Measurement Instruments
Filter
Showing 2221–2250 of 2724 results
| Brand | Taylor Hobson |
|---|---|
| Origin | United Kingdom |
| Model | PGI Matrix 1 / PGI Matrix 3 / PGI Matrix 5 |
| Type | Contact Profilometer / Surface Roughness Tester |
| Measurement Principle | Precision Stylus-Based Topographic Profiling with PGI (Precision Geometry Interferometry) Signal Processing |
| Software Platform | Form Talysurf Intra (v6.0+) with Advanced Aspheric Analysis Unit (AAU) |
| Compliance | ISO 25178-2, ISO 4287, ISO 11562, ISO 12780, ASTM E1158, USP <1058> (Analytical Instrument Qualification), FDA 21 CFR Part 11 (Audit Trail & Electronic Signatures Enabled) |
| Environmental Compensation | Real-time X-axis & radius thermal drift compensation algorithm |
| Key Output Metrics | Residual form error (sub-micron), aspheric deviation (nm-level), slope error (µrad), ring zone depth, diffraction step height reconstruction, reverse-coefficient fitting for aspheric/diffractive surfaces |
| Brand | Taylor Hobson |
|---|---|
| Origin | United Kingdom |
| Model | PGI Matrix 1 / PGI Matrix 3 / PGI Matrix 5 |
| Category | Precision Geometric Measurement Instrument (Optical Profilometer) |
| Compliance | ISO 25178-2, ISO 10110-5, ISO 1101, ASTM E2923, USP <1058> (for instrument qualification), FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R-100 |
| Pricing | Available Upon Request |
| Max. Specimen Weight | 20 kg |
| Max. Measurable Diameter | Ø 300 mm |
| Max. Measurable Height | 280 mm |
| Radial Roundness Error Limit | ±0.025 µm |
| Angular Resolution | 6 nm |
| Power Consumption | 160 W |
| Brand | Taylor Hobson |
|---|---|
| Origin | United Kingdom |
| Model | S116 / S128 |
| Type | Contact Profilometer & Surface Roughness Tester |
| Drive Mechanism | Stainless Steel Linear Actuator |
| Probe Lift Range | 50 mm |
| Maximum Measurement Depth | 70 mm |
| Display | 4.3-inch TFT Touchscreen (Rotatable 360°) |
| Battery | High-Capacity Lithium-Polymer (≥2000 measurements per charge |
| Interface | USB-A 2.0 (printer/data export), Micro-USB 2.0 (charging/data transfer) |
| Environmental Durability | Rubberized Shock-Absorbing Housing, Polyester Touchscreen Overlay, Wear-Resistant Gearing |
| Mounting Flexibility | V-Groove Feet for Flat or Curved Surfaces, Inverted Probe Capability |
| Parameter Display | Up to 7 roughness parameters simultaneously on single screen |
| Brand | Taylor Hobson |
|---|---|
| Origin | United Kingdom |
| Model | S116 / S128 |
| Battery Life | ≥2000 measurements per charge |
| Standby Time | Up to 5000 hours |
| Vertical Travel | 50 mm (with optional right-angle probe for up to 70 mm depth access) |
| Display | 4.3-inch capacitive touchscreen, rotatable in four orientations |
| Interface | USB Type-A 2.0 (printer/data storage), Mini-USB 2.0 (charging/data transfer) |
| Housing | Rubberized impact-resistant polymer casing |
| Touchscreen Overlay | Durable polyester film |
| Drive Mechanism | Stainless steel gear-and-bearings assembly |
| Probe Orientation | Standard and inverted (underside measurement capability) |
| Foot Design | V-groove anti-slip base for flat or curved surfaces |
| Compliance | Designed for ISO 4287, ISO 4288, ISO 25178-2, ASME B46.1, and relevant EN standards |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR 500 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TR 565 / TR 585 |
| Quotation | Upon Request |
| Max. Workpiece Weight | 75 kg |
| Max. Measurement Height | 300 / 500 / 900 mm (configurable) |
| Max. Measurement Diameter | Ø 400 mm (expandable to Ø 485 mm) |
| Radial Error Limit | ±(0.015 µm + 0.0003 × H µm), H in mm (1–50 UPR filter) |
| Resolution | 0.5 nm |
| Maximum Data Points | 18,000 per trace |
| Calibration | Patented spherical artifact-based probe curvature compensation |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Talyrond 595 |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Model | ZK2130 |
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range | 20–150 Ω |
| Length Range | 0.05–2 m |
| Accuracy | ±1% @ 50 Ω |
| Measurement Speed | ≤1 s per point |
| Bandwidth | 3 GHz |
| Dynamic Range for S-Parameter Measurement | >100 dB |
| Compliance | Designed for IPC-TM-650 2.5.1 and IPC-TR-579 compliant PCB impedance verification |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 4RD |
| Price | USD $100,000 |
| Electrode Count | 12 / 24 / 36 |
| SNR | >60 dB |
| Data Acquisition Rate | 2 ms/frame (12 ch), 5 ms/frame (24 ch), 10 ms/frame (36 ch) |
| Capacitance Resolution | 1 fF |
| Excitation Signal | 0–10 V<sub>p-p</sub> at 2 MHz |
| Sensor Interface | Removable sensors with BNC connectors |
| Sensor Geometry Support | Planar, circular, square, or custom complex geometries |
| Image Reconstruction Algorithms | Linear Back Projection (LBP), Iterative LBP (ILBP), 3D-NNMOIRT |
| Volumetric Resolution | ±3% |
| Power Supply | 110–240 V AC, 50–60 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECT-12 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECVT |
| Pricing | Available Upon Request |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Techcomp (formerly Shanghai Jingke/SHANGPING) |
| Product Line | FA-C Series |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg (0.0001 g) |
| Repeatability | 0.1 mg |
| Calibration | Internal calibration (optional SCS Smart Calibration System) |
| Display | Backlit dot-matrix LCD with bilingual (Chinese/English) menu |
| Units | g, ct, oz, dwt, lb, etc. |
| Compliance Features | Real-time clock, GLP/GMP-compliant data logging, EMC-compliant electronics |
| Special Functions | Density determination, percentage weighing, accumulation, counting, below-balance weighing, tare memory |
| Connectivity | RS-232 interface (data cable optional) |
| Qualification Support | 3Q (IQ/OQ/PQ) documentation available |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Techcomp (formerly Jingke/Shangping) |
| Type | Precision Balance |
| Maximum Capacity | 1000 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Linearity Compensation | Multi-point Linear Calibration |
| Drift Compensation | Yes |
| Construction | SMT-assembled PCB with SMD components |
| Display | LCD, low-power |
| Interface | RS232C (optional) |
| Operating Mode | Portable |
| Functions | Accumulation, Piece Counting, Tare, Unit Conversion, Error Alert |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A.B.C.D.E Temperature Indicating Strip |
| Pricing | Available Upon Request |
| Temperature Range | −30 °C to 260 °C |
| Accuracy | ±1 °C |
| Calibration Traceability | ISO/IEC 17025-accredited reference standards |
| Compliance | ISO 9001 certified manufacturing & quality control |
| Format | Adhesive-backed multi-point irreversible thermal indicator strip with 5 discrete temperature bands (A–E), each containing 8 calibrated temperature-sensitive elements |
| Origin | Russia |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Tera-Ax |
| Pricing | Upon Request |
| Central Frequency | 1 THz |
| Spectral Bandwidth | 1.5 THz |
| Pulse Duration | <1 ps |
| Maximum THz Pulse Energy | 1 nJ |
| Pump Source Compatibility | Commercial Ti:Sapphire Amplifiers |
| Detection Option | EO-AX Electro-Optic THz Detector |
| Generation Mechanism | Tilted Pulse Front (TPF) |
| Nonlinear Crystal | MgO-doped LiNbO₃ |
| Brand | TES |
|---|---|
| Origin | Taiwan |
| Model | TES-1327 |
| Measurement Range | -35 °C to +500 °C (-31 °F to 932 °F) |
| Resolution | 0.1 °C / 0.2 °F |
| Accuracy | ±2% of reading or ±2 °C (whichever is greater) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 12:1 |
| Emissivity Adjustment | 0.17–1.00 |
| Laser Targeting | Class II, <1 mW |
| Memory Capacity | 50 data points |
| Display | Backlit LCD |
| Auto Power-Off | ~15 seconds |
| Battery | 9V alkaline (006P) |
| Operating Environment | 0–50 °C, ≤80% RH |
| Storage | -10–60 °C, ≤70% RH |
| Dimensions | 172 × 118 × 46 mm |
| Weight | 220 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TES-PAPER |
| Pricing | Available Upon Request |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0516 1901 |
| Dimensions (L×W×H) | 340 × 265 × 60 mm |
| Weight | 1130 g |
| Housing Material | High-strength plastic |
| Interface | USB |
| Capacity | Simultaneous programming and readout of up to 8 compatible Testo data loggers |
| Software | Not included — sold separately |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9330 |
| Communication Interface | Ethernet with IEEE 802.3af PoE (Class 0) |
| Compatibility | testo 150 modular data logger system |
| Channel Architecture | Multi-channel, module-integrated |
| Integration Standard | Designed for testo Saveris Pharma environmental monitoring platform |
| Radio Option Support | Compatible with testo UltraRange wireless extension (optional) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9055 |
| Temperature Measurement Principle | K-type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | −50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Stability | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Response Time (t₉₉) | 10 s in water |
| Weight | 80 g |
| Dimensions (L×W×H) | 270 × 40 × 70 mm |
| Probe Sheath Length | 200 mm |
| Probe Tip Length | 4 mm |
| Probe Rod Diameter | 3 mm |
| Display | Single-line LCD |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | −20 to +70 °C |
| Housing Material | ABS |
| Power Supply | 3 × AAA batteries (rechargeable) |
| Battery Life | Up to 1000 h |
| CE Marking | 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| IP Rating | IP65 |
| Probe Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Folded Dimensions | 163 × 47 × 20 mm |
| Extended Dimensions | 265 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Power Supply | 2 × AAA batteries |
| Battery Life | 100 h (+25 °C, no backlight) |
| Display | Single-line LCD with backlight |
| Compliance | EN 13485, HACCP, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1063 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-30 to +99.9 °C), ±1.0 °C (full range) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| Power Source | CR2032 lithium coin cell |
| Dimensions (L×W×H) | 215 × 34 × 19 mm |
| Weight | 80 g |
| IP Rating | IP67 (with protective sleeve 0516 8265) |
| Measurement Rate | 2 readings per second |
| Compliance | ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | −10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery (approx. 70 h lifetime) |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Sensor Type | Integrated capacitive humidity sensor + NTC temperature sensor |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| IP Rating | IP65 |
| Dimensions (probe extended) | 265 × 47 × 20 mm |
| Dimensions (probe folded) | 163 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Probe Shaft Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| Display | Single-line LCD with backlight |
| Power | 2 × AAA batteries (100 h life at +25 °C, no backlight) |
| Compliance | EN 13485, HACCP principles, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1052 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-20 to +100 °C), ±1.0 °C (-50 to -20.1 °C), ±1% of reading (+100.1 to +275 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| IP Rating | IP65 |
| Display | Backlit LCD (single-line) |
| Power Supply | LR44 button cell battery (80 h typical life) |
| Dimensions (with standard probe) | 148 × 38 × 195 mm |
| Weight (instrument only, standard probe) | 156 g |
| Response Time t₉₉ | 10 s (standard/long probe in liquid), 15 s (frozen goods probe in frozen meat ≈ 60 s) |
| Compliance | EN 13485, HACCP principles, FDA food safety guidelines |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model No. | 0563 1063 |
| Price Range | USD 0.15–750 (FOB) |
| Instrument Category | Insertion-Type Food Thermometer |
| Temperature Range | −50 °C to +275 °C |
| Accuracy | ±0.5 °C (within −20 °C to +50 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | −20 °C to +50 °C |
| Display | Integrated LCD (backlit) |
| Power Supply | 1 × CR2032 button cell (included) |
| Dimensions (L×W×H) | 215 mm × 34 mm × 19 mm |
| Weight | 80 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 1108 |
| Temperature Measurement Principle | NTC Thermistor |
| Measurement Type | Contact |
| Temperature Range | −50 to +150 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.2 °C (−20 to +80 °C), ±0.3 °C (remaining range) |
| Stability | Compliant with HACCP and EN 13485 requirements |
| Operating Environment | −20 to +50 °C |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 3340 |
| Channel Count | 2-channel |
| Compliance | DIN EN 12830:2018 |
| Communication | WLAN, LAN, testo UltraRange radio |
| Alarm | Visual LED alert |
| Software Integration | testo Saveris PRO / CFR, testo Saveris Cockpit |
| Certification | Validated for GxP environments (GLP/GMP-aligned) |
| Power | Battery-operated (included) |
| Mounting | Wall-mountable (included bracket) |
| Calibration | Supplied with traceable calibration protocol |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 3350 |
| Channel Count | Multi-channel |
| Certification | DIN EN 12830:2018 |
| Communication | WLAN, LAN, testo UltraRange radio |
| Alarm | Visual LED indicator (flashing) |
| Software Compatibility | testo Saveris PRO / CFR, testo Saveris Cockpit |
| Included | Wall mount bracket, batteries, calibration certificate |