Measurement Instruments
Filter
Showing 1741–1770 of 2727 results
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ActiveLine |
| Pressure Range | 10⁻¹¹ to 55,000 mbar |
| Output Signal | 0–10 V analog with integrated error diagnostics |
| Interface | Integrated measurement interface |
| Mounting Options | DN 16, DN 25/40, G 1/4″ |
| Operating Temperature | +5 °C to +60 °C (varies by sensor type) |
| Sensor Types | APR (Pirani), CMR (Capacitance Manometer), TPR (Combined Pirani/Thermocouple), PKR/IKR (Cold Cathode Ionization), PBR/IMR (Hot Cathode Ionization) |
| Pressure Units | Selectable (mbar, Pa, Torr, psi, etc.) |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU |
| Software Integration | Compatible with Pfeiffer Vacuum Control Suite and third-party SCADA/PLC systems |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Calibration System Pro |
| Calibration Range | 1013 hPa to 10⁻³ hPa |
| Flange Configuration | PS A30 110 (4×DN 16 ISO-KF, 2×DN 25 ISO-KF, 1×DN 40 ISO-KF, 1×DN 40 CF) / PS A30 111 (5×DN 16 ISO-KF, 2×DN 25 ISO-KF, 2×DN 40 ISO-KF) |
| Nitrogen Pumping Speed | 67 L/s |
| Forevacuum Pump Speed (50 Hz) | 2.5 m³/h |
| Ultimate Pressure | < 1 × 10⁻⁷ hPa |
| Gas Flow Control Range | 5 × 10⁻⁶ to 1 × 10³ hPa·L/s |
| Operating Temperature | +5 °C to +40 °C (cooling-dependent) |
| Weight | 66 kg (standard configuration) |
| Dimensions (L×W×H) | 700 × 639 × 593 mm |
| Compliance | ISO 3567, DAkkS-DKD-R 6-2, EN ISO 12100, EN 60204-1, CE (2006/42/EC & 2014/30/EU) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Digiline |
| Sensor Types | CPT200 / PPT200 / RPT200 / HPT200 / MPT200 |
| Measurement Range | 5×10⁻¹⁰ to 2×10³ mbar (model-dependent) |
| Operating Temperature | +5 °C to +50 °C |
| Enclosure Rating | IP54 |
| Electrical Interface | DIN M12 connector, RS-485 serial communication (Pfeiffer protocol), no RS-232 |
| Display | Backlit graphical LCD |
| Output Options | Analog (0–10 V or 4–20 mA), dual relay switch points |
| Compliance | Designed for integration into industrial vacuum systems per DIN/ISO standards |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 251 |
| Vacuum Interface | DN 25 ISO-KF, DN 40 ISO-KF, DN 40 CF-F |
| Measurement Range | 2 × 10⁻⁹ to 0.01 hPa |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | 150 °C |
| Accuracy | ±30 % |
| Ultimate Pressure | 10,000 hPa (atmospheric withstand) |
| Weight | 700 g |
| Output Signal | 0–10 V analog |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 251 |
| Measurement Principle | Cold Cathode Ionization |
| Range | 2×10⁻⁹ – 10⁻² hPa |
| Vacuum Interface | DN 25 ISO-KF / DN 40 ISO-KF / DN 40 CF-F |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | 150 °C |
| Accuracy | ±30 % |
| Output Signal | 0–10 V analog |
| Weight | 700 g |
| Sealing | FPM (Viton®) elastomer |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | IKR 361 / IKR 362 |
| Measurement Principle | Inverted Magnetron |
| Pressure Range | 1 × 10⁻⁹ hPa |
| Vacuum Flanges | DN 25 ISO-KF, DN 40 ISO-KF, DN 40 CF-F |
| Construction | Metal Seals (No Elastomer), Dual-Chamber Design |
| Optional Variants | Corrosion-Resistant Version, Low-Field / High-Current Configurations |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ModuLine Gauge |
| Interface Options | PROFIBUS |
| Sensor Types | Capacitance Manometer (TPR series), Cold Cathode Ionization Gauge (IKR series) |
| Operating Temperature Range | –40 °C to +80 °C |
| Weight | 0.14–0.65 kg |
| Vacuum Range | 10⁻¹¹ mbar to 10³ mbar (depending on sensor module) |
| Sealing | Metal-sealed variants available |
| Radiation & EMI Resistance | Yes |
| Application Domain | Particle accelerator beamlines, UHV/XHV research systems, industrial vacuum process monitoring |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniControl |
| Measurement Principle | Vacuum Pressure Monitoring and Pump Control via RS-485 and Analog Interfaces |
| Enclosure Rating | IP20 |
| Operating Temperature | 0°C to +50°C |
| Power Supply Options | 100–240 V AC ±10%, 47–63 Hz |
| Power Consumption | 300 W (OmniControl 200) / 411 W (OmniControl 300) / 522 W (OmniControl 400) |
| Output Voltages | 24 V DC (200/300) or 48 V DC (400) |
| Max Output Current | 11.4 A (200) / 15 A (300) / 8.33 A (400) |
| Display | 3.5-inch capacitive touchscreen |
| Mounting Options | Rack-mountable, desktop, or portable configurations |
| Compliance | Designed for integration with Pfeiffer Vacuum RS-485–enabled pumps (HiPace, HiScroll, HiLobe, MVP) and digital vacuum gauges |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PBR 360, IMR 265 |
| Measurement Range | 5×10⁻¹⁰ to 1000 hPa (PBR 360) |
| Operating Temperature | 5–60 °C (PBR 360), 0–50 °C (IMR 265) |
| Bakeout Temperature | 180 °C (PBR 360), 150 °C (IMR 265) |
| Accuracy | ±10–30 % (PBR 360), ±15 % (IMR 265, 1×10⁻⁵–1 hPa) |
| Repeatability | ±2–5 % (PBR 360), ±2 % (IMR 265, 1×10⁻⁵–1×10⁻¹ hPa) |
| Output Signal | 0.774–10 V |
| Interface | DN 25/40 ISO-KF, DN 16/40 CF |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PCR 280 |
| Measurement Principle | Capacitance manometry with integrated Pirani sensor |
| Range | 5 × 10⁻⁵ to 1500 hPa |
| Vacuum Port Options | DN 16 ISO-KF, DN 16 CF-F, or custom flange |
| Operating Voltage | 15–30 V DC |
| Output Signal | 1.2–8.68 V analog |
| Bakeout Temperature | 80 °C |
| Accuracy | ±50% (5 × 10⁻⁴–1 × 10⁻³ hPa), ±15% (1 × 10⁻³–100 hPa), ±5% (100–950 hPa), ±2.5% (950–1100 hPa) |
| Ultimate Pressure | 5000 hPa (overpressure limit) |
| Weight | 120 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 251 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa |
| Vacuum Interfaces | KF 25, CF 40, KF 40 |
| Accuracy | ±30% (1×10⁻⁸ to 100 hPa) |
| Repeatability | ±5% |
| Operating Temperature | 5–55 °C |
| Bakeout Temperature | up to 150 °C |
| Power Supply | 15.0–30.0 V DC |
| Max. Power Consumption | ~2 W |
| Output Signal | 0–10.5 V analog voltage |
| Weight | ~700 g |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR 361 |
| Measurement Principle | Pirani + Cold Cathode |
| Range | 5×10⁻⁹ to 1000 hPa (calibrated for air or N₂) |
| Vacuum Port Options | KF 25, CF 40, KF 40 |
| Repeatability | ±1% of reading (1×10⁻⁸ to 100 hPa) |
| Bakeout Temperature | ≤150 °C |
| Anode Material | Molybdenum |
| Flange Material | 1.4435 stainless steel |
| Compliance | CE, RoHS, EN 61326-1 |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | PKR251 |
| Measurement Principle | Integrated Pirani and Cold Cathode Gauge |
| Range | 5×10⁻⁹ to 1000 hPa (air/N₂) |
| Vacuum Port | DN25 ISO-KF, DN40 ISO-KF, DN40 CF-F |
| Max. Absolute Pressure | 10,000 hPa (inert gases, <55 °C) |
| Accuracy | ±30% (1×10⁻⁸–100 hPa) |
| Repeatability | ±5% (1×10⁻⁸–100 hPa) |
| Output Signal | 0–10.5 V analog |
| Supply Voltage | 15.0–30.0 V DC |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPG 201 |
| Measurement Principle | Pirani (thermal conductivity) |
| Pressure Range | 1000 to 5 × 10⁻⁴ hPa |
| Vacuum Interface | KF 16 |
| Operating Temperature | 5 to 40 °C |
| Accuracy | ±30 % at 10–100 hPa |
| Display | Integrated LCD |
| Power Supply | Rechargeable battery or external stabilized DC supply |
| Weight | 0.195 kg |
| Housing Material | Corrosion-resistant stainless steel |
| Heating Option | Available for low-outgassing and UHV-compatible operation |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 270, TPR 271 |
| Measurement Principle | Thermal Conductivity (Pirani) |
| Measured Medium | Gases |
| Range | 1×10⁻⁴ to 1000 hPa (TPR 270) |
| Accuracy | ±10 % to ±30 % of reading |
| Repeatability | ±2 % |
| Operating Temperature | 5 to 60 °C |
| Bakeout Temperature | Up to 80 °C (standard), up to 250 °C (with optional high-temp flange variants) |
| Output Signal | TPR 270: 1.5–8.5 V |
| TPR 271 | 2.2–8.5 V |
| Filament Material | TPR 270: Tungsten |
| TPR 271 | Platinum or Rhodium |
| Flange Options | DN 16 ISO-KF, DN 16 CF-F, 1/8" NPT, 8-VCR |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 |
| Measurement Principle | Pirani |
| Range | 5 × 10⁻⁴ to 1000 hPa |
| Vacuum Interface | KF 16 (DN 16 ISO-KF) |
| Output Signal | 2.2–8.5 V DC |
| Supply Voltage | 14–30 V DC |
| Filament Material | Tungsten |
| Housing Material | Stainless Steel |
| Electrical Feedthrough | Glass |
| Operating Temperature | 5–60 °C |
| Bakeout Temperature | 80 °C (250 °C optional) |
| Accuracy | ±15% of reading (10⁻³–100 hPa) |
| Repeatability | ±2% of reading (10⁻³–100 hPa) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR 280 / TPR 281 |
| Measurement Range | 1.0 × 10³ hPa to 5.0 × 10⁻⁴ hPa |
| Operating Temperature | 80 °C (standard) / 250 °C (high-temp version) |
| Accuracy | ±15 % of reading |
| Burst Pressure | 1000 kPa |
| Weight | 80 g (TPR 280, standard) / 130 g (TPR 280, high-temp) / 80 g (TPR 281, corrosion-resistant) |
| Flange Options | DN 16 ISO-KF, DN 16 CF, 1/8" NPT, 8 VCR |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | TPR280 |
| Measurement Principle | Pirani thermal conductivity gauge |
| Range | 5 × 10⁻⁴ – 1000 hPa |
| Vacuum Port Options | DN16 ISO-KF, DN16 CF-R, 1/8" NPT, 8 VCR |
| Operating Temperature | 80 °C or 250 °C (depending on version) |
| Accuracy | ±15 % of reading |
| Maximum Pressure Resistance | 1000 kPa |
| Output Signal | 0–10 V analog |
| Weight | 80 g (80 °C version, DN16 ISO-KF) / 130 g (250 °C version, DN16 ISO-KF) |
| Brand | PH-Instruments |
|---|---|
| Origin | Germany |
| Model | DosiTorr SRG |
| Measurement Principle | Gas molecule adsorption/desorption-induced rotor deceleration, quantified via rotational decay rate |
| Pressure Range | 10 mbar to 5×10⁻⁷ mbar |
| Vacuum Interface | Designed for direct replacement of ionization gauges with plug-and-play electrical compatibility |
| Brand | ph-instruments |
|---|---|
| Origin | Germany |
| Model | ION Check |
| Measurement Principle | Spinning Rotor Gauge (SRG) |
| Range | 5 × 10⁻⁷ mbar to 1 × 10⁻² mbar (up to 1 mbar max) |
| Vacuum Interface | KF25 (adapters available for other standards) |
| Accuracy | ±1% of reading from 0.1 mbar to 1 × 10⁻⁶ mbar |
| Long-term Stability | <1% per year |
| Calibration Channels | Dual parallel |
| Pumping System | Oil-free turbomolecular pump + diaphragm backing pump |
| Data Interfaces | USB-C, LAN, RS-485, optional Bluetooth |
| Control Interface | 10-inch touchscreen, Windows 10, dedicated ION Check software |
| Power Supply | 230 VAC, 50 Hz, <2 A |
| Operating Temperature | 10–40 °C |
| Dimensions | 610 × 610 × 1200 mm |
| Weight | 90.8 kg |
| Brand | ph-instruments |
|---|---|
| Origin | Germany |
| Model | VIM-2 Portable Spinning Rotor Gauge |
| Measurement Principle | Momentum exchange due to gas molecule adsorption/desorption |
| Range | 10 mbar to 5×10⁻⁷ mbar |
| Vacuum Interface | USB Type-C / Bluetooth / High-density 15-pin D-sub |
| Accuracy | ±10% (10 mbar – 0.1 mbar), ±1% (0.1 mbar – 1×10⁻⁶ mbar) |
| Long-term Drift | <1% per year |
| Sensor Material | Stainless steel 1.4404 / 1.4034 |
| Operating Temperature (Electronics) | 10–40 °C |
| Sensor Max Temp (Metal Seal) | 450 °C |
| Power Supply | 18–28 VDC, Li-ion battery (>2 h operation) |
| Data Storage | 1023 internal records |
| Output | 0–10 VDC (configurable) |
| Weight | Host 1650 g, Measuring Head 750 g, Adapter 510 g |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | photoLab® 7100 VIS |
| Wavelength Range | 320–1100 nm |
| Optical Design | Dual-Beam Reference Channel |
| Light Source | Xenon Pulse Lamp |
| Display | High-Resolution Color TFT Touchscreen |
| Connectivity | USB, Ethernet, PDF Export |
| Software | SpectroLab Data Management Suite (GLP-Compliant) |
| Compliance | ISO/IEC 17025, ASTM E275, USP <857>, FDA 21 CFR Part 11 Ready |
| Brand | Pinzhichuangsi (Product Intelligence and Creativity) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PZ-2515G |
| Resolution | 0.001 mm (X/Y/Z axes) |
| Optical Zoom | 0.7×–4.5× |
| Video Magnification | 40×–400× |
| Field of View | 10.6 mm – 1.6 mm |
| Camera | 1/3″ Sony CCD (upgradeable to 1.3 MP CMOS) |
| Light Source | Adjustable LED ring light (top & bottom) |
| Stage Material | Natural granite base and stage |
| Linear Guide | Precision V-groove roller guides with non-adhesive screw sleeve mounting |
| Drive System | Servo motor-driven XYZ axes |
| Auto-focus & edge detection | Yes |
| SPC & reporting | Integrated statistical process control and Excel/Word export |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 2D2CPIV |
| Measurement Capability | Planar (2D/3D) Velocity Field |
| Operating Frequency | Low-Frequency (≤15 Hz) |
| Velocity Range | 0–1500 m/s |
| Accuracy | ±3% of reading |
| Measurement Area | ≥400 mm × 400 mm |
| Core Components | PCO edge 5.5M dual-frame camera, dual-cavity double-pulse Nd:YAG laser (532 nm), nanosecond-precision synchronization controller, PIV post-processing software suite |
| Brand | PIV View |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR PIV |
| Price Range | USD 270,000 – 405,000 (based on configuration) |
| Measurement Mode | Planar (2D) and Volumetric (3D) |
| Frame Rate | Up to 10 kHz (full resolution), >100 Hz standard operation |
| Velocity Range | 0–1000 m/s |
| Accuracy | ±3% of measured velocity magnitude |
| Measurement Area | ≥400 mm × 400 mm (2D) |
| Laser Source Options | High-repetition-rate pulsed Nd:YAG or LED-based illumination |
| Camera Resolution | Configurable up to 4 MP at 10 kHz |
| Synchronization Precision | <10 ns jitter |
| Software Platform | PIVtec ILA v5.x with GLP-compliant audit trail and metadata embedding |
| Brand | Pixsys |
|---|---|
| Origin | Italy |
| Model | ATR224 |
| Input Types | Thermocouples (K, S, R, J, T, N, B), RTDs (PT100/500/1000, Ni100, PTC1K, NTC10K), 0–10 V, 0/4–20 mA, 0–60 mV, Potentiometer (1–150 kΩ) |
| Input Resolution | 16-bit |
| Sampling Time | Programmable down to 2.1 ms (up to 470 Hz) |
| Control Outputs | 2 x Relay (2 A / 250 V AC resistive), 1 x SSR (12/24 V DC / 25 mA), 1 x Auxiliary 12/24 V DC (30 mA max for sensor excitation) |
| Digital Input | 1 x PNP |
| Communication | microUSB (MyPixsysLab PC software), NFC/RFID (MyPixsys mobile app for Android/iOS) |
| Display | 48 × 48 mm front panel, IP65-rated polycarbonate (UL94V2), housing IP20 |
| Power Supply | 24–230 V AC/DC ±15%, 50/60 Hz, 2.5 kV galvanic isolation |
| Power Consumption | 8 VA |
| Operating Environment | 0–45 °C, 35–95 % RH (non-condensing), max. 2000 m altitude |
| Dimensions | 48 × 48 × 105 mm (W×H×D) |
| Weight | ~185 g |
| Compliance | CE-marked, conforms to EN 61000-6-2 (immunity) and EN 61000-6-4 (emission), designed for industrial control environments per IEC 61000-4 series |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | PLIF-FlameMaster |
| Type | Planar Laser-Induced Fluorescence (PLIF) Diagnostic System for Quantitative Flame Imaging |
| Application Domain | Internal Combustion Engines, Gas Turbines, High-Pressure Burners, Chemical Reactors, Shock Tubes |
| Measurement Capabilities | OH*, CH*, C2* radical distribution |
| Compliance | Designed for GLP-compliant research environments |
| Interface | Engine synchronization via crank-angle encoder input |
| Software Platform | DaVis 10.5 with FlameMaster Module (supports 2D/3D reconstruction, time-resolved statistical analysis, multi-species spectral deconvolution, and FDA 21 CFR Part 11–compliant audit trail) |
| PMM | Brand |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMM 9180 |
| Price | Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | HP-050 |
| Frequency Range | 10 Hz – 5 kHz |
| Magnetic Flux Density Range | 10 nT – 40 µT |
| Dynamic Range | > 72 dB |
| Resolution | 1 nT |
| Sensitivity | 10 nT |
| Absolute Error @ 50 Hz / 200 nT / 25 °C | ±0.4 dB |
| Frequency Response (40 Hz – 1 kHz) | ±1 dB |
| Isotropy @ 50 Hz / 200 nT | ±0.3 dB |
| Electric Field Rejection | > 20 dB |
| Temperature Coefficient | 0.015 dB/°C |
| Calibration | Built-in EEPROM |
| Dimensions | 350 mm (L) × 133 mm (Ø) |
| Weight | 400 g |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | HP-33M |
| Frequency Range | 700 MHz – 3 GHz |
| Electric Field Range | 0.3 – 300 V/m |
| Overload Protection | > 600 V/m |
| Dynamic Range | > 60 dB |
| Resolution | 0.01 V/m |
| Sensitivity | 0.3 V/m |
| Absolute Accuracy @ 930 MHz (20 V/m) | ±1 dB |
| Frequency Response (900 MHz – 3 GHz) | ±1.5 dB |
| Isotropy @ 930 MHz | ±1 dB |
| H-Field Rejection | > 20 dB |
| Temperature Coefficient | 0.05 dB/°C |
| Calibration | Built-in EEPROM |
| Dimensions | 317 mm × Ø58 mm |
| Weight | 100 g |