| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Model | HMAS-D10SMZ |
| Measurement Range | 0–3000 HV |
| Test Forces (6 Levels) | 0.3, 0.5, 1, 3, 5, 10 kgf |
| Standards Compliance | GB/T 4340 |
| Automatic Turret | Yes |
| Loading Mechanism | Gear-Driven Force Application |
| Z-Axis Drive | Precision Lead Screw |
| XY Manual Stage | 100 × 100 mm platform, 25 × 25 mm travel, 0.01 mm mechanical resolution |
| Objective Lenses | 10×, 20× (optional: 40×, 50×, 100×) |
| Total Optical Magnification | 100×, 200× (dual-scale measurement) |
| Digital Image Magnification (via CCD + PC) | ~400×–800× |
| Indentation Imaging | High-Resolution CCD + Real-Time Image Acquisition Processor |
| Software | YANRUN HMAS Hardness Analysis Suite (v5.x) with Auto-Indent Recognition, SPC, 3D Indent Modeling, Simulated Focus, 12-Color Backgrounds, ASTM/GB Hardness Conversion, PDF/Word/Excel Reporting, GLP-Compliant Audit Trail |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HMAS-D10SMZB |
| Instrument Type | Microhardness Tester |
| Measurement Range | 0–3000 HV |
| Test Forces (6-level) | 0.3, 0.5, 1, 3, 5, 10 kgf |
| Objective Lenses | 10×, 20× |
| Total Optical Magnification | 100×, 200× (digital display up to ~400×–800×) |
| X-Y Motorized Stage | 50 mm × 50 mm travel, 185 mm × 140 mm platform, 50 kg load capacity |
| Dwell Time | 1–60 s (adjustable in 1 s increments) |
| Specimen Max Height | 180 mm |
| Indenter-to-Chamber Distance | 130 mm |
| Compliance | GB/T 4340.2, JJG 151 |
| Software | Multi-language (English, Chinese, German, Spanish, Russian), ASTM E384-compliant curvature correction, GLP/GMP-ready audit trail & user permission management |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HMAS-D3000M7 |
| Instrument Type | Brinell Hardness Tester |
| Measuring Range | 8–650 HBW |
| Loading Method | Motor-driven Force Application via Load Cell |
| Standard Compliance | GB/T 231.1, GB/T 231.2, JJG 150 |
| Test Force Levels | 62.5–3000 kgf (612.5–29,400 N) |
| Indentation Imaging | 130 W Industrial Camera |
| Magnification | 20× Digital Eyepiece |
| Resolution | 0.5 µm |
| Dwell Time | 0–60 s (1 s increments) |
| Max Specimen Height | 230 mm |
| Distance from Indenter Center to Chamber Wall | 155 mm |
| Data Output Formats | Excel, Word, PDF |
| Hardness Scale Conversions | HRC, HV, HK, HBW, HRA, HRD, HR15N/30N/45N, HR15T/30T/45T, HRB, HRF |
| Display | Touchscreen + PC Software Interface |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 535 × 185 × 750 mm |
| Net Weight | 116.5 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HMAS-D5/10/30/50MZA |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 8–3000 HV |
| Turret Control | Motorized, PC-controlled |
| Test Force Options | 0.2–50 kgf (6–12 selectable loads per capacity tier) |
| Load Application | Fully Automated (loading/holding/unloading) |
| Standards Compliance | GB/T 4340, ISO 6507 |
| XY Stage Travel | 25 × 25 mm (optional 50 × 50 mm) |
| Minimum Resolution | 0.06 µm (at 20× objective) |
| Dwell Time | 1–60 s (1 s increments) |
| Max Specimen Height | 60 mm |
| Depth from Indenter to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 50.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HMAS-D5 / HMAS-D10 / HMAS-D30 / HMAS-D50 |
| Instrument Type | Vickers Hardness Tester |
| Hardness Measurement Range | 8–3000 HV |
| Test Force Options | 0.2–50 kgf (6 force levels per capacity tier) |
| Compliance | GB/T 4340, ISO 6507 |
| Minimum Detectable Indentation Resolution | 0.06 µm (with 20× objective) |
| Maximum Specimen Height | 235 mm |
| Distance from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 54.0 kg |
| Gross Weight | 72.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HMAS-D5M / HMAS-D10M / HMAS-D30M / HMAS-D50M |
| Instrument Type | Vickers Hardness Tester |
| Hardness Measurement Range | 8–3000 HV |
| Test Force Options | 0.2–50 kgf (6 force ranges per model) |
| Compliance | GB/T 4340, ISO 6507 |
| Minimum Detectable Indentation Resolution | 0.06 µm (with 20× objective) |
| Maximum Specimen Height | 235 mm |
| Distance from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 54.0 kg |
| Gross Weight | 72.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HMAS-D5MZ / D10MZ / D30MZ / D50MZ |
| Instrument Type | Vickers Hardness Tester |
| Hardness Measurement Range | 8–3000 HV |
| Test Force Options | 0.2–50 kgf (6 force ranges across four models) |
| Compliance | GB/T 4340, ISO 6507 |
| Minimum Detectable Indentation Resolution | 0.06 µm (with 20× objective) |
| Maximum Specimen Height | 235 mm |
| Distance from Indenter Axis to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 54.0 kg |
| Gross Weight | 72.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HMAS-D5Z / HMAS-D10Z / HMAS-D30Z / HMAS-D50Z |
| Instrument Type | Vickers Hardness Tester |
| Measuring Range | 8–3000 HV |
| Test Force Options | 0.2–50 kgf (6–60 kgf range across models) |
| Standards Compliance | GB/T 4340, ISO 6507 |
| Minimum Detection Unit | 0.06 µm (at 20× objective) |
| Max Specimen Height | 235 mm |
| Depth from Indenter Center to Chamber Wall | 130 mm |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 570 × 220 × 680 mm |
| Net Weight | 54.0 kg |
| Gross Weight | 72.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HMAS-DHB |
| Instrument Type | Brinell Hardness Tester |
| Hardness Range | 8–650 HBW |
| Test Forces | 62.5 kgf, 100 kgf, 125 kgf, 187.5 kgf, 250 kgf, 500 kgf, 750 kgf, 1000 kgf, 1500 kgf, 3000 kgf |
| Indentation Ball Diameters | 2.5 mm, 5 mm, 10 mm |
| Measurement Scale Options | 12 standardized Brinell scales (e.g., HBW 2.5/62.5, HBW 10/3000) |
| Digital Eyepiece Magnification | 20× |
| Eyepiece Resolution | 0.5 µm |
| Max Specimen Height | 250 mm |
| Max Distance from Indenter to Column | 150 mm |
| Load Duration Control | 0–60 s (1 s increments) |
| Hardness Scale Conversion | HRA, HRB, HRC, HRD, HEF, HK, HV, HR15N–HR45T, HBW |
| Power Supply | AC 220 V |
| Dimensions (W×D×H) | 520 × 230 × 750 mm |
| Weight | ~130 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HMAS-DHBL |
| Instrument Type | Brinell Hardness Tester |
| Hardness Range | 8–650 HBW |
| Test Forces | 62.5 kgf, 100 kgf, 125 kgf, 187.5 kgf, 250 kgf, 500 kgf, 750 kgf, 1000 kgf, 1500 kgf, 3000 kgf |
| Maximum Specimen Height | 235 mm |
| Depth from Indenter Center to Column | 155 mm |
| Indenter Balls | Ø2.5 mm, Ø5 mm, Ø10 mm Tungsten Carbide |
| Digital Eyepiece Magnification | 20× |
| Eyepiece Resolution | 0.5 µm |
| Load Duration | 0–60 s (adjustable in 1-s increments) |
| Hardness Scale Conversion | HRA, HRB, HRC, HRD, HEF, HK, HV, HR15N/30N/45N, HR15T/30T/45T, HBW |
| Compliance | GB/T 231.2, JJG 150 |
| Data Storage | Up to 30 test records |
| Loading Control | Motor-driven, closed-loop force feedback |
| Power Supply | AC 220 V |
| Dimensions (W×D×H) | 520 × 230 × 750 mm |
| Weight | ~130 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 1–3000 HV |
| Operating Temperature Range | 400–1600 °C (up to 1700 °C furnace rating) |
| Maximum Test Load | ≤50 kgf (adjustable in continuous or stepwise mode) |
| Load Holding Duration | ≥3 h at ≤1600 °C |
| Optical Observation Capability | Real-time in-situ imaging up to 1600 °C (10×/20× objectives |
| Positioning Accuracy | ≤±1 µm (optional), Resolution: 0.01 µm |
| Thermal Stability | Furnace control precision ≤±1 °C |
| Sample Handling | Rapid in-situ exchange at full operating temperature (≤100 s at 1600 °C) |
| Indenter Material | Refractory ceramic/metallic composite, repairable up to 1700 °C |
| Cooling Systems | Dual-mode inert-gas convection (air & spiral external flow), water-cooled enclosure (±0.3 °C stability) |
| Compliance Support | Configurable for GLP/GMP-aligned data integrity (audit trail, electronic signatures, 21 CFR Part 11 readiness) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0–3000 HV |
| Operating Temperature Range | 400–1600 °C (furnace), up to 1700 °C (indenter module) |
| Maximum Load Capacity | ≤50 kg (continuous variable loading, ≥50 g minimum) |
| Optical Magnification | 880× / 1760× (standard), up to 11,000× (optional) |
| Positioning Resolution | 0.01 µm |
| Thermal Stability | ±1 °C (furnace cavity), ±0.3 °C (chamber ambient) |
| Sample Exchange Time at 1600 °C | ≤100 s |
| Indenter Service Life | Multiple in-situ repairs possible up to 1700 °C |
| Environmental Control | Inert atmosphere glovebox (H₂O/O₂ ≤1 ppm), dual-stage gas-cooling & forced-air thermal management |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HMAS-HB |
| Instrument Type | Brinell Hardness Tester |
| Total Test Forces | 62.5, 100, 125, 187.5, 250, 500, 750, 1000, 1500, 3000 kgf |
| Measurement Resolution | 0.3 µm |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Operating Temperature Range | 400–1600 °C |
| Maximum Furnace Temperature | 1750 °C |
| Load Capacity | 0.4–60 kgf (3.92–588 N) |
| Force Resolution | 0.01 % FS |
| Force Accuracy | ±0.3 % FS |
| Positioning Accuracy | ≤±1 µm |
| Positioning Resolution | 0.01 µm |
| X/Y/Z Travel | 300 × 150 × 50 mm |
| Optical Magnification (at 1600 °C) | 880× / 1760× |
| Objective Lenses | 10× / 20× (rated to 1600 °C) |
| Field of View (1600 °C) | 800 µm / 400 µm |
| Optical Resolution | 4.2–1.1 µm |
| Atmosphere | High-purity argon (≤1 ppm O₂/H₂O) |
| Cooling | Dual-mode (forced-air + inert-gas convection) |
| Sample Size Limit | Ø60 mm × 60 mm |
| In-situ Dwell Time at 1600 °C | ≥3 h |
| Indenter Material | Sintered refractory ceramic (1700 °C repairable, flexural strength ≥430 MPa, fracture toughness ≥5.8 MPa·m½) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Operating Temperature Range | 200–1200 °C |
| Load Range | 1–30 kgf (standard), up to 150 kgf (optional) |
| Optical Magnification | 10× objective (20× optional), system magnification up to 2000× |
| Temperature Control Accuracy | ±1 °C |
| Temperature Field Uniformity | ≤±5 °C |
| Heating Element | Silicon Carbide Rods |
| Thermocouple Type | S-type |
| Maximum Sample Size | Ø20 mm × 20 mm |
| Load Application Method | Force-controlled, fixed-step loading (16/32/61/127 steps optional) |
| Load Resolution | 0.01% FS |
| Hold Time | Up to 30 min |
| Auto Sample Exchange Time | ≤20 s within isothermal field |
| Motion Control | 4-axis synchronized, positioning accuracy ≤±1.5 µm, resolution ≤0.1 µm |
| Objective Resolution | 1.44 µm (10×), 1.19 µm (20×) |
| Cooling Options | Recirculating water (13 L/min), inert gas quench (≤10 s), or forced-air (4-nozzle, 90° angle) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Load Range | 0.1–30 kgf (standard), up to 150 kgf (optional) |
| Temperature Range | 200–1200°C |
| Temperature Uniformity | ≤ ±5°C across 100×80×80 mm furnace chamber |
| Thermal Control Accuracy | ±1°C |
| Heating Element | Silicon Carbide Rods |
| Thermocouple | Type S Platinum-Rhodium |
| Objective Working Temp | ≤1200°C (10× or 20× high-temp objective) |
| Optical Magnification | 1000× (standard), 2000× (optional) |
| Objective Resolution | 1.44 µm (10×), 1.19 µm (20×) |
| Loading Modes | Constant Load / Constant Rate |
| Load Resolution | 0.01% FS |
| Hold Time | Up to 72 h |
| Multi-Axis Motion Control | Up to 9 axes, positioning accuracy ≤ ±1 µm |
| Sample Exchange Time (in-situ) | ≤50 s at 1200°C |
| Cooling Options | Circulating air (≤5 s cooldown), optional water/gas cooling modules |
| Compliance | Designed for GLP/GMP-aligned materials R&D environments |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HMAS-HT1500CM |
| Instrument Type | Vickers Hardness Tester |
| Temperature Range | 400–1400 °C |
| Max Load Capacity | 30 kgf (optional up to 150 kgf) |
| Objective Working Temp | ≤1400 °C (10× or 20×) |
| Load Control | Continuous variable loading with real-time force–time acquisition |
| Hold Time | Up to 72 h |
| Temperature Uniformity | ±5 °C across 100×80×80 mm furnace cavity |
| Thermal Stability | ±1 °C |
| Heating Rate | 1–40 °C/min |
| Optical Resolution | 1.44 µm (10×), optional 1.19 µm (20×) |
| XY Motion Precision | ≤±1 µm |
| Z-Axis Resolution | ≤0.1 µm |
| Sample Size Limit | Ø30×30 mm |
| Quick-Change Cycle | ≤50 s at 1400 °C |
| Cooling | Dual-mode (water + inert gas), <5 s cooldown to <55 °C |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HMAS-HT600 |
| Instrument Type | Vickers Hardness Tester |
| Temperature Range | Room Temperature to 600 °C |
| Load Range | 1–30 kgf (standard), up to 150 kgf (optional) |
| Optical Magnification | 10× objective (20× optional), system magnification up to 2000× |
| Temperature Control Accuracy | ±1 °C |
| Heating Element | HRE high-temperature alloy |
| Thermocouple | Type S |
| Furnace Chamber Dimensions | 80 × 80 × 60 mm |
| Sample Max Size | Ø20 × 20 mm |
| Auto Sample Exchange Time | ≤20 s (in-situ at 600 °C) |
| Multi-axis Motion Control | 4-axis, resolution ≤0.1 µm, positioning accuracy ≤±1.5 µm |
| Indenter Material | Cubic Boron Nitride (CBN) with Inconel shank |
| Indenter Geometry | Square pyramid (standard), spherical/conical/cylindrical (optional) |
| Image Resolution | 1.44 µm (10×), 1.19 µm (20×) |
| Hold Time | Up to 30 min |
| Force Resolution | 0.01% FS |
| Load Accuracy | ±2% (≤1 kgf), ±0.5% (>1 kgf) |
| Heating Rate | 1–40 °C/min |
| Temperature Gradient Uniformity | ≤±5 °C across chamber |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Model | HMAS-HT700CM |
| Operating Temperature Range | Ambient to 600 °C |
| Load Range | 0.1–30 kgf (standard), up to 150 kgf (optional) |
| Optical System | 10× objective rated for continuous operation at 600 °C (20× optional) |
| Temperature Uniformity | ≤ ±5 °C across 100 × 80 × 80 mm furnace cavity |
| Temperature Control Accuracy | ±1 °C |
| Maximum Dwell Time | 72 h |
| Multi-Axis Motion Control | Up to 9 axes, positional resolution ≤ 0.1 µm |
| Image Magnification | 1000× (2000× optional) |
| Objective Resolution | 1.44 µm (1.19 µm with 20×) |
| Indenter Material | Cubic Boron Nitride (CBN) pyramid |
| Indenter Shank | Inconel alloy, 110 mm length |
| Sample Size Limit | Ø30 × 30 mm |
| Rapid Sample Exchange | ≤50 s within isothermal field |
| Force-Time Data Acquisition | Real-time, synchronized with thermal and positional feedback |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 1–3000 HV |
| Operating Temperature Range | Ambient to 800 °C |
| Load Capacity | Standard 30 kgf, Optional 1–150 kgf |
| Optical System | 10× Objective (20× Optional), 1000× Display Magnification (2000× Optional) |
| Temperature Uniformity | ≤ ±5 °C Across 80 × 80 × 60 mm Furnace Chamber |
| Thermal Control Accuracy | ±1 °C |
| Heating Rate | 1–40 °C/min |
| Sample Size Limit | ≤ φ20 × 20 mm |
| Auto-Sample Exchange Time | ≤ 20 s Within Isothermal Field |
| Multi-Axis Motion Control | 4-Axis, Positioning Accuracy ≤ ±1.5 µm |
| Force Resolution | 0.01% FS |
| Load Application Precision | ±2% (≤1 kgf), ±0.5% (>1 kgf) |
| Indenter Material | Cubic Boron Nitride (CBN) Pyramid |
| Optional Indenters | Spherical, Conical, Cylindrical |
| Image Recognition & In-Situ Analysis | Integrated High-Temperature Imaging and Automated Indentation Evaluation |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HMAS-HT900CM |
| Instrument Type | Vickers Hardness Tester |
| Maximum Operating Temperature | 800 °C |
| Load Range | 0.1–30 kgf (standard), up to 150 kgf (optional) |
| Load Control Modes | Constant Load / Constant Loading Rate |
| Load Resolution | 0.01% FS |
| Temperature Uniformity | ≤ ±5 °C across 100 × 80 × 80 mm chamber |
| Temperature Stability | ±1 °C |
| Heating Element | HRE high-temp alloy |
| Thermocouple | Type S |
| Objective Working Temp | ≤ 800 °C (10× or 20×) |
| Optical Magnification | 1000× (standard), 2000× (optional) |
| Objective Resolution | 1.44 µm (10×), 1.19 µm (20×) |
| In-situ Dwell Time | Up to 72 h |
| Sample Size Limit | Ø30 × 30 mm |
| Multi-axis Motion Control | Up to 9 axes |
| Positioning Accuracy | ≤ ±1 µm |
| Z-axis Travel | 12 mm |
| XY Stage Travel (10×) | 250 × 90 mm |
| Sample Exchange Time (in situ) | ≤ 50 s at 800 °C |
| Cooling Options | Circulating water (≤ ±0.3 °C stability), inert gas jet (cool-down ≤ 5 s), optional glovebox (H₂O/O₂ ≤ 1 ppm) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Model | HMAS-UHT1700CM |
| Load Range | 0.1–30 kgf (standard), optional up to 150 kgf |
| Operating Temperature Range | 400–1600 °C (full-field uniformity) |
| Optical Working Temperature | ≤1600 °C (10× or 20× objective) |
| Temperature Control Accuracy | ±1 °C |
| Max. Dwell Time | 72 h |
| Force Resolution | 0.01% FS |
| Multi-Axis Control | Up to 9 axes |
| Sample Size Limit | Ø30 mm × 30 mm |
| Heating Element | U-shaped MoSi₂ (4 units) |
| Thermocouple | Type B |
| Furnace Cavity | 100 × 80 × 80 mm³ |
| Image Magnification | 1000× (10× objective), optional 2000× (20× objective) |
| Objective Resolution | 1.44 µm (10×), optional 1.19 µm (20×) |
| Rapid Sample Exchange | ≤50 s at 1600 °C |
| Cooling | Dual-mode (water + inert gas), ≤5 s cooldown to safe handling |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HR-150A |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | HRA: 20–88, HRB: 20–100, HRC: 20–70 |
| Preliminary Test Force | 98.07 N (10 kgf) |
| Total Test Forces | 588 N (60 kgf), 980 N (100 kgf), 1471 N (150 kgf) |
| Maximum Specimen Height | 170 mm |
| Distance from Indenter Center to Front of Machine | 135 mm |
| Hardness Resolution | 0.5 HR |
| Dimensions (W×D×H) | 466 × 238 × 630 mm |
| Weight | 65 kg |
| Compliance | GB/T 230.2, JJG 112 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HR-150DT |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | HRA: 20–88 |
| HRB | 20–100 |
| HRC | 20–70 |
| Preliminary Test Force | 98.07 N (10 kgf) |
| Total Test Forces | 588 N (60 kgf), 980 N (100 kgf), 1471 N (150 kgf) |
| Maximum Specimen Height | 200 mm |
| Depth from Anvil Center to Front | 135 mm |
| Hardness Resolution | 0.5 HR |
| Dwell Time Adjustment | 0–99 s (1 s increments) |
| Compliance | GB/T 230.2, JJG 112 |
| Power Supply | 220 V AC |
| Weight | 70 kg |
| Dimensions (W×D×H) | 500 × 250 × 700 mm |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HRS-150F |
| Instrument Type | Rockwell Hardness Tester |
| Hardness Range | HRA: 20–88, HRB: 20–100, HRC: 20–70 |
| Total Test Forces | 588.4 N (60 kgf), 980.7 N (100 kgf), 1471 N (150 kgf) |
| Preliminary Test Force | 98.07 N (10 kgf) |
| Indentation Depth Resolution | 0.1 HR |
| Maximum Specimen Height | 190 mm |
| Anvil-to-Indenter Distance | 160 mm |
| Test Force Dwell Time | 0–60 s (adjustable in 1 s increments) |
| Compliance | GB/T 230.2, JJG 112 |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 540 × 225 × 755 mm |
| Net Weight | 90.5 kg |
| Gross Weight | 110.5 kg |
| Display | 7-inch color TFT touchscreen |
| Data Output | Integrated thermal printer |
| Hardness Scale Conversion | Automatic conversion across 15 Rockwell scales (HRA, HRBW, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRP, HRR, HRS, HRV) and cross-scale equivalents (HBW, HV, HK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rockwell Hardness Tester |
| Model | HRS-150M |
| Measurement Range | HRA: 20–88, HRB: 20–100, HRC: 20–70 |
| Total Test Forces | 588 N (60 kgf), 980 N (100 kgf), 1471 N (150 kgf) |
| Maximum Specimen Height | 180 mm |
| Testing Zone Dimensions | 200 mm (H) × 160 mm (D) |
| Indentation Depth Resolution | 0.1 HR |
| Initial Test Force | 98.07 N (10 kgf) |
| Dwell Time Adjustment | 0–60 s (1 s increments) |
| Compliant Standards | GB/T 230.2, JJG 112 |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HV-1000 |
| Instrument Type | Microhardness Tester |
| Hardness Measurement Range | 0.001–6000 HV |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HV-1000 / HV-1000Z |
| Instrument Type | Micro-Vickers Hardness Tester |
| Hardness Range | 0.001–6000 HV |
| Test Forces (8-step) | 0.098 N, 0.245 N, 0.490 N, 0.981 N, 1.961 N, 2.942 N, 4.903 N, 9.807 N |
| Equivalent GF Values | 10 gf, 25 gf, 50 gf, 100 gf, 200 gf, 300 gf, 500 gf, 1000 gf |
| Test Force Standards | HV0.01, HV0.025, HV0.05, HV0.1, HV0.2, HV0.3, HV0.5, HV1 |
| Maximum Specimen Height | 55 mm |
| Depth from Indenter Center to Chamber Wall | 110 mm |
| X-Y Stage Travel | 25 mm × 25 mm |
| Minimum Detection Resolution | 0.5 µm |
| Total Magnification | 100× (observation), 400× (measurement) |
| Optical System | Dual-objective turret (10× observation, 40× measurement), 10× mechanical eyepiece |
| Load Application Mode | Fully automated (loading–dwell–unloading), loading speed: 0.05 mm/s |
| Dwell Time | 0–99 s (1 s increments) |
| Compliance Standard | GB/T 4340.1–2012 (equivalent to ISO 6507-1 and ASTM E384) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 460 mm × 230 mm × 490 mm |
| Construction | Precision cast aluminum frame |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Microhardness Tester |
| Model | HV-1000Z |
| Measurement Range | 0.001–6000 HV |
| Test Forces | 0.098–9.807 N (10–1000 gf), 8 selectable levels |
| Indentation Scales | HV0.01, HV0.025, HV0.05, HV0.1, HV0.2, HV0.3, HV0.5, HV1 |
| Optical Magnification | 100× (observation), 400× (measurement) |
| Minimum Detectable Indentation | 0.25 µm |
| X-Y Stage Travel | 25 × 25 mm |
| Maximum Specimen Height | 70 mm |
| Depth from Indenter to Chamber Wall | 110 mm |
| Load Application | Fully Automatic (loading/holding/unloading) |
| Dwell Time | 0–99 s (1 s increments) |
| Compliance | GB/T 4340 |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 440 × 220 × 460 mm |
| Net Weight | 25.0 kg |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HV-5/10/30/50 |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0.001–6000 HV |
| Test Forces | 0.2–50 kgf (HV-5: 0.2–5 kgf |
| HV-10 | 0.3–10 kgf |
| HV-30 | 1–30 kgf |
| HV-50 | 1–50 kgf) |
| Objective Magnifications | 10× (observation), 20× (measurement) |
| Eyepiece | 10× mechanical eyepiece |
| Total Magnification | 100× (observation), 200× (measurement) |
| Minimum Detection Unit | 0.25 µm |
| Indentation Measurement Method | Manual micrometer drum reading with automatic hardness calculation |
| Dwell Time | 0–99 s (1-s increments) |
| Max Specimen Height | 220 mm |
| Distance from Indenter to Column | 130 mm |
| Dimensions (H×W×D) | 680 × 216 × 565 mm |
| Power Supply | AC 220 V / 50 Hz |
| Compliance | GB/T 4340.2, JJG 151 |