| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(YE)-300008 |
| Price | Upon Request |
| Maximum Load Capacity | 3000 kN |
| Accuracy Class | Class 1 (per GB/T 3159 & ISO 7500-1) |
| Force Measurement Range | 300–3000 kN |
| Indicated Relative Error | ±1% |
| Loading Rate Adjustment | 1–15 mm/s (manually controlled via hydraulic flow valve) |
| Internal Clear Span | 450 mm |
| Upper Platen Dimensions | 280 × 280 mm |
| Lower Platen Dimensions | 280 × 280 mm |
| Piston Stroke | 80 mm |
| Motor Power | 0.75 kW |
| Net Weight | ~1000 kg |
| Overall Dimensions (W×D×H) | 950 × 560 × 1570 mm |
| Standard Fixture | One set of compression platens with alignment guides |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(YE)-300008RTYY |
| Quotation | Upon Request |
| Maximum Load Capacity | 3000 kN |
| Accuracy Class | Class 1 |
| Force Measurement Range | 120–3000 kN |
| Relative Indicated Error | ±1% |
| Loading Speed | 1–15 mm/s (adjustable) |
| Clear Distance Between Columns | 320 mm |
| Upper Platen Dimensions | 320 × 220 mm |
| Lower Platen Dimensions | 400 × 400 mm |
| Piston Stroke | 80 mm |
| Motor Power | 2.2 kW |
| Net Weight | ~1500 kg |
| Overall Dimensions (W×D×H) | 700 × 550 × 1800 mm |
| Compliance Standards | GB/T 228–2002, GB/T 5224–1995, GB/T 232–1999 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | N/A |
| Pricing | Upon Request |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | HGS-W21 (Wireless Indoor Temp/RH Logger), HGS-R5 (433 MHz Wireless Data Concentrator) |
| Communication | 433 MHz ISM-band RF (licensed by China NRR) |
| Storage | Onboard non-volatile memory (≥32,000 records per unit) |
| Alarm | Configurable high/low thresholds with local buzzer |
| Compliance | Designed to support GSP (China Good Supply Practice), GLP (Good Laboratory Practice), and archival environmental control per DA-001–2021 (National Archives Administration of China) |
| Connectivity | Up to 250 wireless sensors per concentrator (HGS-R5) |
| Software | Windows-compatible (Win7–11), real-time graphing, statistical reporting (min/max/avg), audit trail export (CSV/PDF), alarm log with timestamp and event annotation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 482 |
| Quotation | Available upon Request |
| Torque Range | 2.83 N·m to 1130 N·m |
| Analog Output | ±5 V DC or ±10 V DC (user-selectable) |
| Digital Interface | RS232C |
| Combined Accuracy (nonlinearity + hysteresis + nonrepeatability) | ±0.2% FS (Code N) / ±0.15% FS (Code C) |
| Rotational Effect on Zero | ±0.05% FS (Code N) / ±0.025% FS (Code C) |
| Thermal Zero Drift | ±0.007% FS/°F (Code N) / ±0.003% FS/°F (Code C) |
| Thermal Span Drift | ±0.007% reading/°F (Code N) / ±0.003% reading/°F (Code C) |
| Temperature Compensation Range | +75 to +150 °F |
| Operating Temperature Range | +32 to +175 °F |
| Nominal Overrange Capacity | 30% FS |
| Bessel Filter Cutoff Frequencies | 0.1–200 Hz (11 steps: 1–2–5 sequence) |
| System Resolution | 0.02% FS (±10 V) / 0.04% FS (±5 V) |
| Supply Voltage | 10–15 V DC @ 200 mA nominal |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 590 |
| Pricing | Available Upon Request |
| Measurement Range | 4.52 N·m to 83,000 N·m |
| Output Signals | ±5 V DC, 4–20 mA, mV/V |
| Frequency Response | 0–500 Hz |
| Power Supply | 10.5–24 V DC (nominal 12 V DC battery compatible) |
| Accuracy (combined nonlinearity/hysteresis/nonrepeatability) | ≤±0.10 % FS |
| Thermal Zero Drift | ≤±0.0025 % FS/°F |
| Thermal Span Drift | ≤±0.0025 % RDG/°F |
| Compensated Temperature Range | +75 to +175 °F |
| Operating Temperature Range | −25 to +185 °F |
| Storage Temperature Range | −65 to +225 °F |
| Overrange Capability | ±33 % FS |
| Bandwidth Options | DC–500 Hz (high-frequency mode), DC–1 Hz (low-frequency mode) |
| Intrinsic Safety Certification | Compliant with IEC 60079-11 (Ed. 5.0) and UL 913 Class I, Div 1, Groups A, B, C, D |
| Brand | Hprobe |
|---|---|
| Origin | France |
| Model | IBEX-300 |
| Wafer Compatibility | 100–300 mm |
| Max In-Plane (XY) Field | 350 mT |
| Max Perpendicular (Z) Field | 550 mT |
| Field Uniformity (±1 mm) | ±1% |
| Field Resolution (XY/Z) | 0.05 / 0.02 mT |
| Angular Resolution | 0.02° |
| Field Sweep Sampling Rate | < 50 kHz |
| R-H Loop Acquisition Time | < 100 ms |
| Z-Gap Adjustment Range | 500 µm – 5 mm |
| Integrated Instrumentation | Dual-Channel 40 MHz AWG, Sub-200 ps Pulse Generator, SMU (20 mV / 1 nA min ranges), 18-bit DMM (10 nV resolution), Switch Matrix & DAQ Support |
| Software Modes | Calibration / Engineering / Production |
| Compliance | Designed for ASTM F3092, ISO/IEC 17025-aligned test workflows, supports GLP/GMP audit trails via optional 21 CFR Part 11-compliant software module |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HK-3100MD |
| Price Range | USD 1,400 – 7,000 |
| Application Field | Petroleum & Liquid Hydrocarbon Density Testing |
| Instrument Type | Buoyancy-Based Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid Only |
| Density Measurement Range | 0–2 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Temperature Control Range | Ambient to 100 °C (user-selectable, ±0.2 °C stability) |
| Minimum Sample Volume | 50 mL |
| Dual-Bath Capacity | 2 independent test positions |
| Stirring Speed | 1250 rpm |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Heating Power | Main Heater 800 W + Auxiliary Heater 300 W |
| Dimensions (L×W×H) | 500 × 305 × 550 mm |
| Weight | 25 kg |
| Interface Options | RJ45 Ethernet, USB 2.0 |
| Compliance | GB/T 1884–2000 |
| Brand | HUAXI INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | XD50 |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0003 g/cm³ |
| Repeatability | ±0.0002 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Temperature Control Range | 5–65 °C |
| Display | 7-inch Full-Color Touchscreen |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MD-2 / MD-4 / MD-5 |
| Price Range | USD 700–1,400 (FOB) |
| Application Scope | General-purpose solid density measurement |
| Instrument Type | Buoyancy-based density analyzer |
| Form Factor | Benchtop laboratory instrument |
| Sample Type | Non-porous solids (glass, ceramics, sintered materials) |
| Density Range | 1.1–3.3 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.01 °C |
| Horizontal Bath Uniformity | ±0.01 °C |
| Vertical Bath Uniformity | ±0.03 °C |
| Heating Rate | ≥0.1 °C/min (±0.02 °C/min) |
| Magnetic Stirring | Stepless speed control, 1–1000 rpm |
| Power Supply | 220 V AC, 1000 W |
| Compliance Standard | GB/T 14901–1994 (Glass — Determination of Density by Sink-Float Method) |
| Minimum Sample Mass | 1 g |
| Brand | ADVANTEC |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | T5 Plus |
| Instrument Type | Portable Densitometer |
| Measurement Mode | Transmission (Black-and-White) |
| Sample Type | Solid and Liquid (Transparent/Translucent) |
| Density Range | 0–2.000 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Aperture Options | φ1 mm, φ2 mm, φ3 mm |
| Power Supply | AC Adapter (9 V DC, 500 mA) |
| Compliance | ISO 5-3, ISO 5-4, ASTM E308, JIS Z 8722 |
| Software Interface | RS-232C (cable sold separately) |
| Calibration Standards | NIST-traceable calibration film included |
| Operating Temperature | 15–35 °C |
| Relative Humidity | ≤80 % RH (non-condensing) |
| Brand | Innovatest |
|---|---|
| Country of Origin | Netherlands |
| Manufacturer | Innovatest B.V. |
| Type | Rockwell Hardness Tester |
| Measurement Range | 10–100 HR |
| Total Test Force | 187.5 kgf |
| Test Space | 650 mm (H) × 175 mm (D) |
| Nose Extension Length | 170 mm |
| Test Table Dimensions | 425 mm × 370 mm (with hardened zone & T-slots) |
| Preload Forces | 3 kgf, 10 kgf |
| Main Load Range | 15–150 kgf |
| Loading System | Fully Automatic, Load Cell-Based Closed-Loop Control |
| Guidance System | Full-Height Linear Rails + Precision Ball-Screw Drive |
| Display | 6.5″ Industrial Touchscreen |
| Software | I-TOUCH™ Hardness Control Suite |
| Data Storage | Internal Memory (up to 150 readings) |
| Interface | USB |
| Illumination | Integrated LED Surface Lighting |
| Base Enclosure | Interchangeable ABS Protective Housing |
| Brand | INNOVATEST |
|---|---|
| Origin | Netherlands |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | NEXUS 3001XLM-IMP |
| Test Force Range | 30 kgf to 3000 kgf |
| Z-Axis Travel | 345 mm |
| Specimen Height Clearance | 335 mm |
| Depth Clearance | 220 mm |
| Turret | 2-position (indenter + Brinell objective with annular LED illumination) |
| Imaging System | 5 MP full-HD camera with motorized zoom and auto-focus |
| Control Interface | IMPRESSIONS™ software on 15″ industrial touchscreen |
| Measurement Method | Automated video-based indent diameter analysis per ISO 6506-1 and ASTM E10 |
| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 3621 |
| Pricing | Upon Request |
| Brand | Instron |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 8800 MT |
| Pricing | Available Upon Request |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | AutoX750 |
| Pricing | Upon Request |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Model | AVE2 |
| Input Interface | ±10 V analog compatible |
| Sampling Rate | 490 Hz |
| Compliance | ISO 527, ASTM D638, ASTM D3039 |
| Environmental Operation | Ambient, elevated/low temperature chambers, liquid baths |
| Output Compatibility | DIC-ready image sequences (AVI, TIFF stack) |
| Mounting | Universal optical rail + adjustable tripod base |
| Software Integration | Bluehill® 3 (native), third-party DIC platforms (e.g., VIC-2D, GOM Correlate) |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | BLUEHILL® UNIVERSAL |
| Pricing | Upon Request |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer | Instron Corporation |
| Product Type | Imported |
| Model | DIC Replay |
| Pricing | Upon Request |
| Brand | INTEC |
|---|---|
| Origin | Japan |
| Model | KE-6 / KE-6S / KE-6SS |
| Detection Method | Transmission optical imaging of aligned filaments |
| Max Single-Measurement Capacity | 100 (KE-6), 200 (KE-6S & KE-6SS) filaments |
| Segment Measurement Range | 1–6 segments |
| Total Measurable Filaments per Sample | up to 599 (KE-6), 999 (KE-6S & KE-6SS) |
| Filament Linear Density Range | 0.6–33 dtex (KE-6/KE-6S), 2–33 dtex (KE-6SS, TiO₂ ≤2.0% w/w) |
| Filament Count Adjustment Limit | Total dtex × filament count ≤ 50,000 (KE-6), ≤ 250,000 (KE-6S/KE-6SS) |
| Alignment Aid | Vibration bar for uniform filament arrangement |
| Image Acquisition | Real-time CCD-based transmission imaging with auto-focus assist |
| Illumination Monitoring | Integrated lux meter for ambient and backlight intensity control |
| Operation Mode | Manual (button) or foot-switch triggered scanning |
| Power Supply | 100 V / 220 V, 50/60 Hz, single-phase |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | IR-2 |
| Pricing | Available Upon Request |
| Measurement Bands | 3–5 µm, 8–14 µm, 1–22 µm |
| Emissivity Range | 0.100–0.990 |
| NEΔε (Noise-Equivalent Emissivity Change) | 0.001 |
| Accuracy | ±0.02 (for ε > 0.50) |
| Repeatability | ±0.01 |
| Sample Temp. Range | Ambient to 300 °C (optional heated stage) |
| Max. Sample Diameter | 50 mm |
| Measurement Time | < 3 s after trigger |
| Display Resolution | 0.001 (LED) |
| Power Supply | AC 220 V, 50 Hz |
| Interface | RS-232 serial port |
| Optical Method | Normal-incidence reflectance-based emissivity derivation using calibrated blackbody source |
| Brand | Irian |
|---|---|
| Origin | France |
| Model | J2 |
| Pressure Range | 0–14,500 psi |
| Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.3 °C |
| Pressure Uncertainty | ±1.5 psi |
| Cell Volume | 1.24 mL |
| Optical Imaging | Integrated HD Digital Camera |
| Actuation | Embedded Electromechanical Piston Pump with Automatic Valving |
| Gas Flow Control | Micro-Flow Regulating Valve |
| Cell Tilt | 0–45° |
| Dimensions | 610 mm × 559 mm × 203 mm (L×W×H) |
| Cooling | High-Capacity Forced-Air System |
| Agitation | Electromagnetic Vibration Module |
| Brand | ITACA |
|---|---|
| Origin | Spain |
| Model(s) | DKV1, DKV8, PDMK |
| Frequency Range | 1.5–2.6 GHz (nominal, subject to MUT performance) |
| Permittivity (ε′) | < 100 |
| Loss Factor (ε′′) | 0.001–10 |
| Loss Tangent (tan δ) | < 0.1 |
| Measurement Accuracy | ±1–2% for ε′, ±2–5% for ε′′ (range-dependent) |
| RF Power Output | 0 dBm |
| Interface | USB |
| OS Compatibility | Windows 7/8/10 |
| Sample Types | Solid, Liquid, Powder |
| Compliance | Designed for ASTM D2520, ISO 18563-1, and IEC 60250–compliant workflows |
| Brand | J.U.M. |
|---|---|
| Origin | Germany |
| Model | AeroFid60 Aerosol Can Gas Leak Detection System |
| Category | Physical Property Testing Instruments — Other Physical Property Testing Instruments |
| Import Status | Imported |
| Origin | Japan |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | MOKE-1000 Series |
| Pricing | Upon Request |
| Measurement Modes | Polar MOKE, Longitudinal MOKE, Faraday Rotation, Perpendicular Magnetic Anisotropy (PMA) Analysis |
| Light Source | Collimated Diode Laser (635 nm or 785 nm), Optional Hg Lamp for domain imaging |
| Probe Spot Size | 2–5 µm (micro-MOKE), 1 mm (macro-MOKE), 2 mm (Faraday) |
| Spatial Resolution (Domain Imaging) | ≤1 µm (with 50× objective) |
| Maximum Applied Field | ±10 kOe (1 T) standard |
| Field Orientation | In-plane (±10°–100° continuous rotation) and out-of-plane |
| Cryogenic Option | Compatible with variable-temperature cryostats (4 K–300 K) |
| Compliance | ASTM F1529, ISO/IEC 17025-aligned calibration traceability, GLP-compliant data logging |
| Key | Brand: JB Instruments |
|---|---|
| Model | JB-150-BK-S |
| Origin | Shanghai, China |
| Drive Medium | Compressed Air (3–6.9 bar) |
| Test Medium | Municipal Tap Water |
| Max Test Pressure | 0–1500 bar (150 MPa) |
| Pressure Control Accuracy | ±10 bar (hold), ±0.5% FS (sensor) |
| Pressure Ramp Rate | 100–6000 bar/min (adjustable) |
| Power Supply | 220 V, 50 Hz, 0.15 kW |
| High-Pressure Outlet | 1 × G1/4 internal thread (600 series) |
| Cabinet Dimensions | 800 × 700 × 1500 mm |
| Test Chamber Dimensions | 2000 × 900 × 1200 mm (304 stainless steel, dual-zone with integrated water recovery tank) |
| Safety Features | Blast-resistant tempered glass lid, automatic pressure relief, real-time curve logging, audit-ready data export |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | JB |
| Pricing | Available Upon Request |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-150-BK-S |
| Max Test Pressure | 0–1500 bar (150 MPa) |
| Test Medium | Municipal Tap Water |
| Drive Air Pressure | 3–6.9 bar |
| Air Flow Rate | 2 m³/min |
| Pressure Control Accuracy | ±10 bar (hold), ±0.5% FS (sensor) |
| Pressure Ramp Rate | 100–6000 bar/min (adjustable) |
| Power Supply | 220 V, 50 Hz, 0.15 kW |
| Control Interface | Integrated Touchscreen PC with A4 Report Export |
| Dimensions (Control Cabinet) | 800 × 700 × 1500 mm |
| Dimensions (Test Chamber) | 2000 × 900 × 1200 mm |
| Construction | 304 Stainless Steel Chamber + Dual-Pump Air-Driven Hydraulic System |
| Safety Features | Explosion-Resistant Tempered Glass Lid, Automatic Depressurization, Dual-Stage Filtration |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-201E |
| Price | Upon Request |
| Measurement Principle | UV-Vis Spectrophotometry (Acetylacetone Colorimetric Method) |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Photometric Range | Transmittance 0–100%, Absorbance 0–2.0 A |
| Formaldehyde Quantification Range | 5.00–500.00 mg/kg |
| Photometric Accuracy | ±2% FS |
| Light Source | Imported Long-Life Tungsten-Halogen Lamp |
| Optical System | Self-Aligning Optical Path with 1200 lines/mm Diffraction Grating Monochromator |
| Power Supply | AC 220 V ±10%, 50 Hz, 50 W |
| Dimensions (W×D×H) | 400 × 300 × 200 mm |
| Weight | 10 kg |
| Brand | JByq |
|---|---|
| Origin | Shanghai, China |
| Model | JB-300A |
| Instrument Type | Benchtop True Density Analyzer |
| Application Scope | Universal for Solids & Liquids |
| Density Range | 0.0001–99.9999 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Weighing Capacity | 0.001–200 g |
| Measurement Time | ~5 s |
| Water Tank Dimensions (Std) | 169 mm × 98 mm × 83 mm |
| Temperature Compensation | Real-time water temperature input |
| Interface | RS-232C |
| Compliance | ASTM D792, ASTM D297, ISO 1183, ISO 2781, GB/T 1033, GB/T 2951, JIS K6268, DIN 53516 |