| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (U=1%, k=2, typ.) | 8.2 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal, fully automatic (FACT) |
| Display | 7-inch color TFT touchscreen |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| External Dimensions (H × W × D) | 292 mm × 195 mm × 456 mm |
| Certified Readability | 1 mg |
| Connectivity | RS232 (optional), USB-A, USB-B (device connection), Ethernet, Bluetooth (optional) |
| User Management | Password-protected, unlimited users, configurable permissions |
| Compliance | 21 CFR Part 11–compatible (via LabX), USP <41> compliant, GLP/GMP-ready |
| Series | XPR Essential |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Ultra-Micro Balance |
| Model | XPR3DUE/AC |
| Maximum Capacity | 3.2 g / 1.2 g |
| Readability | 0.01 mg / 0.001 mg |
| Repeatability (typ.) | 0.0008 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 1.6 mg |
| Stabilization Time | 6 s |
| Pan Dimensions (W × D) | 32 mm × 32 mm |
| Dimensions (H × W × D) | 196 mm × 195 mm × 478 mm |
| Built-in Calibration | FACT (Fully Automatic Calibration Technology) |
| Display | 7-inch color TFT touchscreen |
| Connectivity | RS232 (optional), USB-A, USB-B, Ethernet, Bluetooth (optional) |
| 21 CFR Part 11 Compliance | Yes (with LabX software) |
| User Management | Unlimited users with role-based permissions |
| Leveling Guidance | Integrated digital level indicator |
| Static Detection | Not automated |
| Minimum Weight (U=1%, k=2, typ.) | 0.16 mg |
| Certified Readability | 1 mg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR603SN |
| Maximum Capacity | 610 g |
| Readability | 1 mg |
| Repeatability | 0.5 mg |
| Calibration | Internal |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible (via LabX), ISO/IEC 17025 support |
| Sample Pan Type | SmartPan™ |
| Leveling System | LevelMatic™ |
| Connectivity | Ethernet, USB, RS232 |
| Data Integrity | LabX-integrated, audit trail enabled, electronic signature support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XPR603SN |
| Maximum Capacity | 610 g |
| Readability | 1 mg |
| Repeatability | 0.5 mg |
| Calibration | Internal |
| Pan Type | SmartPan™ |
| Compliance Features | LevelMatic™, StatusLight™, LabX™ connectivity, GLP/GMP-ready audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Micro Balance |
| Readability | 0.001 mg / 0.01 mg (dual range) |
| Max Capacity | 0.8 g / 3.1 g (dual range) |
| Repeatability (sd) | 0.0008 mg / 0.006 mg |
| Linearity Error | ±0.01 mg |
| Typical Stabilization Time | 6 s |
| Pan Diameter | Ø27 mm |
| Design | Separated weighing unit and display/control unit |
| Built-in Applications | Weighing, Statistics, Formulation, Counting, Percentage, Density, Dynamic Weighing |
| Compliance | GWP® Excellence integrated risk-based validation support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Series Micro Balance |
| Maximum Capacity | 3.1 g |
| Readability | 1 µg |
| Minimum Weight (USP) | 1.0 mg |
| Repeatability (typ.) | ≤0.8 µg |
| Operating Temperature Range | 18–25 °C |
| Environmental Stability Requirement | ±0.5 °C/h, <30% RH change/h |
| Interface Options | RS232, USB, Ethernet (optional), Bluetooth (optional) |
| Compliance | USP <41>, <1251>, ISO/IEC 17025, ASTM E898, GLP/GMP-ready with audit trail capability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Precision Balance |
| Model Series | XS |
| Sensor Technology | MonoBloc HighSpeed single-module electromagnetic force compensation sensor |
| Readability | 0.1 mg to 1 g |
| Max Capacity | 210 g to 100 kg |
| Repeatability (sd) | 0.0008 mg to 0.6 g |
| Linearity Error | 0.002 mg to 0.3 g |
| Stabilization Time | 1.2 s to 1.5 s |
| Pan Dimensions (W×D) | 127×127 mm to 280×360 mm |
| Protection Class | IP54 |
| Construction | Full-metal monocoque frame with rounded edges and seamless, flat surfaces |
| Interface Options | RS232 (standard), plus modular slot for Bluetooth, Ethernet, PS/2, LocalCAN, or MiniMettler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS Series |
| Instrument Type | Analytical Balance |
| Capacity Range | 41–220 g (dual-range and single-range variants) |
| Readability | 0.01 mg to 0.1 mg |
| Repeatability (sd) | 0.02 mg to 0.1 mg |
| Linearity Error | ≤ 0.2 mg |
| Typical Stabilization Time | 1.5–4 s |
| Pan Dimensions | 78 × 73 mm (standard) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Variants | XS203S / XS403S / XS603S / XS1003S |
| Maximum Capacity | 610 g |
| Readability | 1 mg |
| Repeatability | 1 mg |
| Linearity Error | 2 mg |
| Calibration | Internal |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E899, GLP/GMP-ready |
| Software Integration | LabX® (optional), TestManager™ (built-in) |
| Ergonomic Design | ErgoStand™ adjustable stand, SmartPan™ draft-free weighing pan |
| Environmental Robustness | Suitable for use in fume hoods and laminar flow cabinets without draft shield |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS104 |
| Type | Analytical Balance |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg (100 µg) |
| Minimum Weight (USP) | 82 mg |
| Repeatability | ≤ ±0.1 mg |
| Calibration | Internal Automatic Calibration |
| Pan Size | Grid Design with Drainable Weighing Pan |
| Dimensions (W × D × H) | 263 mm × 365 mm × 335 mm |
| Display | 4.5-inch Full-Color Touchscreen, 16 mm High Digits |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS105DU |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 41 g / 120 g |
| Readability | 0.01 mg / 0.1 mg |
| Repeatability | 0.02 mg (at 10 g) / 0.1 mg (at max capacity) |
| Linearity | ±0.2 mg |
| Eccentric Load Error | 0.3 mg |
| Sensitivity Drift | 0.0004% |
| Temperature-Induced Sensitivity Drift | 0.00015%/°C (10–30 °C) |
| Long-Term Sensitivity Stability | 0.0002%/year |
| Typical Weighing Time | 6 s |
| Interface Update Rate | 23 Hz |
| Draft Shield Height | 235 mm |
| Pan Dimensions | 78 × 73 mm |
| Dimensions (W×D×H) | 263 × 453 × 322 mm |
| Calibration | Internal, FACT-enabled (Fully Automatic Calibration Technology) |
| Compliance | OIML R 76-1 Class I, ISO/IEC 17025, USP <41>, <1251>, FDA 21 CFR Part 11 (with optional software configuration) |
| Key | Brand: METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS203S |
| Maximum Capacity | 210 g |
| Readability | 0.001 g |
| Linearity (typ.) | ±0.002 g |
| Repeatability (at 200 g) | 0.5 mg |
| Minimum Weight (USP, typ.) | 1 g |
| Stabilization Time | 1.5 s |
| Pan Dimensions (D×W) | 127 mm × 127 mm |
| Overall Dimensions (H×W×D) | 276 mm × 198 mm × 305 mm |
| Weighing Chamber | None (open design with SmartPan™) |
| Calibration | Internal, FACT (Fully Automatic Calibration Technology) |
| Compliance | ISO/IEC 17025, USP <41> & <1251>, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS4001S |
| Instrument Type | Precision Balance |
| Maximum Capacity | 4.1 kg |
| Readability | 0.1 g |
| Linearity (typ.) | ±60 mg |
| Repeatability (typ.) | 40 mg |
| Repeatability (2 kg test weight) | 80 mg |
| Minimum Weight (USP, typ.) | 82 g |
| Stabilization Time | 0.8 s |
| Calibration | Internal / FACT |
| Pan Dimensions (D×W) | 190 mm × 223 mm |
| Housing Dimensions (H×W×D) | 96 mm × 195 mm × 257 mm |
| Display Height | 16 mm digits |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XS8001S |
| Maximum Capacity | 8.1 kg |
| Readability | 0.1 g |
| Linearity (typ.) | ±0.1 g |
| Repeatability (typ.) | 40 mg |
| Repeatability (with 5 kg test weight) | 80 mg |
| Minimum Weight (USP, typ.) | 82 g |
| Stabilization Time | 1 s |
| Calibration | Internal / FACT |
| Pan Dimensions (D×W) | 190 mm × 223 mm |
| Housing Dimensions (H×W×D) | 96 mm × 194 mm × 257 mm |
| Display Digit Height | 16 mm |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSE105DU |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 41.0 g / 120.0 g (dual-range) |
| Readability | 0.01 mg / 0.1 mg (dual-resolution) |
| Minimum Weight (USP <41> typical) | 20.0 mg |
| Repeatability | 0.02 mg |
| Calibration | Internal automatic calibration with FACT (Fully Automatic Calibration Technology) |
| Construction | Swiss-engineered monolithic weighing cell, draft shield with ergonomic sliding doors, integrated level control system |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Analytical Balance |
| Model | XSR |
| Compliance | ISO/IEC 17025, USP <41>, USP <1251>, ASTM E898, GLP/GMP-ready |
| Software | LabX®-compatible, FDA 21 CFR Part 11 compliant (with optional audit trail license) |
| Weighing Range | Up to 520 g (model-dependent) |
| Readability | 0.001 mg to 0.01 mg |
| Repeatability (sd) | ≤ 0.0006 mg (typical) |
| Calibration | Internal & external, fully traceable to SI units |
| Draft Shield | Motorized automatic draft shield with SmartDoor™ logic |
| Pan Design | SmartGrid™ perforated weighing pan |
| Connectivity | USB, RS232, Ethernet, Bluetooth (optional) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSR Precision Balance |
| Instrument Type | Precision Balance |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Readability | Down to 0.1 mg–1 mg (model-dependent) |
| Repeatability | ≤ 0.0002 g (at full capacity) |
| Internal Calibration | FACT (Fully Automatic Calibration Technology) with motorized weights |
| Environmental Compensation | Built-in temperature and drift monitoring |
| Connectivity | 4× USB-A, 1× Ethernet (LAN), optional RS-232 |
| Data Security | User-level password protection, audit trail enabled, 21 CFR Part 11 compliant configuration available |
| SmartPan™ | Patented draft shield-free weighing pan design reducing air current interference |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Analytical Balance |
| Model Range | XSR105, XSR105DU, XSR205DU, XSR64, XSR104, XSR204, XSR204DR, XSR304, XSR225DU |
| Maximum Capacity | 61–320 g (full range) |
| Readability | 0.01 mg (high-resolution models) to 1 mg |
| Repeatability (sd, 5% load) | 0.008–0.04 mg |
| Stabilization Time | 1.5–3 s |
| Minimum Weight (USP <41> compliant) | 16–82 mg |
| Calibration | proFACT — fully automatic, time- and temperature-triggered internal calibration |
| Display | Full-color touchscreen with multilingual UI (including English) |
| Connectivity | 4 × USB ports, 1 × Ethernet (LAN) port |
| Environmental Control | Active Temperature Control (ATC™), LevelControl™ leveling system, SmartGrid™ draft shield grid |
| Compliance | USP <41>, GWP® Verified, GLP/GMP-ready audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XSR105 |
| Instrument Type | Precision Balance |
| Readability | 1 mg |
| Construction | Full-metal corrosion-resistant housing |
| Pan System | SmartPan™ with integrated spill containment tray |
| Draft Shield Operation | Optional — door can remain open during weighing in fume hoods or under laminar flow |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | XSR105/AC |
| Type | Analytical Balance |
| Max Capacity | 120 g |
| Readability | 0.01 mg |
| Repeatability (typ.) | 0.008 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 16 mg |
| Stabilization Time | 3 s |
| Calibration | Internal, Fully Automatic (FACT) |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| Linearity Error (typ.) | ±0.2 mg |
| Dimensions (H × W × D) | 292 mm × 195 mm × 482 mm |
| Interface Options | USB-B, RS232 (integrated/optional), USB-A, Bluetooth (optional), Ethernet (LAN) |
| Compliance | 21 CFR Part 11–ready, GLP/GMP-supportive documentation, password-protected user management, audit trail logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | XSR204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability (typ.) | 0.04 mg |
| Minimum Weight (USP <41>, 0.1% tolerance, typ.) | 82 mg |
| Stabilization Time | 1.5 s |
| Calibration | Internal (fully automatic FACT) |
| Weighing Pan Dimensions (W × D) | 78 mm × 73 mm |
| Linearity Error (typ.) | ±0.2 mg |
| Dimensions (H × W × D) | 292 mm × 195 mm × 482 mm |
| Connectivity | USB-B, RS232 (integrated/optional), USB-A, Bluetooth (optional), Ethernet (LAN) |
| Compliance | 21 CFR Part 11–ready (with LabX), GLP/GMP-supportive audit trail, password-protected user management |
| Software Compatibility | LabX™ |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SV |
| Pricing | Available Upon Request |
| Brand | Micro-Hybrid |
|---|---|
| Origin | Germany |
| Model | INC5502D |
| Measurement Range | Longitudinal (Roll): ±180° (configurable to 0°–360°) |
| Lateral (Pitch) | ±85° (configurable to 95°–265°) |
| Resolution | 0.01° |
| Sampling Rate | 200 Hz |
| Supply Voltage | 9–32 V DC |
| Protection Rating | IP67 / IP69K |
| Weight | ~120 g |
| Output Interfaces | Analog (I/U), CANopen, SAE J1939 |
| Sampling Resolution | 8-bit (EC600/EC650), 10-bit (EC700/EC750), 16-bit (EC800/EC850) |
|---|---|
| Temperature Range | –40 to +80 °C (EC700–EC850) |
| Relative Humidity Range | 5–95 %RH (EC700–EC850) |
| Temp Accuracy | ±0.2 °C (EC700–EC850), ±0.6 °C (EC600/EC650) |
| RH Accuracy | ±2 %RH (EC700–EC850), ±3 %RH (EC650) |
| Temp Resolution | 0.04–0.2 °C |
| RH Resolution | 0.1 %RH |
| Memory Capacity | 16,000–52,000 samples (multi-channel) |
| Sampling Interval | 10 s to 2 h (EC600–EC750) |
| Display | 2-digit 7-segment LCD (EC600/EC650) |
| Communication | RS-232 (EC600–EC750), Mini USB (EC800/EC850) |
| Power | ½ AA or ⅔ AA 3.6 V lithium battery |
| Battery Life | ~1.5–2 years (sampling-dependent) |
| Enclosure Rating | IP54 or IP65 |
| Compliance | CE, RoHS |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PF204plus / PF216plus |
| Pricing | Available Upon Request |
| Accuracy | ±0.5–2% of reading (ID 13–75 mm, flow velocity >0.2 m/s) |
| Pipe ID Range | PF204plus: 13–115 mm |
| PF216plus | 50–1000 mm |
| Sensor Operating Temperature | –20 °C to +135 °C (Groups A & B) |
| Output | Optically isolated 0/4–20 mA |
| pulse output | 1 pulse/sec, max 5 V |
| Velocity Range | 0.1–20 m/s |
| Display | 64 × 240 pixel graphical LCD |
| Power | Rechargeable battery (20 h typical runtime) or 110/240 VAC ±10% via PSU |
| Certifications | CE compliant |
| Enclosure | Polypropylene carry case with custom molded EPE foam insert |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PF204plus / PF216plus |
| Pricing | Available Upon Request |
| Accuracy | ±0.5–2% of reading (ID 13–75 mm, flow velocity >0.2 m/s) |
| Pipe ID Range | PF204plus: 13–115 mm |
| PF216plus | 50–1000 mm |
| Sensor Operating Temperature | –20 °C to +135 °C (Groups A & B) |
| Output | Optically isolated 0/4–20 mA |
| pulse output | 1 pulse/sec, max 5 V |
| Velocity Range | 0.1–20 m/s |
| Display | 64 × 240 pixel graphical LCD |
| Power | Rechargeable battery (20 h typical runtime) or 110/240 VAC ±10% via external PSU |
| Certifications | CE compliant |
| Enclosure | Polypropylene carrying case with custom-cut foam insert |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PF300plus |
| Price | Upon Request |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HWSK-6 |
| Channel Count | Single-channel |
| Display | Backlit LCD with Chinese UI |
| Input Sensor | Type K thermocouple |
| Temperature Range | Ambient to 1000 °C |
| Resolution | 0.1 °C |
| Temperature Accuracy | ±3 °C |
| Time Programmability | 000–999 min (1-min resolution) |
| Control Algorithm | PID |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Load Power | ≤5 kW |
| Enclosure Material | Cast iron |
| Dimensions | 330 × 290 × 120 mm (L×W×H) |
| Mounting | Benchtop fixed installation |
| Weight | ~6 kg |
| Operating Environment | 0–40 °C, RH ≤80% |
| Cold-junction Compensation | Integrated constant-current circuit |
| Programmable Ramp Profiles | Up to 15 segmented temperature/time steps |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SWK-B |
| Channel Count | Single-Channel |
| Dimensions (L×W×H) | 330 × 290 × 120 mm |
| Mounting | Fixed Benchtop Installation |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Output Voltage Range | 0–220 V (continuously adjustable) |
| Maximum Load Capacity | 5 kW |
| Control Output | Bidirectional SCR (zero-crossing switching) |
| Control Algorithm | PID with auto-tuning capability |
| Display | LED digital temperature indicator |
| Compliance | Designed for laboratory-grade thermal process control in accordance with GB/T 19001 (ISO 9001) manufacturing practices |