| Brand | SevenStar |
|---|---|
| Origin | Beijing, China |
| Model | D07-7C |
| Flow Range (N₂) | 5 SCCM to 10 SLM |
| Control Range | 2–100% F.S. |
| Valve Type | Solenoid-Controlled Proportional Valve (Normally Closed) |
| Accuracy | ±1.5% F.S. |
| Linearity | ±1% F.S. |
| Repeatability | ±0.2% F.S. |
| Electrical Response Time | 10 s |
| Gas Response Time | ≤4 s |
| Operating Temperature | 5–45 °C |
| Operating Pressure Drop | 0.1–0.5 MPa |
| Burst Pressure Rating | 3 MPa |
| Helium Leak Rate | ≤1×10⁻⁸ atm·cm³/s |
| Sealing Materials | Fluoroelastomer (FKM), Chloroprene Rubber (CR) |
| Electrical Connector | DB15 Female |
| Tube Fitting Options | VCR 1/4″, φ4 mm & φ6 mm hose, Swagelok 1/4″, φ3 mm & φ6 mm |
| EMC Compliance | CE |
| Weight | 1.1 kg |
| Brand | SevenStar |
|---|---|
| Origin | Beijing, China |
| Model | D07-7CM |
| Flow Principle | Thermal Mass Flow Measurement (Constant Temperature Anemometry) |
| Gas Medium | N₂-calibrated (standardized at 0 °C, 101.325 kPa) |
| Full-Scale Range | 5 SCCM – 10 SLM (N₂) |
| Control Range | 2–100 % F.S. |
| Accuracy | ±1.5 % F.S. |
| Linearity | ±1 % F.S. |
| Repeatability | ±0.2 % F.S. |
| Response Time | ≤10 s |
| Operating Temperature | 5–45 °C |
| Maximum Pressure Drop | <0.01 MPa |
| Burst Pressure | 3 MPa |
| Helium Leak Rate | ≤1×10⁻⁸ atm·cm³/s |
| Sealing Material | Fluoroelastomer (FKM) or Neoprene |
| Power Supply | +15 V/50 mA, −15 V/50 mA |
| Analog Output | 0–5.00 V DC |
| Electrical Connector | DB15 female |
| Process Connections | VCR 1/4″, Swagelok 1/4″, or φ3/φ4/φ6 stainless steel tubing |
| EMC Compliance | CE certified |
| Weight | 0.92 kg |
| Construction | Tubular bypass design with integrated thermal sensor |
| Brand | SevenStar |
|---|---|
| Origin | Beijing, China |
| Model | D08-1F |
| Power Supply | ±15 V DC / 400 mA, +5.00 V DC / 5 mA |
| Input Voltage Range | 85–260 V AC |
| Max. Power Consumption | 15 W |
| Analog Input Signals | 0–+5 V (voltage), 4–20 mA (current, optional 0–10 mA) |
| Analog Output Signals | 0–+5 V (flow detection), ±15 V (valve control) |
| Display Channels | 1-channel MFC/MFM interface |
| Weight | 1 kg |
| Compliance | CE-certified |
| Type | Volumetric flow display instrument for gas mass flow controllers and meters |
| Brand | SevenStar |
|---|---|
| Origin | Beijing, China |
| Model | D08-8C |
| Type | Volumetric Flow Totalizer |
| Power Supply | 85–265 VAC, 50/60 Hz, 12 W |
| Output Voltages | +15 V @ 200 mA, −15 V @ 400 mA |
| Max. Accumulated Flow | 999999 L or m³ |
| Accumulation Accuracy | < ±0.3% FS |
| Input/Output Signals | 0–+5 V analog (flow detection, setpoint, valve control) |
| Display | Dual digital LCD (instantaneous & cumulative flow) |
| Control Channels | 1-channel MFM/MFC interface |
| Weight | 0.5 kg |
| Enclosure Grounding | Dedicated chassis ground terminal |
| Compliance | CE-marked |
| Brand | Biaozhuo |
|---|---|
| Origin | Shanghai, China |
| Model | YCM-T |
| Measurement Range | 0–2000 pS |
| Expanded Uncertainty | ≤1% (k=2) |
| Dimensions (L×W×H) | ≤250 mm × 170 mm × 180 mm |
| Weight | ≤2.5 kg |
| Interface | BNC + Terminal Block |
| Insulation Resistance (between terminals) | ≥1×10¹³ Ω·m |
| Brand | SOPTOP Hengping |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Linearity | ±0.2 mg |
| Calibration | External |
| Pan Diameter | 90 mm |
| Dimensions (W×D×H) | 365 × 223 × 338 mm |
| Draft Shield Size | 150 × 165 × 200 mm |
| Interface | RS232 |
| Environmental Compensation | Dynamic Temperature Compensation |
| Protection | Overload & Shock Protection |
| Functions | Piece Counting, Percentage Weighing, Unit Conversion (g, oz, ct), Auto-Zero Tracking, Factory Reset, Linear Correction |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Type | Precision Balance |
| Maximum Capacity | 100–6000 g |
| Readability | 0.01 g (JY1002/JY2002/JY3002/JY5002/JY6002/JY10002/JY20002 models) |
| Calibration | External calibration with standard weights |
| Repeatability | ≤ ±0.001 g (at full load, typical) |
| Pan Diameter | Φ110 mm to 170 × 185 mm |
| Dimensions (L×W×H) | 225 × 185 × 55 mm |
| Power Supply | AC 220 V, 50 Hz, 3 VA |
| Net Weight | 2.0–2.3 kg |
| Display | High-contrast LED |
| Key Functions | Counting, unit conversion (g/oz/carat), auto-zero tracking, tare, auto-overload protection, self-diagnostics, memory recall |
| Draft Shield | Removable plastic draft shield (left/right/top access) |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | JA5003J |
| Maximum Capacity | 500 g |
| Readability | 1 mg |
| Repeatability | ±1 mg |
| Calibration | External |
| Interface | RS232C |
| Minimum Sample Mass in Air | ≥0.25 g |
| Minimum Buoyant Force in Water | < −0.125 g |
| Density Measurement Resolution | 0.001 g/cm³ |
| Application Type | Solid & Liquid Density Determination via Archimedean Principle |
| Brand | Shanghai Xiande |
|---|---|
| Origin | Shanghai, China |
| Model | GMVC-3000pro |
| Control Range | 1–800 mmHg (Torr), 1–1066 hPa (mbar), 0–106.6 kPa, 0 to –0.01 MPa |
| Pressure Type | Negative (Vacuum) |
| Display | Digital Touchscreen (5.5″ Color LCD) |
| Ultimate Vacuum | 8 mbar |
| Max Pumping Speed | 20 or 30 L/min |
| Interface | Quick-Connect Ø10 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 130 W |
| Standby Power | 3 W |
| Noise Level | ≤55 dB(A) |
| Operating Temperature | 5–40 °C |
| IP Rating | IP20 |
| Dimensions (L×W×H) | 185 × 310 × 310 mm |
| Weight | 13 kg |
| Optional Steam Temperature Monitoring | –20 to 200 °C |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FA1004, FA1104, FA1604, FA2004, FA2104, FA2104S, FC104, FC204, JA5003 |
| Capacity | 100–500 g |
| Readability | 0.0001 g (models FA/FC series), 0.001 g (JA5003) |
| Repeatability | ≤ ±0.0001 g (FA/FC), ≤ ±0.001 g (JA5003) |
| Linearity | ≤ ±0.0002 g (FA/FC), ≤ ±0.002 g (JA5003) |
| Pan Diameter | Φ90 mm (FA/FC), Φ125 mm (JA5003) |
| Brand | Shenyang Longteng / Longteng |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model Series | ESJ Series (Density & Hydrostatic Weighing) |
| Instrument Type | Analytical Balance with Integrated Density/Hydrostatic Module |
| Maximum Capacity | 200–500 g (ESJ variants) |
| Readability | 0.0001 g (ESJ-4A models), 0.001 g (JD-3M), 0.01 g (JD-2M) |
| Repeatability | ±0.0001 g (ESJ), ±0.001 g (JD-3M), ±0.01 g (JD-2M) |
| Calibration | Internal Automatic Calibration |
| Pan Size | Φ90 mm (standard) |
| Dimensions (ESJ220-4AM) | Approx. W120 × D125 × H310 mm (stand assembly included) |
| Brand | Shenyang Longteng (Longteng) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model Series | ESK Series (Density & Hydrostatic Weighing) |
| Instrument Type | Precision Laboratory Balance |
| Maximum Capacity | Up to 60 kg |
| Readability | 0.01 g to 1 g (model-dependent) |
| Repeatability | ±0.01 g |
| Calibration | Internal Automatic Calibration |
| Pan Size | Up to 340 × 300 mm |
| Hydrostatic Accessories | Suspended Basket (Φ250 × 220 mm), Water Tank (Φ300 × 280 mm), Support Frame (520 × 450 × 400 mm) |
| Compliance | Designed for ASTM D792, ISO 1183, and GB/T 1033 density determination protocols |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model Series | AP |
| Instrument Type | Analytical Balance |
| Capacity Range | 2 g – 5 g |
| Readability | 0.1 mg (0.0001 g) |
| Interface | Standard USB 2.0 |
| Application Focus | Pharmaceutical Sample Preparation, Buffer Solution Weighing, GLP/GMP-Compliant Weighing Tasks |
| Electrostatic Mitigation | Integrated Active Static Elimination System |
| Compliance | Designed to support ISO/IEC 17025, USP <41>, and FDA 21 CFR Part 11 data integrity requirements |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AP135W |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 135 g |
| Readability | 0.01 mg |
| Repeatability | 0.05 mg |
| Calibration | Internal |
| Sensor Technology | UniBloc AP Monolithic Sensor |
| Static Elimination Option | STABLO-AP Ionizer |
| Software Integration | LabSolutions Balance |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AP135W |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 135 g |
| Readability | 0.01 mg (10 µg) |
| Repeatability | 0.05 mg |
| Calibration | Internal |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready |
| Connectivity | USB interface for data export and peripheral integration |
| Operating Environment | 18–26°C, 30–70% RH (non-condensing) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Product Type | Imported Analytical Balance |
| Model | AP224W |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Calibration | Internal and External |
| Compliance | ISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready |
| Connectivity | USB interface for data export, image capture (BMP), and peripheral integration |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Japan |
| Model | AP225W |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | ≤0.05 mg |
| Sensor Technology | UniBloc AP |
| Stabilization Time | 1.5 s (for 1 mg load) |
| Interface | USB + RS-232C |
| Compliance | ISO/IEC 17025, USP <41>, FDA 21 CFR Part 11 (with Labsolutions Balance), GLP/GMP-ready printing |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AP225W-AD |
| Instrument Type | Ultra-Micro Balance |
| Maximum Capacity | 220 g |
| Readability | 0.01 mg |
| Repeatability | 0.01 mg (at 5 g load), 0.015 mg (at ~20 g), 0.03 mg (at ~100 g) |
| Calibration | Internal motorized auto-calibration with optional external weight support |
| Display | OLED matrix display (±85° viewing angle) |
| Auto-Door | Motorized full-glass door with proximity-sensing activation |
| Non-Contact Control | Dual side-mounted capacitive sensors for function selection |
| Static Elimination | Integrated STABLO™-AP electrostatic neutralizer |
| Operating Environment | 5–40 °C, 20–85 % RH |
| Linearity Error | ±0.1 mg |
| Minimum Weighing Value | 20 mg |
| Sensitivity Temperature Coefficient | ±2 ppm/°C (10–30 °C) |
| Pan Diameter | Ø91 mm |
| Dimensions (W×D×H) | 212 × 411 × 345 mm (incl. power unit) |
| Weight | 9.7 kg |
| Connectivity | RS-232C, USB-A (host), USB-B (device) |
| Brand | Shimadzu |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Analytical Balance |
| Capacity | 220 g |
| Readability | 0.1 mg |
| Max Weighing Range | 320 g |
| Repeatability | ±0.1 mg |
| Calibration | Internal & External |
| Interface | USB + RS-232C |
| Environmental Compensation | PSC (Proactive Self-Calibration) Temperature-Triggered Alert |
| Optional Accessories | STABLO™-AP Electrostatic Discharger, Smart Stand Holder |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model Series | ATX & ATY |
| Measurement Principle | Electromagnetic Force Compensation (EMFC) |
| Max Capacity | 220 g (ATX224/ATY224) to 62 g (ATY64) |
| Minimum Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Linearity Error | ±0.2 mg |
| Stabilization Time | ≤2.5 s |
| Pan Size | 91 mm diameter |
| Calibration | Internal Auto-Calibration with External Weights |
| Compliance | ISO/IEC 17025, ASTM E898, USP <41>, GLP/GMP-ready |
| Interface | RS-232, USB (optional), Direct Windows Data Transfer (No Driver Required) |
| Environmental Adaptation | Adjustable Filter Settings (Stability/Response Trade-off) |
| Sensor Architecture | Monolithic UniBloc Dual-Lever EMFC Sensor |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Japan |
| Model | AU-SGM |
| Type | Analytical Density Balance |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg (0.0001 g) |
| Density Resolution | 0.0001 g/cm³ |
| Repeatability | 0.0001 g/cm³ |
| Calibration | Manual or Automatic (Selectable) |
| Principle | Archimedean Buoyancy Method (Liquid Immersion) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, compatible with GLP/GMP documentation workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Product Type | Imported Laboratory Density Analyzer |
| Model Series | AU-SGM (including AUW-D-SGM, AUW-SGM, AUX-SGM, AUY-SGM) |
| Density Resolution | 0.0001 |
| Solid Density Measurement | Standard |
| Liquid Density Measurement | Optional (with accessory sinker P/N 321-60640) |
| Weighing Capacity Range | 40–320 g (model-dependent) |
| Minimum Readability | 0.01 mg to 0.1 mg (model-dependent) |
| Sensor Technology | Uni Bloc Monolithic Load Cell |
| Enclosure | Integrated Draft Shield |
| Compliance | Designed for GLP/GMP environments with audit-ready operation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AU-SMK |
| Pricing | Upon Request |
| Weighing Capacity | 120–320 g |
| Minimum Readability | 0.1 mg |
| Density Resolution | 0.0001 g/cm³ |
| Density Measurement Modes | Solid (fixed-density method), Liquid (requires optional sinker P/N 321-60640) |
| Origin | Japan |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Interior Materials Testing System |
| Pricing | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Series | AUW-D / AUW / AUX / AUY |
| Models | AUW320 / AUW220 / AUW120 |
| Capacity | 120 g – 320 g |
| Readability | 0.1 mg |
| Pan Diameter | ≈ 80 mm |
| Dimensions (W × D × H) | 220 × 330 × 310 mm |
| Weight | ≈ 7 kg |
| Power Consumption | ≈ 7 VA |
| Interface | RS-232C, Data I/O, Keyboard Input |
| Features | PSC Auto-Calibration, Timed Calibration, Internal Clock, ISO Print Output, Direct-Window Data Transfer, Density Determination (with optional kit), Piece Counting, Unit Conversion, Backlit LCD, Analog Display Mode, Battery Operation (optional) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AUW120D / AUW220D / AUW320D |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Weighing Pan Diameter | 80 mm |
| Dimensions (W×D×H) | 220 × 330 × 310 mm |
| Weight | 7 kg |
| Power Consumption | 7 VA |
| Operating Temperature | 5–40 °C |
| Sensitivity Drift | ±2 ppm/°C (10–30 °C, PSC OFF or ON) |
| Stabilization Time | ≤3 s |
| Linearity Error | ±0.2 mg |
| Standard Deviation | ≤0.1 mg |
| Interface | RS-232, Direct PC Connection via USB-to-RS232 cable |
| Compliance | GLP/GMP/ISO-compliant calibration reporting |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AUW-D Series |
| Capacity | 220 g / 120 g |
| Readability | 0.1 mg / 0.01 mg |
| Pan Diameter | ~80 mm |
| Dimensions (W × D × H) | 220 × 330 × 310 mm |
| Weight | ~7 kg |
| Power Consumption | ~7 VA |
| Interface | RS-232C, Data I/O, Keyboard |
| Features | PSC Auto-Calibration, Timer Calibration, Direct-Window Function, ISO Print Output, Interval Data Output, Internal Clock, Density Determination (with optional kit), Counting & Unit Conversion, Analog Display, Battery Operation (optional) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AUW220D / AUW120D |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g / 120 g |
| Readability | 0.01 mg (10 µg) |
| Repeatability | 0.02 mg |
| Calibration | Internal motorized calibration with built-in weights |
| Calibration Modes | PSC (Programmable Self-Calibration) and Clock-CAL |
| Compliance | GLP/GMP/ISO data integrity support |
| Interface | Standard DATA I/O port for direct printer connection |
| Data Transfer | Native Windows Direct-Window™ functionality (no driver or third-party software required) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model Series | AUX |
| Capacity | 120 g / 220 g / 320 g |
| Readability | 0.1 mg |
| Pan Diameter | ~80 mm |
| Dimensions (W × D × H) | 330 × 220 × 310 mm |
| Weight | ~7 kg |
| Power Consumption | ~7 VA |
| Interface | RS-232C, Data I/O, Keyboard |
| Features | PSC Automatic Calibration, Motorized Calibration, Built-in Real-Time Clock, ISO Print Output, Draft Shield Window, Interval Data Output, Full Digital Control, Density Determination (optional), Piece Counting & Unit Conversion, Analog Display Mode, Optional Battery Operation |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AUX220 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Standard Deviation | ≤0.1 mg |
| Linearity Error | ±0.2 mg |
| Stabilization Time | 3 s |
| Internal Calibration | Yes |
| Operating Temperature Range | 5–40 °C |
| Sensitivity Drift (PSC OFF, 10–30 °C) | ±2 ppm/°C |
| Sensitivity Drift (PSC ON, 10–30 °C) | ±2 ppm/°C |
| Pan Diameter | 80 mm |
| Dimensions (W×D×H) | 220 × 330 × 310 mm |
| Weight | 7 kg |
| Power Consumption | 7 VA |