| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-400H |
| Compliance | GB/T 3682.1–2018, ASTM D1238, ISO 1133–1 |
| Temperature Control Range | 100–400 °C (±0.2 °C) |
| Load Options | 0.325 kg, 1.2 kg, 2.16 kg, 5.0 kg, 10.0 kg, 21.6 kg |
| Piston Travel Detection | High-resolution optical encoder (0.01 mm resolution) |
| Extrudate Cutting | Automatic timed or manual mode |
| Sample Preheating Time | Programmable (0–999 s) |
| Data Output | USB and RS232 interfaces |
| Display | 7-inch TFT touchscreen with real-time melt flow curve visualization |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-400H |
| Compliance | GB/T 3682.1–2018, ISO 1133–1:2011, ASTM D1238 |
| Temperature Control Range | Ambient to 400 °C (±0.2 °C stability) |
| Load Options | 0.325–21.6 kg (standard weights per ISO/ASTM) |
| Extrudate Cutting | Automatic timer-based or manual |
| Piston Travel Resolution | 0.01 mm |
| Data Output | MFR (g/10 min), MVR (cm³/10 min), flow rate curve |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-A |
| Frequency Range | 10 kHz – 70 MHz |
| Main Capacitance Tuning Range | 30–500 pF |
| Capacitance Resolution | ±0.2 pF |
| Q Factor Range | 1–1000 (auto/manual range switching) |
| Q Measurement Accuracy | <5% |
| Q Resolution | 0.1 (4-digit display) |
| Capacitance Measurement Range | 1–460 pF |
| Loss Tangent (tan δ) Determination Method | Resonant Q-shift comparison using dual-variable capacitor system |
| Dielectric Constant (εᵣ) Calculation | Based on parallel-plate capacitance ratio with/without sample |
| Brand | JB-Bin |
|---|---|
| Origin | Shanghai, China |
| Model | JM8 |
| Test Medium | Oil, Water, or Ethylene Glycol Mixture |
| Max Pulse Pressure | 0–70 MPa (adjustable, optional higher range) |
| Pressure Control Accuracy | ±0.01 bar |
| Pulse Frequency | 0–2 Hz (dependent on specimen volume and compliance) |
| Waveform Options | Square, T-wave, Triangular, Sine |
| Test Temperature Range | –40 °C to +150 °C (±3 °C) |
| Cycle Capacity | ≥100,000 cycles per continuous test run |
| Continuous Operation Duration | ≥720 hours (30 days) |
| Specimen Capacity | 2–8 units (configurable per system setup) |
| Mounting Angles | 90° or 180° per ISO 6803 / SAE J1401 / GB/T 14904 compliance |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-JM8 |
| Test Pressure Range | 0–100 MPa (customizable) |
| Pulse Frequency | 0–2 Hz (customizable) |
| Test Media | Water, Brake Fluid, Hydraulic Oil |
| Media Temperature Range | −40 °C to +150 °C (customizable) |
| Cycle Count Capacity | >10⁷ cycles (user-definable) |
| Channel Configuration | 1 channel (expandable) |
| Waveform Options | Square, T-shaped, Triangular, Sine |
| Control Architecture | Dual-level PC-based electro-hydraulic servo control with independent modular controllers |
| Pressure Regulation Method | Accumulator-assisted passive pressure maintenance |
| Safety Features | Overpressure cutoff, overload protection, automatic depressurization upon rupture, auto-degassing at startup, post-test fluid containment |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-JM8 |
| Type | Dual-Pulse Hydraulic Fatigue Testing System |
| Origin | Shanghai, China |
| Application | Pressure cycling fatigue testing of pressurized components |
| Control | Computer-controlled servo/proportional hydraulic system |
| Max. Test Cycles | ≥1,000,000 cycles (continuous) |
| Test Medium | Hydraulic oil or ethylene glycol–water mixture |
| Pressure Range | 0–5 MPa (adjustable) |
| Pressure Control Accuracy | ±0.01 MPa (full-scale dependent) |
| Pulse Frequency | 5–120 cycles/min (programmable) |
| Pulse Waveform | Square or trapezoidal (pulse width configurable per user specification) |
| Fluid Temperature Range | Ambient to 160 °C (user-defined setpoint) |
| Environmental Chamber Temp. Range | –30 °C to +250 °C (optional integrated thermal enclosure) |
| Data Acquisition | Real-time pressure vs. time curve logging, USB export, automated report generation |
| Compliance Support | Designed to support ASTM D3078, ISO 6803, SAE J1402, GB/T 10544, and internal OEM validation protocols |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-JM8 |
| Type | Hydraulic Pressure Test System |
| Max Test Pressure | 0–400 MPa |
| Pressure Control Accuracy | ±1% F.S. |
| Measurement Accuracy | ±0.075% F.S. |
| Timing Range | 0–999 h |
| Test Media | Water, Hydraulic Oil, or Custom Fluids |
| Media Temperature Range | Ambient to 150 °C ±3 °C |
| Drive Air Supply | 3–8 bar |
| Power Supply | AC 220 V |
| Control Options | Manual / PLC / Computer-Controlled (SCADA-Compatible) |
| Test Stations | Single or Multi-Station (Customizable) |
| Sealing Architecture | Non-Welded, Modular Tubing Connections |
| Safety Response | Automatic Pressure Dump & Pump Shutdown upon Burst Detection |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-JM8 |
| Test Medium | Hydraulic Oil or Ethylene Glycol Mixture |
| Max Test Pressure | 0–5 MPa (adjustable) |
| Pressure Control Accuracy | ±0.01 MPa (full scale dependent) |
| Pulse Frequency | 5–120 cycles/min (adjustable) |
| Pulse Waveform | Square or Trapezoidal (pulse width configurable per user requirement) |
| Test Medium Temperature Range | Ambient to 160 °C |
| Environmental Temperature Range | –30 °C to 250 °C (adjustable) |
| Maximum Continuous Cycles | ≥1,000,000 |
| Control Method | PC-based Automated Control with Servo/Proportional Actuation |
| Data Interface | USB for data export and report printing |
| Compliance | Designed for ISO 6803, ISO 7241-2, SAE J1401, ASTM D3078, and GB/T 5563 testing protocols |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Bulk Density Tester |
| Design | Portable Benchtop Unit |
| Sample Form | Dry Powders & Granules |
| Standard Compliance | GB/T 16913–2008, ASTM D1473, ISO 3953 |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Cylinder Volume | 100 mL |
| Funnel Angle | 60° |
| Cylinder & Funnel Material | AISI 304 Stainless Steel |
| Scraper Blade Width | 25 mm |
| Overall Dimensions | ~160 × 160 × 300 mm |
| Net Weight | 3.7 kg |
| Required External Balance | Capacity ≥1000 g, Readability ≤0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Type | Bulk Density Tester |
| Design | Portable |
| Sample Form | Dry Solid Powders & Granules |
| Standard Compliance | GB/T 16913–2008 (Natural Pile Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Material | AISI 304 Stainless Steel |
| Scraper & Plug Rod | AISI 304 Stainless Steel, 25 mm Width |
| Dimensions | ≈ 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required Balance | 1 kg capacity, 0.02 g readability |
| Brand | Jingxin (Chengdu) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | A302-2 |
| Instrument Type | Bulk Density Tester |
| Instrument Class | Portable |
| Sample Form | Solid Powders & Granules |
| Application Scope | General-purpose bulk density measurement of free-flowing powders |
| Standard Compliance | GB/T 16913–2008 (Natural Pile Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Material | Stainless Steel 304 |
| Scraper Blade | Stainless Steel, 25 mm wide |
| Plug Rod | Stainless Steel 304 |
| Overall Dimensions | ≈ 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Jingxin (Chengdu) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-A303 |
| Instrument Type | Hall Flowmeter & Apparent Density Tester |
| Form Factor | Benchtop (Non-Portable) |
| Sample Type | Free-Flowing Solid Powders |
| Primary Applications | Metal Powders, Additive Manufacturing Feedstocks, Battery Cathode/Anode Materials, Ceramic Precursors, and Industrial Powder QC |
| Standards Compliance | GB/T 1482–2010 (Hall Flow), GB/T 1479.1–2011 (Apparent Density), ASTM B213 (Standard Test Methods for Flow Rate of Metal Powders), ISO 4490:2018 (Metallic powders — Determination of flow rate) |
| Key Dimensions | 230 × 170 × 300 mm (W × D × H) |
| Net Weight | 3.7 kg |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm (interchangeable) |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel 304, 25 mm width |
| Stopper Rod | Stainless steel 304 |
| Timing Resolution | 0.01 s (external stopwatch required) |
| Recommended Balance | 1000 g capacity, 0.02 g readability (user-supplied) |
| Brand | Jingxin (Chengdu) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-A303 |
| Instrument Type | Bulk Density & Flow Tester |
| Design | Benchtop (Non-Portable) |
| Measurement Principle | Standard Funnel Flow Method (Hall Flowmeter) & Gravimetric Bulk Density Determination |
| Applicable Standards | GB/T 1482–2010, GB/T 1479.1–2011 |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Cone Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel 304, 25 mm wide |
| Stopper Rod | Stainless steel 304 |
| Dimensions | 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Required Ancillary Equipment | Analytical balance (max 1000 g, readability 0.02 g) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-10 Series |
| Instrument Type | Tap Density Tester |
| Density Measurement Range | 0–10 g/cm³ |
| Sample Form | Powders & Granules |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tap Count Range | 1–9999 adjustable |
| Repeatability | ≤ ±1% |
| Operating Voltage | AC 220 V |
| Power Consumption | 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Test Capacity | ≤500 g per cylinder |
| Cylinder Compatibility | Removable borosilicate glass cylinders (25 mL and 100 mL) |
| Software Output Formats | Word, PDF, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JZ-10C |
| Instrument Type | Tap Density Tester |
| Instrument Class | Benchtop (Not Portable — corrected per technical specification: fixed installation, 15 kg, 455×280×125 mm) |
| Sample Form | Powders & Granules |
| Measurement Principle | Mechanical Tapping (Rotational + Vertical Oscillation) |
| Density Range | 0–10 g/cm³ |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Tapping Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tapping Count Range | 1–9999 cycles (user-defined) |
| Sample Vessels | Three removable 25 mL and three 100 mL borosilicate glass cylinders |
| Data Output Formats | PDF, Word, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993, USP <616> |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Brand | Jiubin |
|---|---|
| Model | JB |
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Pricing | Available Upon Request |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-150-BK |
| Test Medium | Municipal tap water or customer-specified fluid |
| Max Test Pressure | 0–1500 bar (150 MPa) |
| Drive Air Pressure | 6.9 bar |
| Pressure Ramp Rate | 100–6000 bar/min (adjustable) |
| Pressure Measurement Accuracy | ±0.5% FS (high-precision strain-gauge transducer) |
| Power Supply | 220 V, 50 Hz, 0.15 kW |
| Drive Method | Pneumatically actuated dual-pump system (low- and high-pressure stages) |
| Air Supply Requirement | 3–6.9 bar, ≥2 m³/min |
| High-Pressure Outlet | 1 × G1/4" internal thread (600 psi rated) |
| Control Cabinet Dimensions | 800 × 700 × 1500 mm |
| Test Chamber Dimensions | 2000 × 900 × 1200 mm (2 mm steel + energy-absorbing buffer layer) |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-150-BK-S |
| Quotation | Upon Request |
| Test Medium | Municipal Tap Water |
| Max Test Pressure | 0–1500 bar (150 MPa) |
| Drive Air Pressure | 6.9 bar |
| Pressure Ramp Rate | 100–6000 bar/min (adjustable) |
| Pressure Measurement Accuracy | Class 0.5 (high-precision transducer) |
| Power Supply | 220 V, 50 Hz, 0.15 kW |
| Drive Method | Pneumatically Actuated Dual-Pump System |
| Air Supply Requirement | 3–6.9 bar, 2 m³/min |
| High-Pressure Outlet | 1 × G1/4″ internal thread (600 series) |
| Control Cabinet Dimensions | 800 × 700 × 1500 mm |
| Test Chamber Dimensions | 2000 × 900 × 1200 mm (304 stainless steel, with integrated water recovery sump and stainless mesh tray) |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-400H |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-600-5 |
| Sinusoidal Force Range | 9800–49000 N |
| Rated Frequency Range | 5–3000 Hz |
| Peak Velocity | 1020 m/s |
| Zero-Load Acceleration | 1.5 m/s² |
| Peak-to-Peak Displacement | 51 mm |
| Payload Capacity | 140–1000 kg |
| Power Consumption | 22–76 kVA |
| Supply Voltage | AC 380 V ±10%, 50 Hz |
| Moving Coil Mass | 3–50 kg |
| Power Amplifier Weight | 250–800 kg |
| Cooling Method | Forced Air |
| Compliance | GB/T 13310-91, Q/320502SN001-2003 |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-B |
| Pricing | Available Upon Request |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-C5 |
| Wind Pressure Range | –8000 to +8000 Pa (for wind load resistance) |
| Air Flow Rate | 0–540 m³/h |
| Water Spray Rate | 2–3 L/m²·min |
| Displacement Measurement Range | 0–50 mm |
| Specimen Size Capacity | 0.8 × 0.8 m to 3.0 × 3.0 m |
| Power Supply | AC 380 V, 50 Hz, 20 kW |
| Required Installation Space | 6 m × 5 m × 3.6 m |
| Accuracy Class | 0.25 (pressure), 3 (air flow), 2.5 (spray), 0.2 (displacement) |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-JM8 |
| Pricing | Available Upon Request |
| Test Medium | Oil, Water, or Ethylene Glycol Mixture |
| Medium Temperature Range | Ambient to 130 °C |
| Maximum Pulse Pressure | 0–70 MPa |
| Pressure Control Accuracy | ±0.01 MPa |
| Pulse Waveform | Square or Stepped Profile |
| Pulse Frequency | 5–60 cycles/min |
| Maximum Continuous Test Cycles | >100,000 (single run) |
| Continuous Operation Duration | ≥240 hours (10 days) |
| Compliance | Designed for ISO 6803, SAE J1401, GB/T 5563, ISO 6802, and FMVSS 106 test protocols |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-JM8 |
| Test Medium | Hydraulic Oil or Ethylene Glycol Mixture |
| Max Test Pressure | 0–5 MPa (adjustable) |
| Pressure Control Accuracy | ±0.01 MPa (full scale dependent) |
| Pulse Frequency | 5–120 cycles/min (adjustable) |
| Pulse Waveform | Square or Trapezoidal (pulse width configurable per user specification) |
| Test Medium Temperature Range | Ambient to 160 °C |
| Environmental Temperature Control Range | −30 °C to 250 °C |
| Maximum Continuous Cycles | >1,000,000 |
| Control Method | PC-based Automated Control with Servo/Proportional Actuation |
| Compliance | Designed for ISO 6803, SAE J1402, GB/T 5563, and ASTM D380-conforming validation protocols |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-JM8 |
| Pricing | Available Upon Request |
| Test Pressure Range | 0–100 MPa |
| Pressure Control Accuracy | ±0.1 MPa |
| Test Media | Compressed Air, Nitrogen, Oxygen, or Other Inert Gases |
| Number of Test Ports | 1 (Configurable) |
| Control System | Servo-Driven Pressure Regulation with PC Interface |
| Data Output | Real-Time Pressure Curve Display, USB Storage, Printable Test Reports |
| Structural Design | Fully Enclosed Frame with Castor-Mounted Mobility |
| Compliance | Designed for ISO 5208, ASTM E493, and EN 1759-2 Prequalification Requirements |
| Brand | Jiubin |
|---|---|
| Model | JB-UV |
| Origin | Shanghai, China |
| Type | UV Germicidal Conveyor Tunnel |
| UV Lamp Configuration | 16 × 20 W low-pressure mercury lamps (254 nm peak) |
| Effective UV Irradiation Zone | 1000 mm |
| Conveyor Length | 2000 mm |
| Inlet/Outlet Height | 200 mm (adjustable) |
| Inlet/Outlet Width | 500 mm |
| Conveyor Height from Floor | 750 ± 50 mm |
| Lamp Tube Length | 600 mm |
| Safety Protections | Overvoltage/overcurrent protection, fault alarm indicator, motor overload protection |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-WD2D |
| Table Diameter | 800 mm |
| Tilting Range | 0–30° ±1° |
| Max Load Capacity | 120 kg |
| Actuation Mode | Manual |
| Rotation Speed | 1 rpm |
| Compliance | GB 4706-1:20.1, IEC 60335-1:20.1 |
| Optional UL-Compliant Range | 0–42° (custom order) |
| Brand | Chengdu Jiangxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | A301 |
| Price Range | USD 310 – 395 |
| Standard Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (optional 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale Range | 7.5–10 cm |
| Probe Rod Material | Stainless Steel |
| Brand | Chengdu JinXin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Bulk Density & Flow Tester |
| Design | Portable Benchtop Unit |
| Measurement Principle | Standard Funnel Flow (Hall Flowmeter) & Gravimetric Bulk Density |
| Applicable Standards | GB/T 1482–2010, GB/T 1479.1–2011 |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| 刮刀 (Steel Ruler) | 25 mm wide, stainless steel 304 |
| Stopper Rod | Stainless steel 304 |
| Dimensions | ≈ 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Required Ancillaries | Analytical balance (max 1 kg, d = 0.02 g), stopwatch (0.01 s resolution) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Instrument Type | Apparent Density & Flow Rate Tester |
| Design | Portable Benchtop Unit |
| Measurement Principle | Standard Funnel Method per GB/T 1482–2010 & GB/T 1479.1–2011 |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Container Height | 25 mm ± 2 mm (adjustable) |
| Funnel Cone Angle | 60° |
| Stainless Steel Components | AISI 304 (funnel, scraper, stopper rod, 25 mL cylinder) |
| Cylinder Volume | 25 mL |
| Overall Dimensions | ~230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Required External Equipment | Analytical balance (max 1000 g, readability 0.02 g) |