| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | PUA589lift |
| Capacity Options | 300 kg, 600 kg, 1500 kg |
| Accuracy Class | III |
| Verification Scale Interval (e) | 0.2 kg (for 600 kg), 0.5 kg (for 1500 kg) |
| Platform Dimensions (W × L) | 0.8 × 0.8 m, 1.0 × 1.0 m, 1.25 × 1.25 m, 1.25 × 1.5 m |
| Platform Height Above Floor | 60 mm |
| Incline Angle | 8.7° |
| IP Rating | IP68 |
| Platform & Ramp Material | AISI 304 Stainless Steel |
| Operating Temperature Range | −10 °C to +40 °C |
| Safety Load | 800 kg / 2000 kg / 4000 kg (model-dependent) |
| Load Transmission | Patented Rocker Foot Mechanism |
| Surface Finish | Bead-blasted stainless steel |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | QB5 |
| Max Capacity | 81 g / 220 g |
| Readability | 0.005 mg / 0.01 mg |
| Repeatability (sd) | 0.005 mg |
| Minimum Weight (USP <41>) | 10 mg |
| Minimum Weight (1%, 2sd) | 1 mg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Quantos QA |
| Maximum Capacity | 100 g |
| Readability | 0.1 mg |
| Repeatability | 1 mg |
| Liquid Dispensing Range | 1 mg to several grams |
| Compliance | Designed for GLP/GMP environments with full audit trail support |
| Integration | Compatible with XP/XPE analytical balances and QWB workflow software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Quantos QB |
| Maximum Capacity | 100 g |
| Readability | 0.1 mg, 0.01 mg, 5 µg, 1 µg |
| Repeatability | 1 mg |
| Compliance | Designed for GLP/GMP environments, compatible with FDA 21 CFR Part 11–enabled software workflows |
| Integration | Modular upgrade for XP/XPE analytical balances |
| Application Scope | Gravimetric preparation of standards, stock solutions, multi-component reference materials, and final concentration dilutions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SCS/ZCS/PDX |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model Series | SCS, ZCS, ZCU, SCU |
| Pricing | Available Upon Request |
| Explosion Protection | ATEX / IECEx Certified Configurations Available |
| Load Capacity Range | 30–150 t (typical) |
| Accuracy Class | OIML R76-1 Class C3 or C4 |
| IP Rating | IP68 (load cells), IP65 (junction boxes & indicators) |
| Operating Temperature | –30 °C to +70 °C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Seven2Go (S2, S3, S4, SG23, S7, S8, S9) and SevenGo Duo (SG68, SG78, SG98) |
| Measurement Parameters | pH / mV / Ion Concentration / Conductivity / TDS / Resistivity / Salinity / Dissolved Oxygen / Atmospheric Pressure / Temperature |
| Temperature Compensation Modes | Linear, Non-linear, Pure Water |
| Calibration Points | up to 5 (pH), up to 25 (Conductivity), up to 5 (Dissolved Oxygen) |
| Buffer/Standard Sets | 4 (pH), 3 (Conductivity), 4 (Dissolved Oxygen), 138–666 µS/cm custom ranges |
| Electrode Constant Input | Manual or Automatic (via ISM) |
| Endpoint Detection | Auto or Manual |
| Interval Measurement | Configurable |
| Display | Backlit LCD |
| Connectivity | Infrared (IR), micro-USB |
| Data Storage | 200–2000 GLP-compliant records (model-dependent) |
| Protection Rating | IP67 |
| Power Supply | 4× AA alkaline or NiMH batteries |
| Language Support | Up to 12 languages |
| Compliance | GLP, ISO/IEC 17025-aligned data integrity, FDA 21 CFR Part 11-ready (with optional software and audit trail configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SQC-XP Software Application |
| Pricing | Available Upon Request |
| Compatibility | All XP Series Balances (Readability from 1 µg to 64 kg) |
| Sample Management Capacity | Up to 100 Samples |
| Tolerance Systems | EU Regulatory Standards (e.g., Food & Cosmetics), European Pharmacopoeia (Pharma), Three Customizable Tolerance Sets, Dual-Regulatory Compliance Mode |
| Interface | Native Integration with XP Balance Color Touchscreen |
| Data Capture | Fully Automated, Audit-Trail Enabled |
| Training | Unified Workflow Across XP Platform |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | WMC / PDX / FWC |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | XG 300/6 |
| Throughput | Up to 120 pcs/min |
| Max. Product Weight | 300 g |
| Max. Product Length | 250 mm |
| Standard Weight Zones | 6 (expandable to 12) |
| IP Rating | IP65 |
| Construction | Stainless Steel Frame + Food-Grade Polyoxymethylene (POM) Conveyor Belt |
| Interface | RS232 (compatible with METTLER TOLEDO Garvens checkweighers) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XP Micro Balance |
| Readability | down to 0.001 mg |
| Repeatability (sd) | as low as 0.002 mg |
| Linearity error | ≤ 0.006 mg |
| Typical stabilization time | 3.5 s |
| Pan dimensions | 40 × 40 mm |
| Compliance | GWP® Excellence, USP <41>/<1251>, ISO/IEC 17025, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Range | XP105DR, XP205, XP205DR, XP204, XP504, XP504DR |
| Maximum Capacity | 31 g / 120 g to 101 g / 520 g |
| Readability | 0.01 mg to 1 mg |
| Repeatability (sd) | 0.015 mg – 0.6 mg |
| Linearity Error | 0.1 mg – 0.5 mg |
| Eccentricity Error | 0.2 mg – 0.5 mg |
| Sensitivity Drift | 2 × 10⁻⁶ to 4 × 10⁻⁶ × Rnt |
| Temperature Coefficient of Sensitivity | 1 × 10⁻⁶ /°C × Rnt |
| Stability | 1 × 10⁻⁶ /a × Rnt |
| Typical Stabilization Time | 1.5 s – 2.5 s |
| Six Preloaded Applications | Weighing, Counting, Percentage, Density, Statistics, Formulation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Variants | XP26 / XP56 / XP26DR / XP56DR / XP6 / XP2U / XP6U |
| Maximum Capacity | 2 g – 5 g |
| Readability | 0.000001 g (1 µg) |
| Repeatability | ≤ ±0.001 mg |
| Calibration | Fully Automatic proFACT Technology (Temperature- and Time-Triggered Internal Calibration) |
| Compliance | GxP, USP <41>, USP <1251>, ISO/IEC 17025, GLP/GMP Audit Trail Ready |
| Sample Pan | SmartGrid Mesh Pan (XP26/XP56 only) |
| Interface | RS232 Standard + Modular Communication Slot (Bluetooth / Ethernet / LocalCAN / PS/2 Optional) |
| Display | 4.3″ TFT Color Touchscreen with SmartScreen UI |
| Environmental Monitoring | LevelControl Auto-Leveling Alert System |
| Regulatory Features | MinWeigh Function (GWP® Verified), BalanceCheck Prompt, GWP® Excellence Integrated Risk Management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Imported Precision Weighing System for Pipette Performance Verification |
| Model Range | XP26PC (Single-Channel), MCP1-S (Modular Single/Multi-Channel), MCP Workstation |
| Compliance | ISO 8655, JJG 646–2006 |
| Software | Calibry v3.x (FDA 21 CFR Part 11 compliant) |
| Key Specifications | XP26PC — Max Capacity 22 g, Readability 0.001 mg, Standard Uncertainty 0.0015 mg, Minimum Test Volume 1 µL, Draft Shield with Evaporation Trap, Stabilization Time 3.5 s, Dimensions 487 × 263 × 296 mm, Weight 11 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPE Micro Analytical Balance |
| Maximum Capacity | 100 g |
| Readability | 0.001 mg (1 µg) |
| Minimum Weight (USP <41>) | 1.4 mg (typical) |
| Repeatability | ≤ ±0.001 g (≤ ±1 mg) |
| Internal Calibration | Automatic, motorized |
| Weighing Pan | SmartGrid™ grid design with ErgoClip™ sample handling accessories |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (Manufactured in global production network, including China) |
| Model Variants | XPE10001L / XPE10001S / XPE10002S / XPE1202S / XPE1203S |
| Instrument Type | Precision Balance |
| Maximum Capacity | 64 kg |
| Readability | 0.001 g (1 mg) |
| Repeatability | 40 mg |
| Calibration | Internal Automatic Calibration (FACT) |
| Protection Rating | IP54 |
| Sensor Technology | Monobloc HighSpeed electromagnetic force compensation sensor |
| Pan Design | SmartPan™ with integrated spill tray |
| Compliance Features | StatusLight™ status indicator, SmartSens™ infrared interface, ErgoStand™ adjustable height stand |
| Software Integration | LabX® PC-based laboratory software (optional), built-in SOP guidance on touchscreen |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Variants | XPE10001L / XPE10001S / XPE10002S / XPE1202S / XPE1203S |
| Maximum Capacity | 64 kg |
| Readability | 0.001 g |
| Repeatability | 40 mg |
| Calibration | Internal AutoCal™ |
| Ingress Protection | IP54 |
| Construction | Stainless Steel Frame with Monobloc HighSpeed Sensor |
| Compliance | Fully Supports GLP/GMP, ISO/IEC 17025, USP <41> & <1251>, FDA 21 CFR Part 11 Audit Trail Requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPE Precision Balance |
| Instrument Type | Precision Balance |
| Capacity Range | 200 g – 64.1 kg |
| Readability | 0.1 mg – 1.0 g |
| Repeatability (typ.) | 0.12 mg – 40.0 mg |
| IP Rating | IP54 |
| Sensor Technology | Monobloc HighSpeed electromagnetic force compensation sensor |
| Compliance | ISO/IEC 17025, USP <41> & <1251>, ASTM E898, GLP/GMP-ready with audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (Manufactured in global METTLER TOLEDO facilities) |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.01 mg |
| Minimum Weight (according to USP <41>) | 14 mg |
| Calibration | Fully Automatic Internal Calibration (proFACT Advanced) |
| Environmental Control | Integrated Internal Temperature Control (ITC) |
| Weighing Pan | SmartGrid™ Perforated Grid Pan with Removable Drip Tray |
| Draft Shield | Tool-free Quick-Release, Dishwasher-Safe Glass Draft Shield |
| Compliance | Designed and validated per GWP® (Good Weighing Practice), compliant with ISO/IEC 17025, USP <41>, <1251>, ASTM E898, and supports 21 CFR Part 11 data integrity requirements via LabX software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Imported Analytical Balance |
| Model | XPE105 |
| Maximum Capacity | 120.0 g |
| Readability | 0.01 mg |
| Minimum Weight (USP) | 14.0 mg |
| Repeatability | 0.015 mg |
| Calibration | Automatic |
| Static Detection & Neutralization | Integrated StaticDetect™ |
| Draft Shield Operation | SmartSens™ Infrared Sensor |
| Software Integration | LabX® Ready |
| Compliance Support | GLP/GMP, USP <41>, <1251>, FDA 21 CFR Part 11 Audit Trail Capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPE204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability (sd) | 0.07 mg (at 200 g), 0.05 mg (at 10 g) |
| Linearity | ±0.2 mg |
| Eccentric Load Error | ±0.25 mg (at 100 g) |
| Sensitivity Drift | 3 × 10⁻⁶ |
| Temperature-Induced Sensitivity Drift | 1 × 10⁻⁶ /°C |
| Interface Update Rate | 23 Hz |
| Dimensions (W × D × H) | 263 × 486.5 × 322 mm |
| Pan Size (W × D) | 76 × 73 mm |
| Calibration | Fully Automatic Internal Calibration (ProFACT) |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Analytical Balance |
| Maximum Capacity | 100 g |
| Readability | 0.01 mg (10 µg) |
| Repeatability | < ±1 mg |
| Calibration | Fully Automatic (proFACT) |
| Compliance | USP Chapter 41 & 1251, ISO/IEC 17025, GLP/GMP-ready |
| Display | Capacitive Color Touchscreen with StatusLight™ |
| Connectivity | 4× USB, 1× Ethernet (LAN) |
| Environmental Control | Active Temperature Control (ATC™), StaticDetect™ + optional ionizer, SmartGrid draft shield, LevelControl™ leveling system |
| Software Features | Built-in method storage, result notebook, MinWeigh™ warning, user permission management (multi-level), audit trail, GWP® Verification support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR Automatic Dispensing Balance |
| Maximum Capacity | >5000 g |
| Readability | 2 µg |
| Accuracy Class | Class I (ISO 9001, ISO/IEC 17025 compliant) |
| Compliance | FDA 21 CFR Part 11 ready (with LabX), GLP/GMP traceable workflows |
| Software Integration | LabX® PC software (centralized instrument & user management, audit trail, electronic signatures) |
| Sample Handling | Integrated force compensation sensor, auto-tare on ultra-low-mass containers (down to 0.1 g tare), closed-loop dispensing control |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 2.1 g |
| Readability | 0.1 µg (0.0001 mg) |
| Repeatability (5% load) | 0.2 µg (0.0002 mg) |
| Calibration | Fully Automatic (proFACT) |
| Compliance | ASTM E897, USP <41>, ISO/IEC 17025, GWP® Verified |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Ultra-micro Balance |
| Model | XPR Series (e.g., XPR2U, XPR6U, XPR10U) |
| Maximum Capacity | 2.1 g to 10.1 g |
| Readability | 0.1 µg to 1 µg |
| Repeatability (sd, 5% load) | 0.15 µg to 0.5 µg |
| Minimum Weight (USP <41> compliant) | 0.3 mg to 1.0 mg |
| Stabilization Time | <8 s to <15 s |
| Sensitivity Drift (nominal load) | 0.015 mg to 0.04 mg |
| Display | 7" full-color capacitive touchscreen |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | XPR Precision Balance |
| Readability | 0.1 mg to 1 g |
| Max Capacity | 210 g to 64,100 g |
| Compliance | USP <41>, <1251>, GxP, ISO/IEC 17025, FDA 21 CFR Part 11 (with optional software), GLP/GMP-ready |
| Calibration | proFACT automatic internal calibration with temperature/time-triggered adjustment |
| Sensor Technology | MonoBloc HighSpeed single-module electromagnetic force compensation sensor |
| Interface | RS232, Ethernet, Bluetooth, LocalCAN, PS/2 (via modular interface slot) |
| Display | TFT color touchscreen (SmartScreen) with protective polycarbonate cover |
| Smart Functions | SmartSens infrared gesture control, LevelControl real-time leveling monitoring, MinWeigh regulatory minimum weight guidance, BalanceCheck external verification prompt, GWP Excellence integrated risk-based performance assurance |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR Precision Balance |
| Instrument Type | Precision Balance |
| Maximum Capacity | 64.1 kg |
| Readability | 0.01 g (down to 0.1 mg in micro-precision variants) |
| Repeatability | 10 mg (up to 400 mg depending on model) |
| Stabilization Time | as fast as 0.8 s |
| Minimum Weight (USP <41>) | 82 mg – 820 g (model-dependent) |
| Compliance | USP <41>, ISO/IEC 17025, GLP/GMP-ready |
| Calibration | proFACT automatic time- and temperature-triggered internal calibration |
| Pan Technology | SmartPan™ Pro draft-free weighing pan (standard on most models) |
| Connectivity | 4 × USB-A, 1 × Ethernet (LAN), optional RS232 |
| Software Integration | LabX-compatible, FDA 21 CFR Part 11 compliant audit trail support via LabX |
| User Management | Multi-level role-based access control with customizable permissions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Analytical Balance |
| Model | XPR Series |
| Maximum Capacity | 52 g |
| Readability | 1 µg |
| Repeatability | 0.004 mg |
| Calibration | Automatic |
| Compliance Features | StatusLight, LevelControl, Minimum Weight Warning, GWP Approved, FDA 21 CFR Part 11–ready software integration |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured globally per model) |
| Model | XPR Series Analytical Balance |
| Max Capacity / Readability | XPR205: 220 g / 0.01 mg |
| XPR105DR | 31 g / 0.01 mg & 120 g / 0.1 mg |
| XPR205DR | 81 g / 0.01 mg & 220 g / 0.1 mg |
| XPR204 | 220 g / 0.1 mg |
| XPR504 | 520 g / 0.1 mg |
| XPR504DR | 101 g / 0.1 mg & 520 g / 1 mg |
| Calibration | proFACT automatic internal calibration with dual-mass system |
| Compliance | USP <41>, <1251>, ISO/IEC 17025, GxP (GLP/GMP), FDA 21 CFR Part 11 ready (with appropriate software configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XPR Series |
| Instrument Type | Analytical Balance |
| Weighing Range | 20–100 g |
| Maximum Capacity | 52 g |
| Readability | 1 µg |
| Accuracy Class | ISO/IEC 17025-compliant analytical grade |
| Repeatability | 0.004 mg |
| Calibration | Fully Automatic Internal Calibration & Adjustment |
| Compliance Features | GWP® Approved, StatusLight™, LevelControl®, StaticDetect™, MinWeigh™ Warning |