| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DCU-600 |
| Instrument Type | Oscillating U-tube Density Meter Accessory |
| Form Factor | Benchtop Laboratory Unit |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0–96 °C |
| Minimum Sample Volume | ~5 mL |
| Compatibility | Designed exclusively for KEM DA-640, DA-645, and DA-650 digital density meters |
| Automation Functions | Automated sample aspiration, measurement triggering, waste discharge, dual-solvent cleaning (Wash 1 & Wash 2), nitrogen-assisted drying, and cell integrity verification |
| Sample Vessel | 20–100 mL beaker or 100 mL disposable cup |
| Power Supply | DC 24 V, 5 A (AC adapter included) |
| Dimensions (W×D×H) | 214 × 295 × 304 mm |
| Weight | Approx. 5.5 kg |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CWT-A1-2 |
| Pricing | Upon Request |
| Brand | KLA |
|---|---|
| Origin | Malaysia |
| Model | R50-4PP / R50-EC |
| Type | Imported Instrument |
| Distribution Channel | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Detection Mode | Liquid Density Measurement |
| Density Range | DS7900: 0.00000–1.99999 g/cm³ |
| DS7800 | 0.0000–1.9999 g/cm³ |
| Density Accuracy | DS7900: ±0.00005 g/cm³ |
| DS7800 | ±0.0001 g/cm³ |
| Repeatability | DS7900: ±0.00001 g/cm³ |
| DS7800 | ±0.0001 g/cm³ |
| Temperature Control Range | 10–40 °C |
| Temperature Stability | ±0.02 °C |
| Sample Volume | 2 mL |
| Measurement Time | 30–60 s |
| Calibration Standards | Dry air and distilled water |
| Calibration Points | 4–10, 3rd-order polynomial fit |
| Data Storage Capacity | 999 results |
| User-Defined Methods | 99 |
| Compliance | ASTM D4052, ASTM D5002, NIST-traceable, GLP/GMP-ready, FDA 21 CFR Part 11 compatible (audit trail enabled) |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | DS7800 |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0.0000–1.9999 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Repeatability | ±0.0001 g/cm³ |
| Temperature Control Range | 10–40 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 0.9 mL |
| Measurement Time | ~5 min |
| Calibration Standards | Dry air and distilled water |
| Compliance | ASTM D4052, ASTM D5002, NIST-traceable, GLP/GMP-ready |
| Data Storage | SQL database (999 results) |
| Interface Options | Ethernet, USB 2.0, RS-232 |
| Display | 5.7″ TFT color LCD (640×480 VGA) |
| Power Supply | 90–264 V AC, 50/60 Hz |
| User Management | Three-level password protection |
| Language Support | 6 languages |
| LIMS Compatibility | Yes |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSA100E |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSA25E |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K100C |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MSA Flexible Liquid |
| Pricing | Available Upon Request |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-SZ2000 |
| Instrument Type | Scott Volumeter |
| Instrument Category | Benchtop Laboratory Densitometer |
| Sample Type | Free-Flowing Metallic Powders |
| Standard Compliance | GB/T 5060–1985 (equivalent to ISO 3923-2) |
| Measurement Principle | Gravimetric Volumetric Method with Controlled Flow Damping |
| Configuration | Integrated Funnel Assembly, Quadruple Baffle System, Cylindrical Receiving Cup (25.0 mL nominal volume), Stainless Steel Straightedge & Tapping Platform |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | C330H |
| Quotation | Upon Request |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing | Optional (up to 3 L) |
| Data Management | DataShield™ Audit-Trail Enabled |
| Compliance Options | 21 CFR Part 11, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C612M |
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Torque Sensor Range | 5 N·m (standard) |
| Accuracy | ±0.5% of reading (10–100% FS) |
| Resolution | 0.0001 N·m |
| Cap Holding Diameter | Φ10–Φ80 mm |
| Bottle Body Holding Diameter | Φ5–Φ170 mm |
| Bottle Height Range | 20–400 mm |
| Max Test Torque | 2 N·m (customizable) |
| Air Supply Requirement | 0.7 MPa (101.5 psi), clean dry air (user-supplied) |
| Statistical Batch Size | 0–999 samples |
| Dimensions (L×W×H) | 550 × 365 × 1150 mm |
| Weight | 39 kg |
| Power | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (dual-voltage compatible) |
| Brand | Labthink |
|---|---|
| Model | GC Series |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application | Quantitative determination of residual ethylene oxide in EO-sterilized medical devices and personal protective equipment (PPE) |
| Detection Principle | Headspace gas chromatography (HS-GC) with flame ionization detection (FID) |
| Compliance Standards | GB/T 14233.1–2008, GB/T 16886.7–2001, ISO 10993-7, ASTM F2573, USP <801>, FDA 21 CFR Part 11 (software-enabled audit trail & electronic signature support) |
| Sample Preparation | Aqueous extraction followed by thermal equilibration in sealed headspace vials |
| Detection Limit | ≤0.1 µg/g (as per method validation per ISO/IEC 17025) |
| Linear Range | 0.5–50 µg/g EO in solid matrix |
| Calibration Method | Gravimetric standard stock solution preparation (1 × 10⁻² g/L), serial dilution, six-point calibration curve |
| Data Output | Peak area or height vs. concentration |
| Brand | Labthink |
|---|---|
| Model | GC-7800 |
| Detection Principle | Headspace Gas Chromatography with Dual FID/TCD Detectors |
| Temperature Control Accuracy | ±0.1°C (sample chambers), ±0.5°C (gas lines & valve oven) |
| Sample Capacity | Dual 300 mL headspace vials |
| Injection Volume | 1.0 mL (optional: 0.5/2/3 mL) |
| Programmable Temperature Ramping | 5-stage linear, 1–30 °C/min |
| Column Oven Stability | <±0.1°C, gradient ≤1% across active zone |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene/H₂) |
| Data System | PC-based chromatography workstation with audit trail, method validation support, and GLP-compliant reporting |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | RCP-50 |
| Capacity | 50 L |
| Operating Temperature Range | ≥10 °C to 135 °C |
| Maximum Working Pressure | 0–0.22 MPa |
| Timer Range | 0–999 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 2 kW |
| Cooling Method | Forced-air cooling with back-pressure compensation |
| Safety Features | Over-temperature, over-pressure, low-water-level, and leakage protection |
| Compliance Documentation | Full set of calibration certificates, verification reports, and metrological traceability records per Chinese National Verification Regulation JJG 974–2021 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W3/062 |
| Pricing | Available Upon Request |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | CryoComplete |
| Pricing | Upon Request |
| Temperature Range | 77 K to 500 K |
| Resistance Measurement Range | 100 µΩ to 1 GΩ (standard) |
| Cryogen | Liquid Nitrogen |
| Vacuum Environment | Yes |
| Temperature Stability | ±50 mK |
| LN₂ Capacity | 1.2 L |
| Cool-down Time to 77 K | 15 min |
| Hold Time at 77 K | 8 h |
| Optical Windows | 4 quartz windows |
| Sample Mounting | Pre-wired 8-pin board |
| Measurement Modes | DC, AC (sine/triangle/square), lock-in (3 full channels) |
| Source Current Range | 1 pA to 100 mA |
| Source Frequency Range | 100 µHz to 100 kHz (square wave <5 kHz) |
| Max Measured Voltage | 10 V |
| Input Impedance | >10 GΩ (differential) |
| Sample Leakage Current | 50 pA @ 10 V (coaxial) or 50 fA @ 10 V (guarded triaxial) |
| Voltage Noise | <5 nV/√Hz @ 83 Hz |
| 1/f Voltage Noise (sample test) | <100 nV |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCM-2 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCM-3 |
| Pricing | Available Upon Request |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Product Type | Imported Instrument |
| Model | AMH55 |
| Instrument Category | Microhardness Tester |
| Measurement Range | 0–2000 HV (typical for Vickers microhardness) |
| Total Test Force | 1–60 kgf |
| Test Space (X × Y) | 260 × 150 mm |
| Automation Level | Fully Automated / Semi-Automated / Lite Configurations Available |
| Software Platform | Cornerstone® v5.0+ |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample Phase | Liquid |
| Application Focus | Petroleum Products Density Measurement |
| Density Range | 0.6–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 15–40 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.03 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | ASTM D4052, ISO 12185, IP 365, GB/T 1884 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Oscillating U-Tube Densimeter |
| Portability | Portable |
| Sample Phase | Liquid |
| Application Focus | Petroleum Products Density Measurement |
| Density Range | 0.6–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 15–40 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.03 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | ASTM D4052, ISO 12185, IP 365, GB/T 1884 |
| Brand | LEMIS / LEMIS Baltic |
|---|---|
| Model | DM-230.2A |
| Density Range | 0.6500–1.1000 g/cm³ |
| Density Accuracy | ±0.0005 g/cm³ (typical, per ISO 12185) |
| Operating Temperature Range | −40 to +85 °C |
| Submersion Depth | Up to 30 m |
| Data Storage Capacity | 998 measurements |
| Wireless Interface | Integrated Bluetooth® 4.2 for PC and portable printer connectivity |
| Calibration Compliance | Traceable to NIST and PTB standards |
| Hazardous Area Certification | ATEX II 2G Ex ib IIB T4 Gb / IECEx Ex ib IIB T4 Gb |
| Regulatory Listing | Registered in the State Register of Measuring Instruments (Eurasian Economic Union) |
| Brand | HOYTOM |
|---|---|
| Origin | Spain |
| Model | Link RB |
| Test Height | 170 mm |
| Compliance | EN ISO 6508, ASTM E18, EN ISO 6506, ASTM E10 |
| Optional Accessories | HOYTOM LHB Digital Brinell Impression Measurement System, USB Digital Microscope (20×/30×/40×), Integrated Data Logging Software |
| Brand | Linos |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 011 |
| Pricing | Upon Request |
| Type | Amplitude Modulator (EO-AM-NR) / Phase Modulator (EO-PM-NR) |
| Crystal Material | Lithium Niobate (LiNbO₃) |
| Wavelength Ranges | C1: 600–900 nm |
| C2 | 900–1250 nm |
| C3 | 1250–1650 nm |
| C4 | 400–600 nm |
| Aperture | 2 mm |
| Input Connector | SMA Female |
| Half-Wave Voltage (Vπ) | 360 V @ 1064 nm (Typ.) for EO-AM-NR |
| Max. Optical Power Density | 2 W/mm² @ 532 nm, 4 W/mm² @ 1064 nm |
| Bandwidth | DC to 100 MHz |
| Coupling | DC-coupled |
| Brand | TOYO Corporation |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EC-1 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LIT |
| Pricing | Upon Request |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Model | LOW TEMPERATURE XYZ PIEZO SCANNER |
| Scanning Range | 50 × 50 × 24 µm @ 300 K, 30 × 30 × 15 µm @ <4 K |
| Operating Temperature Range | 10 mK – 300 K |
| Maximum Magnetic Field Tolerance | 40 T |
| Actuator Material | Piezoceramic stack integrated with titanium and alumina ceramic housing |
| Structural Components | Stainless steel screws, oxygen-free copper wiring, FR4 PCB substrate |
| Feedback Option | Closed-loop operation available per axis with heterodyne fiber interferometry (1–10 µW optical power per axis) |
| Mass | 16 g |
| Dimensions | 24 × 24 × 9.2 mm |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LT-sSNOM |
| Price | Upon Request |
| Wavelength Range | 532 nm – 20 µm (with metallic reflective optics) |
| AFM Scanner | Fiber-interferometer-equipped piezoelectric stage, scan range 30 × 30 × 15 µm (@ 4 K) |
| XYZ Sample Nanopositioner | 6 × 6 × 12 mm travel |
| Off-Axis Parabolic Mirror Nanopositioner | 4 × 4 × 6 mm travel |
| Position Sensor Resolution | 200 nm (resistive) |
| Outer Diameter | 49 mm |
| Temperature Range | 10 mK – 300 K |
| Maximum Magnetic Field | 31 T |
| Electrical Contacts | 8-point feedthrough on sample stage |
| Supported AFM Modes | Contact, Dynamic, Non-Contact (ncAFM), Magnetic Force Microscopy (MFM), Conductive AFM (cAFM), Kelvin Probe Force Microscopy (KPFM), Photoinduced Force Microscopy (PRFM), Electrostatic Force Microscopy (EFM) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LSM Series |
| Price | Upon Request |