Other Physical Property Test Instruments
Filter
Showing 151–180 of 984 results
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SES |
| Temperature Range | RT +5 to 450 °C |
| Power | 125–290 W (model-dependent) |
| Flask Capacity | 300, 500, or 1000 mL |
| Extractor Tube Dimensions | 45 mm ID × 130 mm H |
| Sintered Glass Porosity | 20–35 µm or 100–200 µm |
| Configuration | 3-position or 6-position modular heating block with independent temperature control per position |
| Display | Dual LED readout (setpoint & actual temperature, 0.1 °C resolution) |
| Vessel Compatibility | Flat-bottom and round-bottom flasks |
| Solvent Recovery | Integrated reflux condensation and closed-loop solvent recycling |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TFX 430 |
| Temperature Range | −100 °C to +500 °C (−148 °F to +932 °F) |
| Temperature Accuracy | ±0.05 °C (−50 °C to +199.99 °C), ±0.2 °C (other ranges) |
| Temperature Resolution | 0.01 °C (−10.00 °C to +199.99 °C), 0.1 °C (other ranges) |
| Humidity Range | 0–100 %RH |
| Humidity Accuracy | ±2.5 %RH (10–90 %RH), ±0.5 °C (temperature) |
| Humidity Resolution | 0.1 %RH, 0.1 °C |
| Sampling Interval | 1–15 s |
| IP Rating | IP40 |
| Dimensions | 115 × 54 × 22 mm |
| Weight | ~90 g |
| Battery | 3.0 V Li-ion, 1000 mAh (up to 5-year service life) |
| Sensor Type | External capacitive humidity sensor (TFH 61) + external NTC thermistor probe |
| Calibration | Factory-calibrated with traceable certificate |
| Compliance | Conforms to DIN EN 60751 (Pt100 reference context), ISO/IEC 17025-aligned calibration documentation |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | THI 350 |
| Temperature Range | −60 °C to +500 °C |
| Temperature Accuracy | ±1.0 °C (15–35 °C), ±2.0 °C (−33–500 °C and outside nominal range) |
| Emissivity Adjustment | 0.1–1.0 (default 0.95) |
| Temperature Resolution | 0.1 °C (−9.9 to 199.9 °C) |
| Response Time | 1 s |
| Relative Humidity Range | 1–99 % RH |
| RH Accuracy | ±3 % RH (20–80 % RH), ±5 % RH (outside that range) |
| Distance-to-Spot Ratio | 12:1 |
| Operating Ambient Temperature | 0–50 °C |
| Power | 2 × AAA alkaline batteries (typical life: 180 h, min. 140 h continuous) |
| Dimensions (L×W×H) | 46 × 143 × 184.8 mm |
| Calibration | Factory-calibrated with traceable certificate |
| Probe Types Supported | Fixed capacitive (TFH 610), flexible cable-mounted capacitive (TFH 620), and integrated infrared + capacitive (THI 350) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VDM-250.1N |
| Instrument Type | Portable Immersion Densimeter & Viscometer |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Temperature Range | −40 to +85 °C |
| Temperature Accuracy | ±0.1 or ±0.2 °C |
| Viscosity Range | up to 10,000 mPa·s (cP) |
| Viscosity Accuracy | ±1% of span |
| Viscosity Repeatability | ±0.5% of span |
| Measurement Depth | up to 6 m |
| Display | OLED with backlight |
| Data Storage | 2000 records |
| Communication | Bluetooth & USB |
| Sensor Materials | SS 316L, NiSpan C, or Hastelloy C-22 (optional) |
| Certifications | ATEX, IECEx HazLoc |
| Battery | NiMH 3.6 V, 2500 mAh (≈40 h operation) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VDM-250.2N |
| Instrument Type | Portable immersion densimeter & viscometer |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Temperature Range | −40 to +85 °C |
| Temperature Accuracy | ±0.1 or ±0.2 °C |
| Viscosity Range | up to 10,000 mPa·s (cP) |
| Viscosity Accuracy | ±1% of span |
| Viscosity Repeatability | ±0.5% of span |
| Max. Immersion Depth | 30 m |
| Data Storage | 2000 measurements |
| Communication | Bluetooth & USB |
| Certified | ATEX, IECEx HazLoc |
| Sensor Materials | SS 316L, NiSpan C, Hastelloy C-22 |
| Battery | NiMH 3.6 V, 1500 mAh (≈12 h operation) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VDM-300 heat |
| Density Range | 0.5–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³, ±0.0005 g/cm³, or ±0.001 g/cm³ (selectable) |
| Kinematic Viscosity Accuracy | ±1% of reading |
| Dynamic Viscosity Range | 0.2–2000 mPa·s |
| Temperature Range | up to +100 °C |
| Probe Material | 316L stainless steel, nickel-based alloy, Hastelloy C-22 |
| Dimensions | 140 × 100 × 290 mm |
| Weight | ~2 kg |
| Compliance | CE marked per EN 61326, EN 5011, EN 50082-2 |
| Connectivity | Bluetooth to PC and printer |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation required) |
| Sample Type | Solid powders, granules, bulk solids, foams, slurries, and filtration media |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ISO 12154:2014 compliant) |
| Volume Range | 0.01–100 cm³ |
| Temperature Range | 5–35 °C |
| Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL |
| Optional Sample Cups | 10 mL, 30 mL, 60 mL |
| Pressure Control | Absolute pressure mode (0–130 kPa), vacuum-assisted degassing |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Software Interface | Windows 7 or later |
| Communication | RS-232 or USB |
| Power | AC 220 V ±22 V, 50 Hz |
| Dimensions | 485 × 350 × 220 mm (L×W×H) |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014, ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-1206B |
| Price Range | USD 5,600 – 7,000 (est.) |
| Application Field | General-purpose true density analysis |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — correction per technical specs) |
| Sample Type | Solid materials (powders, granules, monoliths, foams, slurries, filters) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium displacement, based on ideal gas law) |
| Volume Range | 0.01–100 cm³ |
| Temperature Operating Range | 5–35 °C |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL (with interchangeable sample cups: 10 mL, 30 mL, 60 mL) |
| Pressure Control | Absolute pressure mode (vacuum-based), 0–130 kPa absolute |
| Test Gas | 99.99% purity N₂ or He (user-supplied) |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±10%, 50 Hz, <200 W (vacuum mode) |
| Dimensions | 485 × 350 × 220 mm |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014 (gas pycnometry), ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Category | Portable Solid Density Analyzer |
| Measurement Principle | Gas Displacement Pycnometry (ISO 12154:2014, GB/T 24586–2009) |
| Sample Volume Range | 0.01–100 cm³ |
| Temperature Operating Range | 5–35 °C |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL (with interchangeable sample cups: 10 mL, 30 mL, 60 mL) |
| Pressure Mode | Absolute Vacuum Mode (0–130 kPa absolute) |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Vacuum Mode Power Consumption | <200 W |
| Dimensions (L×W×H) | 485 × 350 × 220 mm |
| Weight | 14 kg |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (not portable — corrected per technical specification: 14 kg, fixed installation) |
| Sample Type | Solids (powders, granules, bulk solids, foams, filter media, slurries) |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ASTM D5550 / ISO 12154 compliant) |
| Density Range | 0.01–100 g/cm³ |
| Temperature Control Range | 15–39 °C |
| Repeatability | ±0.02% RSD |
| Resolution | 0.00001 g/cm³ |
| Sample Volume Capacity | 0.01–100 cm³ (with interchangeable sample chambers: 10 mL, 30 mL, 60 mL, and fixed 100 mL reference chamber) |
| Test Duration | ~3 min per analysis (fully automated) |
| Pressure Mode | Absolute pressure vacuum system (0–130 kPa absolute), integrated vacuum pump |
| Calibration Standard | Certified stainless steel sphere (included) |
| Software Interface | Windows 7 or later, RS232/USB |
| Compliance | GB/T 24586–2009, ASTM D5550–22, ISO 12154:2014, USP <699> (for density determination in pharmaceutical excipients) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JL-1206B |
| Instrument Type | True Density Analyzer |
| Form Factor | Benchtop (Not Portable — corrected per technical specification: 14 kg, fixed installation required) |
| Sample Type | Solid powders, granules, bulk solids, foams, filters, slurries |
| Measurement Principle | Gas Pycnometry (Nitrogen or Helium Displacement, ISO 12154:2014 compliant) |
| Analysis Stations | 1 |
| Standard Chamber Volume | 100 mL |
| Optional Sample Cups | 10 mL, 30 mL, 60 mL |
| Volume Range | 0.01–100 cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Accuracy | ±0.01% (relative) |
| Temperature Range | 5–35 °C |
| Operating Pressure | Absolute pressure mode, 0–130 kPa |
| Test Gas | 99.99% N₂ or He (user-supplied) |
| Calibration Standard | Certified stainless-steel sphere |
| Data Interface | RS232 or USB |
| Software Platform | Windows 7 or later |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Power Consumption | <200 W (vacuum mode), <50 W (positive-pressure mode) |
| Dimensions | 485 × 350 × 220 mm (L×W×H) |
| Weight | 14 kg |
| Compliance | GB/T 24586–2009, ISO 12154:2014, ASTM D5550–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-A3-01 |
| Price Range | USD 310 – 395 |
| Standard Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (customizable to 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale Range | 7.5–10 cm |
| Probe Rod Material | Stainless Steel |
| Test Principle | Fixed-base funnel deposition method for conical pile formation on horizontal metallic substrate |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-A301 |
| Price Range | USD 310 – 395 |
| Standard Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (optional 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale | 10 cm (range: 7.5–10 cm) |
| Probe Rod Material | Stainless Steel |
| Measurement Principle | Fixed-base funnel deposition method (conical pile geometry) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-A301 |
| Price Range | USD 310 – 395 |
| Standards Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (optional 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale | 10 cm (adjustable range: 7.5–10 cm) |
| Probe Rod Material | Stainless Steel |
| Measurement Principle | Fixed-Base Funnel Deposition Method (Cone Formation on Horizontal Plate) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-A301 |
| Price Range | USD 310 – 395 |
| Standard Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (optional 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale Range | 10 cm (graduated in degrees) |
| Probe Rod Material | Stainless Steel |
| Measurement Principle | Fixed-Height Funnel Deposition Method (Cone Formation on Horizontal Plate) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-A301 |
| Price Range | USD 310 – 395 |
| Standard Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (optional 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale Range | 7.5–10 cm |
| Probe Material | Stainless Steel |
| Measurement Principle | Fixed-Base Funnel Deposition Method (Cone Formation on Horizontal Plate) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-A301 |
| Price Range | USD 310 – 395 |
| Standard Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (optional 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale Range | 10 cm (graduated from 0° to 90°) |
| Probe Rod Material | Stainless Steel |
| Measurement Principle | Fixed-Height Funnel Deposition Method (Cone Formation on Horizontal Plate) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-A302 |
| Instrument Type | Bulk Density Tester |
| Instrument Class | Portable |
| Measurement Target | Solid Powders & Granules |
| Application Scope | General-purpose bulk density determination of free-flowing and cohesive powders |
| Standard Compliance | GB/T 16913–2008 (Dust Physical Property Testing – Natural Packing Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Volume | 100 mL |
| Cylinder & Funnel Material | ASTM A240 Grade 304 Stainless Steel |
| Scraper Blade Width | 25 mm |
| Overall Dimensions | ~160 × 160 × 300 mm |
| Net Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Bulk Density Tester |
| Design | Portable Benchtop Unit |
| Sample Form | Dry Solid Powders and Granules |
| Compliance Standard | GB/T 16913–2008 (Natural Pile Method) |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Cone Angle | 60° |
| Cylinder Material | AISI 304 Stainless Steel |
| Scraper & Plug Rod | AISI 304 Stainless Steel |
| Dimensions | ≈ 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JL-A302 |
| Price Range | USD 310 – 370 |
| Application Field | General-purpose bulk density measurement |
| Instrument Type | Bulk Density Tester |
| Form Factor | Benchtop (Not Portable — Corrected per ASTM D1895 & ISO 697) |
| Sample Type | Solid Powders and Granules |
| Primary Function | Determination of Uncompacted (Loose) Bulk Density of Free-Flowing Powders |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Type | Bulk Density Tester |
| Model | JL-A302 |
| Design | Portable Benchtop Unit |
| Measurement Principle | Free-Fall Natural Packing Method per GB/T 16913-2008 |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Angle | 60° |
| Cylinder Volume | 100 mL (AISI 304 Stainless Steel) |
| Scraper Blade | AISI 304, 25 mm wide |
| Stopper Rod | AISI 304 Stainless Steel |
| Overall Dimensions | ~160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥1000 g, Readability ≤0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer | Yes |
| Type | Bulk Density Tester |
| Design | Portable Benchtop Unit |
| Measurement Principle | Free-Fall Gravimetric Method per GB/T 16913–2008 |
| Funnel Orifice Diameter | 12.7 mm |
| Cylinder Volume | 100 mL |
| Funnel-to-Cylinder Height | 115 mm ± 2 mm |
| Funnel Included Angle | 60° |
| Cylinder Material | ASTM A240 Type 304 Stainless Steel |
| Scraper Blade & Plug Rod | 304 Stainless Steel, 25 mm Width |
| Dimensions | Approx. 160 × 160 × 300 mm |
| Weight | 3.7 kg |
| Required External Balance | Capacity ≥ 1000 g, Readability ≤ 0.02 g |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JL-A303 |
| Instrument Type | Bulk Density & Flow Rate Tester |
| Form Factor | Benchtop (Portable Design) |
| Sample Type | Free-Flowing Solid Powders |
| Primary Applications | Metal Powders, Additive Manufacturing Feedstocks, Battery Cathode/Anode Materials, Ceramic Precursors, and Advanced Powder Metallurgy |
| Standards Compliance | GB/T 1482–2010 (Hall Flow Test), GB/T 1479.1–2011 (Apparent Density by Funnel Method) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Included Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm width |
| Stopper Rod | Stainless steel 304 |
| Dimensions | Approx. 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timing Resolution | 0.01 s (external stopwatch required) |
| Recommended Balance | 1 kg capacity, 0.02 g readability (user-supplied) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Bulk Density & Flow Tester |
| Instrument Type | Portable |
| Measurement Type | Solid Powder |
| Application | Apparent density and flow rate measurement of free-flowing metal powders |
| Standards Compliance | GB/T 1482–2010 (Hall Flow), GB/T 1479.1–2011 (Apparent Density) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel Angle | 60° |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm wide |
| Stopper Rod | Stainless steel 304 |
| Dimensions | ~230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-A303 |
| Instrument Type | Bulk Density & Flow Tester |
| Design Form Factor | Benchtop (Compact) |
| Sample Type | Free-Flowing Solid Powders |
| Applicable Standards | GB/T 1482–2010, GB/T 1479.1–2011 |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Funnel Cone Angle | 60° |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel 304, 25 mm width |
| Stopper Rod | Stainless steel 304 |
| Overall Dimensions | ~230 × 170 × 300 mm |
| Net Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Required Ancillary Equipment | Analytical balance (max 1 kg, readability 0.02 g) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JLA301 |
| Price Range | USD 310 – 395 |
| Standard Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (customizable to 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale Range | 7.5–10 cm |
| Probe Rod Material | Stainless Steel |
| Measurement Principle | Fixed-base funnel deposition method per standardized conical heap geometry |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China-made) |
| Model | JLA301 |
| Price Range | USD 310 – 395 (FOB) |
| Standards Compliance | GB/T 16913–2008, GB/T 31057.3–2018 |
| Funnel Cone Angle | 60° ± 0.5° |
| Funnel Orifice Diameter | 5 mm (optional 10 mm) |
| Receiving Pan Diameter | 80 mm |
| Vertical Distance Between Funnel Tip and Pan Surface | 80 mm ± 2 mm |
| Protractor Scale | 10 cm arc length (±0.5° resolution) |
| Probe Rod Material | Stainless Steel (AISI 304) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-1 |
| Instrument Type | Tapped Density Analyzer |
| Application | Tapped density measurement of metal powders and battery materials |
| Compliance | GB/T 5162–2021, YS/T 677–2008 |
| Vibration Amplitude | 50 mm ± 0.2 mm |
| Vibration Frequency | 60 taps/min |
| Tap Count Range | 1–9999 (user-configurable) |
| Sample Positions | 3 independent stations |
| Standard Cylinders | 3 × stainless steel cylinders (ID 16.25 mm, height 80 mm, volume 16.6 mL) |
| Measurement Accuracy | ±1.5% |
| Power Supply | AC 220 V ± 22 V, 150 W |
| Dimensions | 400 × 280 × 270 mm |
| Weight | ~13 kg |
| Construction | 304 stainless steel frame and components |
| Software | Included PC-based data acquisition and reporting software (tapped density calculation, report generation, CSV export) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | JZ-10 |
| Instrument Category | Tap Density Tester |
| Form Factor | Benchtop (Not Portable — corrected per ISO/USP design standard) |
| Sample Type | Dry Powders & Granules |
| Density Measurement Range | 0–10 g/cm³ |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Vibration Frequency Options | 100 / 200 / 250 / 300 cycles/min |
| Programmable Taps | 1–9999 taps per cycle |
| Test Vessels | Removable borosilicate glass cylinders (25 mL and 100 mL, quantity varies by submodel: JZ-10A/B/C) |
| Power Supply | AC 220 V, 50 Hz, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |