| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | FASTRACK™ |
| Accuracy | ±5 µm/m |
| Construction | Stainless Steel |
| Mounting Type | Bracket-Mounted |
| Serviceability | Modular, Segment-Replaceable Scale |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | ML10 Gold |
| Linear Resolution | 0.001 µm |
| Linear Range | 40 m (optional 80 m) |
| Linear Accuracy | ±0.7 ppm |
| Maximum Measurement Speed | 60 m/min |
| Long-Term Frequency Stability | ±0.05 ppm |
| Environmental Compensation | EC10 sensor integrated |
| Software Platform | Laser10 v5.x |
| Compliance Standards | ISO 230-2, VDI/VDE 2617, VDI 3441, ASME B89.1.12, JIS B6330, GB/T 17421.2–2016 |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | MP250 |
| Type | Strain-gauge contact probe |
| Application | In-machine metrology on grinding machines |
| Technology | Rengage™ strain-gauge sensing |
| Environmental rating | Designed for harsh machine tool environments (coolant, swarf, vibration) |
| Measurement principle | Resistive strain-gauge displacement transduction with analog signal conditioning |
| Probe body material | Aerospace-grade stainless steel |
| Interface | Compatible with Renishaw’s RMI-Q and RMI-Q2 radio transmission modules |
| Compliance | Meets ISO 10360-5 for probing performance |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | OMP400 |
| IP Rating | IPX8 |
| Operating Life | Up to 50 hours (continuous) |
| Dimensions | Ø40 mm × 50 mm |
| Compatible Receptors | OMM, OMI, OMI-2 |
| Trigger Technology | Strain Gauge-Based Optical Sensing |
| Interface | Modulated Optical Transmission |
| Application Scope | Z-axis–constrained machines, HSK32 & small-taper spindles |
| Compliance | Designed for ISO 230-2/6, ASME B5.54, and GLP/GMP-aligned process validation environments |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | PH10 |
| Interface Compatibility | AutoJoint (PH10M/MQ) or M8 threaded (PH10T) |
| Maximum Probe Extension | 300 mm |
| Compatible with | ACR3 automatic probe changer, SP25M 3-axis scanning probe (2000 points/sec, 100 mm/s scan speed), TP20/TP200 touch-trigger probes |
| Regulatory Compliance | Designed for integration into ISO/IEC 17025-accredited CMM environments |
| Software Integration | Native support for PC-DMIS, QUINDOS, and MODUS metrology software suites |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | PH20 |
| Type | Motorized 5-Axis Touch-Trigger Probe Head |
| Power Requirement | None (Passive, No Air Supply Required) |
| Compatibility | Retrofitable to Existing CMMs with TP20-style Interface |
| Calibration Method | Inferred Calibration (Single-Point Vector Determination) |
| Mounting Options | Direct Spindle Mount or Via Adaptor Kits (e.g., ISO 40/50, HSK, CAT) |
| Software Integration | Native Support in MODUS, PC-DMIS, QUINDOS, and OpenDMIS |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PH20 |
| Pricing | Available Upon Request |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | QC10 |
| Resolution | 0.1 µm |
| Sensor Accuracy | ±0.5 µm at 20 °C |
| Maximum Sampling Rate | 250 Hz |
| Optional Extension Rods | 50 mm, 150 mm, 300 mm |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | QC20-W |
| Type | Precision Geometric Measurement Instrument |
| Core Technology | Dual-Point Kinematic Interferometric Displacement Measurement |
| Communication | Bluetooth 5.0 (Class 1, up to 30 m range in line-of-sight) |
| Sensor Principle | Non-contact capacitive linear displacement sensing with integrated thermal compensation |
| Mechanical Design | Telescopic carbon-fiber arm (standard 100 mm–300 mm extension range, ISO 230-4 compliant length stability ±0.1 µm/°C) |
| Compliance | Fully compatible with ISO 230-4:2022, ANSI B5.54-2020, and VDI/VDE 2617 Part 6 |
| Software Platform | Renishaw Ballbar20 v4.x (Windows 10/11, 64-bit), supports FDA 21 CFR Part 11 audit trail, GLP/GMP-compliant report generation, and automated test sequence scripting |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | REVO™ |
| Pricing | Upon Request |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RM44 |
| Housing Material | Stainless Steel |
| Protection Rating | IP67 (IEC 60529) |
| Operating Temperature Range | −40 °C to +85 °C |
| EMC Compliance | EN 61000-6-2 / EN 61000-6-4 |
| Shock Resistance | 100 g (6 ms, half-sine) |
| Vibration Resistance | 10 g (10–2000 Hz, random) |
| Output Interface | Incremental (A/B/Z quadrature), Optional Sinusoidal 1 Vpp or RS422 |
| Maximum Resolution | Up to 131,072 counts/rev (configurable via interpolation) |
| Bearing Type | Dual-sealed, maintenance-free ball bearings |
| Electrical Connection | M12 connector (4-pin or 8-pin, depending on interface) |
| Shaft Configuration | Hollow shaft (standard), solid shaft (optional) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RMB28 |
| Type | Non-contact, Two-part Optical Encoder Module |
| Mounting | OEM-integrated, Direct-mount Design |
| Environmental Rating | IP64 (when fully assembled with compatible readhead and scale) |
| Output Interface | Analog 1 Vpp Sin/Cos or Digital A/B/Z TTL/RS422 (configurable per variant) |
| Typical Scale Pitch | 20 µm |
| Maximum Speed | >3 m/s (dependent on resolution and interface) |
| Operating Temperature | 0 °C to +50 °C |
| Thermal Expansion Coefficient Matching | Optimized for aluminum and stainless steel substrates |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RMC |
| Output Signals | RS422 differential quadrature (A/B/Z) + commutation (U/V/W) |
| IP Rating | IP67 (standard), optional IP69K |
| Mounting | Hollow-shaft or servo-mount compatible |
| Electrical Interface | 5 VDC or 10–30 VDC supply |
| Operating Temperature | −20 °C to +85 °C |
| Shock Resistance | 100 g, 6 ms (half-sine) |
| Vibration Resistance | 10 g RMS, 10–2000 Hz |
| Compliance | RoHS, CE, UL Recognized (E330024) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RMP40 |
| Form Factor | Ultra-compact (Ø40 mm × 50 mm) |
| Transmission Method | Bidirectional Radio Frequency (RF), 2.4 GHz ISM Band |
| Operating Range | Up to 3 m line-of-sight (typical), extended via optional repeater modules |
| Environmental Rating | IP67 (probe body), IP54 (receiver unit) |
| Battery Life | ≥12 months (alkaline AA cells, typical usage) |
| Compatibility | Renishaw RMI-Q / RMI-QE receivers, MP250/MP300 interface modules |
| Signal Protocol | Proprietary RF with CRC error checking and automatic retransmission |
| Temperature Range | −10 °C to +50 °C (operational) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RMP600 |
| Protection Rating | IPX8 |
| Transmission | Radio Frequency (RF) |
| Sensing Technology | RENGAGE™ Strain Gauge |
| Compatibility | CNC Machining Centers, Turning Centers, Mill-Turn Machines |
| Mounting | Spindle or Tool Magazine Interface |
| Environmental Suitability | Coolant-, Chip-, and Vibration-Resistant |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RTP20 |
| Probe Type | Integrated TP20 Touch Trigger Probe |
| Indexing Increment | 15° |
| Compatibility | Fully Supported by Standard CMM Controllers (e.g., Renishaw UCC Series) |
| Module Exchange | Compatible with MCR20 Automatic Module Changer Rack |
| Actuation Method | CMM-Motion-Driven Mechanical Engagement (No Internal Motor or Encoder) |
| Classification | Precision Geometric Measurement Instrument — Coordinate Measuring Machine (CMM) Peripheral |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | RX10 |
| Compatible Laser Systems | XL-80 or ML10 Laser Interferometer |
| Angular Accuracy | ≤1 arcsecond (standard), optional 0.5 arcsecond |
| Measurement Cycle Time | ≤25 minutes per full axis check |
| Mounting Orientation | Horizontal, vertical, or inverted |
| Built-in Calibration Routine | Yes |
| Automation Level | Fully motorized axis locking, unlocking, and rotation with auto-alignment and real-time tracking |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | SiGNUM™ |
| Enclosure Rating | IP64 (SR readhead) |
| Thermal Operating Range | −10 °C to +85 °C |
| Maximum Speed | >3600 rpm (at Ø52 mm) |
| Angular Accuracy | ±0.5 arc seconds |
| Repeatability | 0.02 arc seconds |
| Subdivision Error | <±40 nm |
| Scale Pitch | 20 µm |
| Scale Material | Stainless Steel (RESM ring) |
| Installation Flexibility | Tapered Mounting System |
| Signal Processing | SiGNUM™ Intelligent Interpolation |
| Zero Reference | IN-TRAC™ Bidirectional Optical Reference Marks |
| Compliance | RoHS, CE, UKCA |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | SP25M |
| Probe Type | Dual-mode (scanning + touch-trigger) |
| Sensor Integration | Integrated capacitive scanning sensor + mechanical trigger sensor |
| Compatible Shank Lengths | 20 mm to 400 mm |
| CMM Interface | Standard M3, M4, or HSK shank options (per OEM integration) |
| Operating Principle | Capacitive displacement sensing (scanning mode) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | TP200 |
| Probe Type | Modular Trigger (Kinematic) Probe for CMMs |
| Sensor Technology | Micro-strain Gauge |
| Repeatability | < 0.5 µm (3σ, under controlled conditions) |
| Overtravel Force Options | Standard Force (SF) or Low Force (LF) |
| Interface | PI 200 (Proprietary Renishaw CMM Interface) |
| Toolchanging Compatibility | SCR200 Automatic Probe Change Rack |
| Electronics | ASIC-based Signal Conditioning and Debounce Circuitry |
| Operating Life | > 10⁶ triggers (typical, per module) |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | XL-80 |
| Measurement Principle | Stabilized HeNe laser interferometry (wavelength 632.991 nm, traceable to SI meter) |
| System Accuracy | ±0.5 ppm (0–40 °C, compensated) |
| Resolution | 0.001 µm |
| Max Linear Velocity | 4.0 m/s |
| Sampling Rate | 50 kHz |
| Measurement Range | 0–80 m |
| Laser Warm-up Time | ~6 min |
| Environmental Compensation | XC-80 sensor (updates compensation every 7 s) |
| Laser Source Stability | ±0.05 ppm |
| Beam Height & Optical Compatibility | Fully compatible with ML10 optics and mounts |
| Software Suite | LaserXL™ (step-by-step metrology workflows), QuickViewXL™ (real-time display) |
| Warranty | 3 years standard, extendable to 5 years |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | XL-80 |
| Weight | 12 kg (complete system in portable case) |
| Linear Accuracy | ±0.5 ppm |
| Maximum Linear Velocity | 4 m/s |
| Data Acquisition Rate | 50 kHz |
| Linear Resolution | 1 nm |
| Environmental Compensation | Integrated XC-80 compensator via USB |
| Interface | Native USB connection to PC (no external interface required) |
| Warranty | 3-year standard warranty |
| Compliance | Fully traceable to SI units |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | XL80 |
| Measurement Speed | up to 4.0 m/s |
| Sampling Rate | up to 50 kHz |
| Linear Accuracy | ±0.5 ppm (0–40 °C) |
| Laser Stabilization Accuracy | ±0.05 ppm |
| Resolution | 0.001 µm |
| Maximum Linear Measurement Range | 80 m |
| Warm-up Time | ~6 minutes |
| Environmental Compensation | via XC-80 sensor (7-second update interval) |
| Wavelength Reference | Stabilized HeNe laser (traceable to SI meter) |
| Optical Compatibility | Fully backward-compatible with ML10 interferometer optics |
| Software | LaserXL™ (step-by-step machine tool verification), QuickViewXL™ (real-time display) |
| Portability | Total system weight <15 kg (laser head + XC-80 + cables + power supply + sensors) |
| tripod weight | 6.2 kg |
| Warranty | 3-year standard, extendable to 5 years |
| Brand | Renishaw |
|---|---|
| Origin | United Kingdom |
| Model | XR20-W |
| Weight | ~1 kg (unit device), <7 kg (full system in Peli™ case) |
| Measurement Accuracy | ±1 arcsecond |
| Power | Rechargeable battery |
| Connectivity | Bluetooth® 4.0 |
| Compatible Laser Interferometers | XL-80 (standard), ML10 (USB interface version forthcoming) |
| Compliance | Fully calibrated and certified per ISO 10360 and ISO 230-4 prior to shipment |
| Software | Renishaw XCalibrator v3.x with ISO 230-4 / ASME B5.54 preconfigured test templates, automatic alignment calibration, GLP-compliant audit trail |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | RK-PM300 |
| Output Interface | RS-485 (Modbus RTU) |
| Enclosure Material | Stainless Steel (316L) |
| Protection Rating | IP54 |
| Supply Voltage | 10–30 VDC |
| Overvoltage Protection | Up to 2× Full Scale |
| Temperature Compensation | Built-in Automatic Compensation |
| Pressure Range Options | –0.1 to 60 MPa (gauge, vacuum, absolute) |
| Communication Distance | Up to 2000 m |
| Compliance | EMI Immunity per IEC 61000-6-2, RoHS Directive 2011/65/EU |
| Optional Dual Measurement | Simultaneous Pressure & Inlet Port Temperature |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RS-HW-N01 |
| Instrument Type | Fixed-mount |
| Power Supply | 10–30 V DC |
| Power Consumption | 0.4 W |
| Sensor Type | Dual-element pyroelectric infrared (PIR) sensor |
| Alarm Duration Options | 5 s / 10 s / 30 s (configurable) |
| Delay-on-Alarm | Software-configurable |
| Mounting Method | Ceiling-mounted |
| Installation Height | 2.5–6 m |
| Detection Range | Ø6 m (at 3.6 m mounting height) |
| Detection Pattern | Omnidirectional 360° horizontal coverage |
| Output Interface | RS-485 |
| Communication Protocol | Modbus-RTU |
| Operating Temperature | −10 °C to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| RFI Immunity | 20–1000 MHz |
| Microcontroller | 8-bit low-power CMOS |
| Auto Temperature Compensation | Yes |
| Brand | RenKe |
|---|---|
| Model | RS-QY-N01-2 |
| Measurement Principle | Piezoresistive Sensing with Integrated Temperature Compensation |
| Pressure Range | 0–120 kPa |
| Temperature Range | −40 to +80 °C (standard) |
| Pressure Accuracy | ±0.15 kPa @ 25 °C, 75 kPa |
| Temperature Accuracy | ±0.5 °C @ 25 °C |
| Long-Term Stability | ≤−0.1 kPa/year (pressure), ≤0.1 °C/year (temperature) |
| Output | RS-485 Modbus RTU (default baud rate: 4800, 8N1) |
| Power Supply | 10–30 V DC |
| Power Consumption | ≤0.5 W |
| Response Time | ≤1 s |
| Operating Environment | −20 to +60 °C, 0–80 %RH |
| Enclosure Type | Wall-Mounted IP65 Housing |
| Compliance | CE-marked design principles, RoHS-compliant materials, compatible with ISO/IEC 17025-aligned calibration workflows |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | RS-SJ-N01-2 |
| Output Options | RS485 (Modbus-RTU), Relay Dry Contact (NO) |
| Power Supply | DC 10–30 V |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity Range | 0–80% RH |
| Max RS485 Distance | 2000 m |
| Max Electrode/Cable Length | 30 m |
| IP Rating | IP67 (inferred from waterproof housing & harsh-environment deployment) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | RS-WD-*-2 |
| Pricing | Upon Request |
| Power Supply | 10–30 V DC |
| Output Options | 4–20 mA / 0–5 V / 0–10 V |
| Default Accuracy | ±0.5 °C @ 25 °C |
| Operating Ambient Temp | −40 °C to +60 °C |
| Probe Temp Range | −40 °C to +120 °C (varies by probe type) |
| Humidity Range (probe) | 0–99 %RH |
| Long-Term Stability | ≤0.1 °C/year |
| Response Time | ≤10 s (at 1 m/s airflow) |
| Load Capacity | ≤600 Ω (current), ≤250 Ω (voltage) |
| Enclosure Type | IP65-rated wall-mounted “Wangzi” (character-style) housing |
| Mounting | Screw + anchor (included) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | RS-WS-DY |
| Communication | FHSS Radio (868 MHz ISM Band) |
| Display | 2.8" LCD with Real-Time Temp/RH/Time/Address/Storage Status |
| Power Supply | 10–30 V DC (AC/DC Adapter Included for 220 V AC Input) |
| Operating Temperature (Electronics) | −20 °C to +60 °C |
| Operating Humidity (Electronics) | 0–80 %RH |
| Sensor Operating Range (Standard Probe) | −40 °C to +80 °C, 0–99 %RH |
| Sensor Operating Range (Optional −B Wide-Temp Probe) | −40 °C to +120 °C |
| Accuracy (Class A) | ±0.4 °C @ 25 °C, ±2 %RH @ 25 °C (5–95 %RH) |
| Accuracy (Class B, Default) | ±0.5 °C @ 25 °C, ±3 %RH @ 25 °C (5–95 %RH) |
| Resolution | 0.1 °C / 0.1 %RH |
| Long-Term Drift | ≤0.1 °C/year, ≤1 %RH/year |
| Response Time (Standard Probe) | ≤25 s (Temp), ≤8 s (RH) at 1 m/s airflow |
| Response Time (−B Probe) | ≤18 s (Temp), ≤6 s (RH) at 1 m/s airflow |
| Data Storage Capacity | 65,535 records |
| Recording Interval | 1–65,535 minutes (configurable, default 30 min) |
| Storage Duration (at 30-min interval) | ~4 years |
| Storage Mode | Auto-cyclic overwrite |
| Alarm Outputs | 2 programmable relay outputs (NO/NC), 1 internal buzzer (85 dB), optional external sound-light alarm interface |
| Calibration | Password-protected on-device offset calibration for temperature and humidity |
| Compliance | FCC Part 15 Subpart C, CE RED Directive 2014/53/EU, RoHS 2011/65/EU |
| Wireless Protocol | Proprietary FHSS (Frequency-Hopping Spread Spectrum), 868 MHz, 100 kbps data rate |
| Line-of-Sight Range | ≥800 m |
| Wall Penetration | 3–4 reinforced concrete walls |
| Max Nodes per RS-JSQ-W Gateway | 200 units |
| Enclosure Rating | IP65 (housing), IP67 (optional −B and −6 waterproof probe variants) |