Measurement Instruments
Filter
Showing 2701–2711 of 2711 results
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | LZ22A |
| Price Range | USD 14,000 – 70,000 |
| Tank Dimensions (L×W×H) | 680 mm × 65 mm × 680 mm |
| Sample Area Range | 10 cm × 40 cm to 68 cm × 68 cm |
| Conductivity Resolution | 0.001 µS/cm |
| Conductivity Range | 0.001–20 µS/cm (equivalent to NaCl contamination: 300–10,000 µg/cm²) |
| Measurement Accuracy | ±5% |
| Extractant Specific Gravity | 0.80–0.855 |
| Electrode Temperature Compensation | Integrated real-time compensation |
| Test Modes | Dynamic and Static extraction |
| Resin System | Mixed-bed anion/cation exchange resin |
| Extraction Method | Heated solvent circulation with high-velocity rinse |
| Net Weight | ≈180 kg |
| Compliance | Designed for IPC-J-STD-001, IPC-TM-650 2.3.25, and MIL-STD-2000A pre-qualification workflows |
| Software | Onboard touchscreen interface with audit-trail-capable data logging |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | QQ1000 |
| Price Range | USD 14,000 – 72,000 (FOB Guangdong) |
| Measurement Accuracy | ±0.15 mm (verified with calibrated gauge blocks) |
| Inspection Speed | 6.5 m/min or 12.5 m/min (configurable) |
| PCB Thickness Range | 0.5–5.0 mm |
| Warpage Detection Range | 0.3–5.0 mm |
| Minimum Board Size | 40 mm × 80 mm |
| Maximum Board Size | 480 mm × 500 mm |
| Machine Dimensions | 3510 mm × 1160 mm × 1050 mm (L×W×H) |
| Weight | 450 kg |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | QQ1000 |
| Price Range | USD 14,000 – 72,000 |
| Measurement Principle | Non-contact laser triangulation with dual-sensor array |
| Measurement Accuracy | ±0.15 mm (verified against NIST-traceable gauge blocks) |
| Max. Conveyor Speed | 12.5 m/min |
| Measurable Board Thickness | 0.5–5.0 mm |
| Detectable Warpage/Bow Range | 0.3–5.0 mm |
| Supported PCB Dimensions | 40 mm × 80 mm to 480 mm × 500 mm |
| System Footprint | 3510 mm × 1160 mm × 1050 mm (L×W×H) |
| Weight | 450 kg |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | QY221 |
| Price Range | USD 7,000 – 14,000 |
| Sampling Dimension Range | 5 × 5 × 0.5 to 50 × 50 mm (L × W × H) |
| Max Sample Width | 508 mm |
| Min Sample Size | 120 × 100 mm |
| Sampling Thickness | 0.5–8 mm |
| Throat Depth | 280 mm |
| Cutting Tool Diameter | Φ2.0 mm / Φ2.4 mm |
| Rated Power/Voltage/Frequency | 1500 W / AC 220 V / 50 Hz |
| Current Rating | 10 A |
| Overall Dimensions (L×W×H) | 740 × 625 × 138 mm |
| Pneumatic Supply Pressure | 0.6–0.8 MPa |
| Net Weight | 190 kg |
| Brand | Zhongruixiang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ZRX-29212 |
| Price | USD 28.50 (FOB) |
| Vibration Acceleration Range | 0.1–205.6 m/s² (peak) |
| Velocity Range | 0.1–400.0 mm/s (RMS) |
| Displacement Range | 0.001–9.000 mm (p-p) |
| Frequency Range Options | 10–200 Hz / 10–500 Hz / 10–1 kHz / 10–10 kHz |
| Vibration Accuracy | ±5% |
| Spectral Resolution | 0.25 Hz |
| RPM Measurement | 30–300,000 rpm (5–5 kHz) |
| RPM Accuracy | ±(0.05% + 1 count) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80% RH |
| Display | 320 × 200 pixel TFT color LCD |
| Data Storage | 800 measurement records + 100 spectral plots |
| Communication | Mini-USB |
| Built-in Thermal Printer | Yes |
| Battery | 1500 mAh Li-ion, 50 h continuous operation |
| Dimensions | 212 × 80 × 35 mm |
| Weight | 320 g |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ZLPID-201 |
| Price Range | USD 700 – 1,400 (FOB) |
| Detection Range | 0–100,000 ppm (configurable spans) |
| Detection Limit | 1 ppb (typical, for isobutylene) |
| Response Time (T90) | ≤5 s |
| Operating Voltage | 3–5 V DC |
| Output Signal | 0.02–2.0 V (max 3.3 V) |
| Humidity Range | 0–99% RH (non-condensing) |
| Operating Temperature | −40 to +60 °C |
| Storage Temperature | 0 to +25 °C |
| Pressure Range | 800–1200 mbar |
| Zero Voltage (U₀) | >20 mV |
| Sensitivity | ≥40 mV/ppm (at low range, e.g., 0–100 ppm) down to ≥0.1 mV/ppm (at high range, e.g., 10,000–100,000 ppm) |
| Lifetime | >24 months (typical continuous operation) |
| Calibration Gas Recommendation | Isobutylene at ~50% of full scale |
| Compliance | RoHS-compliant construction |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DCS300PA |
| Price Range | USD 1–4,999 |
| Input Voltage Range (V) | ±1 mV to ±10 V |
| Input Current Range (I) | ±1 mA to ±10 mA |
| Auxiliary Input | DC 0–10 V |
| Voltage Gain | 10⁰–10⁴ |
| Current Gain | 10³–10⁷ |
| Integration Time | 10 µs–10 s |
| RAM Buffer Depth | ≤2,000 samples |
| Temperature Input | AD950 sensor, −30 °C to +100 °C |
| A/D Resolution | 16-bit |
| D/A Outputs | 2 channels, 0–10 V, 12-bit resolution |
| Trigger Input | TTL rising-edge |
| Trigger Output | TTL-compatible, for shutter/solenoid control |
| Digital I/O | 5 inputs, 2 TTL outputs |
| Interface | USB 2.0 |
| Certification | CE |
| Power Supply | AC 100–240 V, 50/60 Hz → DC 24 V / 0.3 A |
| Dimensions (L×W×H) | 260 × 260 × 120 mm |
| Weight | 3.3 kg |
| Brand | ZOLIX |
|---|---|
| Model | HawkEye-1300 |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (OEM & ODM Capable) |
| Type | Portable 3D Surface Profilometer |
| Measurement Principle | Spectral Confocal Line Scanning |
| Vertical Resolution | 1 µm |
| Vertical Repeatability | ±0.3 µm |
| Scan Width | 6.5 mm (selectable) |
| Z-Axis Range | 1.3 mm |
| Maximum Line Scan Rate | 1000 lines/s |
| Weight | 5 kg |
| Dimensions | 460 × 300 × 140 mm |
| Compliance | CE-marked for industrial lab use |
| Software Interface | SDK-supported (C/C++, Python, LabVIEW) |
| Brand | ZYGO |
|---|---|
| Origin | USA |
| Model | ZeGage Pro |
| Type | Non-Contact Profilometer / Surface Roughness Analyzer |
| Measurement Principle | Coherence Scanning Interferometry (CSI) |
| Compliance | ASTM E2947, ISO 25178-2, ISO 4287, ISO 10360-5 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZY-YL |
| Measurement Range | 0–5 mm/min |
| Accuracy | ±0.2 mm |
| Resolution | 0.1 mm |
| Measurement Error | ±2% |
| Recording Interval | 1 min – 24 h (user-configurable) |
| Memory Capacity | 16 MB (supports ≥10 years of continuous logging at 1-min interval) |
| Data Export | USB interface |
| Orifice Diameter | φ200 mm |
| Housing Material | High-grade ABS engineering plastic |
| Power Supply | Integrated lithium battery (rated service life: 3–5 years) |
| Operating Temperature | −40 °C to +70 °C (non-freezing conditions) |
| Compliance | Designed for long-term unattended field deployment without external power or communication infrastructure |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYKX-20 |
| Price Range | USD 1,400–7,000 (FOB) |
| Instrument Type | Online Continuous Monitoring System |
| Measurement Resolution | 0.1 °C |
| Accuracy | ≤ ±0.3 °C |
| Temperature Range | 33 °C to 43 °C (configurable alarm threshold) |
| Measurement Site | Forehead or wrist |
| Response Time | ≤ 1 s |
| Operating Ambient Temperature | 10 °C to 40 °C |
| Relative Humidity Limit | ≤ 85 % RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| External Frame Dimensions (H×W×D) | 2200 mm × 830 mm × 300 mm |
| Passage Opening (H×W×D) | 1920 mm × 700 mm × 300 mm |
| Installation Method | Tool-free quick-connect modular assembly |