Other Physical Property Test Instruments
Filter
Showing 751–780 of 1035 results
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PVM Test Fixtures |
| Pricing | Available Upon Request |
| Density measurement range | 0–1.999 g/cm³ |
|---|---|
| Density accuracy | ±0.001 g/cm³ |
| Alcohol concentration range | 0–100% (v/v) |
| Alcohol accuracy | ±0.5% (v/v) |
| Temperature control | 20 °C ±0.1 °C |
| Sample volume per measurement | 2 mL |
| Data storage capacity | 80 entries |
| Power supply | 220 V ±22 V, 50 Hz ±1 Hz, 50 VA |
| Operating ambient temperature | 5–35 °C |
| Net weight | 2 kg |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q10 CHD MASTER/Plus |
| Instrument Type | Microhardness Tester |
| Control System | Electromechanical closed-loop sensor actuation |
| Turret | 6-position motorized turret |
| Operating Concept | 3D intuitive human-machine interface |
| Test Automation | Fully programmable sequence-based testing with adaptive dwell-time termination |
| Data Output | Configurable report templates with embedded hardness conversion algorithms |
| Image Quality | High-resolution optical imaging system with LED illumination and digital autofocus capability |
| Testing Space | Large X-Y-Z travel range (X: 200 mm, Y: 200 mm, Z: 150 mm) |
| Connectivity | Ethernet, USB 3.0, RS-232, optional integration with LIMS and MES systems |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 A/A+ |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 187 mm / 180 mm (extendable to 377 mm) |
| Maximum Specimen Weight | 50 kg |
| Motorized Cross-Table Dimensions | 170 × 250 mm |
| Height Adjustment Speed | up to 6 mm/s |
| Power Supply | 230 V~1/N/PE or 110 V~1/N/PE |
| Max. Power Consumption | ~240 W |
| Host Weight | 120 kg (137 kg with height extension) |
| Interface | 3× USB |
| Software | Qpix Control2 |
| Optional Features | Dual high-resolution camera system (up to 2×), panoramic camera (A+ only), motorized anvil/cross-table, Jominy fixture, multi-specimen holders, interchangeable indenters and objectives |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 CS ECO |
| Instrument Type | Rockwell Hardness Tester |
| Force Range | 1–250 kg (9.81–2452 N) |
| Test Height | 250 mm |
| Throat Depth | 157 mm |
| Maximum Specimen Weight | 100 kg |
| Machine Weight | 77 kg |
| Display | 7-inch capacitive color touchscreen |
| Force Application | Electromechanical, fully automated |
| Power Supply | 100–240 V AC, 45–65 Hz, ~60 W |
| Compliance | ASTM E18, ISO 6508, DIN 50103, GB/T 230.2 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 R |
| Instrument Type | Rockwell Hardness Tester |
| Test Force Range | 1–250 kg (9.81–2450 N) |
| Test Height / Throat Depth | 260 mm / 180 mm |
| Extended Test Height (Optional) | 450 mm |
| Vertical Adjustment Speed | up to 6 mm/s |
| Anvil/Cross Table Dimensions | 250 × 260 mm |
| Data Interfaces | 3× USB, 1× Ethernet, 1× RS232 |
| Unit Weight | 95 kg (112 kg with height extension) |
| Max. Specimen Weight | 100 kg |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~240 W |
| Software | Qpix T2R |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 150 RCS |
| Hardness Test Method | Rockwell C Scale (HRC) |
| Maximum Test Force | 150 kgf (1471.5 N) |
| Dual Force Range Capability | 62.5 kgf (613.1 N) and 150 kgf (1471.5 N) |
| Test Height Adjustment Range | 180 mm |
| Horizontal Test Space | 180 mm |
| Anvil Diameter | Ø100 mm |
| Machine Weight | 120 kg |
| Interface | 1 × RS232-C, 1 × RJ45 (Ethernet) |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~360 W |
| Control System | Siemens S7 PLC with 4" Touchscreen HMI |
| Cycle Time | <3 s per test |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 200 CS |
| Instrument Type | Brinell-Vickers-Rockwell Combined Hardness Tester |
| Test Force Range | 0.5 – 187.5 kgf (4.9 – 1839 N) |
| Test Space | 250 mm (height) × 238 mm (throat depth) |
| Turret Positions | 5 |
| Imaging System | 5 MP industrial camera with Ethernet interface |
| Objective Lenses | XLED 2×, XLED 5×, 5×, 10×, 20×, 50×, 100× |
| Field of View | 0.113 × 0.084 mm (at 100×) to 4.24 × 3.18 mm (at XLED 2×) |
| Stage Diameter | Ø100 mm |
| Height Adjustment | Manual lead-screw drive |
| Operating System | Windows 10 IoT |
| Storage | 128 GB SSD |
| Interfaces | 1× front USB, 4× rear USB, 2× RJ45 Ethernet, 1× DisplayPort |
| Weight | 132 kg |
| Compliance | ASTM E10, E92, E18 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 / 750 / 3000 CS/C EVO |
| Test Force Range | QNESS 250 CS: 1–250 kg (9.81–2450 N) |
| QNESS 750 CS | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 CS | 0.3–3000 kg (2.94–29430 N) |
| QNESS 250 C | 1–250 kg (9.81–2450 N) |
| QNESS 750 C | 0.3–750 kg (2.94–7358 N) |
| QNESS 3000 C | 0.3–3000 kg (2.94–29430 N) |
| Test Height | C version: 395 mm |
| CS version | 175 mm |
| Throat Depth | 220 mm |
| Anvil Diameter | Ø100 mm |
| Turret Configuration | 2-position standard or 8-position optional |
| Imaging System | 5 MP industrial Ethernet camera, up to 270 FPS |
| Objective Lenses | XLED 1, XLED 2, XLED 5, 5×, 10×, 20×, 50×, 100× |
| Field of View | 0.113 × 0.084 mm (at 100×) to 7.98 × 5.97 mm (at XLED 1) |
| Display | 12″ capacitive touchscreen |
| Operating System | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max. Power Consumption | ~480 W |
| Weight | QNESS 250/750 CS: 250 kg |
| QNESS 3000 CS & all C versions | 300 kg |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 E EVO / QNESS 750 E EVO / QNESS 3000 E EVO |
| Test Force Range | QNESS 250 E EVO: 1–250 kgf (9.81–2450 N) |
| QNESS 750 E EVO | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 E | 0.3–3000 kgf (2.94–29,430 N) |
| Maximum Test Height | 510 mm |
| Throat Depth | 320 mm |
| Anvil Dimensions | 584 × 450 mm |
| Weight Capacity | ≤ 3500 kg |
| Turret Configuration | 2-position standard or 8-position optional |
| Imaging System | 5 MP industrial camera, Ethernet interface, up to 270 fps |
| Optical Magnification | XLED 1 to 100× (FOV: 0.113 × 0.084 mm at 100× up to 7.98 × 5.97 mm at XLED 1) |
| Control Interface | 12″ capacitive touchscreen |
| Operating System | Windows 10 IoT Enterprise |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max. Power Consumption | ~1230 W |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 M EVO / QNESS 750 M EVO / QNESS 3000 M EVO |
| Testing Force Range | QNESS 250 M EVO: 1–250 kgf (9.81–2450 N) |
| QNESS 750 M EVO | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 M EVO | 0.3–3000 kgf (2.94–29430 N) |
| Max Test Height | 510 mm |
| Throat Depth | 320 mm |
| Anvil Dimensions | 584 × 450 mm |
| Weight | 490 kg |
| Imaging | 5 MP industrial Ethernet camera, up to 270 fps |
| Turret | 2-position standard or 8-position optional |
| Software | Qpix T2 (optional Qpix CONTROL 2 M) |
| OS | Windows 10 IoT |
| Storage | 128 GB SSD |
| Power Supply | 230 V ~1/N/PE or 110 V ~1/N/PE |
| Max Power Consumption | ~480 W |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 / 750 CA/CA+ EVO |
| Test Force Range | QNESS 250 CA EVO: 1–250 kg (9.81–2450 N) |
| QNESS 750 CA EVO | 0.3–750 kg (2.94–7358 N) |
| Test Height / Throat Depth | 250 / 220 mm |
| XY Motorized Stage Travel | X 260 mm / Y 266 mm |
| Max. Specimen Weight | 100 kg |
| Host Weight | 320 kg |
| Power Supply | 110–230 V~, 50–60 Hz, 1/N/PE |
| Max. Power Consumption | ~480 W |
| Software | Qpix Control2 |
| Camera | 5 MP Panoramic Imaging (CA+ only) |
| Supported Hardness Methods | Brinell, Vickers, Rockwell, Knoop, Polymer, Carbon Brush Testing |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS 250 A/A+, QNESS 750 A/A+, QNESS 3000 A/A+ EVO |
| Test Force Range | QNESS 250 A/A+: 1–250 kgf (9.81–2450 N) |
| QNESS 750 A/A+ | 0.3–750 kgf (2.94–7358 N) |
| QNESS 3000 A/A+ | 0.3–3000 kgf (2.94–29430 N) |
| Test Height Adjustment | Motorized asynchronous Z-axis, up to 3200 kg clamping force |
| Throat Depth / Max Vertical Clearance | 362 mm / 320 mm |
| XY Stage Travel | X 460 mm × Y 350 mm |
| Stage Size | 450 × 297 mm (motorized cross-slide) |
| Imaging System | 5 MP panoramic camera (A+ models only) |
| Software | Qpix Control2 with 3D UI, Ethernet interface (RJ45) |
| Compliance | Designed for ASTM E10, E18, E92, E384, ISO 6506, ISO 6507, ISO 6508, ISO 20422, and EN ISO 1463 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 250/750/3000 EVO |
| Instrument Type | Universal Hardness Tester |
| Load Range (Q250) | 1–250 kgf (9.8–2450 N) |
| Load Range (Q750) | 0.3–750 kgf (2.94–7358 N) |
| Load Range (Q3000) | 0.3–3000 kgf (2.94–29430 N) |
| Test Height | 175–510 mm |
| Throat Depth | 220–320 mm |
| Max Specimen Weight | ≤3500 kg |
| Imaging System | 5 MP CMOS camera with Ethernet interface |
| Display | 12″ capacitive touchscreen |
| Loading Control | Electromechanical, closed-loop force feedback |
| Illumination | XLED optical module for Brinell impression analysis |
| Turret | Manual 2-position or optional motorized 8-position auto-turret |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 60 A/A+ EVO |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.25 g – 62.5 kgf |
| Indenter | ASTM- and DAkkS-certified Vickers diamond |
| Turret | 8-position motorized |
| Illumination | White LED with electric iris shutter |
| Software | Qpix Control2 with intuitive 3D control interface |
| Positioning System | Direct-read linear encoders on X/Y/Z axes (0.5 µm resolution) |
| Optional Feature (A+ only) | Panoramic camera with automated image acquisition (49 × 37 mm field of view) |
| Microstructural Analysis Module | INSPECT (modularly licensable) |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Qness 60 M EVO |
| Instrument Type | Microhardness Tester |
| Test Force Range | 0.00245 N – 613.1 N (0.25 g – 62.5 kg) |
| Test Space (Height/Throat Depth) | 145 mm / 170 mm |
| Stage Options | Manual Cross-Slide XY Stage (135 × 135 mm) or Standard Ø100 mm Anvil |
| X/Y Travel | 150 mm × 150 mm |
| Z-Travel | 145 mm |
| Max. Specimen Weight | 50 kg |
| Host Weight | 55 kg |
| Power Supply | 100–240 V, ~1/N/P, 45–65 Hz |
| Software | Qpix Control2 M with INSPECT metallographic analysis module |
| Test Methods Supported | Vickers, Knoop, Brinell |
| Turret | 8-position motorized, configurable with up to 3 hardness modules and 6 objective lenses |
| Illumination | White LED with motorized iris shutter |
| Imaging | High-resolution color camera integrated into optical path |
| Compliance | ASTM E384, ISO 6507, ISO 6508, EN ISO 14978, DAkkS-accredited Vickers diamond indenter included |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | QNESS CHD MASTER+ |
| Hardness Testing Methods | Vickers, Knoop, Brinell |
| Test Load Range | 0.49 – 98.1 N (50 g – 10 kgf) |
| Turret | 6-position, motorized |
| X/Y/Z Travel | 150 × 150 × 145 mm |
| Specimen Weight Capacity | ≤ 50 kg |
| Host Weight | 58 kg |
| Camera System | 5 MP color CMOS |
| Positioning Repeatability | ±3.5 µm |
| Interface | 1× USB 3.0 (hardness tester–PC), optional QDAS/PCI/AMS/REMOTE modules |
| Power Supply | 230 V ~ 1/N/PE or 110 V ~ 1/N/PE |
| Max. Power Consumption | ~200 W |
| Objective Lenses | 4×, 20×, 40× |
| Certified Vickers Indenters | DakkS-accredited |
| Sample Holders | CHD Master+: single-position (Ø30/40/50 mm), quad-position (Ø30/40/50 mm), octo-position (Ø30/40 mm) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | QBJ |
| Pricing | Available Upon Request |
| Punch Diameter | 20 mm |
| Maximum Indentation Depth | 10 mm |
| Indentation Resolution | 0.05 mm |
| Digital Depth Display | 0.01 mm resolution |
| Specimen Size | 70 mm × 70 mm |
| Specimen Thickness Range | 0.30–1.25 mm |
| Substrate Material | Polished Steel Plate per GB/T 9271 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | QHZ |
| Pricing | Upon Request |
| Standards | GB/T 9279–1988, ISO 1518:1973, ISO 1518–1997 |
| Scratch Length | ≥60 mm |
| Traverse Speed | 30–40 mm/s |
| Indenter | 1 mm diameter hardened steel ball |
| Load Range | 0–2000 g |
| Dimensions (L×W×H) | 300 × 200 × 300 mm |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QJICHL |
| Price Range | USD 1,400 – 7,200 |
| Test Stations | 5 (simultaneous control & display) |
| Adjustable Roller Cycles | 0–200 cycles |
| Cycle Frequency | 0.5 Hz |
| Applied Load | 8 N (standard) |
| optional weights | 3 N, 5 N, 7 N |
| Power Supply | AC 220 V |
| Dimensions (L×W×H) | 500 × 400 × 400 mm |
| Weight | 12 kg |
| Roller Initial Position & Height | Manually adjustable |
| Dual Support Plates | One movable plate on roller side |
| Brand | QJICHL |
|---|---|
| Origin | Shanghai, China |
| Model | QJICHL- |
| Compliance | ISO/IEC 10373-3:2001 |
| Test Load Range | 3 N, 5 N, 7 N, 8 N (adjustable via calibrated weights) |
| Cycle Count Range | 0–200 cycles (programmable) |
| Cycle Frequency | 0.5 Hz ±0.05 Hz |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 500 × 400 × 400 mm |
| Weight | 12 kg |
| Test Stations | 5 independent, simultaneously controlled and monitored |
| Roller Initial Position & Height | Manually adjustable |
| Roller Support Configuration | Dual-side support plates |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | QMB |
| Pricing | Available Upon Request |
| Gradient Plate Temperature Range | 0 °C to +45 °C |
| Number of Temperature Measurement Points | 10 |
| Temperature Measurement Accuracy | ±0.2 °C |
| Gradient Interval | 5 °C ±1 °C |
| Temperature Readout | Digital Display |
| Compliant Standards | GB/T 9267, ISO 2115:1976 |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q10 / Q30 / Q60M Semi-Automatic Vickers Hardness Tester |
| Automation Level | Semi-Automatic with Motorized Turret and Auto-Focus |
| Turret Positions | 6-position motorized turret |
| Display | 12″ industrial touchscreen IPC |
| Software | Qpix Control v5.x with GLP-compliant audit trail |
| Data Export | CSV, PDF, Excel-compatible reports |
| Compliance | ASTM E384, ISO 6507-1, EN ISO 1463, USP <1054> (for hardness validation workflows) |
| Safety | User-level access control (3-tier permission system) |
| Sample Stage | Motorized X-Y-Z stage with dynamic Z-height compensation |
| Imaging | Integrated high-resolution monochrome CMOS camera, 2× optical zoom per objective, real-time edge detection and indentation recognition |
| Brand | QATM |
|---|---|
| Origin | Austria |
| Model | Q 150 A |
| Test Methods | Rockwell (A/A+), Knoop, Brinell |
| Load Range | 1–250 kgf (9.81–2450 N) |
| Max Specimen Height/Throat Depth | 187 mm / 180 mm |
| Max Specimen Weight | 50 kg |
| Stage | Motorized X-Y Translation Stage |
| Height Adjustment | Manual Knob-Driven Dynamic Z-Axis with Collision Avoidance |
| Optional Imaging | Panoramic Camera (Q150 A+ only) |
| Illumination | High-Contrast LED Coaxial Lighting |
| Compliance | ASTM E18, ASTM E384, ASTM E10, ISO 6508, ISO 6507, ISO 6506, EN ISO 1463, DIN 50103 |
| Software | Qpix Control v5.x with Audit Trail, User Management & CFR 21 Part 11 Readiness |
| Brand | QATM |
|---|---|
| Country of Origin | Austria |
| Model | Q150 R / Q150 A / Q150 A+ |
| Hardness Scales | Rockwell (R), Brinell (B), Vickers (HV), Knoop (HK) |
| Automation Levels | Manual (R), Semi-Automatic & Fully Automatic (A), Fully Automatic with Integrated Panoramic Imaging (A+) |
| Test Force Range | 1–3000 kgf (A/A+ models) |
| Sample Height Clearance | Up to 280 mm |
| Max. Sample Weight | 50 kg |
| Interface Options | RS232, Ethernet, USB |
| Compliance | CE, ISO 6508 (Rockwell), ISO 6506 (Brinell), ISO 6507 (Vickers), ISO 4545 (Knoop), ASTM E18, E10, E384, E92 |
| Software | Qpix T2R v5.x (GLP-compliant data logging, audit trail, user access levels, report export to PDF/CSV/XLSX) |
| Brand | QATM (Qness) |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Qradial |
| Instrument Type | Universal Hardness Tester |
| Price | USD 135,000 (approx.) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GW |
| Pricing | Available Upon Request |
| Compliance | ISO 2409:1974, GB/T 9286–1998 |
| Blade Spacing Options | 1 mm and 2 mm |
| Recommended Film Thickness Range | ≤60 µm (1 mm blade), 60–100 µm (2 mm blade) |
| Test Environment | 23 °C ± 2 °C, 50 % RH ± 5 % |
| Blade Configuration | Quadruple-edge replaceable cutting head with ship-shaped nut and thrust screw adjustment |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China-made) |
| Model | QT-I |
| Quotation | Available upon request |
| Drive Motor | 36BF02B stepper motor |
| Spherical Tip Diameter | 8 mm |
| Rotational Speed Options | 0.5, 1, 2, 6, 12, 24 h/rev |
| Applied Load | 12 g |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 140 × 140 × 156 mm |
| Test Trajectory Diameter | 80 mm |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | NexGen 160 / NexGen 250 / ATL 160XL / ATP30 |
| Liquidation Rate | ≥25 L/day (NexGen 160 & 250), ≥35 L/day (ATL 160XL) |
| Dewar Capacity | 160 L (NexGen 160, ATL 160XL), 250 L (NexGen 250) |
| Helium Purity Requirement | 99.999% (feed gas), 99.9995% (post-ATP30 purification) |
| Purification Capacity | 30 L/min (ATP30, typical) |
| Regeneration Time | 5 h (filterless, fully automated) |
| System Dimensions (L×W×H) | 104×71×152 cm (NexGen 160), 114×81×160 cm (NexGen 250), 104×76×151 cm (ATL 160XL), 60×69×148 cm (ATP30) |
| Compressor Type | Water-cooled (VFD option available) |
| Power Input | 6.5–7.5 kW, 110 V or 380 V AC |
| Operating Pressure | 1 psig (liquefaction stage) |
| Safety Architecture | Multi-stage fault-tolerant interlocks, helium containment integrity monitoring, real-time pressure/temperature/flow diagnostics |
| Brand | Quantum Design |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | PPMS DynaCool |
| Pricing | Upon Request |