Other Physical Property Test Instruments
Filter
Showing 691–720 of 993 results
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | TH520 |
| Testing Direction | Vertical |
| Maximum Test Height | 400 mm |
| Applicable Standards | ASTM E18, ISO 6508, JIS Z 2245 |
| Hardness Scales | HRA, HRB, HRC, HRD, HRF, HRG, HRH, HRR, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T |
| Load Application | Automatic motorized loading with dual-scale force system (major/minor loads) |
| Indenter Types | Diamond cone (120°, 0.2 mm tip radius) and hardened steel ball (1/16", 1/8", 1/4", 1/2") |
| Measurement Repeatability | ≤ ±0.5 HR under standardized conditions |
| Compliance | GLP-ready architecture with audit-trail-capable software interface |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | U918 |
| Compliance | DIN 50159-1:2008, ASTM A1038-2005, JB/T 9377-2010, JJG 654-2013, GB/T 34205-2017 |
| Calibration Modes | 10-point factory calibration, single-point elastic modulus compensation, multi-point direct hardness calibration (HRC, HRB, HRA, HB, HV5) |
| Display | 3.5″ color LCD with real-time statistics (min/max/avg/count/timestamp) |
| Indentation Size | <20 µm diameter (requires >200× optical magnification for visualization) |
| Measurement Time | ≤2 s per test |
| Battery | 3.6 V / 3000 mAh Li-ion, up to 15 h operation |
| Data Storage | 50 test sets + 10 calibration profiles |
| Connectivity | Bluetooth printer support (optional), USB-C PC data export |
| Test Orientation | Omnidirectional (±5° tolerance from perpendicular) |
| Hardness Scales | HV, HRC, HRA, HRB, HB (directly calibrated, no conversion tables required) |
| Brand | Ophir |
|---|---|
| Origin | Israel |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | Vega, Nova II, LaserStar, Nova, Orion, BeamTrack |
| Interface Options | USB, RS232, GPIB, Analog Output (1V/2V/5V/10V), Trigger I/O |
| Sampling Rates | Up to 250 kHz (Vega), 2 kHz (Nova II/LaserStar), 1.5 kHz (LaserStar), 10–30 Hz (Nova/Orion) |
| Data Storage | On-device real-time logging, PC-based active storage via USB |
| Software Support | Ophir StarLab v3.x, LabVIEW VIs, ActiveX Controls, FDA 21 CFR Part 11-compliant audit trail (optional), GLP/GMP-ready reporting |
| Detector Compatibility | Thermopile, Photodiode, Pyroelectric, RP (Radiation Pressure), BeamTrack (position & beam diameter) |
| Brand | Ortelli |
|---|---|
| Origin | Italy |
| Model | MVS2pro |
| Instrument Type | Buoyancy-Based Density Analyzer |
| Configuration | Benchtop Laboratory System |
| Sample Type | Solids (films, rods, granules) |
| Density Range | 0–2 g/cm³ |
| Temperature Control Range | 10–40 °C (standard test temp: 23 °C) |
| Cycle Time | ~3–5 min per sample |
| Auto-sampler Capacity | 16-position robotic arm |
| Compliance | ISO 1183-1, ISO 9001 |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | ANS800 Series |
| Max Operating Temperature | 800 °C or 1000 °C |
| Compliance | ASTM C336 |
| Temperature Control | PID-controlled, automated |
| Measurement Principle | LVDT-based fiber elongation monitoring under controlled cooling |
| Data Processing | Automated calculation of annealing point (AP) and strain point (SP) per ASTM C336 |
| Accuracy | ±1 °C (for glass fiber samples) |
| Software | Orton proprietary control & analysis suite with real-time plotting, statistical reporting, and audit-ready data logging |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OSA-type |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PCW-3000 |
| Pricing | Upon Request |
| Brand | Pharma Test |
|---|---|
| Origin | Germany |
| Model | PT-TD300 |
| Standards Compliance | USP <616> Method 1 & 2, EP <2.9.34>, DIN EN ISO 787-11, ASTM B527 |
| Sample Weight Input | Via Connected Balance (RS-232 or USB) |
| Density Calculation | Apparent Density, Tapped Density, Hausner Ratio, Carr Index |
| Output | Integrated Thermal Printer, USB Flash Drive Export (Methods & Reports) |
| Software Architecture | Standalone Embedded System with GLP-Compliant Audit Trail |
| Regulatory Alignment | Designed for GMP/GLP Laboratories, Supports 21 CFR Part 11 Readiness (User Authentication, Electronic Signatures Optional via Firmware Update) |
| Brand | Piezotest |
|---|---|
| Origin | Singapore |
| Model | PM200 |
| Price Range | USD 30,000–50,000 |
| d₃₃ Measurement Range | 0–10,000 pC/N |
| Resolution | 0.01 pC/N (lowest range) |
| Test Frequencies | 30–300 Hz (1 Hz step, calibrated at 110 Hz) |
| Static Force Range | 0–10 N |
| Dynamic Force Range | 0.05–0.5 N |
| Capacitance Range | 10 pF–0.1 µF |
| Loss Tangent (tanδ) Range | 0.0000–0.2000 |
| Max Sample Diameter | 136 mm |
| Max Sample Thickness (Polarization Direction) | 50 mm |
| Max Sample Mass | 1 kg |
| Compliance | ASTM D790, IEC 62047-18, ISO 20482 (referenced for piezoelectric characterization) |
| Brand | Piezotest |
|---|---|
| Origin | Singapore |
| Model | PM300 |
| d₃₃ Range | 0–10,000 pC/N |
| Resolution | 0.01 pC/N (lowest range) |
| Adjustable Static Force | 0–10 N |
| Dynamic Force | 0.05–0.5 N |
| Test Frequency | 30–300 Hz (1 Hz step, calibrated at 110 Hz) |
| Capacitance Measurement | 10 pF–0.1 µF |
| Loss Tangent (tan δ) | 0.0000–0.2000 |
| Max Sample Dimensions | Ø136 mm × 50 mm (polarization direction) |
| Max Sample Weight | 1 kg |
| Compliance | ASTM D790, IEC 62047-18, ISO 6722 (referenced for piezoelectric characterization) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PIG |
| Pricing | Available Upon Request |
| Coating Thickness Range | 2–2000 µm |
| Substrate Compatibility | Ferrous metals, non-magnetic metals, plastics, wood |
| Adhesion Test Standard Compliance | ASTM D3359, DIN 53151 |
| Indentation Hardness Test Standard Compliance | DIN EN ISO 2815 (Brinell-type) |
| Optical Inspection Capability | Integrated magnifier for defect assessment (pinholes, craters, cracks, bubbles, flaking, intercoat adhesion, substrate preparation quality) |
| Portability | Handheld, field-deployable with lab-grade repeatability |
| Dimensions | Ø50 mm × 27 mm |
| Brand | PerfectLight |
|---|---|
| Model | PL-TPV |
| Laser Source | Nd:YAG (1064/532/355 nm) |
| Pulse Width | 6–8 ns |
| Beam Spot Size | 4.5 mm |
| Max Pulse Energy | 330 mJ @ 1064 nm, 160 mJ @ 532 nm, 60 mJ @ 355 nm |
| Repetition Rate | ≤20 Hz |
| Preamplifier | 100 MΩ Input Impedance, 1 kΩ Output Impedance, 1 GHz Bandwidth |
| Digital Oscilloscope | 500 MHz Bandwidth, 4 Channels, 5 ns Rise Time |
| Energy Meter Range | 10 μJ – 150 mJ |
| Origin | Beijing, China |
| Compliance | Designed for GLP-compliant transient optoelectronic characterization |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | PM-240 |
| Dimensions (L×W×H) | 580 × 368 × 472 mm |
| Net Weight | 93 kg |
| Grinding Plate Diameter | 240 mm |
| Load Options | 27 kg, 47 kg, 69 kg, 102 kg |
| Calibration Weights | 0.9 kg, 1.75 kg, 1.75 kg, 2.92 kg |
| Power Supply | Single-phase, 220 V ±5%, 50 Hz |
| Motor Power | 0.55 kW |
| Motor Speed | 1440 rpm |
| Grinding Plate Speed | 855 rpm |
| Cycle Counter Display Range | 0–9 |
| Preset Cycles Range | 000–999 |
| Actual Cycles Display Range | 000–999 |
| Total Power Consumption | 0.555 kW |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | CPE1901 |
| Voltage Amplifier Output | >10 kV to 30 kV |
| Charge Range | 1 nC to >1 mC |
| Frequency Range | 0.01 Hz – 1 kHz (standard), up to 300 kHz (with optional HF module) |
| Built-in Amplifier | ±100 V or ±200 V |
| Hysteresis & Breakdown Modes | AC, DC, Field Endurance Life |
| Software Platform | LabVIEW-based with waveform control (sine, triangle, unipolar/bipolar, arbitrary) |
| Optional Modules | Piezoelectric Strain Measurement (10 nm resolution Fotonic Sensor or magnetoelectric sensor), High-Voltage Variable-Temperature Testing (–184 °C to +250 °C) |
| Compliance | Designed for ASTM D149, IEC 60243, IEEE Std 930, and ISO 25777 test protocols |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | CPT1706 |
| Voltage Range | ±4000 V |
| Current Range | ±20 mA |
| Frequency Range | 100 Hz – 1 MHz |
| Capacitance Range | 100 pF – 100 nF |
| Temperature Range | −184 °C to 250 °C |
| Optional Cryo-Free Chamber | −75 °C to 200 °C |
| Optional High-Temp Chamber | RT to 1000 °C |
| Optional Extended Frequency | 0.01 Hz – 110 MHz (dependent on integrated impedance analyzer) |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PK-CPR1901 |
| Pricing | Available Upon Request |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | PK-HT800 |
| Temperature Range | RT to 800 °C (up to 1000 °C optional) |
| Frequency Range | 20 Hz to 1 MHz (4-terminal shielded) |
| Dielectric Loss Tangent Sensitivity | < 0.1% |
| Sample Capacity | Up to 4 samples per thermal cycle |
| DC Bias Voltage | Up to 4000 V (optional) |
| Includes | High-temperature furnace, ceramic-insulated 4TP test fixture with spring-loaded Pt probes, Agilent/Keysight LCR meter interface (4284A, E4980AL, 4294A compatible), dedicated control software, and thermally rated cabling |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | PK-Pyro |
| Temperature Range | −184 °C to >300 °C (with liquid nitrogen cooling) |
| Current Measurement Sensitivity | down to 1 pA |
| Maximum Electric Field | >100 V/µm (air-gap configuration) |
| Sample Diameter | up to 8 cm |
| Electrode Configuration | spring-loaded spherical electrodes |
| Shielding | fully enclosed, grounded Faraday cage enclosure |
| Compliance | ASTM D257, ASTM D877, IEC 60243-1, ISO 60243-1 |
| Measurement Modes | pyroelectric current, leakage current, thermally stimulated depolarization current (TSDC) |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | PK-Pyro600 |
| Temperature Range | −184 °C to >300 °C (with liquid nitrogen cooling) |
| Current Measurement Resolution | pA-level (10⁻¹² A) |
| Sample Diameter | up to 8 cm |
| Electric Field Capability | >100 V/µm in air |
| High-Voltage Source | ±10 kV (SRS PS350 or Trek 10 kV) |
| Electrometer | Keithley 6517B (or equivalent) with coaxial shielded cabling |
| Shielding | Fully Faraday-shielded test chamber with insulated interior door mount |
| Electrode Configuration | Spring-loaded spherical electrodes for non-damaging contact on soft polymer films (<10 µm thick) |
| Compliance | ASTM D257, ISO 3001-1, IEC 60243-1, GLP/GMP-ready data logging architecture |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | CP |
| Voltage Range | Up to 10 kV |
| Electric Field Capability | ≥100 V/µm (up to 200 V/µm demonstrated) |
| Current Resolution | ≤1 pA |
| Temperature Range | –150 °C to >250 °C (with liquid nitrogen cooling) |
| Sample Diameter | up to 8 cm |
| Electrode Configuration | Spring-loaded spherical electrode for soft polymer films (<10 µm thick) |
| Shielding | Fully enclosed, grounded Faraday cage test chamber |
| Compliance | ASTM D257 (extended-field adaptation), ISO 60270 (partial discharge context), GLP-ready architecture |
| Brand | PolyK Technologies |
|---|---|
| Origin | USA |
| Model | ECE-22A |
| Temperature Range | −50 °C to 200 °C |
| Response Time | ≤100 ms |
| Sample Size | up to 20 mm × 20 mm |
| Heat Flux Sensor Sensitivity | >3 µV/(BTU·ft⁻²·hr⁻¹) |
| Thermal Resistance | 0.01 °F·ft²·hr/BTU |
| Thermal Capacitance | 0.02 BTU/(ft²·°F) |
| Data Acquisition | 16-bit ADC |
| Amplifier | Stanford Research Systems SR560 |
| Gain Range | 1–50,000 |
| Bandwidth | DC to 1 MHz |
| Input Noise | 4 nV/√Hz |
| Brand | Precision Eforming |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Precision Eforming |
| Pricing | Available Upon Request |
| Aperture Range | 3–2000 µm (1 µm increments) |
| Ultra-Precision Aperture Range | 2–500 µm (1 µm increments) |
| Base Material | Nickel |
| Compliance | ASTM E161, ISO 3310-3 |
| Tolerance | ±2 µm (Ultra-Precision: ±1.5 µm) |
| Aperture Shapes | Square, Round, Slotted, Custom Geometries |
| Sieve Diameters | 3", 8", 12" (stainless steel) |
| Support Grid | Stainless steel (optional or removable) |
| Brand | PrimeNano |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Scanwave Scanning Microwave Impedance Microscope |
| Pricing | Available Upon Request |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DMA-135D |
| Instrument Type | Portable Oscillating U-Tube Densimeter |
| Sample Type | Liquids |
| Density Range | 0.001–1.999 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Temperature Range | 0–50 °C |
| Repeatability | ±0.01 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Minimum Sample Volume | 10 mL |
| Compliance Standards | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PDM-301A |
| Instrument Type | Laboratory Benchtop Digital Densimeter |
| Measurement Principle | Oscillating U-Tube Method |
| Sample Type | Liquids Only |
| Density Range | 0.0000–3.0000 g/cm³ |
| Density Resolution | ±0.0001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Temperature Control Range | 15–30 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 10 mL |
| Compliance | ASTM D4052, ASTM D5002, ASTM D3505, ISO 12185, GB/T 29617, GB/T 2013, SH/T 0604, SN/T 2383, DB/T 1231, JJG 1058 |
| Brand | PULUODY |
|---|---|
| Model | PLD-1884B |
| Temperature Control Range | 5–80 °C |
| Temperature Stability | ±0.2 °C |
| Heating Power | 600 W |
| Input Power | <1000 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Construction | Stainless Steel Bath with Optical Clarity |
| Cooling System | Imported Hermetic Compressor |
| Circulation | Magnetic Drive Circulating Pump |
| Compliance | GB/T 1884, ASTM D1298, ISO 3675 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PLD-1885A |
| Instrument Type | True Density Calculator |
| Form Factor | Portable |
| Sample Type | Liquid |
| Density Measurement Range | 0.0005 g/mL |
| Density Accuracy | ±0.0005 g/mL |
| Compliance Standard | GB/T 1885–1998 “Petroleum Measurement Tables” |
| Application Scope | Crude oil, gasoline, diesel, lubricating oils, water content (mₛ) and net oil mass (m꜀) calculation |
| Temperature Range | –55 °C to +50 °C |
| Power Supply | Rechargeable battery or 220 V AC adapter |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PVM Test Fixtures |
| Pricing | Available Upon Request |
| Density measurement range | 0–1.999 g/cm³ |
|---|---|
| Density accuracy | ±0.001 g/cm³ |
| Alcohol concentration range | 0–100% (v/v) |
| Alcohol accuracy | ±0.5% (v/v) |
| Temperature control | 20 °C ±0.1 °C |
| Sample volume per measurement | 2 mL |
| Data storage capacity | 80 entries |
| Power supply | 220 V ±22 V, 50 Hz ±1 Hz, 50 VA |
| Operating ambient temperature | 5–35 °C |
| Net weight | 2 kg |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q10 CHD MASTER/Plus |
| Instrument Type | Microhardness Tester |
| Control System | Electromechanical closed-loop sensor actuation |
| Turret | 6-position motorized turret |
| Operating Concept | 3D intuitive human-machine interface |
| Test Automation | Fully programmable sequence-based testing with adaptive dwell-time termination |
| Data Output | Configurable report templates with embedded hardness conversion algorithms |
| Image Quality | High-resolution optical imaging system with LED illumination and digital autofocus capability |
| Testing Space | Large X-Y-Z travel range (X: 200 mm, Y: 200 mm, Z: 150 mm) |
| Connectivity | Ethernet, USB 3.0, RS-232, optional integration with LIMS and MES systems |