| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9261 |
| Temperature Measurement Principle | Thermocouple (Type T, Type K compatible) |
| Measurement Method | Contact |
| Temperature Range | -50 to +400 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±0.3 °C (-20 to +70 °C) |
| Stability | ±0.3 °C (-20 to +70 °C) |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| IP Rating | IP65 (with optional protective sleeve) |
| Dimensions | 177 × 64 × 40 mm |
| Weight | 182 g (incl. 9 V battery) |
| Battery Life | 200 h (backlight off), 68 h (backlight on) |
| Compliance | EN 13485, HACCP principles, FDA-relevant food safety practices |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9261 |
| Temperature Measurement Principle | Thermocouple (Type T & K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +400 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±0.3 °C (-20 to +70 °C) |
| Stability | ±0.3 °C (-20 to +70 °C) |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| IP Rating | IP65 (with optional protective sleeve) |
| Dimensions | 177 × 64 × 40 mm |
| Weight | 182 g (incl. 9 V battery) |
| Battery Life | 200 h (backlight off), 68 h (backlight on) |
| Compliance | EN 13485, HACCP-ready |
| Data Logging | Max/Min auto-capture, user-defined alarm thresholds with audible alert |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0572 2166 |
| Input Interface | 4–20 mA / 0–10 V analog signals |
| Output Interface | Digital communication via TUC bus to testo 150 TUC4 Data Logger |
| Channel Capacity | Multi-channel (up to 8 analog inputs per coupler) |
| Compliance | Designed for GxP environments, supports audit trail-ready data acquisition per FDA 21 CFR Part 11 and EU Annex 11 requirements |
| Integration | Native component of testo Saveris Pharma platform |
| Communication | WLAN, LAN, or UltraRange radio-enabled via connected testo 150 TUC4 unit |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2034 |
| Channel Count | Single-channel |
| Temperature Range | −30 to +50 °C |
| Temp. Accuracy | ±0.5 °C |
| Temp. Resolution | 0.1 °C |
| RH Range | 0 to 100 %RH |
| RH Accuracy | ±2 %RH |
| RH Resolution | 0.1 %RH |
| Memory Capacity | 2 × 10,000 measurements |
| IP Rating | IP30 |
| Dimensions | 115 × 82 × 31 mm |
| Weight | 250 g |
| Power Supply | 4 × AA batteries (typical battery life: 24 months at +25 °C, 15-min interval) |
| Wireless Protocol | Wi-Fi (MQTT), supports WEP/WPA/WPA2/WPA2 Enterprise encryption |
| Time Sync | SNTP-capable |
| Operating Temperature | −30 to +50 °C |
| Storage Temperature (no battery) | −40 to +70 °C |
| Cloud Communication Interval | Basic license: fixed 15 min |
| Advanced license | adjustable from 1 min to 24 h |
| Measurement Interval | Basic: fixed 15 min |
| Advanced | adjustable from 1 min to 24 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2035 |
| Channel Count | Multi-channel |
| Measurement Range (Internal) | -30 to +50 °C, 0 to 100 %RH |
| Display | Integrated LCD |
| External Probe Interface | 1 x Pt1000 / capacitive humidity sensor (optional) |
| Memory Capacity | 2 × 10,000 readings |
| IP Rating | IP54 |
| Power Supply | 4 × AA batteries (typ. 24 months at 15-min interval, +25 °C) |
| Wireless Protocol | Wi-Fi (802.11 b/g/n), MQTT, SNTP time sync |
| Encryption | WEP / WPA / WPA2 / WPA2 Enterprise |
| Cloud Communication Interval | Basic: fixed 15 min |
| Advanced | adjustable 1 min – 24 h |
| Measurement Interval | Basic: fixed 15 min |
| Advanced | adjustable 1 min – 24 h |
| Data Retention (Cloud) | Basic: 3 months |
| Advanced | up to 24 months |
| Alarm Types | Upper/lower limit, delay alarm, system alarms (low battery, WLAN disconnection, power failure) |
| Notification Methods | Email (Basic & Advanced), SMS (Advanced only, 25 messages/year/device) |
| API Access | Yes |
| Compliance | Designed for GLP/GMP environments |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2031 |
| Channel Count | Single-channel |
| Measurement Range | −30 to +50 °C |
| Accuracy | ±0.5 °C |
| Resolution | 0.1 °C |
| Storage Capacity | 10,000 readings |
| IP Rating | IP65 |
| Battery | 4 × AA (24-month typical life at +25 °C, 15-min interval) |
| Wireless Protocol | MQTT over Wi-Fi (WEP/WPA/WPA2/WPA2 Enterprise supported) |
| Time Sync | SNTP-capable |
| Compliance | EN 12830 certified (TÜV-tested) |
| Cloud Communication Interval | 1 min – 24 h (Advanced license) |
| Operating Temperature | −30 to +50 °C |
| Dimensions | 95 × 75 × 30.5 mm |
| Weight | 240 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2103 |
| Channels | Dual-channel |
| Measurement Range | -50 to +150 °C |
| Accuracy | ±0.5 °C |
| Resolution | ±0.1 °C |
| IP Rating | IP65 |
| Weight | 240 g |
| Dimensions | 95 × 75 × 30.5 mm |
| Operating Temperature | -30 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Battery Life | Up to 12 months (typical, at +25 °C, 15-min measurement interval) |
| Memory Capacity | 10,000 data points |
| Power Supply | 4 × AA batteries (Energizer L91 recommended below -10 °C) |
| Compliance | EN 12830 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2032 |
| Channel Count | Multi-channel (2× NTC + 1× door contact) |
| IP Rating | IP65 |
| Compliance | DIN EN 12830 certified by TÜV |
| Measurement Range (NTC) | −50 to +150 °C |
| Accuracy | ±0.3 °C |
| Resolution | 0.1 °C |
| Memory Capacity | 2 × 10,000 values |
| Power Supply | 4× AA batteries (typical 24-month life at 25 °C, 15-min interval) |
| Operating Temperature | −30 to +50 °C |
| Storage Temperature (without battery) | −40 to +70 °C |
| Wireless Protocol | MQTT over WLAN (WEP/WPA/WPA2/WPA2 Enterprise supported) |
| Time Sync | SNTP-capable |
| Cloud Integration | testo Cloud (Basic free tier |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2033 |
| Channel Count | 2-channel |
| Communication | Wi-Fi (802.11 b/g/n), MQTT protocol, SNTP time sync |
| Enclosure Rating | IP54 |
| Operating Temperature | -30 to +50 °C |
| Storage Capacity | 2 × 10,000 measurements |
| Battery | 4 × AA (24-month typical life) |
| Thermocouple Types Supported | K, T, J |
| Temp. Range (K) | -195 to +1350 °C |
| Temp. Range (T) | -200 to +400 °C |
| Temp. Range (J) | -100 to +750 °C |
| Accuracy | ±(0.5 + 0.5 % of reading) °C |
| Resolution | 0.1 °C |
| Cloud Reporting | Basic (free, 3-month retention, 15-min interval) / Advanced (2-year retention, 1-min interval, SMS alerts, API, multi-user support) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 9320 |
| Channel Capacity | Up to 3,000 measurement channels |
| Power Backup | Integrated rechargeable emergency battery |
| Connectivity | Ethernet, Wi-Fi, testo UltraRange™ long-range encrypted radio (optional module) |
| Alarm Outputs | Visual alerts, email/SMS notifications, relay-triggered audible/visual alarms |
| Compliance | Designed for GxP environments (aligned with EU GMP Annex 15, FDA 21 CFR Part 11, ISO 14644, and ICH Q5C temperature/humidity monitoring requirements) |
| Included | Base unit, built-in rechargeable battery, charging cable |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Channel Type | Imported |
| Category | Multi-Channel Temperature & Humidity Data Logger and Controller |
| Compliance | Designed for HACCP, ISO 22000, and FDA Food Code compliance |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0646 0073 |
| Temperature Range | +116 to +138 °C |
| Accuracy | ±1.5 °C |
| Operating Ambient Temperature | +116 to +138 °C |
| Dimensions | 15 mm diameter |
| Weight | 1 g |
| Quantity per Pad | 10 units |
| Indication Points | +116, +122, +128, +132, +138 °C (customizable thresholds per variant) |
| Response Time | ≤3 seconds upon exceeding threshold |
| Irreversible Visual Indication | Yes |
| Compliance | CE-marked, RoHS-compliant, designed for industrial process monitoring and cold chain validation |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9313 01 |
| Channel Count | Multi-channel |
| Communication Protocols | UltraRange proprietary long-range radio, Ethernet, WLAN |
| Compliance | CE, RoHS, EN 300 328, EN 301 489 |
| Integration | Designed exclusively for testo 150 data logger platform |
| Enclosure Rating | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Power Supply | 12–24 V DC via testo 150 base unit |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 9310 |
| Channel Capacity | Up to 40 testo 150 data logger modules |
| Communication Interface | Ethernet (RJ45), UltraRange proprietary long-range wireless protocol (868 MHz, encrypted) |
| Power Supply | External (not included) |
| Compliance | CE, RoHS, EN 300 220-1, EN 301 489-1/17 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9313 02 |
| Channel Capacity | Multi-Channel |
| Compliance | CE, RoHS, FCC Part 15 Subpart C (for US deployment) |
| Operating Frequency | 868 MHz (EU), 915 MHz (US) |
| Max Line-of-Sight Range | Up to 2 km (outdoor, unobstructed) |
| Indoor Penetration | Up to 15 concrete floors or equivalent attenuation |
| Data Encryption | AES-128 |
| Protocol | Proprietary ultra-low-power TDMA-based mesh-capable radio protocol |
| Interface | SPI + UART for integration with testo 150 series data loggers |
| Firmware Upgradable | Yes, via Saveris Cloud or local gateway |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9320 |
| Communication Interface | IEEE 802.11 b/g/n (2.4 GHz) |
| Security Protocol | WPA2-PSK, TLS 1.2 |
| Operating Temperature | 0–50 °C |
| Humidity Range | 10–90 % RH non-condensing |
| Certifications | CE, FCC, IC, RCM |
| Integration | Plug-and-play with testo 150 modular system |
| Channel Capacity | Supports multi-channel environmental monitoring (temperature, humidity, CO₂, differential pressure, etc.) |
| Compliance | Designed for GxP environments |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 01STHE□ |
| Pricing | Available Upon Request |
| Accuracy | ±1 °C below 100 °C |
| Compliance | BS EN ISO 9001 certified |
| Dimensions | 12 × 13 mm per strip |
| Pack Size | 50 strips per pack |
| Format | Vertical self-adhesive format with dual-scale (°C and °F) markings |
| Temperature Range Options | 29–290 °C (discrete points: 29, 33, 34, 37, 40, 42, 43, 44, 46, 49, 54, 60, 62, 65, 71, 77, 82, 88, 93, 99, 104, 110, 116, 121, 127, 132, 138, 143, 149, 154, 160, 166, 171, 177, 182, 188, 193, 199, 204, 210, 216, 224, 232, 241, 249, 254, 260, 280, 290 °C) |
| Chemical Resistance | Oil-resistant and water-resistant |
| Toxicity | Non-hazardous, non-toxic formulation |
| Indication Mechanism | Irreversible thermochromic color transition (white → black) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DL6018 |
| Price Range | USD 7,000 – 14,000 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | DL6018 |
| AD Resolution | 16-bit |
| Input Channels | 16-channel differential voltage (expandable to 32) |
| Digital I/O | 16-channel isolated DI/DO |
| Operating Temperature | 0–50 °C |
| Power Supply | AC 100–240 V, 50–60 Hz |
| CPU | Intel dual-core quad-thread (3.0 GHz) |
| RAM | ≥2 GB |
| Storage | 500 GB SATA HDD (120 GB SSD optional) |
| Communication Interfaces | 10 RS-232/485 serial ports, 4× USB 2.0, 2× USB 3.0, 2× Gigabit Ethernet |
| Analog Input Ranges | 0–1 V, 0–5 V, 0–10 V, 4–20 mA |
| Overvoltage Protection | 250 V |
| Relay Output Capability | 650 mA @ 40 VDC (sourcing) or relay-contact rated |
| OS | Windows XP Professional (Chinese Edition) |
| Database Engine | Microsoft Access |
| Data Export Formats | CSV, TXT, XLSX, DBF |
| Remote Capabilities | Clock synchronization, calibration scheduling, real-time data polling via Modem/GSM/Ethernet |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp JKT |
| Price | Upon Request |
| Thermocouple Types | J, K, T |
| Temperature Range | –250 °C to 1372 °C (K-type), –250 °C to 400 °C (T-type), –2.00 °C to 1000 °C (J-type) |
| Resolution | 0.1 °C (–99.9 °C to 299.9 °C) |
| Accuracy | ±0.2% of reading + 0.5 °C (t > –99.9 °C) |
| Offset Adjustment | ±10 °C |
| Display | LCD |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Operating Temperature | –10 °C to 50 °C |
| Dimensions (unit) | 140 × 70 × 35 mm |
| Weight (unit) | 200 g |
| Input Connector | 2-pin ANSI mini thermocouple interface |
| Data Hold | Yes |
| Auto Power-Off | Yes |
| Low-Battery Indicator | Yes |
| Factory-Calibrated | Yes |
| Self-Diagnostic Functions | Yes |
| Key-Based Calibration | Yes |
| Power-Save Mode | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | Temp 10 |
| Pricing | Upon Request |
| Temperature Ranges | J-type: −210 to 1200 °C (−346 to 2192 °F), K-type: −250 to 1372 °C (−418 to 2501 °F), T-type: −250 to 400 °C (−418 to 725 °F) |
| Resolution | 0.1 °C/°F below 1000 °C/°F |
| Accuracy | ±0.25% of reading ±1 °C below −150 °C |
| Display | 58 × 40 mm backlit LCD, dual-line |
| Min/Max Hold | Yes |
| Auto Power-Off | 17.5 min (configurable) |
| Data Hold & Stability Indicator | Yes |
| Input | Single thermocouple channel |
| Power | 3 × AA 1.5 V alkaline batteries |
| Operating Environment | −40 to 65 °C, 10–90% RH (non-condensing) |
| Dimensions (bare) | 175 × 97 × 42 mm |
| Weight (bare) | 267 g |
| Dimensions (with protective case) | 180 × 102 × 52 mm |
| Weight (with case) | 362 g |
| Ingress Protection | IP54 per IEC 60529 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Temp 14 |
| Price | Upon Request |
| Measurement Range | -40 to 150 °C (-40.0 to 302.0 °F) |
| Resolution | 0.1 °C / 0.1 °F |
| Accuracy | ±0.2 °C (±0.4 °F) from -40 to 125 °C |
| Display | Backlit LCD, 58 × 40 mm |
| Min/Max Hold | Yes |
| Auto Power-Off | 17.5 min (configurable) |
| Data Hold & Stability Indicator | Yes |
| Input | Single-channel, 6.3 mm phone jack |
| Power | 3 × AA 1.5 V alkaline batteries (>750 h without backlight) |
| Operating Environment | -40 to 65 °C, 10–90 % RH (non-condensing) |
| Dimensions (without case) | 175 × 97 × 42 mm |
| Weight (without case) | 267 g |
| Dimensions (with case) | 180 × 102 × 52 mm |
| Weight (with case) | 362 g |
| Ingress Protection | IP54 per IEC 60529 |
| EMC Compliance | EN 61326-1/A1:1998 (EU EMC Directive) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Temp 16 |
| Price | Upon Request |
| Measurement Range | −200.0 to +850.0 °C (−392.0 to +1562.0 °F) |
| Resolution | 0.1 °C / 0.1 °F (−200.0–999.9), 1 °F (1000–1562) |
| Accuracy | ±2.0 °C (−200.0 to −100.0 °C), ±0.2 °C (−99.9 to +199.9 °C), ±2.0 °C (+200.0 to +850.0 °C) |
| Display | 58 × 40 mm backlit LCD, dual-line |
| Min/Max Hold | Yes |
| Auto Power-Off | 17.5 min (configurable) |
| Data Hold & Stability Indicator | Yes |
| Input | Single-channel 3-pin TA3F connector |
| Power | 3 × AA 1.5 V alkaline batteries (>750 h without backlight) |
| Operating Environment | −20 to +50 °C, 10–90 % RH (non-condensing) |
| Storage | −40 to +65 °C, 10–90 % RH |
| Dimensions (w/o case) | 175 × 97 × 42 mm |
| Weight (w/o case) | 267 g |
| Enclosure Rating | IP54 |
| Compliance | CE (EN 61326-1/A1:1998), IEC 529 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp 300 |
| Pricing | Upon Request |
| Thermocouple Types Supported | J, K, T, E, R, S, N, B |
| Temperature Range (Type K) | −250 °C to +1372 °C |
| Resolution | 0.1 °C/°F (−199.9 to 999.9 °C/°F) |
| Accuracy (J/K/T/E/N) | ±0.25 % of reading + 1 °C (above −150 °C) |
| Accuracy (R/S/B) | ±0.1 % of reading + 1 °C |
| Data Storage Capacity | 2,000 readings |
| Logging Interval | 1 s – 60 min |
| Display | 58 × 40 mm backlit LCD |
| Power | 3 × AA 1.5 V alkaline batteries (>750 h battery life, backlight off) |
| Dimensions (without case) | 175 × 97 × 42 mm |
| Weight (without case) | 267 g |
| Enclosure Rating (with probe connected) | IP54 |
| Compliance | CE (EN 61326-1/A1:1998), EMC Directive 2014/30/EU |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Temp 360-2 |
| Pricing | Upon Request |
| Measurement Range | −201 °C to 1210 °C (−330 °F to 2210 °F) |
| Resolution | 0.1 °C/°F (−330 to −100), 0.01 °C/°F (−99.99 to 99.9), 0.1 °C/°F (100 to 999.9), 1 °C/°F (>1000) |
| Accuracy | ±0.1 °C/±0.2 °F (−330 to −100), ±0.03 °C/±0.06 °F (−99.99 to 99.9), ±0.1 °C/±0.2 °F (100 to 999.9), ±1 °C/±2 °F (>1000) |
| Display | 58 × 40 mm backlit LCD, dual-line |
| Data Storage | 2000 readings |
| Logging Interval | 1 s – 60 min (programmable) |
| Max/Min/Diff Functions | Yes |
| Auto-Power-Off | 17.5 min (configurable) |
| Data Hold & Stability Indicator | Yes |
| Input Interface | 3-pin DIN connector |
| Environmental Storage | −40 °C to 65 °C (−40 °F to 149 °F) |
| Power Supply | Three AA 1.5 V alkaline batteries (>750 h without backlight) |
| Dimensions (L×W×H) | 175 × 97 × 42 mm (instrument only) |
| Weight | 267 g (instrument only) |
| Enclosure Rating | IP54 (with probe connected) |
| Compliance | CE-marked per EN 61326-1/A1:1998 (EU EMC Directive) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Versa Advantage & Box Series Checkweighers |
| Quotation | Upon Request |
| Belt Length Options | 300 / 400 / 500 mm |
| Maximum Throughput | Up to 200 ppm (application-dependent) |
| Compatible Packaging Types | Cartons, pouches, cups, bottles, cans, bags, boxes, and other rigid or flexible primary/secondary packages |
| Line Height Options | 650 / 700 / 750 / 800 / 850 / 900 mm |
| IP Rating Options | IP20 / IP65 |
| Conveyor Speed Range | Up to 70 m/min |
| Weight Capacity Range | 10 g – 3000 g (model-dependent) |
| Conveyor Width Options | 200 / 250 / 300 mm |
| Typical Accuracy | ≥ ±0.5 g (subject to package mass, belt stability, conveyor dynamics, roller configuration, and environmental conditions) |
| Display | 8-inch industrial-grade color touchscreen with embedded control computer |
| Unit Size | Each |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | DL6008 |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp 360 |
| Pricing | Available Upon Request |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-A |
| Temperature Range | -10°C to 160°C |
| Accuracy | ±0.07°C (-10°C to 160°C), ±0.1°F (14°F to 320°F) |
| Resolution | 0.01°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25" LCD |
| Power Supply | 3V CR2032 coin cell battery |
| Probe Length | 20 cm (8"), Probe Diameter: 6.35 mm (1/4"), Tip Diameter: 4.76 mm (3/16") |
| Enclosure | Anodized aluminum housing (3.5" × 12"), silicone-sealed |
| Weight | 93 g (3.3 oz) |
| Auto-off | After 20 minutes of inactivity or continuous operation |
| Units | Switchable °C / °F |
| Sensor Material | Stainless steel |
| Thermal Response Time (in water bath) | 14 seconds |
| Battery Life | ~400 hours at 21°C (70°F) |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-R |
| Temperature Range | -18°C to 150°C |
| Accuracy | ±0.04°C or ±0.07°F |
| Resolution | 0.001°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25-inch LCD |
| Power Supply | 3V CR2032 lithium coin cell |
| Probe Length | 20 cm (8 in), Diameter: 6.35 mm (1/4 in) |
| Weight | 124 g |
| Sensor Type | 200 Ω wound-wire Pt RTD |
| Immersion Depth | 11 cm (4 in) |
| Response Time | ≤3 min to ±0.1°C in water bath (0–50°C) |
| Auto-off | After 20 min idle or continuous operation |
| Units | Switchable °C/°F |
| Enclosure | Anodized aluminum housing (3.5" × 12"), silicone-sealed |
| Battery Life | 400 hours at 21°C (70°F) |