Other Physical Property Test Instruments
Filter
Showing 181–210 of 993 results
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JZ-10-C |
| Instrument Type | Tap Density Tester |
| Category | Portable Solid Density Analyzer |
| Measurement Range | 0–10 g/cm³ |
| Primary Application | Tap density and bulk density measurement of powders and granular solids |
| Repeatability Error | ≤ ±1% |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Adjustable Tapping Cycles | 1–9999 |
| Selectable Vibration Frequencies | 100 / 200 / 250 / 300 taps/min |
| Dual Motion Mechanism | Vertical tapping + horizontal rotation |
| Sample Container Options | Three 25 mL and three 100 mL borosilicate glass cylinders (removable) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Software Output Formats | Word, PDF, Excel |
| Compliance Standards | GB/T 5162–2021, GB/T 31057.2–2018, Chinese Pharmacopoeia 2020 Edition <993>, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JZ-10A |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose powder density testing |
| Instrument Type | Tap density tester |
| Form Factor | Benchtop (not portable |
| Sample Type | Solid powders and granules |
| Density Measurement Range | 0–10 g/cm³ |
| Primary Function | Tap density and bulk density determination of free-flowing and cohesive powders |
| Repeatability | ≤ ±1% |
| Stroke Amplitude | 3.0 ± 0.2 mm |
| Tap Count Range | 1–9999 cycles (user-programmable) |
| Tap Frequency Options | 100, 200, 250, or 300 taps/min |
| Standard Vessel | Two 100 mL borosilicate glass cylinders |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | JZ-10A |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density measurement |
| Instrument Type | Tap density tester |
| Instrument Form Factor | Benchtop (not portable — corrected per ISO 3953 and USP <616> classification) |
| Sample Type | Solid powders & granules |
| Density Measurement Range | 0–10 g/cm³ |
| Primary Function | Determination of tap density and bulk density of free-flowing powders |
| Density Accuracy | ±1% repeatability (per ISO 3953:2022 Annex B & USP <616>) |
| Tap Amplitude | 3.0 ± 0.2 mm |
| Tap Count Range | 1–9999 cycles (user-programmable) |
| Tap Frequency Options | 100, 200, 250, or 300 taps/min |
| Test Vessel | Two included 100 mL borosilicate glass graduated cylinders (ISO/USP-compliant) |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JZ-10B |
| Instrument Category | Tap Density Tester |
| Density Measurement Range | 0–10 g/cm³ |
| Measurement Accuracy | ±1% repeatability (per GB/T 5162–2021) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Programmable Taps | 1–9999 cycles |
| Sample Capacity | ≤500 g (per cylinder) |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Cylinder Configuration | Two stations, each with one 25 mL and one 100 mL borosilicate glass cylinder |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JZ-10B |
| Instrument Type | Tap Density Tester |
| Instrument Class | Benchtop (Not Portable — corrected per ISO 14857 & USP <616>) |
| Measurement Type | Solid Powder Bulk & Tap Density |
| Density Range | 0–10 g/cm³ |
| Density Accuracy | ±1% RSD (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Adjustable Tap Counts | 1–9999 cycles |
| Selectable Tap Frequencies | 100, 200, 250, or 300 taps/min |
| Test Stations | Dual independent stations |
| Standard Vials | Two 25 mL and two 100 mL borosilicate glass graduated cylinders |
| Repeatability | ≤ ±1% (n = 10, certified reference powder) |
| Power Supply | AC 220 V, 50 Hz, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 General Chapter 0993, USP <616> |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | JZ-10C |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density tester |
| Instrument Type | Tap density tester |
| Instrument Form Factor | Benchtop (not portable — corrected per ISO/USP design norms) |
| Measurement Type | Solid powder/granule density |
| Density Range | 0–10 g/cm³ |
| Primary Function | Tap density and bulk density determination of powders and granules |
| Density Accuracy | ±1% repeatability (per GB/T 5162–2021 & USP <616>) |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Modes | Vertical oscillation + synchronized 360° rotational motion |
| Vibration Cycles | 1–9999 (user-programmable) |
| Vibration Frequencies | 100, 200, 250, or 300 taps/min (4-step selector switch) |
| Sample Vessels | Three removable calibrated glass cylinders (25 mL and 100 mL ×3 each) |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Net Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Compliance | GB/T 5162–2021, GB/T 31057.2–2018, ChP 2020 <0993>, USP <616> |
| Key | Brand: Chengdu Jingxin (CDJX) |
|---|---|
| Model | JZ-7, JZ-10A / JZ-10B / JZ-10C |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Tap Density Tester |
| Instrument Category | Benchtop Laboratory Densimeter |
| Sample Form | Solid Powders |
| Primary Measurement | Tap Density & Bulk Density |
| Vibration Amplitude | 3.0 ± 0.2 mm |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tapping Count Range | 0–9999 cycles (user-programmable) |
| Repeatability | ≤ ±1% RSD |
| Power Supply | AC 220 V, 110 W |
| Dimensions (L×W×H) | 455 × 280 × 125 mm |
| Weight | ~15 kg |
| Compliance | GB/T 5162–2021, USP <616> |
| Software | Integrated tap density calculation module with PDF/Excel export capability |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JZ-7 |
| Price Range | USD 920–1,120 (FOB) |
| Application Field | General-purpose density testing |
| Instrument Type | Bulk Density Tester |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Solid Powders |
| Measurement Scope | Tap Density & Bulk Density |
| Repeatability | ≤ ±1% |
| Vibration Amplitude | 3.0 mm ± 0.2 mm |
| Accuracy Error | ≤ ±1% |
| Number of Stations | 2 Active + 2 Waiting Positions |
| Sample Mass Capacity | ≤ 500.00 g |
| Vibration Frequency Options | 100, 200, 250, or 300 taps/min (adjustable via rotary selector) |
| Tap Count Range | 1–9999 (user-programmable) |
| Standard Compliance | GB/T 5162–2021 |
| Dimensions (W×D×H) | 450 × 280 × 180 mm |
| Net Weight | ~13 kg |
| Power Supply | AC 220 V, 50/60 Hz, 110 W |
| Included Cylinders | 25 mL, 50 mL, and 100 mL (ISO/USP-compliant borosilicate glass) |
| Data Output | PDF, Word, Excel export via proprietary software with audit trail logging |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JZ-7 |
| Instrument Type | Tap Density Tester |
| Instrument Class | Benchtop Laboratory |
| Sample Form | Solid Powders |
| Application | Tap Density & Bulk Density Measurement of Powders |
| Density Accuracy | < ±1% |
| Vibration Amplitude | 3 mm ±0.2 mm |
| Repeatability Error | ≤ ±1% |
| Vibration Frequency Options | 100 / 200 / 250 / 300 taps/min |
| Tapping Count Range | 1–9999 cycles (user-configurable) |
| Sample Capacity | ≤ 500.00 g per cylinder |
| Standard Compliance | GB/T 5162–2021 |
| Dimensions (W×D×H) | 450 × 280 × 180 mm |
| Weight | ~13 kg |
| Power Supply | AC 220 V, 110 W |
| Included Cylinders | 25 mL, 50 mL, 100 mL (each ×1) |
| Software Output | PDF, Word, Excel report generation with audit-ready calculation logs |
| Brand | Choice Analytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Clarity Chorice hz |
| Price | USD 58,000 (FOB US Port) |
| Brand | Choice Analytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Color Choice hz |
| Price | USD 68,500 (FOB US Port) |
| Brand | Choice Analytical |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Clarity Choice |
| Price | USD 62,500 (approx. based on ¥450,000 at 1 USD = ¥7.2) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Cylindrical-on-Cylindrical Tribometer |
| Pricing | Upon Request |
| Brand | DahoMeter |
|---|---|
| Origin | Guangdong, China |
| Model | DA-300M109 |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Density Meter |
| Sample Type | Solids (Rubber, Elastomers, Polymers, Composites, Ceramics, Metals, Powders) |
| Density Range | 0.001–99.999 g/cm³ |
| Density Resolution | 0.001 g/cm³ |
| Temperature Range | 0.0–100.0 °C |
| Minimum Sample Mass | 0.005 g |
| Maximum Capacity | 300 g |
| Measurement Medium | Water or User-Defined Liquid |
| Compliance | ASTM D297, GB/T 533, GB/T 9867, DIN 53516, ISO 4649, GB/T 1689, ISO 1817 |
| Data Output | RS-232C interface |
| Additional Functions | DIN Abrasion Volume, Akron Abrasion Loss, ARI Index, Volume Expansion Ratio, Foaming Ratio, Mass/Volume Change Rate, Binary Mixture Composition Estimation, Pass/Fail Auto-Judgment |
| Brand | Dantsin |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Galieo |
| Pricing | Upon Request |
| Brand | Das-Nano |
|---|---|
| Origin | Spain |
| Model | ONYX |
| Measurement Principle | Pulsed Terahertz Time-Domain Spectroscopy (THz-TDS) |
| Sample Area Range | 10 × 10 mm² to 200 × 200 mm² (customizable up to m² scale) |
| Spatial Resolution | 50 µm |
| Measurement Speed | up to 12 cm²/min |
| Output Parameters | DC conductivity (σ<sub>DC</sub>), carrier concentration (N<sub>s</sub>), drift mobility (μ<sub>drift</sub>), scattering time (τ<sub>sc</sub>), DC resistivity (R<sub>DC</sub>), surface uniformity maps |
| Compliance | Supports GLP/GMP-aligned data audit trails |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Model | DC/02 |
| Compliance | ASTM D1505-68, ISO 1183, BS 2782 Part 6 Method 620D |
| Operating Temperature | 23 °C ± 0.1 °C |
| Gradient Column | Cylindrical borosilicate glass tube |
| Calibration Reference | Set of 9 precision density marker floats (equally spaced in density) |
| Thermal Control | Integrated heating circuit + passive cooling coil |
| Application Scope | Solid plastics, thermoplastics, elastomers, and rigid polymer specimens |
| Brand | Davenport |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | DC02 |
| Pricing | Upon Request |
| Industry Application | General-Purpose Solid Density Analysis |
| Instrument Type | Density Gradient Column |
| Form Factor | Benchtop Laboratory System |
| Sample Type | Solid Particles (e.g., Plastic Pellets, Powders, Granules) |
| Density Range | 0.8000–1.5999 g/mL |
| Density Resolution | 0.0001 g/mL |
| Temperature Control | 23.0 ± 0.1 °C (Stabilized via Integrated Heating/Cooling Loop) |
| Minimum Sample Mass | 1 g |
| Origin | Hong Kong |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Origin | PRC-Made |
| Model | TR-512 |
| Pricing | Available Upon Request |
| Brand | Durham Magneto Optics |
|---|---|
| Origin | United Kingdom |
| Model | NanoMOKE3 |
| Temperature Range | 4.2–500 K |
| Maximum Magnetic Field | 5000 Oe |
| Minimum Detectable Kerr Rotation Angle | 0.5 mdeg |
| Minimum Detectable Reflectivity Change | 0.02% |
| Laser Spot Size | ≤2 µm |
| Magnetic Moment Sensitivity | ≤1 × 10⁻¹² emu |
| Sample Size Recommendation | 1–2.5 cm |
| Detection Modes | Longitudinal, Transverse, and Polar MOKE |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 480/490 |
| Price | Upon Request |
| Power Range | 4.44 kW to 56,800 kW |
| Torque Range | 2.8 N·m to 452,000 N·m |
| Speed Accuracy (end-point) | ±0.01% FS |
| Combined Accuracy (Power/Torque) | ±0.08% FS |
| Temperature Compensation Range | +75 °F to +175 °F |
| Analog Output Options | ±5 V or ±10 V dc (user-selectable) |
| Digital Interface | RS232 with full unit-aware data streaming |
| Frequency Response | 0–2 kHz |
| System Resolution | 0.02% FS (14-bit equivalent with 50% overrange) |
| EMI Hardening | IGBT-drive compatible |
| Filter Options | 11 Bessel-type cutoff settings (0.1–200 Hz, 1–2–5 decade steps) |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit) |
| Q Accuracy | <5% |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution) |
| Capacitance Range | 1 pF – 25 nF (0.1 pF resolution) |
| Main Tuning Capacitor | 17–240 pF (silver-plated, ±1 pF or <1% error) |
| Signal Source Stability | 3×10⁻⁵ ±1 digit |
| ADC Resolution | 12-bit |
| Auto-Null Compensation | Residual inductance & lead inductance |
| Display | LCD with real-time F, L, C, Q, Lₜ, Cₜ, εᵣ, tan δ |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-Factor Based) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Capacitance Range (Tuning) | 17–240 pF |
| Capacitance Direct Measurement | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| AD Sampling | 12-bit |
| Automatic Residual Inductance Compensation | Yes |
| Motorized Capacitor Tuning | Yes |
| Display | LCD with Real-Time Parameters (F, L, C, Q, Lt, Ct, εᵣ, Tn) |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-factor based) |
| Frequency Range | 10 kHz – 100 MHz (DDS Digital Synthesis, 7000:1 coverage ratio) |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 (auto/manual range, 4-digit resolution, 0.1 Q step) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH (0.1 nH resolution, <3% error) |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF (±1 pF or <1% error, 0.1 pF resolution) |
| Automatic Capacitance Search | Stepper-motor-driven |
| Residual & Lead Inductance Compensation | Yes (automated subtraction) |
| Display | LCD showing F, L, C, Q, Lₜ, Cₜ, εᵣ, Tₙ, etc. |
| AD Sampling | 12-bit high-precision ADC |
| Q Pre-set Pass/Fail Threshold | 5–1000 with audible/visual alert |
| Operating Mode | Auto-resonance sweep or manual tuning |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Parallel-Plate Capacitor Configuration) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Error | ±1 pF or <1% |
| Automatic Capacitance Search | Yes (stepper motor-driven) |
| Residual & Lead Inductance Compensation | Yes |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, tanδ, Tn |
| Compliance | GB/T 1693–2007, ASTM D150, GB 9622.9–1988 / SJ/T 11043–1996 |
| Brand | DAZHAN (Nanjing Dazhan Instrument Co., Ltd.) |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method (Q-factor-based) |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Direct Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Accuracy | ±1 pF or <1% |
| Automatic Capacitance Search | Yes (stepper motor-driven) |
| Residual Inductance Compensation | Yes |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, tanδ |
| Compliance | GB/T 1409–2006, GB/T 1693–2007 |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Tuning Capacitance | 17–240 pF (silver-plated monolithic) |
| Capacitance Direct Measurement Range | 1 pF – 25 nF |
| Capacitance Accuracy | ±1 pF or <1% |
| Capacitance Resolution | 0.1 pF |
| Auto Capacitance Search | Yes (stepper motor driven) |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc. |
| Residual Inductance Compensation | Yes |
| Data Interface | RS-232/USB for PC connectivity |
| Compliance | Designed per IEC 60250 and ASTM D150 guidelines for dielectric property measurement |
| Brand | DAZHAN |
|---|---|
| Model | DZ5001 |
| Measurement Principle | High-Frequency Resonance Method |
| Frequency Range | 10 kHz – 100 MHz |
| Frequency Accuracy | ±3×10⁻⁵ (6-digit resolution) |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit display) |
| Q Measurement Error | <5% |
| Inductance Range | 1 nH – 140 mH |
| Inductance Resolution | 0.1 nH |
| Inductance Error | <3% |
| Main Tuning Capacitance | 17–240 pF (silver-plated monolithic capacitor) |
| Capacitance Measurement Range | 1 pF – 25 nF |
| Capacitance Resolution | 0.1 pF |
| Capacitance Error | ±1 pF or <1% |
| Automatic Residual Inductance Compensation | Yes |
| Auto-Resonance Search | Yes (stepper motor–driven) |
| Display | LCD showing F, L, C, Q, Lt, Ct, εᵣ, Tn, etc. |
| Compliance | Designed for ASTM D150, IEC 60250, GB/T 1409, and ISO 18732-compliant dielectric characterization workflows |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HM410 |
| Pricing | Available Upon Request |
| Brand | Edmund Bühler |
|---|---|
| Origin | Germany |
| Model | MSP60 |
| Vacuum Chamber | High-vacuum compatible (≤1×10⁻⁵ mbar) |
| Copper Wheel Diameter | 250 mm (solid, optionally water-cooled) |
| Wheel Tilt Adjustment | Continuous angular control for optimized melt jet impingement |
| Crucible Options | 3-piece boron nitride crucible with adapter |
| RF Generator Power | 12 kW or 25 kW (configurable) |
| Temperature Monitoring | Pyrometer range 500–1700 °C (calibration traceable to NIST standards) |
| Melt Volume Capacity | 5–10 g per run |
| Cooling Rate | >10⁶ K/s (typical for amorphous ribbon formation) |
| Control Interface | Integrated touchscreen HMI with real-time display of wheel speed, RF power, melting duration, vacuum level, and pyrometer feedback |
| Auxiliary Systems | Recirculating chiller (required), compressed air supply (4–6 bar), turbo-molecular or diffusion pump train |