.01% |
| Repeatability (2 g sample) | ±0.05% |
| Repeatability (10 g sample) | ±0.015% |
| Drying Temperature Range | Up to 160 °C (optional 250 °C) |
| Maximum Drying Time | 9 h 59 min |
| Temperature Setting Increment | 1 °C |
| Sample Pan Diameter | 100 mm |
| Display | Large Backlit LCD with AEP (Advanced Eye Protection) |
| Interface | RS232C |
| Operating Ambient Temperature | −10 °C to +40 °C |
| Power Supply | 230 V, 50 Hz |
| Predefined Programs | 99 |
| Drying Modes | Standard, Rapid, Multi-Step, Moderate |
| Auto-Off Modes | Manual, Automatic, Timed |
| Optional Features | Sample ID Tagging, Drying Curve Export |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC003-ML Series |
| Pricing | Available Upon Request |
| Measurement Range (X×Y×Z) | 1000×2000×1000 mm to 1500×3500×1200 mm |
| MPE (E₀) | 3.0 + L/250 µm to 4.2 + L/200 µm |
| Probe Error (PFTU) | 3.8–5.0 µm |
| Structural Design | Single-Side High-Frame Moving Bridge |
| Guide Material | Granite (all three axes) |
| Bearing Type | Self-Cleaning Preloaded Air Bearings |
| Drive System | Imported DC Servo Motors & Friction Rod Transmission |
| Z-Axis Counterbalance | Pneumatic Cylinder Balancing |
| Control System | German SB High-Integration CNC Controller |
| Software | AC-DMIS Metrology Suite (Proprietary, ISO 10360-2 Compliant) |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MC012-XZ-150 |
| Motion System | Air-bearing Z-axis & Precision Linear Stage |
| Vertical Resolution | 1/65536 (equivalent to ≤0.03 µm typical interpolation resolution) |
| Vertical Range | 6 mm (extendable) |
| Horizontal Travel (X) | 150 mm |
| Z-axis Linearity Error | ≤0.2 µm over 80 mm |
| X-axis Encoder Accuracy | ≤5 µm over 150 mm |
| Workpiece Capacity | Ø1–100 mm shafts, up to Ø200 mm rings, max length 140 mm |
| Traverse Speed | 0.2–0.4 mm/s (3-step mechanical speed control) |
| Power Supply | 220 V, 50 Hz, 0.5 kW |
| Pneumatic Requirement | Clean, dry air ≥0.5 MPa |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MC012-XZ-150G |
| Quotation | Upon Request |
| Z-Axis Linear Motion Accuracy | ≤0.2 µm / 100 mm |
| X-Axis Grating Resolution | ≤3 µm / 150 mm |
| Sensor Range | 6 mm (expandable) |
| Maximum Workpiece Diameter | Ø100 mm (shaft), Ø200 mm (sleeve) |
| Effective Measurement Length | 140 mm |
| Air Bearing Stage | Closed-type Pneumatic Float |
| Traverse Speed | 0.2–0.4 mm/s (3-step mechanical speed control) |
| Power Supply | 220 V, 50 Hz, 0.5 kW |
| Clean Air Requirement | ≥0.5 MPa |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MC012-XZ-230 |
| Motion Platform | Precision Air-Bearing Stage (Open-Type) |
| Vertical (Z) Motion Accuracy | ≤0.2 µm / 100 mm |
| Horizontal (X) Positioning Accuracy (via Linear Encoder) | ≤5 µm / 220 mm |
| Sensor Range | 12 mm |
| Resolution | 1/65536 steps |
| Measurable Shaft Diameter | Φ1–180 mm |
| Max Workpiece Outer Diameter | ≤Φ200 mm |
| Max Measurable Length | 200 mm |
| Traverse Speed | 0.05–0.4 mm/s (4-step microcomputer-controlled speed regulation) |
| Power Supply | 220 V, 50 Hz, 0.5 kW |
| Pneumatic Supply | Clean, oil-free air ≥0.5 MPa |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MC012-Y9025B |
| Spindle Accuracy | ±0.0125 µm |
| System Accuracy | 0.03 µm |
| Data Acquisition | Hall-effect Sensor |
| Max. External Diameter | Ø140 mm (expandable) |
| Min. Internal Diameter | Ø3 mm |
| Max. Measurement Height | 300 mm (extendable) |
| Radial Range | ≤30 µm |
| Sensor Resolution | 0.01 µm |
| Max. Load Capacity | 15 kg |
| Rotational Speed | 115 rpm |
| Power Supply | 220 V, 50 Hz, 250 W |
| Air Supply Pressure | ≥0.45 MPa |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MC012-Y9025C |
| Spindle Accuracy | ±0.025 µm |
| System Accuracy | 0.06 µm |
| Data Acquisition | Hall-effect Sensor |
| Max. External Diameter | Ø140 mm (expandable) |
| Min. Internal Diameter | Ø3 mm |
| Max. Measurement Height | 200 mm (extendable) |
| Radial Range | ≤30 µm |
| Sensor Resolution | 0.01 µm |
| Max. Load Capacity | 10 kg |
| Rotational Speed | 115 rpm |
| Power Supply | 220 V, 50 Hz, 250 W |
| Air Pressure Requirement | ≥0.45 MPa |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MC012-Y9025DG |
| Spindle Radial Error | ±0.0125 µm |
| System Accuracy | 0.03 µm |
| Max. External Diameter | Ø200 mm (expandable) |
| Min. Internal Diameter | Ø3 mm |
| Max. Measurement Height | 300 mm (extendable) |
| Range | ≤400 µm (radial deviation) |
| Sensor Resolution | 0.01 µm |
| Max. Load Capacity | 15 kg |
| Rotational Speed | 6 rpm |
| Power Supply | 220 V, 50 Hz, 250 W |
| Air Supply Pressure | ≥0.45 MPa |
| Encoder | Imported HEIDENHAIN precision rotary encoder |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MC012-Y9025E |
| Spindle Accuracy | ±0.018 µm |
| System Accuracy | 0.045 µm |
| Data Acquisition | Hall-effect Sensor |
| Max. External Diameter | Ø300 mm (standard Ø140 mm, optional extensions to Ø200/Ø250/Ø300 mm) |
| Min. Internal Diameter | Ø3 mm |
| Max. Measurement Height | 300 mm (extendable) |
| Radial Range | ≤30 µm |
| Sensor Resolution | 0.01 µm |
| Max. Load Capacity | 10 kg |
| Spindle Speed | 115 rpm |
| Power Supply | 220 V, 50 Hz, 250 W |
| Air Pressure Requirement | ≥0.45 MPa |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MC012-Y9030D |
| Maximum Load Capacity | 40 kg |
| Spindle Radial Error | ±0.04 µm |
| System Accuracy | 0.1 µm |
| Data Encoder | HEIDENHAIN Precision Rotary Encoder |
| Max External Diameter | Ø300 mm (extendable to Ø400 mm) |
| Min Internal Diameter | Ø3 mm |
| Max Measurement Height | 300 mm (extendable to 600 mm) |
| Range | ≤400 µm (radial deviation) |
| Sensor Resolution | 0.01 µm |
| Rotational Speed | 6 rpm |
| Power Supply | 220 V, 50 Hz, 250 W |
| Air Supply Pressure | ≥0.45 MPa |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME-288B |
| Pricing | Upon Request |
| Brand | MEAS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | D-Series |
| Pricing | Upon Request |
| IP Rating | IP67 |
| Output Options | Analog (0–5 V / 4–20 mA), Digital (RS232/RS485), Switch Output |
| Measurement Ranges | ±5°, ±15°, ±30° |
| Resolution | 0.001° |
| Accuracy (Digital/Analog, typical at 25°C) | ±0.04° |
| Accuracy (Digital/Analog, full temp range −40°C to +85°C) | ±0.15° (±0.3° for ±15° range, ±0.8° for ±30° range) |
| Temperature Drift | 0.06% FS/°C |
| Bandwidth | 23 Hz |
| Noise Density | 0.001° RMS |
| Supply Voltage | 10–30 VDC |
| Supply Current | 30–40 mA |
| Operating Temperature | −40°C to +85°C |
| Storage Temperature | −40°C to +85°C |
| Dimensions (W × D × H) | 84 × 70 × 46 mm |
| Weight | 290 g |
| EMC Compliance | EN 61000-6-2 / EN 61000-6-4 |
| Shock & Vibration | MIL-STD-810G compliant |
| Certifications | CE, RoHS |
| Brand | Mechanical Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Max TC |
| Measurement Method | Contact-Based |
| Temperature Range | -60°C to +175°C |
| Cooling Power | 52 W @ -40°C, ~200 W @ 0°C |
| Thermal Ramp Performance | 25°C → -40°C in < 2 min |
| Temperature Stability | ±0.1°C at high-temperature setpoints |
| Power Supply | Standard AC outlet (100–240 VAC, 50/60 Hz) |
| Environmental Compliance | Compressor-free operation, frost-free control, no compressed air or cryogenic fluids required |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | INE700 |
| Pricing | Upon Request |
| Brand | MesaLabs |
|---|---|
| Origin | USA |
| Model | Defender 510 |
| Flow Range | L: 5–500 mL/min, M: 50–5,000 mL/min, H: 300–30,000 mL/min |
| Volume Flow Accuracy | ±1% of reading |
| Volume Units | mL/min, L/min, cc/min, cf/min |
| Calibration | NIST-traceable, ISO/IEC 17025 accredited (NVLAP Lab Code 200661-0) |
| Interface | RS-232 |
| Software | DryCal Pro |
| Compliance | OSHA Technical Manual referenced method for personal sampling pump calibration |
| Brand | MesaLabs |
|---|---|
| Origin | USA |
| Model | Defender 520 |
| Flow Principle | Positive Displacement (Dry Piston) |
| Flow Range | L: 5–500 mL/min |
| M | 50–5,000 mL/min |
| H | 300–30,000 mL/min |
| Volume Accuracy | ±1.0% of reading |
| Temperature Measurement | ±0.8 °C (typ.), ±1.3 °C (max) |
| Pressure Measurement | ±3.5 mmHg (typ.), ±7.0 mmHg (max) |
| Units | mL/min, L/min, cc/min, cf/min |
| Interface | RS-232 |
| Compliance | ISO/IEC 17025 accredited calibration, NIST-traceable, NVLAP Lab Code 200661-0 |
| Software | DryCal Pro v5.x (real-time data logging, audit trail, CSV export) |
| Application Scope | Industrial hygiene, occupational health, ambient air monitoring, personal sampling pump calibration |
| Brand | MesaLabs |
|---|---|
| Origin | USA |
| Model | Defender 530+ |
| Flow Principle | Dry Piston Volumetric Displacement |
| Calibration Traceability | NIST-traceable, ISO/IEC 17025 accredited (NVLAP Lab Code 200661-0) |
| Flow Ranges | L: 5–500 mL/min |
| M | 50–5,000 mL/min |
| H | 300–30,000 mL/min |
| Volumetric Accuracy | ±0.75% of reading |
| Standardized Flow Accuracy | ±1.0% of reading |
| Temperature Accuracy | ±0.8 °C (typical), ±1.3 °C (max) |
| Pressure Accuracy | ±3.5 mmHg (typical), ±7.0 mmHg (max) |
| Units | mL/min, L/min, cc/min, cf/min (volumetric) |
| Interface | RS-232 |
| Compliance | OSHA Technical Manual reference, GLP/GMP-ready audit trail support via DryCal Pro software |