| Brand | QNET |
|---|---|
| Origin | Germany |
| Model | P3123 |
| Detection Frequency | 5–25 MHz |
| Measurement Repeatability | ±0.2 mm |
| Channels | 4 Ultrasonic Channels |
| Enclosure Rating | IP65 |
| Application | Non-Destructive SHD Measurement for Induction-Hardened Components |
| Brand | QPT |
|---|---|
| Origin | Germany |
| Model | QPT-TS |
| Resolution | 1 nm |
| Measurement Axes | Motorized X and Z |
| Base Material | Granite |
| Motion Control | Closed-loop stepper/servo drive |
| Measurement Speed | 0.1–3 mm/s (adjustable, constant dynamic speed control) |
| Software Platform | Windows 10/7 (64-bit compatible) |
| Interface | Standard USB/Ethernet |
| Compliance | ISO 15510, ISO 6906, ISO 10587 (thread metrology), VDI/VDE 2617-10 (geometric measurement systems) |
| Data Acquisition | Absolute measurement mode, point spacing invariant under profile tilt |
| Probe Type | Non-contact optical or tactile stylus (configurable per application) |
| Workholding | Modular fixturing with automatic feature alignment |
| Positioning | Articulated tracking arm with horizontal datum referencing |
| Brand | QPT |
|---|---|
| Origin | Germany |
| Model | Smartic M |
| Measurement Principle | Contact Profilometry (Stylus-Based) |
| Measurement Method | Contact |
| Roughness Parameters | Ra, Rz (≡ Ry-JIS), Rq, Rt (≡ Rmax), Rp, Rv, R3z, R3y, Rz-JIS, Rs, Rsk, Rku, Rsm, Rmr, RPc, Rk, Rpk, Rvk, Mr1, Mr2 |
| Vertical Measurement Range | ±1500 µm |
| Vertical Resolution | 0.0001 µm |
| Filter | Gaussian (ISO 11562 compliant) |
| Sampling Lengths | 0.08 / 0.25 / 0.8 / 2.5 / 8 mm |
| Display | 7-inch color TFT touchscreen |
| Data Storage | 4,000 roughness records or 1,000 profile traces |
| Interface | USB 2.0 (data export to Excel, PDF, DXF, PNG/JPEG |
| Probe Mounting | Magnetic coupling |
| Traverse Length | 60 mm |
| Standards Compliance | ISO 4287, ISO 13565-1/2/3, DIN 4768, VDA 2007, JIS B 0601 (2001/2013), JIS B 0611, JIS B 0612, ASME B46.1, ISO 12085, ISO 11562 |
| Brand | -- |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QA-3000 |
| Price | Upon Request |
| Input Range | ±60 g |
| Bias | <4 mg |
| One-Year Composite Repeatability | <40 µg (QA3000-030), <80 µg (QA3000-020), <125 µg (QA3000-010) |
| Temperature Sensitivity | <15 µg/°C (QA3000-030 & QA3000-020), <25 µg/°C (QA3000-010) |
| Scale Factor | 1.20–1.46 mA/g |
| Axis Misalignment | <1000 µrad (QA3000-030 & QA3000-020), <1500 µrad (QA3000-010) |
| Vibration Rectification | <10 µg/°rms (50–500 Hz), <35 µg/°rms (500–2000 Hz) |
| Intrinsic Noise | <7 µg/rms (0–10 Hz), <70 µg/rms (10–500 Hz), <1500 µg/rms (500–10,000 Hz) |
| Operating Temperature Range | –28 to +78 °C (QA3000-030), –55 to +85 °C (QA3000-020 & QA3000-010) |
| Shock Resistance | 100 g (QA3000-030), 150 g (QA3000-020 & QA3000-010) |
| Vibration Rating | 15 g peak sine (20–2000 Hz) |
| Resolution/Threshold | <1 µg |
| Bandwidth | >300 Hz |
| Thermal Modeling | Yes |
| Quiescent Current | <16 mA per supply |
| Quiescent Power | <480 mW @ ±15 VDC |
| Electrical Interface | Voltage Self-Test, Current Self-Test, Temp Sensor, –10 VDC Output, Power/Signal Ground |
| Input Voltage | ±13 to ±28 VDC |
| Weight | 7 g ±4 g |
| Diameter Below Mounting Surface | ≤1.005 in |
| Height (Bottom to Mounting Surface) | ≤0.585 in |
| Case Material | 300 Series Stainless Steel |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41003 |
| Dimensions | 12 cm (D) × 27 cm (H) |
| Weight (net) | 0.7 kg |
| Mounting | U-bolt clamp for masts up to 2 inches (50.8 mm) diameter |
| Sensor compatibility | 41003 — up to 16 mm diameter |
| Radiative error (at 1080 W/m² solar irradiance) | ≤0.4 °C RMS @ 3 m/s wind speed |
| Housing material | UV-stabilized white thermoplastic with high-reflectivity, low-thermal-conductivity disk |
| Compliance | Designed per WMO Guide to Meteorological Instruments and Methods of Observation (CIMO Guide), ISO 4690:2022 (Environmental monitoring — Performance requirements for radiation shields), ASTM D7237-21 (Standard Practice for Evaluation of Radiation Shields for Air Temperature Sensors) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342 |
| Measurement Range | −50 to +50 °C |
| Accuracy (at 0 °C) | ±0.3 °C (standard), ±0.1 °C (optional) |
| Time Constant | 42 s (with 43408 radiation shield) |
| Sensor Type | 1000 Ω Pt RTD, 4-wire configuration |
| Output Options | Resistance (41342), 0–1 VDC (41342VC), 4–20 mA (41342LC) |
| Calibration | Selectable °C or °F |
| Recommended Radiation Shield | 43502 (aspirated) or 41003P (multi-plate passive) |
| Recommended Cable | 2-pair shielded, 22 AWG (P/N 18641) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342LC |
| Output Signal | 4–20 mA |
| Measurement Range | −50 to +50 °C |
| Accuracy (at 0 °C) | ±0.3 °C (±0.1 °C optional) |
| Time Constant | 42 s (with Model 43408 radiation shield) |
| Sensor Type | 1000 Ω Pt RTD (IEC 60751 Class B, standard |
| Enclosure | Weatherproof junction box |
| Calibration | Configurable for °C or °F output scaling |
| Recommended Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate passive) |
| Cable Recommendation | 2-pair shielded, 22 AWG (e.g., Part #18641) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342VC |
| Output Signal | 0–1 VDC |
| Sensor Type | Pt1000 RTD (4-wire) |
| Measurement Range | −50 to +50 °C |
| Accuracy @ 0 °C | ±0.3 °C (standard), ±0.1 °C (optional) |
| Time Constant | 42 s (with Model 43408 radiation shield) |
| Calibration Options | °C or °F |
| Enclosure | Weatherproof terminal housing |
| Recommended Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate passive) |
| Recommended Cable | 2-pair shielded, 22 AWG (e.g., Part #18641) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41382LC2 |
| Temperature Range | -50 to +50 °C |
| Temperature Accuracy | ±0.3 °C (@ 23 °C) |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±1 %RH (@ 20 °C) |
| RH Stability | <1 %RH/year |
| RH Response Time | 10 s (unshielded) |
| Temperature Response Time | 10 s (unshielded) |
| Output Signal | 4–20 mA (2-wire loop-powered) |
| Supply Voltage | 12–30 VDC |
| Max Current Draw | 46 mA |
| Sensor Type | Pt100 RTD (temperature), Rotronic Hygromer® (humidity) |
| Enclosure Dimensions | Ø64 mm × 176 mm |
| Weight | 200 g |
| Recommended Cable | 2-pair shielded, 22 AWG |
| Optional Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41382VC |
| Temperature Range | -50 to +50 °C |
| Temperature Accuracy | ±0.3 °C @ 23 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±1 %RH @ 20 °C |
| RH Stability | <1 %RH/year |
| Response Time (with radiation shield) | 10 s |
| Output Signal | 0–1 VDC or 0–5 VDC (jumper-selectable) |
| Power Supply | 12–30 VDC |
| Operating Ambient Temperature | -50 to +50 °C |
| Dimensions | Ø64 mm × 176 mm |
| Weight | 200 g |
| Sensor Type (Temp) | Platinum RTD (Pt1000) |
| Sensor Type (RH) | Rotronic Hygromer® capacitive polymer |
| Recommended Cable | 5-conductor shielded (Young P/N 18723) |
| Optional Radiation Shields | 43502 (aspirated), 41003P (multi-layer passive) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41502 |
| Material | UV-stabilized white thermoplastic housing, anodized aluminum support frame, stainless steel mounting hardware |
| Dimensions | 20 cm (diameter) × 33 cm (height) |
| Net Weight | 1.1 kg |
| Shipping Weight | ~2.7 kg |
| Power Supply | 12–14 VDC @ 500 mA |
| Airflow Rate | 5–11 m/s (16–35 ft/s), dependent on sensor power draw |
| Radiative Error (Temperature) | ≤0.2 °C RMS at 1000 W/m² solar irradiance |
| Delta-T Error | ≤0.05 °C RMS under identical shielding exposure |
| Fan Lifetime | >80,000 hours continuous operation at 25°C |
| Sensor Compatibility | RTD-based temperature probes (e.g., 41342), combined RH/T probes (e.g., 41382) |
| Output Options | 4–20 mA or 0–1 VDC |
| Operating Environment | Outdoor, all-weather, low-wind-speed microclimates |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 50202 |
| Threshold | 1 mm |
| Accuracy | ±1 mm |
| Output Signal | 0–5.00 VDC (linear, 0–50 mm rainfall) |
| Siphon Cycle Time | ~30 s |
| Power Supply | 8–30 VDC (sensor), 48 W @ 28 VAC (heater) |
| Operating Temperature | −20 to +50 °C (with heater enabled) |
| Dimensions (w/o mounting housing) | 14 cm dia × 65 cm H |
| Collection Area | 100 cm² |
| Collector Diameter | 113 mm |
| Weight (instrument) | 2.5 kg |
| Mounting | U-bracket for mast diameter 25–50 mm |
| Features | Capacitive level sensing, thermostatically controlled heater, frost-resistant insulated housing, no moving mechanical parts |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 50203 |
| Threshold | 1 mm |
| Accuracy | ±1 mm |
| Output Signal | 0–5.00 VDC (linear, 0–50 mm rainfall) |
| Siphon Cycle Time | ~30 s |
| Power Supply (gauge only) | 8–30 VDC |
| Operating Temperature Range | –20 to +50 °C (unheated operation) |
| Dimensions (body) | 14 cm diameter × 65 cm height |
| with mounting housing | 39 cm height |
| Collection Orifice Diameter | 113 mm |
| Effective Collection Area | 100 cm² |
| Mounting | U-bracket for vertical mast (25–50 mm diameter) |
| Weight (instrument) | 2.5 kg |
| Shipping Weight | 4.0 kg |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 52202 |
| Collection Area | 200 cm² |
| Resolution | 0.01 mm |
| Accuracy | ±2% at ≤25 mm/hr, ±3% at ≤50 mm/hr |
| Operating Temperature | −20 °C to +50 °C (with heater) |
| Power Consumption | 18 W (heated mode) |
| Output | Reed Switch Closure |
| Mounting | 1″ NPT pipe thread or three-bolt flange (160 mm diameter ring) |
| Dimensions | 18 cm dia × 30 cm H (39 cm H with mounting housing) |
| Leveling | Integrated bullseye level and leveling screws |
| Optional Accessories | 52250 Bird Deterrent Kit, 52202H (220 V/50–60 Hz variant) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 52203 |
| Collection Area | 200 cm² |
| Resolution | 0.01 mm |
| Accuracy | ±2% (up to 25 mm/hr), ±3% (up to 50 mm/hr) |
| Operating Temperature | −20 °C to +50 °C |
| Output | Reed Switch |
| Mounting | 1″ NPT pipe clamp or 3-bolt flange (160 mm diameter ring) |
| Dimensions | 18 cm diameter × 30 cm height (39 cm with enclosure) |
| Power Consumption | Not applicable (non-heated) |
| Compliance | WMO-recommended design |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Radian Core |
| Price Range | ¥500,000 – ¥1,000,000 |
| Max Measurement Range | 160 m |
| Measurement Resolution | 0.08 µm |
| Spatial Accuracy | 15 µm + 5 µm/m |
| Horizontal Rotation | ±320° |
| Vertical Pitch | −59° to +79° |
| Tilt Capability | Unlimited |
| Brand | Radiant Vision Systems |
|---|---|
| Model | TrueTest™ |
| Origin | USA |
| Type | Imaging Photometer-Based AOI System |
| Compliance | CIE 1931 Standard Observer, ISO 9241-307, ASTM E308, USP <1058> (for instrument qualification), FDA 21 CFR Part 11 (software audit trail enabled) |
| Detection Capabilities | Pixel defects, line defects, Mura (JND-mapped), luminance uniformity, chromaticity uniformity, contrast ratio, gamma, and spatial nonuniformity analysis |
| Software Platform | TrueTest™ Suite v6.0+ with JND-based defect quantification engine, GLP/GMP-compliant reporting, and automated pass/fail classification |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rain-O-Matic |
| Price Range | USD 1,400 – 7,000 |
| Resolution | 0.1 mm / 0.2 mm / 0.25 mm / 0.5 mm (user-selectable) |
| Collection Area | 200 cm² (31 in²) |
| Splash Height | 290 mm (11.4 in) |
| Weight | 1300 g (45.9 oz) |
| Tipping Interval (for 300 mm tilt) | ~300 ms (σ = 7–14 ms, depending on resolution setting) |
| Filter Time Constant | ≤200 ms |
| Output | Reed switch (SPST, normally closed on pins 1–2 |
| Compliance | WMO Guide to Meteorological Instruments and Methods of Observation (WMO-No. 8), ISO 9060:2018 Class C (for precipitation measurement systems), EN 13029:2000 (rain gauge performance requirements) |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | BAROP |
| Measurement Range | 300–1100 mbar |
| Resolution | 0.2 mbar |
| Accuracy | ±1.5 mbar |
| Long-Term Stability | ±2.5 mbar per 6 months |
| Operating Temperature Range | −40 °C to +60 °C |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | EVAP |
| Housing Material | Stainless Steel & PVC |
| Measurement Range | 101–254 mm |
| Resolution | 0.25 mm |
| Accuracy | ±0.25 mm |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | H20LVL |
| Measurement Principle | Hydrostatic Pressure |
| Range | 3–200 m |
| Accuracy | ±0.1% FS |
| Output Signal | Analog (4–20 mA or 0–5 VDC) |
| Enclosure Rating | IP68 |
| Operating Temperature | −20 °C to +70 °C |
| Power Supply | 12–30 VDC |
| Material | 316 Stainless Steel Housing |
| Compliance | CE, RoHS |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | PG/H |
| Construction | Anodized aluminum housing, stainless steel components, low-surface-tension polymer tipping bucket |
| Heating | Integrated thermostatically controlled heater (activates below 1°C) |
| Switch Type | Reed switch |
| Output | Momentary closure pulse (< 0.1 s duration) |
| Resolution Options | 0.1 mm, 0.2 mm, or 0.25 mm per tip |
| Accuracy | ±0.5% at 12.5 mm/h rainfall rate |
| Dimensions | 21.9 cm diameter × 31.75 mm height |
| Compliance | Designed for continuous outdoor deployment in accordance with WMO Guide to Instruments and Methods of Observation (CIMO Guide), ISO 9060:2018 Class B performance expectations for precipitation measurement |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | Rainew |
| Measurement Resolution | 0.01 in (0.254 mm) per tip |
| Collection Orifice Diameter | 8 in (203.2 mm) |
| Display Range | 0.00–9.99 in |
| Power | Long-life alkaline battery (display unit) |
| Compliance | Meets NOAA/NWS accuracy specifications for standard precipitation measurement |
| Output | Pulse signal (1 pulse = 0.01 in) |
| Cable Options | 60 ft (Rainew 111), wireless up to 300 ft (Rainewireless) |
| Warranty | Lifetime on collector assembly |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | RainLog |
| Power Supply | 2×AAA batteries (alkaline) or optional CR2477N lithium |
| Data Logging Interval | 60 s |
| Memory | Non-volatile EEPROM |
| Storage Capacity | ≥1 year at 1-min interval |
| Rain Collector | 8-inch tipping-bucket (polypropylene body, reed switch output) |
| Resolution | 0.25 mm per tip |
| Accuracy | ±1.5% at 12.5 mm/h |
| Pulse Output | <0.1 s duration, min. pulse width 10 ms, max. input frequency 100 Hz |
| Clock Accuracy | ±1 min/month |
| Operating Temperature | −40 to +60 °C (lithium), −18 to +55 °C (alkaline) |
| Operating Humidity | 0–100% RH, non-condensing |
| Communication Interface | USB 2.0 (standard), RS-232 (legacy variant) |
| Compliance | Designed for long-term unattended field deployment in accordance with ASTM D3624 and ISO 9060:2017 Class B rain gauge performance expectations |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | RGA |
| Housing Material | Anodized Aluminum & Stainless Steel |
| Sensor Type | Tipping Bucket |
| Switch Mechanism | Reed Switch |
| Output Signal | Momentary Pulse (< 0.1 s duration) |
| Resolution Options | 0.25 mm, 0.2 mm, or 0.1 mm per tip |
| Accuracy | ±0.5% at 12.5 mm/h rainfall rate |
| Effective Orifice Diameter | 21.9 cm |
| Height | 31.75 mm |
| Integrated Level Indicator | Yes |
| Mounting Compatibility | RainWise Monopod Stand |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | RGP |
| Collection Orifice Diameter | 8 in (203.2 mm) |
| Sensor Mechanism | Magnetic Reed Switch |
| Output Signal | Momentary Pulse (< 0.1 s duration) |
| Resolution Options | 0.1 mm, 0.2 mm, or 0.25 mm per tip |
| Accuracy | ±1.5% at 12.5 mm/h rainfall intensity |
| Housing Material | Polypropylene |
| Operating Temperature Range | -40 °C to +65 °C |
| IP Rating | IP65 |
| Calibration Compliance | NWS-Recommended Standard Orifice |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | TWD |
| Temperature Range | 0–50 °C |
| Accuracy | ±0.15 °C |
| Resolution | 0.10 °C |
| Sensor Type | Precision Thermistor |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | AM4096 |
| Output Interfaces | SSI (12-bit absolute), RS422 (incremental), Analog Linear Voltage, Tacho (speed), UVW (commutation) |
| Zero Position | Infinitely reprogrammable |
| Supply Voltage | 3 V or 5 V selectable |
| Compliance | RoHS-compliant, CE-marked for industrial use |
| Operating Temperature Range | –20 °C to +70 °C |
| Package | QFN-32 |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | AxiSet™ Check-Up |
| Application | In-machine geometric performance verification of multi-axis CNC machine tools |
| Compliance | Designed for ISO 230-4 (Testing of contouring performance) and ISO 10791-6 (Test conditions for machining centres — Testing of accuracy of positioning of rotary axes) |
| Software Interface | Native integration with Fanuc, Siemens, Heidenhain, and Mitsubishi CNC macro programming environments |
| Reporting Format | Microsoft Excel®-based graphical reports with user-defined tolerance overlays |
| Data Traceability | Audit-ready timestamped records with revision history and comparative trend analysis |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | Equator™ |
| Type | Comparative Measurement System for Geometric Dimensioning and Tolerancing (GD&T) |
| Structural Principle | Parallel-Kinematic Mechanism with Kinematic Coupling |
| Measurement Method | Relative Comparison Against Master Parts Using Touch-Trigger and High-Speed Scanning Probes |
| Compliance Basis | Traceable to CMM-Calibrated Reference Parts per ISO 10360, ISO 14253, and ASME B89.4.1 |
| Software Platform | MODUS™ Equator (DMIS-compliant), MODUS™ Organiser (Operator Interface) |
| Probe System | Renishaw SP25 Micro-High-Accuracy Scanning Probe with SM25 Modular Styli Exchange |
| Thermal Compensation | Real-Time Re-Zeroing via Master Part Re-Reference |
| Fixture Requirement | ±1 mm Positioning Tolerance |
| Controller | Integrated Industrial PC-Based Equator Controller (No External PC Required) |