| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | FillPal™, InMotion™, SC1(H), SC30(H) |
| Application Scope | Fully automated sample introduction, rinsing, drying, and (where applicable) heating for density and refractive index measurement |
| Compliance Context | Designed to support GLP/GMP workflows with audit-trail-capable software integration |
| Fluid Handling Architecture | Positive-pressure filling (SC-series), peristaltic pumping (FillPal/InMotion), chemically resistant wetted materials (e.g., PTFE, ETFE, sapphire, Hastelloy C-276 where specified) |
| Temperature Control | Ambient-only (FillPal, InMotion, SC1/SC30) or heated up to 100 °C (SC1H/SC30H) |
| Sample Capacity | 1 (FillPal, SC1, SC1H) or up to 303 positions (InMotion), or 30 vials (SC30, SC30H) |
| Cleaning Protocol | Full-cycle automated rinse-dry sequence with configurable solvent selection and dwell times |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SC1 / SC30 |
| Sample Capacity | 1 vial (20 mL, 9 mL, or 6 mL) |
| Maximum Sample Viscosity | ≤ 30,000 mPa·s |
| Sample Introduction Method | Positive-pressure pumping |
| Cleaning Protocol | Dual-solvent automated rinse and dry |
| Drying Method | Pneumatic-assisted air-drying |
| Temperature Control | Optional electric heating module (for sample pre-conditioning) |
| Sample Recovery | Optional automatic return to source vial |
| Compliance | Designed for integration with METTLER TOLEDO DE (density), RE (refractometry), and DR (combined density/refractometry) instruments |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | BSDX |
| Pricing | Available Upon Request |
| Brand | Kägi |
|---|---|
| Origin | Germany |
| Model | Micro IRHD |
| Instrument Type | Microindentation Hardness Tester for Elastomers |
| Standards Compliance | DIN ISO 48, ISO 48:2018, ASTM D1415-19, BS 903-A26 |
| Sample Thickness Range | 1–5 mm (recommended), up to 90 mm (with optional fixtures) |
| Resolution | 0.1 Micro IRHD |
| Dimensions (Tester) | Ø200 mm × 470 mm |
| Dimensions (Controller) | 290 mm × 260 mm × 75 mm |
| Weight | 17.5 kg |
| Control Interface | RS232 serial communication with Windows PC |
| Automation | Motorized Z-stage, programmable dual-weight actuation, auto-positioning sample stage |
| Software Platform | Native MS Windows application with real-time data acquisition, statistical analysis, hysteresis calculation, report generation (PDF/CSV), label printing, and ASCII export |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MicroLOG Pro EC750 Pocket-Sized Temperature & Humidity Data Logger |
| Temperature Range | –40 to +80 °C |
| Relative Humidity Range | 0–100 %RH |
| Temperature Accuracy | ±0.2 °C |
| RH Accuracy | ±2 %RH @ 25 °C |
| Temperature Resolution | 0.1–0.2 °C (varies by range) |
| RH Resolution | 0.1 %RH |
| Memory Capacity | 52,000 data points |
| Sampling Interval | 10 s to 2 h |
| Display | 4-digit LCD with unit indicators (°C/°F/%RH/PH/V/mA/mS/AL-H/AL-L) |
| Communication | RS-232 (19.2 kbps), USB 1.1, IrDA (compatible with HP 82240B printer) |
| Power | 3.6 V Li primary battery (½AA, 1.2 Ah) |
| Battery Life | ~2 years (typical use, no external sensors or high-frequency sampling) |
| Dimensions | Ø72 mm × 22.9 mm |
| Weight | 55 g |
| Certifications | CE, FCC |
| Software | MicroLAB 1.1 (free, Windows-compatible) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | USA |
| Manufacturer | Micromeritics Instrument Corporation |
| Model | AccuPyc III 1350 |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop Laboratory System |
| Sample Type | Solid Materials |
| Density Range | 0.1–100 cm³ (sample volume) |
| Density Accuracy | ±0.02% |
| Temperature Control Range | 4 °C to 60 °C, stability ±0.025 °C |
| Repeatability | ±0.01% |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AccuPyc III 1350 |
| Instrument Type | True Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Form | Solid Powders, Granules, Monoliths |
| Measurement Principle | Gas Displacement (Helium/Nitrogen/Air) |
| Density Range | 0.1–100 cm³ (Sample Volume Capacity) |
| Accuracy | ±0.02% |
| Repeatability | ±0.01% |
| Temperature Control Range | 4 °C to 60 °C |
| Temperature Stability | ±0.025 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Compliance | ASTM D5550, ISO 12154, USP <699>, GLP/GMP-ready audit trail support |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASAP 2020 |
| Pricing | Available Upon Request |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | GeoPyc 1365 |
| Instrument Type | Benchtop Envelope Density Analyzer |
| Sample Form | Solids (powders, granules, irregular solids, tablets, foams) |
| Measurement Principle | Solid displacement using Dry Flo™ quasi-fluid medium |
| Envelope Volume Range | 0.3–25 cm³ (via interchangeable sample cups) |
| Density Accuracy | <0.15% deviation vs. ASTM D1895, D6342, D7481 |
| Operating Temperature | 15–35 °C |
| Minimum Sample Requirement | ≥25% of selected cup volume |
| Compliance | ASTM D1895 (Type A), D6342, D7481, ISO 697, USP <699>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Optional T.A.P. Density Module | Programmable consolidation force (0.5–10 N), stepwise compression cycles, real-time force & displacement monitoring |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELPYCNO L |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory Analyzer |
| Sample Type | Solids, Powders, Pastes, Liquids |
| Measurement Principle | Gas Displacement Pycnometry (Helium-Based) |
| Pressure Range | Vacuum to 2.5 bar |
| Temperature Control Range | 14–40 °C (Peltier-Driven, Optional) |
| Temperature Stability | ±0.01 °C |
| Density Accuracy | ±0.01% |
| Density Repeatability | ±0.01% |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Standard Sample Cell Volumes | 20 mL, 40 mL, 60 mL |
| Optional Sample Cell Volumes | 4 mL, 100 mL |
| Reference Cell Configuration | Three Integrated Reference Cells |
| Pressure Sensor | High-Stability Absolute Sensor (0–2.5 bar), 19-bit A/D, Drift ≤ ±0.02 mbar |
| Gas Options | He (standard), N₂, SF₆ |
| Inlet Pressure Range | 160–240 kPa (1.6–2.4 bar) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 4590, ASTM D6226-10 |
| Interface | RS-232 (COM) or USB |
| Dimensions (W×H×D) | 25 × 33 × 45 cm |
| Weight | 17 kg |
| Operating Environment | 15–30 °C, 20–80% RH |
| Power | 85–264 VAC, 50/60 Hz, 240 W |
| Brand | Microtrac |
|---|---|
| Model | BELPYCNO |
| Type | Benchtop True Density Analyzer for Solids |
| Measurement Principle | Gas Pycnometry (Helium/Nitrogen/SF₆) |
| Density Range | All Solid Materials |
| Density Accuracy | ±0.0001 g/cm³ |
| Repeatability | ±0.01% (RSD) |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Temperature Range | 15–35 °C (standard) |
| Pressure Range | Atmospheric to 150 kPa |
| Safety Features | Integrated pressure relief valve |
| Calibration Standards | Internal calibration spheres (multiple sizes) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 18857-1 |
| Software | BELPyCNOSoft v3.x with audit trail, user management, and 21 CFR Part 11 compliance options |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1000 |
| Price Range | USD 14,000 – 28,000 |
| Sample Length | 2–10 mm |
| Voltage Resolution | 50 nV |
| Gain Mismatch Between Sample and Reference | <0.1% |
| Repeatability Cycles | Up to 128 (with automated averaging) |
| Temperature Range Options | 70–730 K, 80–580 K, 70–580 K, 80–730 K, or RT–730 K |
| Measurement Method | Differential Comparative Technique |
| Optional Integration | Hall Effect Module |
| Origin | Russia |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MMS |
| Pricing | Upon Request |
| Cooling Medium | Liquid Nitrogen |
| Operating Temperature Range | 110–365 K |
| Magnetocaloric Temperature Change Range | ≥0.1 K |
| Temperature Stability During Measurement | ±0.05 K |
| Magnetic Field Range | 0.02–1.8 T |
| Magnetic Field Ramp Rate | 0.05–6 T/s |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | DZ5001 |
| Price Range | USD 2,800 – 7,000 |
| Measurement Principle | Resonant Cavity / Series/Parallel Resonance Method (Q-factor based) |
| Frequency Range | 10 kHz – 100 MHz (DDS Synthesized, 7000:1 Sweep Ratio) |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Inductance Measurement Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Accuracy | <3% |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Dielectric Constant (εᵣ) Display Accuracy | ±0.001 (3-digit decimal) |
| Loss Tangent (tan δ) / Dissipation Factor Accuracy | ±0.0001 (4-digit decimal) |
| Sample Thickness Range | 0.1 mm – 10 mm |
| Residual Inductance Compensation | Automatic (integrated lead & fixture inductance nulling) |
| Compliance Standard | GB/T 1693–2007 |
| Brand | Nanjing Dazhan |
|---|---|
| Model | DZ5001 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Signal Source | DDS Digital Synthesis |
| ADC Resolution | 12-bit |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| Automatic Capacitance Search | Yes (stepper motor-driven) |
| Resonance Detection | Auto-scan |
| Q Pass/Fail Threshold | Programmable (5–1000) |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc. |
| Residual Inductance Compensation | Supported |
| Test Lead Inductance Compensation | Supported |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ5001 |
| Price Range | USD 2,800 – 7,000 |
| Measurement Principle | Resonant Cavity / Series Resonance Method with Automatic Q-Factor Tracking |
| Frequency Range | 10 kHz – 100 MHz (DDS Synthesized, 7000:1 Sweep Ratio) |
| Frequency Accuracy | ±3×10⁻⁵ ±1 digit (6-digit resolution) |
| ADC Resolution | 12-bit |
| Q Factor Range | 1–1000 (Auto/Manual Range, 4-digit display, 0.1 resolution) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution, <3% error) |
| Main Tuning Capacitor | 17–240 pF (monolithic silver-plated, high-stability) |
| Capacitance Direct Measurement | 1 pF – 25 nF (±1 pF or <1%, 0.1 pF resolution) |
| Capacitance Auto-Search | Stepper-motor-driven |
| Dielectric Constant (εᵣ) Accuracy | ±0.001 (LCD direct readout) |
| Dissipation Factor (tan δ) Accuracy | ±0.0001 (LCD direct readout) |
| Sample Thickness Range | 0.1 mm – 10 mm |
| Compliance | GB/T 1693–2007 |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ5001 |
| Price Range | USD 2,800 – 7,000 |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| ADC Resolution | 12-bit |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic construction) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| Automatic Resonance Search | Yes (stepper motor-driven) |
| Displayed Parameters | F, L, C, Q, Lt, Ct, εᵣ, Tn |
| Residual Inductance Compensation | Yes |
| Lead Inductance Compensation | Yes |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ5001 |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Inductance Measurement Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Accuracy | <3% |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Dielectric Constant (εᵣ) Display Accuracy | ±0.001 |
| Dissipation Factor (tan δ) Display Accuracy | ±0.0001 |
| Sample Thickness Range | 0.1 mm – 10 mm |
| Compliance | GB/T 1693–2007 |
| Auto-Null Function | Residual inductance & lead inductance compensation |
| Tuning Capacitor | 17–240 pF (silver-plated monolithic) |
| Resonance Search | Motorized auto-scan |
| Display | LCD showing F, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ, etc. |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ 5001 |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Sampling Resolution | 12-bit ADC |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| Automatic Resonance Search | Yes (stepper motor–driven) |
| Display Parameters | F, L, C, Q, Lt, Ct, Er, Tn, residual inductance, lead inductance correction |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DZ5001 |
| Price Range | USD 1,400 – 4,200 |
| Measurement Principle | High-Frequency Resonance Method (Series/Parallel Resonant Circuit) |
| Frequency Range | 10 kHz – 100 MHz (DDS Synthesis, 7000:1 Sweep Ratio) |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Capacitance Range | 1 pF – 25 nF (Direct Readout, ±1 pF or <1% error, 0.1 pF resolution) |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution, <3% error) |
| Q Factor Range | 1–1000 (4-digit display, 0.1 Q resolution, <5% measurement error) |
| Dielectric Constant (εᵣ) Accuracy | ±0.1% (3-digit LCD readout) |
| Dissipation Factor (tan δ) Accuracy | ±0.01% (4-digit LCD readout) |
| Sample Thickness Range | 0.1 mm – 10 mm |
| Auto-Nulling | Residual inductance & lead inductance compensation |
| Compliance | GB/T 1693–2007 |
| Brand | Nanjing Dazhan |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-factor based) |
| Frequency Range | 10 kHz – 100 MHz |
| Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Inductance Measurement Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Accuracy | <3% |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Dielectric Constant (εᵣ) Accuracy | ±0.001 (0.1%) |
| Dissipation Factor (tan δ) Accuracy | ±0.0001 (0.01%) |
| Sample Thickness Range | 0.1 mm – 10 mm |
| Compliance Standard | GB/T 1693–2007 |
| Display | LCD with real-time parameters (F, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ) |
| Tuning Mechanism | Motorized auto-search capacitance bridge (17–240 pF main capacitor, silver-plated monolithic construction) |
| ADC Resolution | 12-bit |
| Signal Source Stability | 3×10⁻⁵ ±1 digit (6-digit frequency precision) |
| Brand | Nanjing Dazhan |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Inductance Measurement Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Accuracy | <3% |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Dielectric Constant (εᵣ) Accuracy | ±0.001 (0.1%) |
| Dissipation Factor (tan δ) Accuracy | ±0.0001 (0.01%) |
| Sample Thickness Compatibility | 0.1 mm – 10 mm |
| Compliance | GB/T 1693–2007 |
| Auto-Nulling | Residual inductance & lead inductance compensation |
| Tuning Capacitor | 17–240 pF (silver-plated monolithic) |
| Capacitor Search | Motorized step-driven auto-tuning |
| Display | Multi-parameter LCD (f, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DZ5001 |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Capacitance | 17–240 pF (silver-plated monolithic) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Automatic Residual Inductance Compensation | Yes |
| Sample Thickness Range | 0.1–10 mm |
| tanδ Resolution | 1×10⁻⁴ |
| εᵣ Resolution | 1×10⁻³ |
| Compliance | GB/T 1693–2007 |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NMI CRYOSTAT: CRYOGENFREE ULTRA LOW-VIBRATION CRYOS |
| Maximum Magnetic Field | 14.0 T |
| Temperature Range | 1.3 K to 300 K |
| Sample Diameter | Up to 49 mm |
| VTI Configuration | Top-Loading Variable-Temperature Insert |
| DSV Homogeneity | ≤0.1% over 1 cm |
| Brand | NanOsc AB |
|---|---|
| Origin | Sweden |
| Model | PhaseFMR / CryoFMR Series |
| Frequency Range | 2–40 GHz |
| Temperature Range | Room Temperature to 4 K |
| Magnetic Field Range | ±0.7 T to ±16 T (platform-dependent) |
| Frequency Accuracy | ±0.05 GHz |
| SNR | >10 for 10 nm Ni₈₀Fe₂₀ at 40 GHz |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | H-12 |
| Weight | 8 g |
| Overall Length | 80 mm |
| Heating Rod Diameter | 7 mm |
| Heating Rod Length | 65 mm |
| Material | High-grade stainless steel and heat-resistant polymer |
| Mounting Type | Standard 3-axis micromanipulator compatible (e.g., MO-10, MN-151) |
| Operating Temperature Range | Ambient to 120 °C (with optional external controller) |
| Compliance | CE-marked for laboratory use |
| Brand | Narishige |
|---|---|
| Model | HD-21 |
| Origin | Japan |
| Type | Dual-Pipette Manipulation Handle |
| Dimensions | 127 mm (W) × 38 mm (D) × 52 mm (H) |
| Weight | 105 g |
| Accessories | Universal Wrench |
| Category | Physical Property Testing Instruments — Other Manipulation & Handling Accessories |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UST-3A |
| Dimensions | 70 × 42 × 35 mm (W × D × H) |
| Weight | 55 g |
| Compatibility | Designed for UST-3 universal joint base and EMM2/NMN-21 micromanipulator electrodes |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ND-11 |
| Pricing | Upon Request |
| Measurement Parameters | Reflectance Density (OD), Reflectance (%) |
| Measurement Range | 0.00–100.0% (Reflectance), 0.00–3.00 D (Optical Density) |
| Aperture Sizes | Φ3.0 mm, Φ1.7 mm, Φ1.0 mm |
| Illumination/Reception Geometry | 0° vertical illumination / 45° annular edge reception |
| Accuracy (Repeatability) | ±0.01 D (≤2.0 D, Φ3.0 mm) |
| Data Compensation Function | Yes, for cross-model result compatibility |
| Averaging Function | 2–9-point reflectance intensity averaging |
| Data Storage Capacity | Up to 500 measurements |
| Dimensions | 210 × 72 × 50 mm (L × D × H) |
| Weight | 530 g (including Ni-Cd battery) |
| Power Supply | Built-in 4.8 V / 800 mAh Ni-Cd rechargeable battery |
| Light Source | Tungsten-halogen lamp (CCT ≈ 2856 K) |
| Optional Accessories | Serial printer PR-95, RS-232 cable, PC software for Excel-compatible data export, calibration standard plates |
| Brand | FJW |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NewOpto 85720 / 85700 / 85726 / 85706 |
| Spectral Sensitivity | 400–1800 nm (85720/85700) / 400–2200 nm (85726/85706) |
| Displayed Regions | Visible, Near-IR, Mid-IR |
| Peak Sensitivity | 600 nm |
| Focal Range | 4 inches to infinity |
| Detector | 25 mm high-performance infrared vidicon |
| Standard Lens | C-mount, 25 mm, f/1.4, manual iris |
| Gain Control | Selectable auto-gain and 4 fixed gain levels |
| Signal-to-Noise Ratio | 68 dB |
| Horizontal Resolution | Up to 700 TV lines |
| Video Output | RS-170 via BNC connector |
| Dimensions | 110.3 × 111.2 × 216.4 mm³ |
| Optional Accessory | Electronic viewfinder module |