| Brand | 3M |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MLSII |
| Pricing | Available Upon Request |
| Brand | Autobio |
|---|---|
| Model | Autof MS |
| Origin | Henan, China |
| Laser Lifetime | >100 million shots |
| Mass Analyzer | Titanium Alloy Linear TOF (1.05 m) |
| Vacuum System | High-Throughput Turbo-Molecular Pump |
| Identification Speed | ≤0.1 s per sample (database search) |
| Microbial Database | 5,000+ species across 1,000+ genera, including filamentous fungi, anaerobic gut bacteria, and marine isolates |
| Nucleic Acid Detection Capacity | Up to 40-plex per well |
| Regulatory Certification | NMPA-approved calibration and control materials |
| Software Compliance | Audit trail, user access control, and electronic signature support per FDA 21 CFR Part 11 requirements |
| Brand | Autobio |
|---|---|
| Model | Autof ms2000 |
| Origin | Henan, China |
| Laser Source | Solid-state, ≥10⁹ shots lifetime, 1–1000 Hz tunable frequency |
| Ion Source Vacuum | ≤10⁻⁷ mbar |
| Ion Source Maintenance | Auto-cleaning cycle ≤10 min |
| Mass Analyzer | Titanium alloy flight tube with high thermal stability |
| Vacuum System | High-throughput turbomolecular pump |
| Signal Acquisition | High-precision FPGA-controlled real-time digitizer |
| Software Platform | AI-accelerated microbial identification engine (96 samples in <5 min) |
| Database Coverage | >1,000 genera, >5,000 species, >16,000 strains |
| Regulatory Status | CE-IVD compliant |
| Data Security | On-premise and cloud-deployable database options |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Autostreak S1800 |
| Price Range | USD 140,000 – 210,000 (FOB) |
| Instrument Type | Fully Automated |
| Sample Type | Liquid (including sputum, broth cultures, urine supernatants) |
| Throughput | 180 Petri Dishes per Hour |
| Liquefaction Time | ≤5 min (sputum) |
| Streaking Time | ≤60 sec per 3 plates |
| Biosafety Level | Integrated Class II Biological Safety Cabinet Architecture |
| Filtration | HEPA H14 (99.995% @ 0.3 µm) |
| Decontamination | Automated UV-C (254 nm) cycle with timer-based scheduling |
| Consumables | Disposable sterile tips and single-use inoculation brushes |
| LIS Integration | ASTM E1384 / HL7 v2.x compliant interface |
| Software Compliance | Audit trail, user access control, electronic signature support per FDA 21 CFR Part 11 requirements |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Clin-TOF-I |
| Price Range | USD 140,000 – 280,000 |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | Elite Sealer-1 |
| Detection Method | Culture-based Enzyme Substrate Method |
| Instrument Type | Semi-Automatic |
| Target Analytes | Total Coliforms, *Escherichia coli*, Thermotolerant Coliforms (Fecal Coliforms) |
| Sample Types | Drinking Water, Surface Water, Wastewater |
| Sealing Capacity | <14 sec per 51-well or 97-well Quanti-Tray®-style tray |
| Operating Noise | <48 dB(A) |
| External Casing Temperature | <40°C |
| Preheat Time | ~4 minutes |
| Service Life | >50,000 sealing cycles |
| Compliance Standards | GB/T 5750, HJ 1001 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ET1500 |
| Price | Upon Request |
| Dynamic Range | ≥10⁶ |
| Sample Tube Dimensions | Ø12 mm, Height 47–75 mm |
| Communication Interface | RS232C |
| Measurement Duration | 0–99 s (1 s increments) |
| Data Storage Capacity | ≥2000 test records |
| Operating Temperature | 15–40 °C |
| Display | Backlit LCD |
| Power Supply | 220 V ±10 %, 50 Hz, 35 W |
| Rechargeable Battery | 3.7 V, 5000 mAh |
| Operating Humidity | 10–90 % RH (non-condensing) |
| Dimensions (L×W×H) | 320 × 170 × 180 mm |
| Weight | 2 kg (including battery) |
| Brand | AMAE (Shenzhen Guoji) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Fully Automated |
| Detection Target | Dispersed/Field-Based Bacterial Pathogens |
| Sample Type | Swab, Environmental Water, Food Homogenate, or Clinical Specimen (pre-extracted nucleic acid) |
| Detection Time | ≤25 min |
| Throughput | 6 samples per run |
| Dimensions | Compact and Field-Portable (≤300 × 220 × 180 mm) |
| Detection Principle | Isothermal LAMP Amplification Coupled with PSFN Nanoparticle-Based Visual & Optical Aggregation Readout |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HD-AO10 |
| Pricing | Upon Request |
| Measurement Principle | Fluorescence Quenching (Non-Consumptive, Optical) |
| Oxygen Range | 0–25% O₂ (v/v) |
| Accuracy | ≤ ±2% FS |
| Temperature & Humidity Sensing | Integrated |
| Channel Scalability | Multi-channel expandable (up to 5 concurrent sensor inputs) |
| Power | Rechargeable Li-ion battery |
| Sensor Lifetime | ≥2 years (typical operational service life) |
| Display | ≥4-inch capacitive touchscreen |
| Processor | Dual-core architecture (ARM Cortex-M3 + high-speed FPGA) |
| Data Storage | Internal flash + microSD card (user-replaceable) |
| Communication | Modbus RTU over RS-485 |
| Calibration | Automatic on-power-up oxygen zero/span calibration support |
| Alarm Function | User-configurable high/low O₂ thresholds with timestamped event logging |
| Data Visualization | Real-time trend curves (O₂%, temperature, humidity) with exportable CSV format |
| Compliance | Designed for GLP-compliant laboratory workflows |
| Brand | HuaDuanBio |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-ST20 |
| Price | Upon Request |
| Center Zone Temperature | 925 °C ±25 °C |
| Heating Zone Outer Diameter | φ15 mm |
| Heating Zone Length | 150 mm |
| Warm-up Time | ≤15 min |
| Standby Mode | Adjustable保温 setting for energy-efficient standby |
| Fuse Rating | 250 V, 3 A, 5×20 mm |
| Input Power | AC 220 V, 50–60 Hz, 150 W |
| Dimensions (W×D×H) | ≤120×155×180 mm |
| Standard Configuration | 1 × sterilizer main unit |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MBS (Fitlylab) |
| Detection Method | Chromogenic & Redox-Based Colorimetric Assay |
| Instrument Type | Fully Automated |
| Detection Targets | Total Bacterial Count, *Salmonella* spp., Total Coliforms, *Staphylococcus aureus*, *Escherichia coli*, *Listeria monocytogenes* |
| Sample Types | Compound Feeds (layer/broiler chicken, swine, duck), Animal-Origin Feeds (blood meal, meat-and-bone meal, fish meal, feather meal, whey powder), Plant-Origin Feeds (corn, bran, soybean meal, peanut meal, cottonseed meal) |
| Detection Throughput | 8 independent channels |
| Dimensions | 31.2 cm (L) × 17.5 cm (W) × 9.5 cm (H) |
| Regulatory Compliance | ISO 16140:2003 validated, ISO/IEC 17025:2005 aligned, T/SDAA 025–2021 certified |
| Brand | MBS.SRL |
|---|---|
| Country of Origin | Italy |
| Model | MBS(Fitlylab) |
| Detection Method | Chromogenic Enzyme-Substrate Assay Coupled with Redox-Based Colorimetric Monitoring |
| Target Microorganisms | Escherichia coli, Staphylococcus aureus, Salmonella spp., Pseudomonas aeruginosa, Listeria monocytogenes, Enterococcus faecalis, Total Viable Count, Coliforms, E. coli (specific), Fecal Coliforms, Enterobacteriaceae, Yeasts |
| Sample Types | Solid, Liquid, Surface Swabs, Paste, Slurry |
| Detection Speed | 2–10× faster than conventional culture-based methods |
| Throughput | 8 independent, temperature-controlled detection channels |
| Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% |
| Compliance | ISO 16140:2003 (Microbiology of Food and Animal Feeding Stuffs — Validation of Alternative Methods), ISO/IEC 17025:2005 (General Requirements for the Competence of Testing and Calibration Laboratories) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L02 |
| Price Range | USD 14,000 – 70,000 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal Oxidative-Reductive Kinetic Assay with Tri-wavelength Photometric Monitoring |
| Sample Throughput | 8 Independent Channels |
| Detection Limit | 1 CFU per test |
| Specificity | ≥99.999% |
| Sample Types | Liquid, Solid, Surface Swab, Paste, Aerosol Condensate |
| Regulatory Compliance | Validated for Food, Water, Environmental & Clinical Surveillance per ISO, EN and FDA-aligned protocols |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L22 |
| Certification | ISO 16140:2003 (Alternative Method Validation), ISO/IEC 17025:2005 (Internal Accreditation) |
| Detection Principle | Multi-modal optical biosensing based on real-time redox-mediated chromogenic kinetics |
| Sample Throughput | 8 independent, temperature-controlled channels |
| Detection Sensitivity | ≥1 CFU per test |
| Specificity | >99.999% for target analytes |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., dairy, paste, slurry) |
| Readout Method | Simultaneous tri-wavelength photometric monitoring (450 nm, 530 nm, 630 nm) |
| Report Output | PDF with audit trail, timestamped raw kinetic curves, and quantitative CFU/mL or CFU/g results |
| Software | Fitlylab v5.x (Windows-based, multilingual, GLP-compliant data management) |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fitlylab-L04 |
| Price Range | USD 13,500 – 68,000 |
| Brand | MBS.SRL |
|---|---|
| Origin | Italy |
| Model | Fitlylab-L06 |
| Certification | ISO 16140:2003 (Microbiology of Food and Animal Feeding Stuffs – Validation of Alternative Methods) |
| ISO/IEC 17025 | 2005 (General Requirements for the Competence of Testing and Calibration Laboratories) |
| Detection Principle | Multi-modal optical biosensing based on real-time redox-mediated chromogenic kinetics |
| Sample Throughput | 8 independent, temperature-controlled channels |
| Detection Sensitivity | ≥1 CFU per assay |
| Specificity | ≥99.999% for *Salmonella* spp. |
| Sample Types | Liquid, solid, surface swab, aerosol (via impinger collection), semi-solid (e.g., milk, paste, homogenates) |
| Detection Time | 4–12 h (vs. 48–96 h for conventional culture) |
| Wavelengths | Simultaneous triple-wavelength photometric detection (450 nm, 540 nm, 630 nm) |
| Data Output | Automated PDF report with timestamped kinetic curves, CFU/mL or CFU/g quantification, pass/fail flagging against user-defined thresholds |
| Software | Fitlylab v3.x (Windows-based, multilingual, audit-trail enabled) |
| Brand | NAI Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NAI-STV6 |
| Price | Upon Request |
| Construction Material | AISI 304 Stainless Steel |
| Filter Cup Configuration | 6 × Reusable 3B-Type Cups |
| Included Components | 6 × Filter Cups, 6 × 500 mL Borosilicate Glass Filtration Bottles, 6 × Sterile Bent Tubing Assemblies |
| Filter Membrane Compatibility | 0.45 µm or 0.22 µm, Ø50 mm |
| Max Vacuum Level | −0.08 MPa (−0.8 bar) |
| Air Flow Rate | ≥50 L/min at Rated Vacuum |
| Sterilization | Autoclavable (121 °C, 20–30 min, full manifold assembly) |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SEN580 |
| Pricing | Available Upon Request |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MD500 / MD500e Offline |
| Instrument Type | Fully Automated |
| Detection Scope | Relatively Pure Aqueous Samples in All Microbial Control Scenarios |
| Measurement Range | 0–10,000 AFU/mL |
| Detection Limit | 1 AFU (Auto-Fluorescence Unit) |
| Analysis Mode | Continuous Operation |
| Flow Rate | 3–15 mL/min |
| Channel Capacity | 1–10 Built-in Channels (Expandable to 100) |
| Inlet/Outlet Connection | 1/8″ OD (3.2 mm) |
| Dimensions | 38 cm × 44 cm × 31 cm |
| Minimum Detectable Particle Size | 0.5 µm |
| Response Time | 2 seconds |
| Sample Temperature Range | 5–99 °C |
| Operating Environment | 0–50 °C / ≤80% RH |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Weight | 15 kg |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MD500 / MD500e Online |
| Instrument Type | Fully Automated |
| Detection Target | Microorganisms and Inert Particles in Water |
| Sample Type | Relatively Pure Aqueous Streams in Microbial Control Environments |
| Detection Speed | Real-Time Continuous Monitoring |
| Measurement Range | 0–10,000 AFU/mL |
| Detection Limit | 1 AFU (Autofluorescence Unit) |
| Flow Rate | 3–15 mL/min |
| Inlet/Outlet Connection | 1/8″ OD (3.2 mm) |
| Analysis Mode | Continuous Operation |
| Dimensions (W×D×H) | 50 cm × 32 cm × 60 cm |
| Minimum Detectable Size | 0.5 µm |
| Response Time | 2 s |
| Sample Temperature Range | 5–99 °C |
| Ambient Operating Conditions | 0–50 °C / ≤80% RH |
| Power Supply | 100–240 VAC, 50/60 Hz, 5 A |
| Weight | 35 kg |
| Data Communication | 4–20 mA Analog Output (Standard), Configurable Range |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-08W |
| Price | USD 765 (based on ¥5500 at 1 USD ≈ ¥7.2) |
| Capacity | 3–400 mL |
| Timer Range | 1 s to 100 min (or continuous mode) |
| Pulsing Frequency | 3–12 strokes/sec |
| Adjustable Stroke Gap | 0–50 mm |
| Dimensions (W×D×H) | 420 × 230 × 330 mm |
| Net Weight | 19 kg |
| Operating Temperature | 0–35 °C |
| Power Supply | 220 V AC / 50 Hz, 200 W |
| Sterile Stomacher Bag Size | 17 × 30 cm |
| Display | 4.3-inch capacitive touch screen |
| Audio Alarm | Yes |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TY-YXL |
| Detection Principle | Photometric Colorimetry (Based on GB/T 5750.11–2023) |
| Measurement Range | 0.5–300 mg/L (low range) and 0.1–60% (high range), segmented |
| Accuracy | ≤10% error |
| Repeatability | <0.5% RSD |
| Stability | <0.5% drift over 30 min |
| Wavelength Selection | Automatic |
| Light Source | Imported Cold LED (100,000 h lifetime) |
| Display | 3.5″ Color LCD |
| Operating Environment | 0–50 °C, 0–90% RH |
| Data Storage | >80,000 records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth |
| Power | 5 V DC / 5600 mAh Li-ion battery (8 h continuous operation) |
| Dimensions | 190 × 77 × 72 mm |
| Weight | 325 g |