Other Physical Property Test Instruments
Filter
Showing 841–870 of 1035 results
| Brand | SPL |
|---|---|
| Model | SPL-PM-IR |
| Spectral Range | 200–1700 nm |
| Detector Types | UV-enhanced Si, Si, InGaAs |
| Calibration Data Storage | Integrated EEPROM |
| Interface | Digital (SPL-PM series compatible) |
| Attenuation Options | 10×, 100×, 1000× ND filters |
| Origin | Zhejiang, China |
| Distribution Type | Authorized Distributor |
| Brand | AMAE |
|---|---|
| Model | MI-101 |
| Origin | Guangdong, China |
| Instrument Type | Tamping Rod for Flow Moisture Point (FMP) and Transportable Moisture Limit (TML) Testing |
| Compliance | IMSBC Code Annex 1, Section 4.2 (Proctor–Fagerberg Method) |
| Application | Solid Bulk Cargo Stability Assessment |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPS-211Lx |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer | JEL GmbH |
| Type | STAV II |
| Power Supply | 230 V AC, 50 Hz |
| Vibration Frequency | 250 ± 15 cycles/min |
| Vibration Amplitude | 3.0 ± 0.1 mm |
| Available Cylinder Volumes | 50, 100, 250, 500, 1000 mL (DIN 53194 compliant) |
| Net Weight | 9 kg |
| Control Interface | Red illuminated panel with integrated counter (5-digit, programmable), conical locking mechanism for cylinder fixation, low-noise AC motor |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-160 |
| Hardness Test Method | Rockwell, Ball Indentation (HBT), Vickers Hardness (HVT) |
| Load Range (Major Load) | 1–250 kgf (9.8–2450 N) |
| Test Anvil | Ø80 mm, Removable |
| Max Specimen Height | 300 mm |
| Max Specimen Depth | 200 mm |
| Display | 7-inch Touchscreen Interface |
| Illumination | LED at Indentation Zone |
| Optional Feature | Motorized Z-axis (Duramin-160 Z) |
| Compliance | ASTM E18, ISO 6508, EN ISO 6508, JIS Z 2245 |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-3000 |
| Hardness Test Method | Brinell |
| Load Range | 62.5–3000 kgf (612.9–29400 N) |
| Maximum Specimen Height | 190 mm |
| Maximum Specimen Depth | 220 mm |
| Indentation Evaluation | Handheld Zoom Camera with Auto-Measurement |
| Control System | Embedded PC with Touchscreen & Mouse Interface |
| Compliance | ASTM E10, ISO 6506-1, EN ISO 6506-1 |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-4 |
| Instrument Type | Microhardness Tester |
| Load Ranges | 0.0098–19.6 N (10 gf–2 kgf) and 9.81–613.1 N (1 kgf–62.5 kgf) |
| Test Height Range | 0–200 mm (M1), 0–400 mm (M2) |
| Measurement Method | Eyepiece-based manual indentation evaluation |
| Turret | Motorized 6-position |
| Stage | Manual XY stage (90 mm × 90 mm travel, 25 mm × 25 mm scratch area), manual Z-axis with micrometer adjustment |
| Display | 8-inch touchscreen interface |
| Compliance | Designed to meet ASTM E384, ISO 6507-1, ISO 6506-1, and EN ISO 2039-1 requirements for micro- and macro-hardness testing |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-600 |
| Load Ranges | 1–250 kgf |
| Test Methods | Vickers, Knoop, Brinell, Rockwell |
| Automation Level | Semi-automatic with motorized 6-position turret |
| Z-axis Options | Manual (M) or Motorized (Z) |
| Max Specimen Height | 330 mm |
| Max Specimen Depth | 260 mm |
| Display | 15-inch color touchscreen |
| Force Measurement | Load cell-based |
| Illumination | Ring light with dark-field mode |
| Software Interface | Integrated embedded PC with touch/mouse operation |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | Duramin-650 |
| Load Ranges | 1–250 kgf, 3–750 kgf, 5–3000 kgf |
| Test Methods | Vickers, Knoop, Brinell, Rockwell |
| Automation Level | Semi-Automatic & Fully Automatic |
| Max Specimen Height | 300 mm |
| Max Specimen Depth | 220 mm |
| Control Interface | 15″ Color LCD Touchscreen |
| Load Cell Technology | Yes |
| Motorized Indenter | Yes |
| Motorized XY Stage (AC variants) | 390 × 262 mm travel, 250 × 160 mm scratch area |
| Turret | 6-position (M) or 8-position (AC) motorized |
| Optical System | Panoramic overview camera + laser positioning + auto-focus + auto-illumination |
| Compliance | ASTM E384, ASTM E10, ASTM E18, ISO 6507, ISO 6506, ISO 6508, ISO 2039 |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | DuraVersa-100 |
| Instrument Type | Universal Hardness Tester |
| Load Range Options | 200 gf–250 kgf |
| Test Methods | Vickers, Knoop, Brinell, Rockwell |
| Turret | Motorized 9-position |
| Automation Features | Motorized Z-axis with auto-focus, motorized XY-stage (optional), anti-collision system, panoramic camera, embedded PC with touch interface |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | DuraVigo-150 |
| Hardness Test Method | Rockwell & Superficial Rockwell |
| Load Range | 3–250 kgf (29.4–2452.5 N) |
| Frame Type | C-frame with reinforced steel construction |
| Depth Measurement System | Direct sub-micron axial displacement sensor |
| Display | 6.5-inch capacitive color touchscreen |
| Interface | USB port for data export |
| Compliance | ISO 6508-1, ASTM E18, EN ISO 2039-2 |
| Software Features | Statistical analysis, hardness conversion tables, upper/lower limit visualization (green/red), surface correction, GLP-compliant audit trail |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | DuraVista-40 |
| Hardness Test Methods | Vickers, Knoop, Brinell |
| Load Range | 0.1 gf to 62.5 kgf |
| Automation Level | Semi-Automatic and Fully Automatic Micro/Macro Testing |
| Software | DuraSoft PC Control Software |
| Display | 27" Full-HD Touchscreen |
| Turret | Motorized 6-Position |
| Stage | Manual and Motorized XY Stage Options |
| Z-Axis | Motorized with Auto-Focus and Collision Protection |
| Camera | 18 MP High-Resolution Measurement Camera |
| Optional | Panoramic Camera Module |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SUNPLUS |
| Type | Film Gel Defect Analyzer (Fish Eye Measurement System) |
| Application | Polypropylene (PP) Cast & Biaxially Oriented Films |
| Measurement Principle | Optical Projection + Standard Aperture Masking |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SP-Y-1700-B |
| Pricing | Available Upon Request |
| Measuring Thresholds | 0.2 mm, 0.4 mm, 0.8 mm |
| Detection Area | ≥200 × 200 mm |
| Illuminance | ≥2000 lm |
| Light Source | 24 V / 250 W Halogen Lamp |
| Power Supply | 220 V, 50 Hz |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SP-Y-1908 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SP-Y-600 |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIKE3 |
| Pricing | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SZQ |
| Pricing | Available Upon Request |
| Wet Film Thickness Range | 25–500 µm |
| Thickness Accuracy | ±2 to ±10 µm (dependent on model) |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | AHT |
| Application | Continuous Shore A Hardness Testing of Vulcanized Rubber |
| Sample Capacity | 20-position (upgradable to 30) automated sample carousel |
| Control | Fully software-driven test setup, data acquisition, and pass/fail evaluation |
| Compliance | ASTM D2240, ISO 7619-1, DIN 53505 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TAM IV+Biologic |
| Pricing | Available Upon Request |
| Brand | R&P |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Talliani Vacuum Stability Analyzer |
| Pricing | Upon Request |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 108 |
| Instrument Type | Digital Food Thermometer |
| IP Rating | IP67 (with Softcase) |
| Thermocouple Compatibility | Type K and Type T |
| Measurement Range | –50 to +300 °C (both types) |
| Accuracy | ±0.5 °C (–30 to +70 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₀) | ≤10 s in moving liquid |
| Display | Single-line LCD, large-digit |
| Operating Temperature | –20 to +60 °C |
| Storage Temperature | –30 to +70 °C |
| Weight | 154 g (instrument + battery), 210 g (incl. Softcase) |
| Dimensions | 140 × 60 × 24 mm |
| Housing Material | ABS / ABS-PC with 10% glass fiber |
| Power Supply | 3 × AAA rechargeable batteries |
| Battery Life | up to 2500 h at 23 °C |
| Compliance | EN 13485, HACCP principles, EU EMC Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Model | 0572 6560 |
| Sensor Type | Integrated NTC temperature sensor + capacitive humidity sensor |
| Measurement Range | -20 to +70 °C, 0–100 %RH |
| Accuracy | ±0.5 °C (-20 to +70 °C) ±1 digit |
| Resolution | 0.1 °C, 0.1 %RH |
| Data Storage Capacity | 16,000 readings |
| Logging Interval | 1 min to 24 h (user-selectable) |
| Operating Temperature | -20 to +70 °C |
| Storage Temperature | -40 to +70 °C |
| Protection Class | IP20 |
| Power Supply | Included battery (CR2450) |
| Interface | USB |
| Software Compatibility | Windows XP, Vista, Windows 7 |
| Compliance | CE, RoHS |
| Data Retention | Non-volatile memory — data preserved even after battery depletion |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 6082 |
| Instrument Type | Thermo-Hygrometer |
| Category | Physical Property Testing Instruments – Other |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6352 |
| Instrument Type | Thermo-Hygrometer |
| Key Measurement Capabilities | Relative Humidity, Air Temperature, Surface Temperature, Center Temperature, Absolute Pressure, Pressure Dew Point, Calculated Dew Point, Dew Point Difference, Moisture Content (via probe), U-value (via optional calculation module) |
| Display | Backlit LCD with Max/Min/Avg Logging |
| Data Storage | Up to 10,000 readings |
| Interface | USB (PC connectivity), Optional IR Printer Support |
| Enclosure | ABS/TPE/Metal |
| Weight | 428 g |
| Dimensions | 220 × 74 × 46 mm |
| Operating Temperature | −20 °C to +50 °C |
| Battery | Alkaline, ~200 h lifetime |
| Storage Temperature | −30 °C to +70 °C |
| Brand | The Great Wall |
|---|---|
| Origin | Shanghai, China |
| Model | 272-1 Metal-Cased |
| Instrument Type | Psychrometer (Wet-and-Dry Bulb Thermometer) |
| Category | Thermo-Hygrometer |
| Manufacturing Status | Domestic Production |
| Distributor Type | General Distributor |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Oscillating U-tube Densimeter (Note: Correction — actual principle is gamma-ray transmission, not oscillating tube |
| Instrument Category | Benchtop Laboratory / Industrial In-Line Density Meter |
| Detection Method | Non-contact Gamma-Ray Transmission Densitometry |
| Radiation Sources | Cs-137 or Co-60 |
| Density Measurement Principle | Attenuation-based gamma-ray transmission through process media |
| Temperature Operating Range | –40 °C to +75 °C |
| Environmental Rating | NEMA 4X / IP65 |
| Detector Configuration | Integrated or Remote (Split) |
| Multiplexing Capability | Up to 4 independent measurement channels per microprocessor unit |
| Analog I/O | 4 × 4–20 mA inputs, 2 × 4–20 mA outputs, 2 × 0–10 V inputs, 2 digital inputs, 2 relay outputs |
| Communication Interfaces | RS232 / RS485, 10/100 M Ethernet with ESD protection, USB |
| Power Supply | 115/230 V AC ±10%, 50/60 Hz or 24 V DC |
| Certified Compliance | IEC 60068-2-6 (sinusoidal vibration), IEC 60068-2-64 (random vibration), IEC 60068-2-27 (shock), IEC 60068-2-38 (temp/humidity cycling) |
| Radiation Safety | Lead-shielded source housing |
| activity range | 1–10,000 mCi (Cs-137) or 1,000–3,000 mCi (Co-60) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | FD910, FD950, FD960, FD900, ID900, PD900 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop & In-line Process |
| Application Focus | Petroleum, Petrochemical, Chemical, LNG, and Power Generation |
| Density Range (Liquid) | 0–2100 kg/m³ |
| Density Range (Gas) | 0–1000 kg/m³ (FD900/ID900), 0–250 kg/m³ (PD900) |
| Accuracy (Liquid) | ±0.1 kg/m³ |
| Repeatability (Liquid) | 0.02 kg/m³ |
| Temperature Compensation | Integrated 4-wire PT100 (1/3 DIN) |
| Operating Temp (Liquid) | −50°C to +180°C |
| Operating Temp (Gas) | −200°C to +200°C |
| Pressure Rating | Up to 170 bar (FD900), 150 bar (ID900), 100–150 bar (PD900) |
| Enclosure Rating | IP65 / NEMA 4X |
| Hazardous Area Certifications | ATEX Ex ia IIC T4/T6, CSA Class I Div 1 Groups B, C, D, IECEx, NACE MR0175/ISO 15156 compliant |
| Output Options | 4–20 mA + HART (HME900), Frequency/Modulated Current (CM515), Dual-Channel PT100 |
| Calibration | NIST-traceable, performed in ISO/IEC 17025-accredited laboratory |
| Brand | Theva |
|---|---|
| Origin | Germany |
| Model | TAPESTAR™ |
| Critical Current Range | 50–400 A (TAPESTAR™), 50–1000 A (TAPESTAR™ XL) |
| Measurement Principle | Non-contact magnetic induction (perpendicular field scanning with multi-channel Hall sensor array) |
| Operating Temperature | Liquid nitrogen (77 K) |
| Tape Speed | 0–55 m/h (TAPESTAR™), 0–200 m/h (TAPESTAR™ XL) |
| Axial Resolution | 0.5 mm @ 55 m/h (TAPESTAR™), 1 mm @ 55 m/h (TAPESTAR™ XL) |
| Transverse Resolution | 0.6 mm (4 mm tape), 1.5 mm (10 mm tape) |
| Magnetic Field Range | 0–40 mT (TAPESTAR™), 0–120 mT (TAPESTAR™ XL) |
| Sensor Channels | 7 (TAPESTAR™), 21 (TAPESTAR™ XL) |
| Accuracy | ±3% (≥15 A, calibrated reference sample) |
| Tape Width Customization | Up to 12.4 mm |
| Max. Tape Thickness | 200 µm |
| Tape Tension Control | 5 N (TAPESTAR™), 5–11 N (TAPESTAR™ XL) |
| Power Supply | 220 V / 50 Hz / 250 W (TAPESTAR™), 400 V / 3-phase / 50 Hz / 3 kW (TAPESTAR™ XL) |
| Dimensions (L×W×H) | 750 × 710 × 860 mm (TAPESTAR™), 2630 × 880 × 1550 mm (TAPESTAR™ XL) |
| Weight | 98 kg (TAPESTAR™), 475 kg (TAPESTAR™ XL) |
| Environmental Requirements | 5–35 °C, 10–90% RH (non-condensing), vibration-isolated installation |
| Brand | Thorlabs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MC2000 |
| Pricing | Upon Request |