| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | York Instrument |
| Type | DP-45 |
| Measurement Range | ±45° |
| Resolution | ±0.1° |
| Linearity | ±0.1° (0–10°), ±1.5% of reading (10–45°) |
| Repeatability | ±0.1° |
| Sensitivity Axis Error | <1% at tilt angles <45° |
| Power Supply | 9 V alkaline battery |
| Battery Life | ~100 hours |
| Operating Temperature | 0–65°C |
| Storage Temperature | −40–65°C |
| Weight | 349 g (12.3 oz) |
| Housing | Compact molded plastic enclosure |
| Reference Mode | Adjustable zero (floating reference) |
| Hold Function | Yes |
| Low-Battery Indication | LO BAT display at <7 V |
| Over-Range Indication | Flashing “OVER RANGE” beyond ±45° |
| Sign Convention | Minus sign (−) indicates counterclockwise deviation from reference |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC2000 |
| Control Principle | Electronic Pressure Control |
| Display Type | Digital |
| Pressure Control Range | 0.1–100 kPa |
| Accuracy | ±0.1 % FS |
| Integrated Automatic Pressure Source | Yes |
| Power Options | AC Adapter or Rechargeable Li-ion Battery |
| Zeroing | Automatic On Startup |
| Communication Interfaces | RS-232, USB |
| Compliance Certifications | Factory Calibration Certificate Included |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPC6050 |
| Pricing | Upon Request |
| Operating Principle | Electronic Pressure Control |
| Display | Digital |
| Control Stability | < 0.003 % FS (typical 0.001 % FS) |
| Pressure Range | –0.1 to 21 MPa |
| Control Response Time | < 10 s |
| Accuracy | ±0.01 % of reading (upper half of span, IS-50 compliant) |
| Uncertainty Budget | k=2, includes instrument intrinsic performance, reference standard uncertainty, long-term stability, environmental effects, zero-drift beyond auto-compensation range, and temperature influence |
| Calibration Interval | 180 days for gauge/absolute pressures ≤ 0.1 MPa and bidirectional ranges ≤ 1 MPa |
| Sensor Recommendation | Absolute pressure sensor preferred for pressure simulation to enable effective zero-point drift compensation |
| Brand | York Instrument |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC8000 |
| Operating Principle | Electronic Pressure Control |
| Display | Digital LCD with Capacitive Glass Touchscreen |
| Pressure Control Range | Up to 40 MPa |
| Control Stability | 0.002% FS |
| Pressure Types | Gauge (Positive/Negative), Absolute |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DataNet |
| Price | Upon Request |
| ADC Resolution | 16-bit |
| Input Channels | 4 analog/digital inputs per node |
| Wireless Protocol | Zigbee (IEEE 802.15.4) @ 2.4 GHz |
| Max RF Range (LoS) | 80 m (extendable to 800 m with repeaters) |
| Network Capacity | Up to 65,000 devices |
| Data Rate | 250 kbps |
| Security | 128-bit AES encryption |
| Memory | 59,000 samples per node |
| Sampling Interval | 1 s – 2 h (user-configurable) |
| Power | Rechargeable internal battery + external 12 VDC @ 2 A adapter |
| Operating Temperature | −20 °C to +50 °C |
| Certifications | CE, FCC |
| Compliance | RoHS, FCC Part 15, EN 300 328 |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | MSP5100 |
| Output Signal | Custom Analog or Digital (Configurable) |
| Power Supply | 5 VDC |
| Accuracy | ±0.25% FS (Combined Nonlinearity, Hysteresis, Repeatability) |
| Long-Term Stability | ±0.25% FS/year |
| Operating Temperature Range | -40°C to +125°C |
| Compensated Temperature Range | -20°C to +85°C |
| Burst Pressure | 5× Rated Pressure |
| Overpressure Limit | 2× Rated Pressure |
| Pressure Cycles | >10 Million |
| Vibration Resistance | ±20 g (per MIL-STD-810C, Method 514.2) |
| Shock Resistance | 50 g (½-sine pulse, per MIL-STD-202F, Method 213B) |
| EMC Compliance | EN 55022 Class A/B |
| Housing Material | Monolithic 17-4PH or 316 Stainless Steel |
| Sealing | All-Metal, Weld-Free, O-Ring-Free Hermetic Construction |
| Media Compatibility | Compatible with media compatible with 316L stainless steel |
| Weight | 82.2 g |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | NS-10AAL2-UFG |
| Output Type | Analog Voltage (0.15 V/°) & Temperature-Compensated |
| Measurement Principle | Electrolytic Capacitive Sensing |
| Axis Configuration | Dual-Axis (X/Y) |
| Full-Scale Range | ±10° |
| Resolution | 0.001° (typ.), 0.01° (min.) |
| Absolute Accuracy | ±0.08° to ±0.3° (within 0–50°C, temp.-compensated) |
| Nonlinearity | ≤1.5% FS |
| Cross-Axis Sensitivity | ≤0.15% FS |
| Temp. Drift | ≤8 mV/°C |
| Output Voltage Range | 0.3–4.7 V |
| Supply Voltage | 5 VDC ±5% |
| Operating Temp. | −40°C to +85°C |
| Storage Temp. | −40°C to +85°C |
| Weight | 20 g |
| Dimensions (W × D × H) | 45 × 45 × 14 mm (max. 20 mm height with mounting features) |
| Integrated Temperature Sensor | Yes |
| Mounting | PCB-mount (surface-mount compatible) |
| Vibration Resistance | High (designed for industrial mobile platforms) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | PTS 420 |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TO2-1 |
| Measurement Principle | Electrochemical Micro-Fuel-Cell |
| Detection Range (Trace) | 0–10 ppm to 0–10,000 ppm O₂ |
| Detection Range (Percent-Level) | 0–25% O₂ |
| Response Time (T90) | 13 s |
| Accuracy | ±2% of reading |
| Repeatability | ±0.5% |
| Temperature Coefficient | 2.5 %/°C |
| Operating Temperature | 0–50 °C |
| Storage Temperature | 0–45 °C |
| Recommended Flow Rate | 0.5–2 SCFH (0.24–0.94 L/min) |
| Humidity Range | 0–100% RH (non-condensing) |
| Expected Service Life | 15–21 months |
| Shelf Life | 3 months |
| Warranty | 6 months |
| Output Signal | 330–585 µA |
| Electrical Interface | Center Foil (Negative), Outer Foil (Positive) |
| Compliance | Compatible with ASTM D3764, ISO 8573-3, USP <915>, FDA 21 CFR Part 11 (when integrated into validated systems) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | YK160-162 |
| Price | Upon Request |
| Measurement Range | 0–1079.5 mm (across 60 standard configurations) |
| Dimensions (YK160) | 46.0 mm × 57.9 mm × 41.2 mm |
| Weight | 113 g |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model Range | YK173, YK174, YK175, YK176 |
| Pricing | Available Upon Request |
| Stroke Range | 0–165.1 mm (5 standard models) |
| Diameter × Length | 24.4 mm × 11.4 mm (YK170 reference) |
| Mass | 28 g (YK173) to 113 g (YK176) |
| Electrical Output | Analog voltage divider (0–V<sub>in</sub>) |
| Potentiometer Type | Single-turn, precision conductive plastic |
| Resistance | 5 kΩ ±10% |
| Mechanical/Electrical Travel | 340° |
| Linearity Error | ±0.5% FS max |
| Resolution | Theoretically infinite (analog continuous output) |
| Repeatability | < ±0.1% FS (AccuTrak™ hub design) |
| Operating Temperature | –65 °C to +125 °C (–85 °F to +257 °F) |
| Shock & Vibration | 100 g / 6 ms |
| Housing Material | Precision-machined anodized 2024 aluminum |
| Cable | 0.46 mm (0.018″) 7×7 stainless steel, min. tensile strength 177 N (40 lbf) |
| IP Rating | IP54 |
| Environmental Compliance | DO-160D (ED-14D), Category E1E1ABXHXFDXSAXXXXXXXXXX |
| Insulation Resistance | ≥1000 MΩ @ 500 VDC |
| Dielectric Withstand | 1000 VDC min |
| Tempco | ±400 ppm/°C max |
| Power Rating | 1.0 W @ 70 °C |
| Max Supply Voltage | 35 VDC |
| Max Supply Current | 12 mA |
| Output Smoothness | ≤0.1% FS |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | YK180-0803 Series |
| Range | 0–254.0 mm |
| Dimensions | 37.8 mm × 43.1 mm |
| Weight | 57 g |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC4000 |
| Operating Principle | Electronic Pressure Control |
| Display | Digital |
| Control Stability | < 0.005 % FS |
| Control Speed | < 10 s |
| Accuracy | 0.02 % of reading (50–100 % FS), 0.02 % of half-scale (0–50 % FS) |
| Pressure Range | –0.1 to 21 MPa |
| Uncertainty Budget | Expanded uncertainty (k = 2) per ISO/IEC 17025, incorporating sensor intrinsic performance, reference standard uncertainty, long-term drift, thermal effects, zero-shift beyond auto-compensation range, and environmental influences |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | DM9600P |
| Measurement Principle | Chilled-mirror hygrometry |
| Display | 7-inch capacitive touchscreen LCD with bilingual (EN/CN) UI |
| Control System | Digital fuzzy logic control with auto-balance dew point stabilization algorithm |
| Communication Interfaces | RS-485, USB 2.0 |
| Data Storage | SD card slot (up to 32 GB, FAT32 formatted) |
| Compliance | Designed per ISO 8503-1 (surface profile), ASTM E104 (controlled humidity environments), and aligned with calibration traceability requirements of ISO/IEC 17025 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YP1002 |
| Capacity | 0–100 g |
| Readability | 10 mg |
| Pan Diameter | 130 mm |
| Dimensions (W×D×H) | 320 × 280 × 150 mm |
| Power Supply | AC/DC dual-mode |
| Interface | RS232C serial output |
| Capacity | 2000 g |
|---|---|
| Readability | 0.1 g |
| Repeatability | ±0.1 g |
| Linearity | ±0.2 g |
| Pan Dimensions | 188 × 160 mm |
| Overall Dimensions | 270 × 190 × 75 mm |
| Power | AC adapter or 9 V DC battery |
| Interface | RS232 |
| Features | Auto-calibration, tare, counting mode, unit conversion, backlit LCD, level indicator, all-range tare, single-key operation |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | YP20K-1 |
| Price | USD 605 (approx.) |
| Capacity | 20 kg |
| Readability | 0.1 g |
| Repeatability | ±0.1 g |
| Linearity | ±0.2 g |
| Dimensions (W×D×H) | 310 × 285 × 100 mm |
| Pan Size | 238 × 286 mm |
| Power | AC adapter or 9 V DC battery |
| Display | Backlit LCD |
| Interface | RS232 |
| Features | Auto-calibration, full-range tare, piece counting, unit conversion, level indicator, one-key function activation |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | YPQYQ-6 |
| Pricing | Upon Request |
| Brand | YSI |
|---|---|
| Origin | USA |
| Model | 600LS |
| Measurement Principle | Ventilated Piezoresistive Pressure Transduction |
| Water Level Range | 0–9 m |
| Resolution | 0.001 m |
| Accuracy | ±0.003 m (0–3 m), ±0.018 m (3–9 m) |
| Temperature Range | –5 to +60 °C |
| Temp. Resolution | 0.01 °C |
| Temp. Accuracy | ±0.15 °C |
| Conductivity Range | 0–100 mS/cm |
| Cond. Resolution | 0.001–0.1 mS/cm (range-dependent) |
| Cond. Accuracy | ±0.5% of reading + 0.001 mS/cm |
| Salinity Range | 0–70 ppt |
| Salinity Resolution | 0.01 ppt |
| Salinity Accuracy | ±1.0% of reading or ±0.1 ppt (whichever is greater) |
| Memory Capacity | 150,000 readings |
| Data Logging Interval | User-programmable |
| Communication Interface | SDI-12 |
| Max Operating Depth | 9 m |
| Compatible Platforms | YSI 650MDS, YSI 6200 Data Collection System, third-party SDI-12 loggers |
| Brand | YSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FlowTracker2 |
| Price Range | USD 13,500–40,500 (est.) |
| Technology | Acoustic Doppler Velocimetry (ADV) |
| Velocity Range | 0.001–4.0 m/s |
| Resolution | 0.0001 m/s |
| Accuracy | ±1% of measured velocity or ±0.0025 m/s (whichever is greater) |
| Minimum Measurement Depth | 0.02 m |
| Operating Temperature (Probe) | –20 °C to 50 °C |
| Operating Temperature (Display Unit) | –20 °C to 60 °C |
| Storage Temperature | –30 °C to 70 °C |
| Power Supply | 8 × AA batteries (alkaline/NiMH/NiCd), 8–12 V DC |
| Weight | 1.55 kg |
| Display IP Rating | IP67 (1 m submersion for 30 min) |
| Integrated Sensors | Tilt & orientation sensor, GPS receiver, Bluetooth 4.2 LE |
| Display | Color TFT touchscreen, graphical UI |
| Probe–Handle Interchangeability | Yes |
| Data Output | CSV, Excel-compatible, time-series and profile plots |
| Compliance | ISO 748, ISO 10721, USGS TWRI 3-A17, ASTM D5389 |
| Brand | YSI |
|---|---|
| Origin | USA |
| Model | ProSwap-Logger |
| Power | Internal rechargeable battery (integrated) + optional external 6×AA battery pack for extended deployment |
| Communication Protocols | SDI-12, Modbus RTU (configurable via firmware) |
| Interface | USB-C for data download, charging, and Kor software connectivity |
| Display | Compatible with YSI ProSwap handheld (color LCD) and ProDSS handheld |
| Software | Kor v3.x (Windows/macOS) with GLP-compliant audit trail, metadata tagging, and automated calibration logging |
| Environmental Rating | IP67-rated housing (submersible to 10 m for 30 min) |
| Operating Temperature | –20 °C to +50 °C |
| Data Storage | Internal 16 MB non-volatile memory (supports >1 million readings) |
| Sampling Interval | Configurable from 1 second to 180 days |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN2000 mm |
| Flow Velocity Range | 0.1–15 m/s |
| Minimum Fluid Conductivity | ≥5 μS/cm |
| Accuracy Class | ±1.0% of reading |
| Lining Materials | PTFE or rubber (selectable) |
| Electrode Materials | 316L stainless steel or Hastelloy (selectable) |
| Rated Working Pressure | ≤0.6 MPa |
| Temperature Range | –20 to +60 °C (rubber lining) |
| Protection Rating | IP65 (IP68 optional) |
| Power Supply | AC 220 V / DC 24 V |
| Output Signals | 4–20 mA analog output |
| Connection | Flanged, compliant with GB/T 11988 |
| Straight Pipe Requirements | ≥5DN upstream, ≥2DN downstream |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN25 mm |
| Lining Material | F46 (Fluorinated Ethylene Propylene, FEP) |
| Flow Range | 0.01–6 m³/h |
| Nominal Pressure | 1.6 MPa |
| Medium Temperature | −40 °C to +180 °C (remote transmitter configuration) |
| Ambient Temperature | −25 °C to +60 °C |
| Minimum Conductivity | ≥20 µS/cm |
| Sensor Protection Rating | IP65 |
| Accuracy | ±0.5% of Full Scale (FS) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL (DN50) |
| Nominal Pipe Size | DN50 (50–55 mm ID, adjustable insertion depth) |
| Flow Velocity Range | 0.1–10 m/s |
| Volumetric Flow Range (full pipe, DN50) | 0.000785–0.0785 m³/h |
| Accuracy | ±0.5% FS (standard conditions), ±1.0% FS (challenging conditions, e.g., low-conductivity or particulate-laden fluids) |
| Minimum Fluid Conductivity | ≥5 µS/cm |
| Operating Temperature | –20°C to +150°C |
| Max Working Pressure | 1.6 MPa |
| Electrode Materials | 316L stainless steel (standard), Hastelloy C-276 (corrosive media), Titanium (ultra-pure applications) |
| Lining Materials | PTFE (chemical resistance, high-temp), Neoprene rubber (abrasion resistance, wastewater) |
| Output Signals | 4–20 mA DC (analog), RS485 (Modbus RTU) |
| Power Supply | 220 V AC or 24 V DC |
| Sensor Protection Rating | IP65 (indoor/outdoor non-submersible), optional IP68 (submersible) |
| Ambient Operating Conditions | –25°C to +60°C, ≤95% RH (non-condensing) |
| Long-Term Drift | ≤0.1% FS/year |
| Repeatability | ≤0.2% FS |
| Excitation Method | Low-frequency rectangular wave magnetic excitation |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Pipe Size Range | DN10–DN3000 |
| Flow Velocity Range | 0.1–10 m/s |
| Accuracy | ±0.5% FS (standard), ±1.0% FS (challenging conditions) |
| Operating Pressure | PN1.0 MPa / PN1.6 MPa (customizable) |
| Medium Temperature | −20°C to +180°C (standard liner) |
| Minimum Conductivity | ≥5 µS/cm |
| Electrode Materials | 316L stainless steel, Hastelloy C, titanium |
| Liner Materials | PTFE, neoprene, polyurethane |
| Output Signals | 4–20 mA analog, RS485 (Modbus RTU) |
| Sensor Protection Rating | IP67/IP68 |
| Converter Protection Rating | IP65 |
| Power Supply | AC 220 V ±10% 50/60 Hz or DC 24 V ±10% |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN800 |
| Measurement Principle | Faraday’s Law of Electromagnetic Induction |
| Flow Velocity Range | 0.01–10 m/s |
| Accuracy | ±0.5% FS (optional ±1.0% FS) |
| Medium Conductivity | ≥5 µS/cm |
| Temperature Range | –20 to +180 °C (dependent on liner material) |
| Pressure Rating | 0.6–4.0 MPa |
| Liner Material | PTFE |
| Electrode Material | 316L Stainless Steel |
| Enclosure Protection | IP65 |
| Output Signals | 4–20 mA analog, pulse output |
| Communication Interface | RS485 (Modbus RTU) |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Wetted Materials Compliance | FDA-compliant PTFE liner per ASTM D1711 |
| Electromagnetic Compatibility | IEC 61326-1 (Industrial Environment) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN250 |
| Measurement Principle | Faraday’s Law of Electromagnetic Induction |
| Flow Velocity Range | 0.1–10 m/s |
| Volumetric Flow Range | 17.66–176.25 m³/h |
| Accuracy Class | ±0.5% of reading |
| Turndown Ratio | 100:1 |
| Minimum Conductivity | ≥5 µS/cm |
| Max. Working Pressure | 1.6 MPa |
| Process Temperature Range | –20°C to +80°C (standard) |
| Ambient Temperature Range | Sensor: –40°C to +80°C |
| Converter | –15°C to +50°C |
| Enclosure Rating | IP65 (integrated unit) |
| Output Signals | 4–20 mA (load ≤750 Ω), RS485 with Modbus RTU protocol |
| Power Supply | 220 VAC ±10%, 50 Hz ±1 Hz or 24 VDC ±10% |
| Lining Material | PTFE (polytetrafluoroethylene) |
| Electrode Material | 316L stainless steel (customizable) |
| Connection | GB/T 9119–2010 flanged (equivalent to EN 1092-1/DIN 2501/ANSI B16.5 Class 150) |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Diameter | DN40 |
| Flow Range | 0.5–50 m³/h |
| Accuracy | ±0.3% of reading (flow velocity ≥1 m/s) |
| Minimum Conductivity | ≥5 µS/cm |
| Nominal Pressure | 4.0 MPa |
| Operating Temperature | Sensor: −25°C to +60°C |
| Converter/Integral Unit | −10°C to +60°C |
| Lining Material | PTFE (Polytetrafluoroethylene) |
| Electrode Material | Stainless Steel 0Cr18Ni12Mo2Ti |
| Protection Rating | IP65 |
| Output Signals | 4–20 mA analog output |
| Compliance Standard | JB/T 9248–1999 |
| Brand | YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST183F-A50XL |
| Nominal Pipe Size | DN50 (50–55 mm ID) |
| Flow Velocity Range | 0.1–10 m/s |
| Volumetric Flow Range (DN50 full pipe) | 0.000785–0.0785 m³/h |
| Accuracy | ±0.5% FS (standard conditions), ±1.0% FS (with suspended solids) |
| Conductivity Requirement | ≥5 μS/cm |
| Operating Temperature | −20°C to +150°C (medium), −25°C to +60°C (ambient) |
| Max Working Pressure | ≤1.6 MPa |
| Electrode Materials | 316L stainless steel (standard), Hastelloy C-276, titanium |
| Lining Materials | PTFE (acid/alkali/heat resistant), chloroprene rubber (abrasion resistant, for wastewater) |
| Output Signals | 4–20 mA DC analog, RS485 Modbus RTU |
| Power Supply | 220 V AC or 24 V DC |
| Enclosure Rating | IP65 (standard), IP68 (optional, submersible) |
| Relative Humidity | ≤95% RH (non-condensing) |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST305SBCS1 |
| Pipe Diameter Range | DN50–DN3000 |
| Flow Velocity Range | 0.1–10 m/s |
| Medium Temperature | −20 °C to +80 °C |
| Max Working Pressure | ≤1.6 MPa |
| Output | 4–20 mA (250–750 Ω load), RS485 (Modbus RTU) |
| Power Supply | AC 220 V ±10% (50/60 Hz) or DC 24 V ±15% |
| Display | Backlit LCD showing instantaneous flow, cumulative flow, velocity, and medium temperature |
| Compliance | Suitable for fire protection water systems per NFPA 13 / ISO 6946 principles (non-intrusive installation, no pressure loss) |
| Material Compatibility | Carbon steel, stainless steel, cast iron, PVC, PE (wall thickness ≤20 mm) |
| Medium Requirements | Homogeneous, single-phase, low-viscosity liquids (e.g., potable water, fire service water) |