| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LF-TD 180 |
| Instrument Type | Thermo-Hygrometer |
| Humidity Range | 0–100 % RH |
| Temperature Range | –20 °C to +180 °C |
| Humidity Accuracy | ±2.0 % RH (10–90 % RH) |
| Temperature Accuracy | ±0.3 °C (+10 to +60 °C) |
| Output Signals | Dual 4–20 mA (RH and Temp, separately scaled) |
| Power Supply | 12–29 VDC (nominal 24 VDC) |
| Sensor Head Material | Stainless steel |
| Electronics Housing Material | Anodized aluminum |
| IP Rating | IP65 |
| Probe Dimensions | Ø12 mm × 100 mm |
| Electronics Dimensions | 70 mm (W) × 32 mm (H) × 120 mm (D) |
| Cable Length | 1 m (5-pin sensor connector) |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFrac |
| Quotation | Upon Request |
| Principle | Centrifugal Fracture Testing (Dynamic Load Application via Rotating Rotor) |
| Max. Centrifugal Force Range | 0.1 N – 6.5 kN |
| Rotational Speed Range | 100 – 13,000 rpm |
| Tensile Strength Measurement Range | up to 80 MPa |
| Sample Capacity | 8 parallel specimens |
| Sample Dimensions | max. 30 × 30 × >1 mm³ |
| Bonded Area Diameter | 7 mm, 10 mm or custom |
| Bonded Surface Materials | metallic & non-metallic substrates |
| Specimen Mass Range | 4.1 g – 38.7 g (Cu/W-based reference: ~58 g) |
| Temperature Control Range | −11 °C to +40 °C |
| Measurement Duration | 1 min – 99 h |
| Compliance | ISO 4624, DIN EN 15870, DIN EN 14869-2, JIS K 5600-5-7 |
| Data Interface | USB |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Max. Power Consumption | 1050 W |
| Net Weight | 56 kg |
| Dimensions (W×H×D) | 380 × 296 × 640 mm³ |
| Software Platform | SEPView® v6.x with real-time critical force calculation, statistical comparison, GLP-compliant audit trail, and FDA 21 CFR Part 11-ready user access control |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFuge |
| Price | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LUMiReader PSA |
| Pricing | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiReader X-Ray |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5300 |
| Pricing | Upon Request |
| Channel Count | 256–100,000 (in multiples of 256) |
| Voltage Range | 0–5.0 V |
| Max Charge Current | 1.5 A or 2.5 A |
| Max Discharge Current | 2.5 A |
| Voltage Accuracy | ±5 mV |
| Current Accuracy | ±2 mA |
| Energy Accuracy | ±0.2 mAh/hour |
| Min Discharge Cutoff Voltage | 2.0 V |
| Max Charge Voltage Limit | 5.0 V |
| Termination Criteria | 16 programmable conditions including time, voltage, current, dV/dt, capacity, coulombic efficiency, and ΔV |
| Data Logging Interval | As low as 1 minute per cell |
| Independent Channel Control | Yes |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8500 Series |
| Quotation | Upon Request |
| Voltage Range | Up to 1000 V |
| Current Range | Up to 1000 A |
| Minimum Step Time & Data Acquisition Interval | 50 ms (standard), optional sub-50 ms capability |
| Operating Modes | Galvanostatic (CC), Potentiostatic (CV), Power Control (CP), Resistance Control (CR), and hybrid step sequencing |
| Regenerative Energy Recovery | Grid-to-Battery (G2B) and Battery-to-Grid (B2G) bidirectional architecture |
| Software Platform | MACCOR Test Executive v7.x or later |
| Brand | MAYZUM |
|---|---|
| Model | MAYA203DIV2L |
| Type | Benchtop Solid Density Analyzer for Hydrogen Quantification in Aluminum Melts |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | −30 °C to +60 °C |
| Display | Digital LCD |
| Origin | Guangdong, China |
| Manufacturer | MAYZUM (OEM/ODM Capable) |
| Compliance | GB/T 43139–2023, GB/T 5611–2017, ASTM E807 (adapted), ISO 11922 (principles) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MAYB124G |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0.0001–3.0000 g/cm³ (equivalent to 0.1–100% concentration for common aqueous/organic solutions) |
| Maximum Sample Weight Capacity | 120 g |
| Density Resolution | 0.0001 g/cm³ |
| Display | Digital LCD |
| Compliance Standards | GB/T 13531, GB/T 5526, GB/T 5009, ASTM D1298, ASTM D4052, JIS K 0061, ISO 12185 |
| Measurement Principle | Archimedean buoyancy displacement method |
| Brand | Mayzum |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MZ-Y300 |
| Instrument Category | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Solid Porous Materials |
| Density Range | 0.01–99.999 g/cm³ |
| Maximum Capacity | 300 g |
| Density Resolution | 0.001 g/cm³ |
| Display | Digital LCD |
| Application Scope | Universal Density Testing for Open- and Closed-Cell Porous Polymers |
| Compliance Context | Designed to support ASTM D3574, ISO 845, ISO 1183-1, and GB/T 6343 test protocols |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC010-HBa-1 |
| Pricing | Upon Request |
| Measurement Range | 0–100 HBa (equivalent to 25–150 HBW) |
| Indenter | 26° truncated conical tip, flat end diameter 0.176 mm |
| Resolution | 0.5 HBa |
| Accuracy | ±2 HBa (42–52 HBa), ±1 HBa (84–88 HBa) |
| Repeatability | ±2 HBa (42–52 HBa), ±1 HBa (84–88 HBa) |
| Weight | 0.5 kg |
| Compliance | GB/T 3854–2005, ASTM B648–2000 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC010-LX-C |
| Quotation | Upon Request |
| Scale Range | 0–100 HW |
| Recommended Measurement Range | 10–90 HW |
| Indenter Travel | 2.5 mm |
| Indenter Tip Radius | SR 2.5 mm |
| Dimensions | 115 × 60 × 25 mm |
| Weight | ~0.5 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC010-TH110 |
| Price | Upon Request |
| Measurement Range | 170–960 HLD |
| Indication Error | ±6 HLD (at HLD = 760 ± 30) |
| Repeatability Error | <6 HLD (at HLD = 760 ± 30) |
| Operating Temperature | 0–40 °C |
| Power Supply | 4.7–6.0 V DC |
| Battery | Ni-MH rechargeable pack (approx. 4 h charging time) |
| Weight | 0.615 kg |
| Hardness Scales Supported | HL, HRB, HRC, HB, HV, HS |
| Tensile Strength Conversion | Yes |
| Impact Device Compatibility | 7 types (auto-recognized, no recalibration required) |
| Data Display | Measured value, average, date/time, impact direction, impact count, material code, hardness value |
| Calibration | Software-based soft calibration function |
| Low-voltage alarm & charging status indicator | Yes |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MD-J |
| Pricing | Available Upon Request |
| Measurement Range | 0.8–3.5 g/cm³ |
| Sample Mass | 5–12 g |
| Accuracy | ±1% |
| Scale Graduation | 0.01 (0.8–2.0), 0.02 (2.0–2.5), 0.05 (2.5–3.5) g/cm³ |
| Sample Requirements | Bubble-free, smooth-surfaced, oil- and contaminant-free specimens |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MDZ-II |
| Pricing | Available Upon Request |
| Maximum Sample Volume | 40 cm³ |
| Accuracy | ±0.15% |
| Repeatability | ±0.05% |
| Density Resolution | 0.0001 g/cm³ |
| Carrier Gas | High-Purity Helium or Nitrogen |
| Operating Pressure | ~1.25 atm |
| Dimensions | 385 × 335 × 200 mm |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Model | CDM-M |
| Maximum Energy | 100+ kJ |
| Default Energy | 4 kJ |
| Modular Energy Block | 4 kJ |
| Peak Voltage | 3 kV |
| Interface | RS232 |
| Control Architecture | High-precision programmable controller |
| Compliance | Designed for industrial integration per IEC 61000-4 electromagnetic compatibility standards |
| Cooling | Forced-air or optional liquid cooling |
| Pulse Rise Time | <100 µs (typical, dependent on coil inductance and load) |
| Peak Current Capability | Up to 50 kA (custom configurations) |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoPulse-BI |
| Pricing | Upon Request |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Model | HyMAC |
| Frequency Range | 5–2500 Hz |
| Output Power | 1200 VA (optional 3 kVA) |
| Maximum Field Strength | 10 kA/m or 1.7 T |
| Measurement Outputs | Hc, Br, Bm, Hm, Core Loss, Permeability, Eddy Current Loss, Hysteresis Loss |
| Operating Modes | Rapid Prediction Mode, Fixed-Field Mode, Swept-Field Mode |
| Compliance | IEC 60404-2, IEC 60404-3, IEC 60404-6 |
| Sample Fixtures | Epstein frame, Single Sheet Tester (SST), Toroidal core fixture, Yoke-based clamping systems |
| Software Interface | Windows-native GUI with real-time waveform display, automated parameter extraction, and export to CSV/Excel |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Model | HyMPulse |
| Measurement Principle | Pulsed-field magnetization with four-quadrant hysteresis loop acquisition |
| Maximum Field | >16 T |
| Energy Storage Capacity | 28 kJ (expandable) |
| Standard Measurement Coil | 6.5 T, 50 mm bore diameter |
| Sample Temperature Range | 20–180 °C |
| Software Platform | Windows-based proprietary control and analysis suite |
| Output Parameters | Br, HcB, HcJ, Hknee, (BH)max, Hmax |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Distributor Type | General Distributor |
| Import Status | Imported |
| Cooling Options | Natural Convection, Forced Air, Liquid Cooling |
| Design Methodology | CAD-Based Mechanical Design & Finite Element Analysis (FEA) for Magnetic Flux and Structural Optimization |
| Compliance Framework | Designed for integration with industrial magnetizing power supplies compliant with IEC 61000-4 series EMC standards and ISO 9001-certified manufacturing processes |
| Packaging | Custom Protective Enclosure for Transit and Storage |
| Reusability | High-cycle mechanical durability with precision-machined ferromagnetic pole pieces and non-magnetic structural housing |
| Brand | Metis |
|---|---|
| Origin | Belgium |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito 30PX |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Density Range | 0 to 2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 5–35 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Compensation | Yes, user-selectable coefficient |
| Sample Types | Liquids and low-viscosity solutions |
| Compliance | ASTM D7777, ISO 12185, USP <841>, GLP/GMP-ready data logging |
| Data Storage | Up to 1100 measurements with timestamp, sample ID, temperature correction factor, instrument ID |
| Interface | Infrared (IR), RS232 via optional IR/RS232 converter (P/N 51325006) |
| Display | Backlit dot-matrix LCD with icon-based navigation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / Densito Pro |
| Density Measurement Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 0–50.0 °C |
| Minimum Sample Volume | 2 mL |
| Instrument Type | Portable Digital Density Meter (Oscillating U-tube Principle) |
| Application Scope | Liquid Density Measurement for QC/QA in Lab, Field, and Production Environments |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito |
| Instrument Type | Portable Digital Density Meter |
| Sample Type | Solids and Liquids |
| Density Range | 0.000–3.000 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Operating Temperature Range | −10 °C to +50 °C |
| Measurement Units | g/cm³, g/mL, kg/m³, °Brix, API, °Baumé, % ethanol (v/v), % H₂SO₄, US/UK Proof, Plato, specific gravity, user-defined concentration scales |
| Data Storage Capacity | 1100 measurements with sample ID, temperature correction factor, instrument ID, timestamp, and unit |
| Display | Full-color backlit LCD |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, optional printer output, compatible with EasyDirect PC software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4 / D5 / D6 |
| Instrument Type | Benchtop Laboratory Density Meter |
| Sample Type | Solid and Liquid |
| Temperature Range | 0–95 °C (32–203 °F) |
| Repeatability | ±0.00005 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.0001 / ±0.00005 / ±0.000005 g/cm³ (model-dependent) |
| Temperature Accuracy | ±0.03 / ±0.02 / ±0.01 °C (model-dependent) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4/D5/D6 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Sample Type | Liquids and Low-Viscosity Solutions |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 0 °C to 95 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | 21 CFR Part 11 Ready (with LabX software), GLP/GMP Audit Trail Capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / DensitoPro |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Sample Temperature Range | 0–50 °C |
| Ambient Temperature Range | Densito: −10–50 °C |
| DensitoPro | 0–50 °C |
| Data Storage Capacity | 1,100 results |
| Supported Units | Density, Specific Gravity, Brix, API Gravity, Baumé, Ethanol (% v/v), H₂SO₄ Concentration, US/UK Proof, Plato, User-Defined Concentrations |
| Display | Full-color backlit LCD |
| Languages | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, Bluetooth (DensitoPro), RFID/Barcode Reader (DensitoPro only) |
| Software Integration | EasyDirect PC Software |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready data export |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DM40 |
| Density Measurement Range | 0.0000–3.0000 g/cm³ |
| Density Repeatability (SD, n=10) | 0.00005 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (typical) |
| Temperature Control Range | 0–91 °C |
| Minimum Sample Volume | 1 mL |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (vibrating tube) densitometry |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 270, DIN 51757 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D30/D40 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Vibrating Tube) |
| Sample Type | Liquids |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00002 g/cm³ |
| Temperature Control Range | 0 to 91.0 °C |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 160, DIN 51757 |
| Data Management | FDA 21 CFR Part 11 compliant software support (via EasyDirect™), GLP/GMP audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy D30, Easy D40 |
| Instrument Type | Benchtop Digital Density Meter |
| Sample Type | Solid and Liquid |
| Density Range | 0–3 g/cm³ |
| Temperature Range | 15–25 °C (Easy D30), 15–50 °C (Easy D40) |
| Density Resolution | 0.001 g/cm³ (Easy D30), 0.0001 g/cm³ (Easy D40) |
| Density Accuracy | ±0.001 g/cm³ (Easy D30), ±0.0005 g/cm³ (Easy D40) |
| Temperature Accuracy | ±0.2 °C (Easy D30), ±0.1 °C (Easy D40) |
| Minimum Sample Volume | 1.2 mL |
| Measurement Units | Density, Specific Gravity, Alcohol % v/v, Brix, API Gravity, Acidity, Urea Concentration, Custom Concentration |
| Built-in Methods | 16 |
| Bubble Detection | BubbleCheck™ (Easy D40 only) |
| Viscosity Correction | Automatic (both models) |
| Cleaning Check | Yes (both models) |
| Dimensions (W × H × D) | 170 × 156 × 273 mm |