| Brand | TopOptics (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Model | XGL-1 |
| Output Wavelengths | 1064 nm & 532 nm |
| Beam Divergence | ≤5 mrad |
| Alignment Laser | 632.8 nm He–Ne |
| Electro-Optic Q-Switch Voltage Range | 1–5 kV (adjustable) |
| Pulse Energy | 600 mJ @ 1064 nm (free-running, no Q-switching) |
| Included Components | He–Ne alignment laser with power supply, λ/2 and polarizing optics for 1064 nm, Q-switch driver, HR/OC mirrors @ 1064 nm, iris diaphragm, water-cooling unit, Nd:YAG rod, flashlamp, KDP or BBO frequency-doubling crystal, LiNbO₃ or KD*P Q-switch crystal, beam target, elliptical pump cavity |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 4420 Series L-Type |
| Pricing | Upon Request |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | 4380 Series L-Type |
| Pricing | Upon Request |
| Dimensions (in/mm) | 2.86 × 6.36 in (72.64 × 162.54 mm) |
| Mass | 0.35 lb (0.159 kg) |
| Max Calibrated Equivalent Airspeed | 450 knots |
| Heating | Integrated heater for total pressure port |
| Aircraft Compatibility | Fixed-wing aircraft, rotary-wing aircraft, UAVs |
| Mechanical Interface | Requires AN5812 and AN5814 fittings |
| Documentation | CAD models and dimensional/technical specification PDF available |
| Brand | Roctest |
|---|---|
| Origin | Canada |
| Model | TPC |
| Output Options | Vibrating Wire (VW), 4–20 mA, 0–5 Vdc, Pneumatic, Fiber Optic |
| Construction | Hermetically sealed stainless steel housing filled with de-aired oil |
| Shape Options | Circular or Rectangular (for tangential/radial stress in shotcrete tunnel linings) |
| Mounting | Four integrated metal mounting rings |
| Temperature Sensing | Built-in thermistor |
| Environmental Rating | IP68 (VW version), Surge-protected (VW) |
| Compliance | ISRM Recommended Methods for Rock Stress Measurements |
| Stiffness | High (enabling embedment in soil/concrete), with peripheral grooves to reduce off-axis sensitivity |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Model | CURVE-X2 |
| Temperature Range | –50 °C to 1200 °C |
| Accuracy | ±0.3 °C |
| Resolution | 0.1 °C |
| Thermocouple Type | NiCr–Ni (Type K) |
| Probe Inputs | 6–12 channels |
| Operating Temperature | 0–60 °C |
| Sampling Interval | 1 second to 1 hour |
| Memory Capacity | 254,000 data points (10 user-definable groups, 25,000 points per group) |
| Power Supply | 3 × AA 1.5 V alkaline batteries (up to 1200 hours continuous logging) |
| Dimensions (Logger) | 30 × 105 × 85 mm (H × L × W) |
| Weight (Logger) | 285 g |
| Insulation Box Dimensions | 66 × 192 × 145 mm (H × L × W) |
| Insulation Box Weight | 1600 g |
| Predefined Coating Profiles | 15 |
| Curve-Index Calculation | Built-in |
| Display | Backlit graphical LCD |
| Auto-Start/Stop Triggers | Time/date-based or temperature-threshold-based |
| Software | Ideal Finish™ (included) |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | Hull Roughness Gauge |
| Accuracy | ±5 µm (±2% at 50 mm/s) |
| Scanning Speed | 50 mm/s |
| Data Storage | Up to 4 full measurement sessions (>10,000 individual readings) |
| Interface | USB-to-serial PC connection |
| Power Supply | 4 × AA batteries |
| Battery Life | 20 hours (backlight on), 200 hours (backlight off) |
| Operating Environment | Marine-grade portable design with IP-rated waterproof housing |
| User Interface | 4-way directional keypad for single-hand operation |
| Accessories | Integrated lanyard, rugged carry case |
| Brand | TQC Sheen |
|---|---|
| Origin | Netherlands |
| Model | SP1560 |
| Measurement Range | 0–3.4 mm (0–0.13 in) |
| Accuracy | ±5 µm (±0.2 mil) |
| Repeatability | 1 µm (±0.04 mil) |
| Probe Thread | M2.5 × 0.45 |
| Probe Shank Diameter | 8 mm (0.3 in) |
| Dual-Function Capability | Surface Roughness + Coating Thickness |
| Compliance | ASTM D4417, ISO 2808 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TRB3 |
| Pricing | Available Upon Request |
| Output Interface | SDI-12 Digital |
| Enclosure Rating | IP67 |
| Supply Voltage | 7–28 VDC |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity Range | 0–100 %RH |
| Temp. Accuracy | ±0.2–±0.3 °C (−40 to +70 °C) |
| RH Accuracy | ±1.5–±2 % (0–80 %RH) |
| Pressure Range | 300–1200 mbar |
| Pressure Accuracy | ±2 mbar (typ.) |
| Long-Term Drift | < 0.03 °C/yr, < 0.15 mbar/yr, ±0.5 %RH/yr |
| Resolution | 0.001 °C / 0.001 %RH / 0.001 mbar |
| Response Time | <130 s (Temp), 8 s (RH), N/A (Pressure) |
| Calibration Traceability | NIST and NPL |
| Brand | Trimos |
|---|---|
| Origin | Switzerland |
| Model | ALESTA |
| Measurement Range | 0.1–1015 mm |
| Resolution | 1 µm |
| Operating Environment | 22 °C ± 0.5 °C |
| Measurement Principle | Precision Mechanical Interpolation with Linear Encoder-Based Displacement Sensing |
| Key | Brand: Trimos |
|---|---|
| Origin | Switzerland |
| Model | HS |
| Measurement Range | 0–3050 mm |
| Resolution | 0.1 µm |
| Accuracy | ±0.1 µm |
| Operating Environment | 20 °C ± 0.5 °C |
| Measurement Principle | Absolute Interferometric Length Metrology (Long-Range Linear Encoder-Based) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Type | Analytical Balance |
| Capacity | 210 g / 60 g (dual-range) |
| Readability | 0.1 mg / 1 mg |
| Repeatability | ±0.1 mg / ±1 mg |
| Linearity | ±0.2 mg / ±2 mg |
| Calibration | External |
| Pan Diameter | Ø90 mm |
| Draft Shield Dimensions | 150 × 165 × 200 mm |
| Overall Dimensions | 365 × 223 × 338 mm |
| Compliance | ISO/IEC 17025-ready, GLP/GMP-supporting design |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | JJ100B / JJ200B |
| Instrument Type | Analytical Balance |
| Capacity | 110 g / 200 g |
| Readability | 0.001 g (1 mg) |
| Repeatability | ±0.001 g |
| Calibration Method | Manual internal calibration (100 g / 200 g standard weight required) |
| Pan Diameter | Ø105 mm |
| Dimensions (L×W×H) | 325 × 211 × 110 mm |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Operating Temperature | 0–40 °C |
| Operating Humidity | ≤80 % RH (non-condensing) |
| Interface | RS232 serial port |
| Tare Range | 0–110 g / 0–200 g |
| Verification Scale Interval (e) | 0.01 g (10d) |
| Construction | Aluminum alloy base with EMI-shielded internal housing |
| Features | Stainless steel weighing pan, 7-unit conversion (g, oz, ct, dwt, grain, lb, tl), piece counting (sample size: 1/10/20/50/100), underhook weighing capability, LCD display |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 5000 Series |
| Flow Principle | Thermal (Constant Temperature Anemometry) |
| Sensor Element | Platinum-coated Thin-film Sensor |
| Accuracy | ±2% or ±1.5% of reading (selectable) |
| Response Time | 4 ms (bidirectional) |
| Pressure Drop | Low, <100 Pa at full scale |
| Turndown Ratio | 1000:1 |
| Display | 2.8-inch color touchscreen |
| Gas Calibration Options | User-selectable for up to 6 gases |
| Simultaneous Parameters | Mass flow, absolute pressure, temperature, volumetric flow, differential pressure, relative humidity (optional) |
| Data Logging | Optional internal memory or PC-based via USB |
| Software | FLO-Sight PC software (standard) |
| Compliance | NIST-traceable calibration certificate included |
| Environmental Compensation | Temperature & pressure compensation standard |
| Connectivity | USB-C for power, data transfer, and firmware updates |
| Mechanical Interface | Adjustable tube fittings (multiple sizes available) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | FHC50 |
| Communication Protocols | BACnet®, LonWorks®, Modbus™ |
| Alarm Types | Visual, Audible, Remote |
| Mounting Options | Surface or Flush Mount |
| Actuator Response | Fast-acting |
| Sensor Integration | Sash Position Sensor + Wall-Mounted Face Velocity Sensor |
| Control Method | Linear Venturi Valve or Pressure-Independent Air Valve |
| Compliance Support | ASHRAE 110, ANSI Z9.5, EN 14175 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | FHC50 / FHM10 |
| Communication Protocols | BACnet®, LonWorks®, Modbus™ |
| Alarm Types | Visual, Audible, Remote |
| Installation Options | Surface-Mount or Flush-Mount |
| Sensor Integration | Sash Position, Face Velocity (via thermal anemometry), Static Pressure, Thermal Mass Flow |
| Compliance Support | ANSI/ASHRAE 110, EN 14175, ISO 10632, GLP-relevant audit trails via BMS integration |
| Output | 4–20 mA analog output (FHM10), relay outputs, digital status reporting |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 4046 |
| Flow Range | 2.5–300 L/min |
| Accuracy | ±2% of reading or ±0.05 STD L/min (whichever is greater) |
| Display | Real-time volumetric flow (temperature- and pressure-compensated) |
| Response Time | 4 ms |
| Dimensions | 183 × 64 × 53 mm |
| Weight | 0.5 kg |
| Power | 7.5 VDC ±1.5 V, peak current 300 mA |
| Warm-up Time | 1 min |
| Calibration | NIST-traceable certificate included |
| Compliance | NIOSH-approved primary calibration reference instrument |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 4146 |
| Flow Range | 0.01–20 L/min |
| Accuracy | ±2% of reading or ±0.05 STD L/min (whichever is greater) |
| Response Time | 4 ms |
| Dimensions | 127 mm × 50 mm × 32 mm |
| Weight | 0.8 kg |
| Power Supply | 7.5 VDC ±1.5 V, peak current 300 mA |
| Warm-up Time | 1 min |
| Temperature Compensation | Yes |
| Pressure Correction | Yes |
| NIST-Traceable Calibration Certificate | Included |
| NIOSH-Approved Primary Reference Standard | Yes |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 4146 / 4046 |
| Calibration Level | Primary (NIOSH-Recognized) |
| Flow Measurement Principle | Critical Orifice (Restriction-Type) |
| Accuracy | ±2% of reading |
| Certifications | NIST-traceable calibration certificate included |
| Power Source | Rechargeable battery |
| Portability | Handheld, lightweight design for field use |
| Compliance | Recognized as a Primary Reference Instrument by NIOSH for personal sampling pump calibration |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | RPC30 |
| Sensor Technology | Thermal Mass Flow-Based Differential Pressure Sensing |
| Compliance | ANSI/ASHRAE/ASHE Standard 170-2008, FGI Guidelines 2010, CDC Environmental Infection Control Guidelines, USP <797> |
| Alarm System | Dual visual (LED) and audible (85 dB @ 1 m), user-configurable delay |
| Input Support | Differential pressure (±125 Pa), temperature (–10 to 60 °C), relative humidity (0–100 % RH), volumetric airflow (4–20 mA or 0–10 V analog inputs) |
| Control Output | 0–10 V DC or 4–20 mA for damper/valve actuation |
| Display | Color touchscreen (4.3″, capacitive), icon-driven UI with real-time status visualization |
| Communication | BACnet MS/TP, Modbus RTU, optional BACnet/IP via gateway |
| Security | Password-protected configuration access (admin/user levels) |
| Operating Mode | Isolation (AII/PE/OR) ↔ Neutral (non-isolation) toggle via physical key switch |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | RPM10 |
| Sensor Technology | Thermal Mass Flow-Based Differential Pressure Sensing |
| Compliance | ANSI/ASHRAE/ASHE Standard 170-2008, FGI Guidelines 2010, CDC Environmental Infection Control Guidelines, USP <797> |
| Alarm Types | Visual (LED status ring + touchscreen icon) and Audible (adjustable threshold & delay) |
| Operating Modes | Isolation (AII/PE), Neutral/Non-Isolation |
| Interface | Local touch-screen programming, BACnet MS/TP or Modbus RTU (optional), physical mode toggle switch |
| Security | Password-protected configuration access |
| Display | Color LCD with intuitive status visualization (e.g., green = nominal, amber = warning, red = alarm) |
| Enclosure Rating | IP42 |
| Power | 24 VDC (PoE-compatible option available) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | RPM20 |
| Sensor Technology | Thermal Anemometer–Based Differential Pressure Sensing |
| Compliance | ANSI/ASHRAE/ASHE Standard 170-2008, FGI Guidelines 2010, CDC Environmental Infection Control Recommendations |
| Alarm Logic | Adjustable Delay, Dual-Stage Visual & Audible Alert |
| Display | Color Touchscreen with Status-Color-Coded Interface |
| Connectivity | BACnet MS/TP, Modbus RTU, Ethernet (Optional) |
| Input Channels | 2 Differential Pressure Ports + Optional Temp/RH Inputs |
| Configuration | Local Keypad + Password-Protected Setup |
| Operating Modes | Isolation (Negative/Positive), Neutral, Non-Isolation |
| Max Monitoring Zones | 2 Isolation Rooms + 1 Anteroom |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8636 |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Communication Protocol | MODBUS RTU (open standard) |
| Power Input | 120 VAC, output: 24 VAC |
| Sensor Type | Wall-mounted differential pressure transducer |
| Control Outputs | Dual analog (0–10 VDC or 4–20 mA) for supply & exhaust dampers, auxiliary outputs for heating/cooling control |
| Alarm Interface | Relay output with visual & audible alert |
| Enclosure Rating | NEMA 1 (indoor use) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–90 % RH (non-condensing) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8681 |
| Control Principle | Differential Pressure-Based Closed-Loop Airflow Balancing |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Communication Protocol | MODBUS RTU (Open Standard) |
| Power Input | 120 VAC → 24 VAC (included transformer) |
| Sensor Interface | Dedicated wall-mount differential pressure transducer (included) |
| Alarm Output | Relay + visual/audible indicators |
| Temperature Control Capability | Integrated supply air heating & volume modulation |
| Enclosure Type | Standalone DIN-rail or surface-mount controller |
| Software Integration | BMS-ready via RS-485 serial interface |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8682 |
| Communication Protocol | Modbus RTU (Open Standard) |
| Power Input | 120 VAC to 24 VAC, 25 VA |
| Control Outputs | Relay Alarm + Analog/Digital Interface |
| Sensor Compatibility | External Room Pressure Transducer (Optional) |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Integration | BMS via Modbus or LonWorks (Optional) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8682-ST |
| Control Channels | Up to 5 independent duct systems |
| Pressure Sensing | Differential pressure transducer input |
| Output Interfaces | Analog (4–20 mA / 0–10 V), Relay alarms, MODBUS RTU (RS-485) |
| Power Supply | 120 VAC to 24 VAC transformer included (25 VA) |
| Enclosure | NEMA 1 indoor-rated |
| Compliance | CE, RoHS |
| Software Integration | Compatible with BMS via open MODBUS protocol |
| Alarm Logic | Adjustable delay to suppress transient false alarms |
| Local Interface | Backlit keypad and LCD display with password-protected configuration |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LT880 |
| Pricing | Available Upon Request |
| Brand | TW (Shandong Tianwei Environmental Technology) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TW-WY1 |
| Measurement Principle | GNSS-based Real-Time Kinematic (RTK) Displacement Monitoring with Ultrasonic Auxiliary Sensor Integration |
| Static Accuracy (Differential Mode) | Horizontal ±(2.5 mm + 1 ppm), Vertical ±(5 mm + 1 ppm) |
| Antenna Type | Choke-Ring Antenna with Magnetic Absorbing Material |
| Communication Protocols | Modbus-RTU, RTCM3 v3.x |
| Data Output Interfaces | RS485 (ASCII & Modbus-RTU), TCP/HTTP/UDP |
| Power Supply | DC 10–15 V (sensor) |
| Operating Temperature | −40 °C to +85 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Enclosure Dimensions | Ø360 mm × H163 mm |
| Typical Power Consumption | 0.6 W (sensor + LoRa), 0.96 W (with cloud upload) |
| Compliance | Supports ISO/IEC 17025-aligned field calibration workflows, compatible with GLP/GMP data integrity requirements via audit-trail-enabled platform logging |
| Brand | TZTEK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VME222 |
| Operation Mode | Fully Automatic |
| Measurement Range | ≥200 × 200 × 200 mm |
| Encoders | 0.5 µm Industrial-Grade Linear Glass Scale |
| XY-Axis Speed | 500 mm/s |
| Z-Axis Speed | 100 mm/s |
| Optical Magnification | 25×–160× (Stepless Electronic Turret Recognition) |
| Camera | High-Resolution Color Industrial Digital Camera |
| Illumination System | Programmable 6-Ring 8-Zone LED Surface Illuminator, Adjustable LED Backlight, Coaxial Illumination Option |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | UMP-2 |
| Power Supply | 6–24 V DC |
| Current Consumption | 60 mA |
| Volumetric Water Content Range | 0–100 %vol |
| Accuracy (VWC) | ±2 %vol |
| Resolution (VWC) | 0.1 %vol |
| EC Range | 0.001–5 mS/cm (up to 40 mS/cm at reduced resolution) |
| EC Accuracy | ±1 % |
| Temperature Range | −40 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Output Signals | Three analog outputs (0–1 V for temperature, EC, and VWC respectively) + RS485 digital interface |
| Connector | M12 with 1.5 m integrated cable |
| Enclosure | Fully potted, IP68-rated |
| Installation | Direct burial or horizontal embedding |
| Brand | Akatsuki Technology |
|---|---|
| Origin | Japan |
| Model | UHV Cold Atom Cell |
| Vacuum Performance | <1×10⁻¹⁰ mbar (after bake-out) |
| Optical Access | ≥6 viewports (4 × Ø25.4 mm, 2 × Ø50.8 mm) |
| Flange Standard | CF-40 & CF-63 (ISO-KF optional) |
| Material | OFHC Copper body with 316L stainless steel endplates |
| Surface Roughness | Ra ≤ 0.2 µm (mirror-polished internal surfaces) |
| Coating | Dual-side dielectric anti-reflection (AR) coating (R < 0.25% @ 780 nm & 1064 nm) |
| Bake-out Compatibility | 250 °C sustained for 24 h |
| Leak Rate | ≤1×10⁻¹² mbar·L/s (He) |