| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HPD Handheld Powder Dispenser |
| Capacity Range | 100–200 g |
| Maximum Capacity | 100 g |
| Readability | 0.001 g (1 mg) |
| Repeatability | 1 mg |
| Instrument Type | Precision Powder Dispensing System |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ICS4_5 and ICS685 |
| Max. Platform Connections | 1 (ICS4_5), 4 (ICS685) |
| Data Storage Capacity | 100 entries (ICS4_5), 5,000 entries (ICS685) |
| Optional Alibi Memory | 300,000 entries |
| Interface Options | RS232, USB, Ethernet, optional fieldbus modules (PROFIBUS, PROFINET, EtherNet/IP) |
| Display | Full-color graphical LCD with multilingual UI support |
| Compliance | OIML R76, NTEP Class III, ISO/IEC 17025 traceable calibration |
| Software Integration | DatablCs™ database software, configurable transaction logging, FDA 21 CFR Part 11–compliant audit trail (with optional user management module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ICS4_9 |
| Protection Rating | IP68 / IP69K |
| Construction | Full AISI 304 stainless steel |
| Display | Backlit dot-matrix LCD (3 display modes, character height up to 25 mm) |
| Operating Temperature | Class III (–10 °C to +40 °C) |
| Humidity | Up to 85% RH at 40 °C |
| Power Supply | 100–240 V AC, 50–60 Hz, 300 mA |
| Optional Battery | 12 V DC / 2.5 A (up to 22 h with single load cell) |
| Interface Options | Standard – 1 x scale interface (analog / IDNet / SICSpro), 1 x RS232 |
| Load Cell Compatibility | All analog, IDNet, and SICSpro platforms (excluding F-cell, AWU, GD16-17, PIK) |
| Analog Input Spec | Impedance ≥87.5 Ω (1×350 Ω or 4×350 Ω), Excitation 3.3 V DC, Sensitivity 2–3 mV/V, Verification Scale Interval: 7,500 e (OIML/CMC certified), Internal Resolution: 300,000 d (uncertified), Temperature Coefficient: 0.264 µV/e |
| Certifications | OIML R76, NTEP, CMC, CE, CSA |
| Alibi Memory Option | 300,000 entries |
| Data Storage | 100 local records (standard), expandable via Alibi log |
| Keyboard | PET-based membrane keypad (>1,000,000 actuations) |
| Language Support | English, German, French, Italian, Spanish, Simplified Chinese, Portuguese, Japanese |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ICS689 |
| Protection Rating | IP68/IP69K |
| Construction | Full AISI 304 Stainless Steel (1.4301) |
| Display | Color TFT (320×240 px), 3-line mode, 17 mm character height |
| Weighing Functions | Checkweighing, Counting, Filling, Accumulation, Statistics, Label Printing, Multi-language UI (EN/DE/FR/IT/ES/PT/ZH/JP) |
| Connectivity | Standard RS232 + Scale Interface (analog/IDNet/SICSpro) |
| Optional | Ethernet, WLAN, USB Host/Device, Digital I/O (4 in/4 out), RS422/485 |
| Sensor Support | Up to 4 load cells (strain gauge type), compatible with F-cell, AWU, GD16-17, PIK excluded |
| Internal Alibi Memory | 300,000 transactions |
| Calibration Log | Embedded |
| Certifications | OIML R76, NTEP Class III, CE, CSA C/US, GMP-compliant, EHEDG Certified, NSF/ANSI 2, CMC |
| Operating Temperature | –10 °C to +40 °C (Class III), Humidity: ≤85% RH at 40 °C |
| Power | 100–240 VAC, 50–60 Hz, 300 mA |
| Optional Battery | 12 VDC/2.5 A — 22 h (1 sensor), 18 h (4 sensors) |
| Brand | METTLER TOLEDO |
|---|---|
| Model | IND560 |
| Display | VFD Graphic Interface |
| Communication | Ethernet (RJ45), TCP/IP |
| Signal Processing | Sigma-Delta ADC with Adaptive Filtering |
| Data Storage | Battery-Backed Non-Volatile Memory |
| User Interface | SoftKey Programmable Buttons |
| Architecture | Embedded Database, Modular Application Firmware |
| Vibration Compensation | TraxDSP Technology |
| Compliance Support | GLP/GMP Audit Trail Ready, FDA 21 CFR Part 11 Compatible (via optional software configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | JE703/1203 |
| Type | Precision Balance |
| Max Capacity | 6100 g |
| Readability | 0.1 mg (JE703), 0.01 g (JE1203) |
| Repeatability | < 0.2 mg (JE703), < 10 mg (JE1203) |
| Calibration | Automatic internal (JE703-IC/JE1203-IC) or external |
| Temperature Compensation | Dynamic real-time |
| Connectivity | RS232 standard |
| Weighing Units | ct, g, oz, dwt, gn, momme, tola, baht, tael (user-selectable) |
| Pan Size | 90 mm (JE703), 160 mm (JE1203) |
| Overload Protection | Integrated mechanical and software-based |
| Filtering | Adaptive digital filtering with multiple stability levels |
| Power | AC adapter or rechargeable battery (JE1203 portable variant) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | JE703/1203 |
| Capacity | 70.3 g / 120.3 g |
| Readability | 0.1 mg (JE703), 0.1 mg (JE1203) |
| Repeatability | ≤0.2 mg |
| Linearity | ≤0.4 mg |
| Pan Size | Ø90 mm |
| Calibration | Internal (IC) or External |
| Compliance | ISO/IEC 17025, ASTM E899, USP <41>, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | LA Series |
| Maximum Capacity | 82 g to 4200 g |
| Readability | 0.1 mg to 10 mg |
| Repeatability (5% load) | 0.1 mg / 1 mg / 10 mg (typical: 0.08 mg / 0.7 mg / 7 mg) |
| Linearity Error | 0.2 mg / 2 mg / 20 mg (typical: 0.08 mg / 0.6 mg / 6 mg) |
| Minimum Weight (USP, ±0.10%) | 160 mg / 1.4 g / 14 g |
| Minimum Weight (±1%) | 16 mg / 0.14 g / 1.4 g |
| Stabilization Time | 3 s |
| Dimensions (W × D × H) | 210 × 308 × 345 mm (LA84E–LA4002E) |
| Pan Diameter | 80 mm / 100 mm / 180 mm |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Interface | RS232, optional Bluetooth |
| Software | MT-SICS, EasyDirect™ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LA204/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Accuracy (Linearity) | ±0.2 mg |
| Repeatability | ≤0.08 mg |
| Calibration | Internal motorized calibration with built-in weights |
| Weighing Units | g, mg, kg, oz, ct, etc. |
| Draft Shield | Integrated glass draft shield |
| Compliance | Designed to support GLP/GMP documentation requirements and ISO/IEC 17025-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Model | LE104E |
| Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Calibration | External |
| Pan Diameter | 80 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Model | LE2002E |
| Type | Analytical Balance |
| Max Capacity | 2200.0 g |
| Readability | 0.01 g |
| Accuracy | ±0.02 g |
| Repeatability | ±0.01 g |
| Calibration | External |
| Pan Size | 180.0 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-sourced) |
| Model | LE203E |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 1.0 mg |
| Calibration Method | External |
| Pan Diameter | 100 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LE3002E |
| Type | Precision Balance |
| Max Capacity | 3200.0 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Pan Size | 180.0 mm |
| Power Supply | AC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LE303E |
| Maximum Capacity | 320 g |
| Readability | 1.0 mg |
| Repeatability | 1.0 mg |
| Calibration | External |
| Weighing Pan Diameter | 100 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LE4002E |
| Type | Precision Balance |
| Max Capacity | 4200.0 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Pan Size | 180.0 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | LE403E |
| Instrument Type | Precision Balance |
| Maximum Capacity | 420 g |
| Readability | 1.0 mg |
| Repeatability | 1.0 mg |
| Calibration Method | External |
| Weighing Pan Diameter | 100.0 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MA |
| Type | Compact Laboratory Balance |
| Readability | 10 mg / 10 mg / 100 mg (depending on variant) |
| Max Capacity | 620 g / 2.2 kg / 6.2 kg |
| Repeatability (5% load) | 7 mg / 7 mg / 70 mg (typical) |
| Linearity Error | 6 mg / 6 mg / 60 mg (typical) |
| Sensitivity Drift (nominal load) | 25 mg / 50 mg / 250 mg (typical) |
| Minimum Weight (USP <0.10% tolerance) | 14 g / 14 g / 140 g |
| Stabilization Time | 1.5 s / 1.5 s / 1 s |
| Dimensions (W × D × H) | 177 × 253 × 74 mm |
| Pan Size | 160 × 160 mm |
| Power Options | AC adapter or rechargeable battery |
| Display | High-contrast LCD with intuitive icon-based interface |
| Calibration | Internal motorized calibration with built-in test weights |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MA Precision Balance |
| Measurement Principle | Electromagnetic Force Compensation (EMFC) |
| Readability | 1 mg to 1 g |
| Max Capacity | 120 g to 32.2 kg |
| Repeatability (5% load) | 0.7 mg to 400 mg |
| Linearity | 0.6 mg to 100 mg |
| Minimum Weight (USP, ±0.10%) | 1.4 g to 820 g |
| Stabilization Time | 1.0 s to 1.5 s |
| Calibration | Internal motorized calibration with built-in weights (certified versions) |
| Compliance | OIML R76, NTEP Class II/III, ISO/IEC 17025 support, USP <41> & <1251> compliant |
| Interface | USB-A, RS232, optional Bluetooth |
| Display | Full-color LCD touchscreen |
| Construction | Die-cast metal base, PBT top housing, QuickLock draft shield |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MA Series (including MA55, MA95, MA155DU, MA54, MA104, MA204) |
| Maximum Capacity | 52 g to 220 g |
| Readability | 0.01 mg to 0.1 mg |
| Repeatability (at 5% load) | 0.015–0.1 mg |
| Linearity Error | 0.03–0.2 mg |
| Sensitivity Shift (nominal load) | 0.15–0.8 mg |
| Minimum Weight (USP <0.10%) | 30–160 mg |
| Stabilization Time | 2–4 s |
| Dimensions (W × D × H) | 209 × 354 × 354 mm |
| Pan Diameter | 80–90 mm |
| Sensor Technology | Electromagnetic Force Compensation (EMFC) |
| Calibration | Internal motorized calibration with built-in weights (standard) |
| Compliance | OIML R76, NTEP Class I, ISO/IEC 17025-ready |
| Interfaces | USB-A, RS232, optional Bluetooth |
| Software | MT-SICS, EasyDirect™ Balance Software |
| Environmental Protection | QuickLock draft shield, overload protection, PBT top housing, metal base |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA1002 |
| Capacity | 1000 g |
| Readability | 1 mg |
| Repeatability | ±0.8 mg |
| Linearity | ±1.5 mg |
| Calibration | Internal automatic calibration with built-in test weight |
| Display | High-brightness LCD with graphical user interface |
| Interface | USB-A, RS232 |
| Operating Temperature | 10–30 °C |
| Weighing Pan Size | 120 mm diameter stainless steel |
| Dimensions (W×D×H) | 210 × 320 × 325 mm |
| Weight | 4.5 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA103 Precision Balance |
| Maximum Capacity | 103 g |
| Readability | 1 mg |
| Repeatability | ±0.001 g |
| Calibration | Internal automatic calibration with built-in test weight |
| Display | High-contrast LCD with backlight |
| Interface | USB-A, RS232 |
| Dimensions (W × D × H) | 190 × 330 × 90 mm |
| Net Weight | ~2.5 kg |
| Compliance | ISO/IEC 17025, GLP/GMP-ready, FDA 21 CFR Part 11 compatible (via optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MA104 Analytical Balance |
| Price | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA12001L Precision Balance |
| Display | High-brightness LCD with on-screen guidance |
| Interface | USB-A, RS232 |
| Calibration | Internal motorized calibration with built-in test weights |
| Construction | Robust housing with scratch-resistant glass draft shield and stainless-steel pan |
| Compliance | Designed to support GLP/GMP documentation workflows |
| Data Management | Supports direct printout, PC transfer, and USB storage export |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA155DU Analytical Balance |
| Readability | 0.1 mg |
| Capacity | 155 g |
| Calibration | Internal automatic calibration with built-in test weight |
| Display | High-contrast LCD with graphical user interface |
| Interface | USB-A, RS232 |
| Compliance | ISO/IEC 17025, GLP/GMP-ready, FDA 21 CFR Part 11 compatible (with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MA155DU/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 62 g / 152 g |
| Readability | 0.01 mg / 0.1 mg |
| Repeatability (typ.) | 0.015 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 30 mg |
| Stabilization Time | 4 s |
| Pan Diameter | 80 mm |
| Dimensions (H×W×D) | 354 mm × 209 mm × 354 mm |
| Verification Scale Interval | 1 mg |
| Display | LCD Hybrid Touchscreen |
| Interfaces | RS232, USB-A, Bluetooth (optional) |
| Compliance | Legal-for-Trade certified, GLP/GMP-ready, USP <41> compliant |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA16001L Precision Balance |
| Display | High-brightness LCD with on-screen guidance |
| Interface | USB-A, RS232 |
| Calibration | Internal test weight–driven automatic calibration |
| Construction | Robust housing with scratch-resistant glass draft shield and chemical-resistant keypad |
| Compliance | Designed to support GLP/GMP documentation workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA2002 Precision Balance |
| Maximum Capacity | 2,000 g |
| Readability | 0.01 g |
| Calibration | Internal automatic calibration with built-in test weight |
| Display | High-brightness LCD with graphical user interface |
| Interface | USB-A, RS232 |
| Compliance | ISO/IEC 17025, GLP/GMP-ready, FDA 21 CFR Part 11 compatible (via optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA2002P Compact Laboratory Balance |
| Power Options | AC adapter or rechargeable battery |
| Display | High-contrast LCD with backlight |
| Interface | Touch-sensitive keys |
| Calibration | Internal motorized calibration with built-in test weight |
| Construction | Scratch-resistant glass top plate, reinforced polymer housing |
| Compliance | ISO/IEC 17025-compatible operation, GLP/GMP-ready data logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MA203 Precision Balance |
| Capacity | 210 g |
| Readability | 1 mg |
| Repeatability | ±0.001 g |
| Calibration | Internal automatic calibration with built-in test weight |
| Display | High-contrast LCD with backlight |
| Interface | USB-A, RS232 |
| Compliance | ISO/IEC 17025, GLP/GMP-compliant data handling, FDA 21 CFR Part 11 ready (with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MA204 Analytical Balance |
| Price | Upon Request |